1.
Int J Mol Sci ; 25(2)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38255852

RESUMO

The global spread of multidrug-resistant (MDR) hospital-acquired pathogens is a serious problem for healthcare units. The challenge of the spreading of nosocomial infections, also known as hospital-acquired pathogens, including Pseudomonas aeruginosa, must be addressed not only by developing effective drugs, but also by improving preventive measures in hospitals, such as passive bactericidal coatings deposited onto the touch surfaces. In this paper, we studied the antibacterial activity of superhydrophilic and superhydrophobic copper surfaces against the P. aeruginosa strain PA103 and its four different polyresistant clinical isolates with MDR. To fabricate superhydrophilic and superhydrophobic coatings, we subjected the copper surfaces to laser processing with further chemosorption of fluorooxysilane to get a superhydrophobic substrate. The antibacterial activity of superhydrophilic and superhydrophobic copper surfaces was shown, with respect to both the collection strain PA103 and polyresistant clinical isolates of P. aeruginosa, and the evolution of the decontamination of a bacterial suspension is presented and discussed. The presented results indicate the promising potential of the exploitation of superhydrophilic coatings in the manufacture of contact surfaces for healthcare units, where the risk of infection spread and contamination by hospital-acquired pathogens is extremely high.


Assuntos
Cobre , Infecções por Pseudomonas , Humanos , Cobre/farmacologia , Pseudomonas aeruginosa , Antibacterianos/farmacologia , Hospitais , Interações Hidrofóbicas e Hidrofílicas
2.
Int J Mol Sci ; 25(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38674057

RESUMO

A method has been proposed for creating an operationally durable copper coating with antimicrobial properties for the buttons of electrical switches based on the gas dynamic spray deposition of copper on acrylonitrile butadiene styrene (ABS) plastic. It is shown that during the coating process, a polymer film is formed on top of the copper layer. Comparative in situ studies of microbial contamination have shown that the copper-coated buttons have a significant antimicrobial effect compared to standard buttons. Analysis of swabs over a 22-week study in a hospital environment showed that the frequency of contamination for a copper-coated button with various microorganisms was 2.7 times lower than that of a control button. The presented results allow us to consider the developed copper coating for plastic switches an effective alternative method in the fight against healthcare-associated infections.


Assuntos
Anti-Infecciosos , Cobre , Hospitais , Cobre/química , Anti-Infecciosos/química , Anti-Infecciosos/farmacologia , Plásticos/química , Infecção Hospitalar/prevenção & controle , Humanos
3.
ACS Omega ; 5(14): 7782-7786, 2020 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-32309686

RESUMO

Lung disease caused by Pseudomonas aeruginosa is the leading reason for death in cystic fibrosis patients. Therapeutic efficacy of the pharmacological pairs, the naked/encapsulated mutant form of Citrobacter freundii methionine γ-lyase and the substrates, sulfoxides of S-substituted l-cysteine, generating thiosulfinates, was evaluated on the murine model of experimental sepsis caused by the multidrug-resistant P. aeruginosa 203-2 strain. The pairs containing the naked enzyme and substrates did not have antibacterial activity. The treatment of mice with the pair encapsulated enzyme and S-methyl-l-cysteine sulfoxide, generating dimethyl thiosulfinate, led to a complete recovery of the animals of the model, with the infecting dose equal to LD50. The pair generating diallyl thiosulfinate (allicin) proved to be less effective. So, the substituents, attached to the thiosulfinate moiety, affect the antibacterial activity of thiosulfinates against P. aeruginosa.

4.
J Med Microbiol ; 60(Pt 1): 75-83, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20829396

RESUMO

Non-thermal (low-temperature) physical plasma is under intensive study as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. The purpose of this study was to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma and to measure the effectiveness of plasma treatments against bacteria in biofilms and on wound surfaces. Overall, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, Burkholderia cenocepacia and Escherichia coli, there were no survivors among the initial 10(5) c.f.u. after a 5 min plasma treatment. The susceptibility of Gram-positive bacteria was species- and strain-specific. Streptococcus pyogenes was the most resistant with 17 % survival of the initial 10(5) c.f.u. after a 5 min plasma treatment. Staphylococcus aureus had a strain-dependent resistance with 0 and 10 % survival from 10(5) c.f.u. of the Sa 78 and ATCC 6538 strains, respectively. Staphylococcus epidermidis and Enterococcus faecium had medium resistance. Non-ionized argon gas was not bactericidal. Biofilms partly protected bacteria, with the efficiency of protection dependent on biofilm thickness. Bacteria in deeper biofilm layers survived better after the plasma treatment. A rat model of a superficial slash wound infected with P. aeruginosa and the plasma-sensitive Staphylococcus aureus strain Sa 78 was used to assess the efficiency of argon plasma treatment. A 10 min treatment significantly reduced bacterial loads on the wound surface. A 5-day course of daily plasma treatments eliminated P. aeruginosa from the plasma-treated animals 2 days earlier than from the control ones. A statistically significant increase in the rate of wound closure was observed in plasma-treated animals after the third day of the course. Wound healing in plasma-treated animals slowed down after the course had been completed. Overall, the results show considerable potential for non-thermal argon plasma in eliminating pathogenic bacteria from biofilms and wound surfaces.


Assuntos
Anti-Infecciosos Locais/farmacologia , Anti-Infecciosos Locais/uso terapêutico , Argônio/farmacologia , Argônio/uso terapêutico , Viabilidade Microbiana/efeitos dos fármacos , Gases em Plasma/farmacologia , Gases em Plasma/uso terapêutico , Animais , Antissepsia/métodos , Infecções Bacterianas/tratamento farmacológico , Infecções Bacterianas/microbiologia , Biofilmes/efeitos dos fármacos , Contagem de Colônia Microbiana , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Masculino , Testes de Sensibilidade Microbiana , Modelos Animais , Ratos , Ratos Sprague-Dawley , Infecção dos Ferimentos/tratamento farmacológico , Infecção dos Ferimentos/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA