Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 148
Filtrar
1.
Pacing Clin Electrophysiol ; 47(7): 869-877, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38605573

RESUMO

BACKGROUND: Several studies have demonstrated that females have a higher risk of arrhythmia recurrence after pulmonary vein (PV) isolation for atrial fibrillation (AF). There are limited data on sex-based differences in PV reconnection rates at repeat ablation. We aimed to investigate sex-based differences in electrophysiological findings and atrial arrhythmia recurrence after repeat AF ablation METHODS: We conducted a retrospective study of 161 consecutive patients (32% female, age 65 ± 10 years) who underwent repeat AF ablation after index PV isolation between 2010 and 2022. Demographics, procedural characteristics and follow-up data were collected. Recurrent atrial tachycardia (AT)/AF was defined as any atrial arrhythmia ≥30 s in duration. RESULTS: Compared to males, females tended to be older and had a significantly higher prevalence of prior valve surgery (10 vs. 2%; P = .03). At repeat ablation, PV reconnection was found in 119 (74%) patients. Males were more likely to have PV reconnection at repeat ablation compared to females (81 vs. 59%; P = .004). Excluding repeat PV isolation, there were no significant differences in adjunctive ablation strategies performed at repeat ablation between females and males. During follow-up, there were no significant differences in freedom from AT/AF recurrence between females and males after repeat ablation (63 vs. 59% at 2 years, respectively; P = .48). CONCLUSIONS: After initial PV isolation, significantly fewer females have evidence of PV reconnection at the time of repeat ablation for recurrent AF. Despite this difference, long-term freedom from AT/AF was similar between females and males after repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Veias Pulmonares/cirurgia , Masculino , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Fatores Sexuais , Pessoa de Meia-Idade
2.
Stroke ; 54(4): 947-954, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36866671

RESUMO

BACKGROUND: Percutaneous endocardial left atrial appendage occlusion (LAAO) is an alternative therapy for stroke prevention in patients with atrial fibrillation who are poor candidates for oral anticoagulants. Oral anticoagulation is generally discontinued 45 days following successful LAAO. Real-world data on early stroke and mortality following LAAO are lacking. METHODS: Using International Classification of Diseases, Tenth Revision, Clinical-Modification codes, we performed a retrospective observational registry analysis to examine the rates and predictors of stroke, mortality, and procedural complications during index hospitalization and 90-day readmission among 42 114 admissions in the Nationwide Readmissions Database for LAAO between 2016 and 2019. Early stroke and mortality were defined as events occurring during index admission or 90-day readmission. Data on timing of early strokes post-LAAO were collected. Multivariable logistic regression modeling was used to ascertain predictors of early stroke and major adverse events. RESULTS: LAAO was associated with low rates of early stroke (0.63%), early mortality (0.53%), and procedural complications (2.59%). Among patients who had readmissions with strokes after LAAO, the median time from implant to readmission was 35 days (interquartile range, 9-57 days); 67% of readmissions with strokes occurred <45 days postimplant. Between 2016 and 2019, the rates of early stroke after LAAO significantly decreased (0.64% versus 0.46% P-for-trend <0.001), while early mortality and major adverse event rates were unchanged. Peripheral vascular disease and a history of prior stroke were independently associated with early stroke after LAAO. Early post-LAAO stroke rates were similar between low, medium, and high LAAO volume tertile centers. CONCLUSIONS: In this contemporary real-world analysis, the early stroke rate after LAAO was low, with the majority occurring within 45 days of device implantation. Despite an increase in LAAO procedures between 2016 and 2019, there with a significant decline in early strokes after LAAO during that period.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Anticoagulantes , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 34(3): 710-717, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36571159

RESUMO

INTRODUCTION: Left bundle branch area pacing (LBBP) has emerged as an alternative method for conduction system pacing. While initial experience with delivery systems for stylet-driven and lumenless lead implantation for LBBP has been described, data comparing outcomes of stylet-driven versus lumenless lead implantation for LBBP are limited. In this study, we compare success rates and outcomes of LBBP with stylet-driven versus lumenless lead delivery systems. METHODS: Eighty-three consecutive patients (mean age 74.1 ± 11.2 years; 56 [68%] male) undergoing attempted LBBP at a single institution were identified. Cases were grouped by lead delivery systems used: stylet-driven (n = 53) or lumenless (n = 30). Baseline characteristics and procedural findings were recorded and compared between the cohorts. Intermediate term follow-up data on ventricular lead parameters were also compared. RESULTS: Baseline characteristics were similar between groups. Successful LBBP was achieved in 77% of patients, with similar success rates between groups (76% in stylet-driven, 80% in lumenless, p = 0.79), and rates of adjudicated LBB capture and other paced QRS parameters were also similar. Compared with the lumenless group, the stylet-driven group had significantly shorter procedure times (90 ± 4 vs. 112 ± 31 min, p = 0.004) and fluoroscopy times (10 ± 5 vs. 15 ± 6 min, p = 0.003). Ventricular lead parameters at follow-up were similar, and rates of procedural complications and need for lead revision were low in both groups. CONCLUSION: Delivery systems for stylet-driven and for lumenless leads for LBBP have comparable acute success rates. Long-term follow-up of lead performance following use of the various delivery systems is warranted.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco
4.
Pacing Clin Electrophysiol ; 46(5): 385-391, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37087556

RESUMO

INTRODUCTION: Frequent right ventricular (RV) pacing is associated with cardiomyopathy. The impact of RV pacing on left ventricular (LV) global longitudinal strain (GLS) and clinical outcomes is unclear. METHODS: We analyzed GLS via two-dimensional speckle tracking and LV ejection fraction (EF) on pre- and post-implantation transthoracic echocardiograms of patients undergoing dual chamber pacemaker implantation. We collected long-term data on strain, LVEF, and clinical outcomes. RESULTS: One hundred and ten patients (mean age 76 ± 12 years; 59 [54%] female) were followed for mean 23 ± 17 months. Mean baseline LVEF was 58 ± 11% and mean GLS was -17 ± 4%. Twenty-four (22%) patients had an absolute decrease in LVEF > 10% and 43 (39%) patients had a relative reduction of GLS > 15%. Among patients with a reduction of GLS, a larger proportion of patients had RV pacing burden ≥20% (67% vs. 46%; p = .048). Compared to patients without GLS reduction, more patients with a reduction in GLS reached a composite endpoint of HF hospitalization, CRT upgrade or death (47% vs. 16%; p = .001). CONCLUSION: Reduction in LV GLS was seen in nearly four in 10 patients undergoing pacemaker implantation and was significantly associated with increased RV pacing burden. LV GLS reduction was associated with increased risk of adverse outcomes. LV GLS may have utility in predicting outcomes among patients with RV pacing.


Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Deformação Longitudinal Global , Marca-Passo Artificial/efeitos adversos , Função Ventricular Esquerda , Ecocardiografia/métodos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Volume Sistólico
5.
Eur Heart J ; 43(31): 2971-2980, 2022 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-35764099

RESUMO

AIMS: Post-operative atrial fibrillation (POAF) is associated with stroke and mortality. It is unknown if POAF is associated with subsequent heart failure (HF) hospitalization. This study aims to examine the association between POAF and incident HF hospitalization among patients undergoing cardiac and non-cardiac surgeries. METHODS AND RESULTS: A retrospective cohort study was conducted using all-payer administrative claims data that included all non-federal emergency department visits and acute care hospitalizations across 11 states in the USA. The study population included adults aged at least 18 years hospitalized for surgery without a prior diagnosis of HF. Cox proportional hazards regression models were used to examine the association between POAF and incident HF hospitalization after making adjustment for socio-demographics and comorbid conditions. Among 76 536 patients who underwent cardiac surgery, 14 365 (18.8%) developed incident POAF. In an adjusted Cox model, POAF was associated with incident HF hospitalization [hazard ratio (HR) 1.33; 95% confidence interval (CI) 1.25-1.41]. In a sensitivity analysis excluding HF within 1 year of surgery, POAF remained associated with incident HF hospitalization (HR 1.15; 95% CI 1.01-1.31). Among 2 929 854 patients who underwent non-cardiac surgery, 23 763 (0.8%) developed incident POAF. In an adjusted Cox model, POAF was again associated with incident HF hospitalization (HR 2.02; 95% CI 1.94-2.10), including in a sensitivity analysis excluding HF within 1 year of surgery (HR 1.49; 95% CI 1.38-1.61). CONCLUSIONS: Post-operative atrial fibrillation is associated with incident HF hospitalization among patients without prior history of HF undergoing both cardiac and non-cardiac surgeries. These findings reinforce the adverse prognostic impact of POAF and suggest that POAF may be a marker for identifying patients with subclinical HF and those at elevated risk for HF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Adolescente , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Hospitalização , Humanos , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco
6.
BMC Health Serv Res ; 22(1): 89, 2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35045849

RESUMO

BACKGROUND: As health care markets in the United States have become increasingly consolidated, the role of market concentration on physician treatment behavior remains unclear. In cardiology, specifically, there has been evolving treatment of acute myocardial infarction complicated by cardiogenic shock (AMI-CS) with increasing use of mechanical circulatory support (MCS). However, there remains wide variation in it use. The role of market concentration in the utilization of MCS in AMI-CS is unknown. We examined the use of MCS in AMI-CS and its effect on outcomes between competitive and concentrated markets. METHODS AND RESULTS: We used the National Inpatient Sample to query patients admitted with AMI-CS between 2003 and 2009. The primary study outcome was the use of mechanical circulatory support. The primary study exposure was market concentration, measured using the Herfindahl-Hirschman Index, which was used to classify markets as unconcentrated (competitive), moderately concentrated, and highly concentrated. Baseline characteristics, procedures, and outcomes were compared for patients in differently concentrated markets. Multivariable logistic regression was used to examine the association between HHI and use of MCS. RESULTS: There were 32,406 hospitalizations for patients admitted with AMI-CS. Patients in unconcentrated markets were more likely to receive MCS than in highly concentrated markets (unconcentrated 46.8% [5087/10,873], moderately concentrated 44.9% [2933/6526], and high concentrated 44.5% [6676/15,007], p < 0.01). Multivariable regression showed that patients in more concentrated markets had decreased use of MCS in patients in later years of the study period (2009, OR 0.64, 95% CI 0.44-0.94, p = 0.02), with no effect in earlier years. There was no significant difference in in-hospital mortality. CONCLUSION: Multivariable analysis did not show an association with market concentration and use of MCS in AMI-CS. However, subgroup analysis did show that competitive hospital markets were associated with more frequent use of MCS in AMI-CS as frequency of utilization increased over time. Further studies are needed to evaluate the effect of hospital market consolidation on the use of MCS and outcomes in AMI-CS.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Mortalidade Hospitalar , Hospitais , Humanos , Balão Intra-Aórtico , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Choque Cardiogênico/terapia , Estados Unidos/epidemiologia
7.
Stroke ; 51(9): e203-e210, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32781943

RESUMO

BACKGROUND AND PURPOSE: One-fifth of ischemic strokes are embolic strokes of undetermined source (ESUS). Their theoretical causes can be classified as cardioembolic versus noncardioembolic. This distinction has important implications, but the categories' proportions are unknown. METHODS: Using data from the Cornell Acute Stroke Academic Registry, we trained a machine-learning algorithm to distinguish cardioembolic versus non-cardioembolic strokes, then applied the algorithm to ESUS cases to determine the predicted proportion with an occult cardioembolic source. A panel of neurologists adjudicated stroke etiologies using standard criteria. We trained a machine learning classifier using data on demographics, comorbidities, vitals, laboratory results, and echocardiograms. An ensemble predictive method including L1 regularization, gradient-boosted decision tree ensemble (XGBoost), random forests, and multivariate adaptive splines was used. Random search and cross-validation were used to tune hyperparameters. Model performance was assessed using cross-validation among cases of known etiology. We applied the final algorithm to an independent set of ESUS cases to determine the predicted mechanism (cardioembolic or not). To assess our classifier's validity, we correlated the predicted probability of a cardioembolic source with the eventual post-ESUS diagnosis of atrial fibrillation. RESULTS: Among 1083 strokes with known etiologies, our classifier distinguished cardioembolic versus noncardioembolic cases with excellent accuracy (area under the curve, 0.85). Applied to 580 ESUS cases, the classifier predicted that 44% (95% credibility interval, 39%-49%) resulted from cardiac embolism. Individual ESUS patients' predicted likelihood of cardiac embolism was associated with eventual atrial fibrillation detection (OR per 10% increase, 1.27 [95% CI, 1.03-1.57]; c-statistic, 0.68 [95% CI, 0.58-0.78]). ESUS patients with high predicted probability of cardiac embolism were older and had more coronary and peripheral vascular disease, lower ejection fractions, larger left atria, lower blood pressures, and higher creatinine levels. CONCLUSIONS: A machine learning estimator that distinguished known cardioembolic versus noncardioembolic strokes indirectly estimated that 44% of ESUS cases were cardioembolic.


Assuntos
Embolia Intracraniana/patologia , Aprendizado de Máquina , Acidente Vascular Cerebral/patologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/complicações , Árvores de Decisões , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Embolia Intracraniana/complicações , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sistema de Registros , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/etiologia
8.
J Cardiovasc Electrophysiol ; 31(3): 739-752, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32022316

RESUMO

Robotic technology has emerged as an important tool to facilitate catheter ablation of arrhythmias. Robotic cardiac electrophysiology technology includes remote magnetic navigation and manual robotic navigation. Robotics can confer advantages with respect to ease of catheter manipulation in anatomically challenging spaces, minimization of fluoroscopic exposure to both patients and operators, and reduction in operator fatigue. This review provides a comprehensive summary of robotic electrophysiology technology, its practical applications and its safety and efficacy for targeting cardiac arrhythmias.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Procedimentos Cirúrgicos Robóticos , Potenciais de Ação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 31(12): 3077-3085, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33017083

RESUMO

INTRODUCTION: The impact of atrial arrhythmias on coronavirus disease 2019 (COVID-19)-associated outcomes are unclear. We sought to identify prevalence, risk factors and outcomes associated with atrial arrhythmias among patients hospitalized with COVID-19. METHODS: An observational cohort study of 1053 patients with severe acute respiratory syndrome coronavirus 2 infection admitted to a quaternary care hospital and a community hospital was conducted. Data from electrocardiographic and telemetry were collected to identify atrial fibrillation (AF) or atrial flutter/tachycardia (AFL). The association between atrial arrhythmias and 30-day mortality was assessed with multivariable analysis. RESULTS: Mean age of patients was 62 ± 17 years and 62% were men. Atrial arrhythmias were identified in 166 (15.8%) patients, with AF in 154 (14.6%) patients and AFL in 40 (3.8%) patients. Newly detected atrial arrhythmias occurred in 101 (9.6%) patients. Age, male sex, prior AF, renal disease, and hypoxia on presentation were independently associated with AF/AFL occurrence. Compared with patients without AF/AFL, patients with AF/AFL had significantly higher levels of troponin, B-type natriuretic peptide, C-reactive protein, ferritin and d-dimer. Mortality was significantly higher among patients with AF/AFL (39.2%) compared to patients without (13.4%; p < .001). After adjustment for age and co-morbidities, AF/AFL (adjusted odds ratio [OR]: 1.93; p = .007) and newly detected AF/AFL (adjusted OR: 2.87; p < .001) were independently associated with 30-day mortality. CONCLUSION: Atrial arrhythmias are common among patients hospitalized with COVID-19. The presence of AF/AFL tracked with markers of inflammation and cardiac injury. Atrial arrhythmias were independently associated with increased mortality.


Assuntos
Fibrilação Atrial/mortalidade , Flutter Atrial/mortalidade , COVID-19/mortalidade , Mortalidade Hospitalar , Hospitalização , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Flutter Atrial/diagnóstico , Flutter Atrial/terapia , COVID-19/diagnóstico , COVID-19/terapia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque/epidemiologia , Prevalência , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 31(8): 1908-1919, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32449825

RESUMO

INTRODUCTION: The real-world distribution of hospital atrial fibrillation (AF) ablation volume and its impact on outcomes are not well-established. We sought to examine patient characteristics, complications, and readmissions after AF ablation stratified by hospital procedural volume. METHODS AND RESULTS: Using the nationally representative inpatient Nationwide Readmissions Database, we evaluated 54 597 admissions for AF ablation between 2010 and 2014. Hospitals were categorized according to tertiles of annual AF ablation volume. Index complications, 30-day readmissions, and early mortality were examined. Multivariable logistic regression was performed to assess the predictors of adverse outcomes. Between 2010 and 2014, low volume tertile hospitals accounted for 79.3% of hospitals performing AF ablations. When stratified by first, second, and third volume tertiles, complication and early mortality rates were higher in low volume centers (8.9% and 0.67% vs 6.1% and 0.33%, vs 4.5% and 0.16%, respectively; P < .001). Patients undergoing AF ablation at low volume centers were older and had a higher prevalence of congestive heart failure, coronary artery disease, and other comorbidities. Low volume hospitals were associated with increased cardiac perforation (adjusted odds ratio [aOR], 4.79; P < .001), vascular complications (aOR 1.49; P < .001), and any complication (aOR 2.06; P < .001) during index admission as well as increased early mortality (aOR 2.43; P = .039). CONCLUSIONS: Among patients hospitalized for AF ablation, low inpatient AF ablation hospital volume was associated with worse outcomes following ablation, which was exacerbated by a greater comorbidity burden among patients at these centers.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Hospitais com Baixo Volume de Atendimentos , Humanos , Pacientes Internados , Readmissão do Paciente
11.
Eur Heart J ; 40(36): 3035-3043, 2019 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-30927423

RESUMO

AIMS: Although catheter ablation has emerged as an important therapy for patients with symptomatic atrial fibrillation (AF), there are limited data on sex-based differences in outcomes. We sought to compare in-hospital outcomes and 30-day readmissions of women and men undergoing AF ablation. METHODS AND RESULTS: Using the United States Nationwide Readmissions Database, we analysed patients undergoing AF ablation between 2010 and 2014. Based on ICD-9-CM codes, we identified co-morbidities and outcomes. Multivariable logistic regression and inverse probability-weighting analysis were performed to assess female sex as a predictor of endpoints. Of 54 597 study patients, 20 623 (37.7%) were female. After adjustment for age, co-morbidities, and hospital factors, women had higher rates of any complication [adjusted odds ratio (aOR) 1.39; P < 0.0001], cardiac perforation (aOR 1.39; P = 0.006), and bleeding/vascular complications (aOR 1.49; P < 0.0001). Thirty-day all-cause readmission rates were higher for women compared to men (13.4% vs. 9.4%; P < 0.0001). Female sex was independently associated with readmission for AF/atrial tachycardia (aOR 1.48; P < 0.0001), cardiac causes (aOR 1.40; P < 0.0001), and all causes (aOR 1.25; P < 0.0001). Similar findings were confirmed with inverse probability-weighting analysis. Despite increased complications and readmissions, total costs for AF ablation were lower for women than men due to decreased resource utilization. CONCLUSIONS: Independent of age, co-morbidities, and hospital factors, women have higher rates of complications and readmissions following AF ablation. Sex-based differences and disparities in the management of AF need to be explored to address these gaps in outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/economia , Readmissão do Paciente/estatística & dados numéricos , Idoso , Fibrilação Atrial/epidemiologia , Bases de Dados Factuais , Feminino , Traumatismos Cardíacos/epidemiologia , Hemorragia/epidemiologia , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Distribuição por Sexo , Taquicardia/epidemiologia , Estados Unidos/epidemiologia
13.
J Cardiovasc Electrophysiol ; 30(12): 3057-3067, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31579980

RESUMO

Left atrial tachycardias (ATs) most commonly occur after catheter or surgical ablation of atrial fibrillation and in patients with atrial myopathies. Pre-existing scar in the left atrium (LA) can result in complex circuits, sometimes with narrow channels that can be detected with high-resolution mapping. The most common forms of macroreentrant AT from the LA are variants of peri-mitral and roof-dependent reentry. Localized reentrant rhythms occur in the setting of fibrosis that gives rise to slow conduction and may occur adjacent to areas of prior ablation. The approach to treating these ATs involves first identifying the left atrial origin, defining the tachycardia circuit - which can be facilitated by ultrahigh density mapping and entrainment - and selecting a suitable isthmus to target for ablation. An important endpoint in ablating left atrial flutters is to establish and confirm bidirectional line of the block. Challenges in ablating these ATs include the presence of multiple tachycardias, defining circuits with complex activation patterns and achieving durable lines of block, particularly in the lateral mitral isthmus. Progress in treating these arrhythmias has come from new mapping technologies and the recognition of epicardial connections that allow for persistent conduction across ablation lesions. Also, advances in delivering energy to obtain complete transmural lesions promise to improve the long-term success of ablating ATs from the LA.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Átrios do Coração/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 30(12): 2773-2781, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31626356

RESUMO

INTRODUCTION: The role of focal impulse and rotor modulation (FIRM)-guided ablation for the treatment of atrial fibrillation (AF) remains unclear. Previous studies on the FIRM-guided ablation outcomes have been limited by a focus on AF termination as an endpoint and by patient population heterogeneity. We sought to determine differences in rates of AF termination, inducibility, and recurrence in patients with persistent AF undergoing first-time ablation with a FIRM-guided approach compared with patients undergoing conventional ablation. METHODS AND RESULTS: Eight-five consecutive patients (38 FIRM, 47 conventional) with persistent AF undergoing first-time ablation were retrospectively analyzed. There were no significant differences in the rates of AF termination in the FIRM group compared to the conventional group (26% vs 15%; P = .15). Rates of inducible AF after ablation were 37% in the FIRM group and 30% in the conventional group (P = .32). Over a median follow-up of 2.4 years, the rates of freedom from AF were similar between the FIRM and conventional groups (1-year freedom from AF 65% vs 50%, respectively; P = .18). Procedural termination of AF with either FIRM ablation or conventional ablation was not associated with any significant reduction in AF recurrence. CONCLUSION: A FIRM-guided approach was not associated with a significant difference in freedom from AF when compared to conventional ablation. Termination of AF with ablation was not associated with increased freedom from AF. While AF termination using substrate-based ablation may have mechanistic implications for understanding AF rotor physiology, its impact on clinical outcomes remains unclear.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
15.
J Cardiovasc Electrophysiol ; 30(10): 1994-2001, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328298

RESUMO

INTRODUCTION: Subclinical atrial fibrillation (AF), in the form of cardiac implantable device-detected atrial high rate episodes (AHREs), has been associated with increased thromboembolism. An implantable cardioverter-defibrillator (ICD) lead with a floating atrial dipole may permit a single lead (DX) ICD system to detect AHREs. We sought to assess the utility of the DX ICD system for subclinical AF detection in patients, with a prospective multicenter, cohort-controlled trial. METHODS AND RESULTS: One hundred fifty patients without prior history of AF (age 59 ± 13 years; 108 [72%] male) were enrolled into the DX cohort and implanted with a Biotronik DX ICD system at eight centers. Age-, sex-, and left ventricular ejection fraction-matched single- and dual-chamber ICD cohorts were derived from a Cornell database and from the IMPACT trial, respectively. The primary endpoint were AHRE detection at 12 months. During median 12 months follow-up, AHREs were detected in 19 (13%) patients in the DX, 8 (5.3%) in the single-chamber, and 19 (13%) in the dual-chamber cohorts. The rate of AHRE detection was significantly higher in the DX cohort compared to the single-chamber cohort (P = .026), but not significantly different compared to the dual-chamber cohort. There were no inappropriate ICD therapies in the DX cohort. At 12 months, only 3.0% of patients in the DX cohort had sensed atrial amplitudes less than 1.0 mV. CONCLUSION: Use of a DX ICD lead allows subclinical AF detection with a single lead DX system that is superior to that of a conventional single-chamber ICD system.


Assuntos
Fibrilação Atrial/diagnóstico , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Tecnologia de Sensoriamento Remoto/instrumentação , Potenciais de Ação , Adulto , Idoso , Doenças Assintomáticas , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Estados Unidos
16.
J Cardiovasc Electrophysiol ; 30(10): 1773-1785, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31225670

RESUMO

BACKGROUND: Ablation of atrial tachycardia (AT) that occurs after cardiac surgery or prior ablation often requires complex lesion sets. In combination with the pre-existing atrial scar, these lesion sets may result in inadvertent intra-atrial conduction block. This study reports the phenomenon of incidental isolation of right atrial (RA) regions that occurs secondary to AT ablation, which in some cases results in profound bradycardia due to sinus exit block. METHODS AND RESULTS: Intracardiac electrograms were examined in consecutive patients who underwent AT ablation in the RA. Cases of localized isolation of the RA were defined as areas that developed electrical dissociation during ablation. Of 132 patients having ablation in both the RA free wall and the cavotricuspid isthmus (CTI), 10 (7.6%) developed unintentional isolation of the lateral RA. Five of these patients had prior mitral valve surgery, comprising 12.2% of all 41 patients with mitral surgery who underwent ablation in the CTI and the RA free wall. All patients with regional isolation had a pre-existing scar in the lateral wall of the RA. In six patients, isolation of the lateral RA resulted in profound bradycardia due to exit block from the peri-sinus node myocardium. CONCLUSIONS: Complex ablation lesions in patients with prior valve surgery, prior ablation, or atrial myopathy may result in unintended localized conduction block in the RA. In some cases, isolation of the lateral RA can result in complete sinus exit block with profound bradycardia requiring pacemaker implantation.


Assuntos
Flutter Atrial/cirurgia , Função do Átrio Direito , Bradicardia/etiologia , Ablação por Cateter/efeitos adversos , Átrios do Coração/cirurgia , Frequência Cardíaca , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Bradicardia/diagnóstico , Bradicardia/fisiopatologia , Bradicardia/terapia , Estimulação Cardíaca Artificial , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 29(8): 1181-1188, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29659078

RESUMO

Idiopathic sustained focal right ventricular tachycardia (VT) is most frequently due to outflow tract (OT) tachycardia. This arrhythmia is recognized by its characteristic ECG pattern and sensitivity to adenosine. However, there are other forms of idiopathic, focal sustained VT that originate from the right ventricle (RV), which are less well appreciated and easily overlooked. This review will identify the characteristic features and electrophysiologic properties of these forms of RV VT, including those originating from the tricuspid annulus, right ventricular papillary muscles, and moderator band as well as variants of classic RVOT tachycardia and those due to microreentry in the presence of preclinical disease. Recognition of these subtypes of focal RV tachycardia should facilitate targeted therapy.


Assuntos
Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Adenosina/uso terapêutico , Antiarrítmicos/uso terapêutico , Diagnóstico Diferencial , Humanos , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/fisiopatologia , Taquicardia Ventricular/tratamento farmacológico , Disfunção Ventricular Direita/tratamento farmacológico , Verapamil/uso terapêutico
18.
Catheter Cardiovasc Interv ; 92(2): E135-E138, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28296026

RESUMO

The development of paravalvular leak (PVL) following surgical replacement of an aortic or mitral valve is an uncommon complication with significant morbidity and mortality. Surgical or percutaneous repair of PVL can be technically challenging. We describe the application of intracardiac echocardiography guided 3-dimensional electroanatomic mapping to facilitate PVL closure in a symptomatic patient with a previously placed bioprosthetic mitral valve. © 2017 Wiley Periodicals, Inc.


Assuntos
Bioprótese , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Técnicas Eletrofisiológicas Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Falha de Prótese , Cateterismo Cardíaco/instrumentação , Ecocardiografia Doppler em Cores , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Resultado do Tratamento
19.
Europace ; 20(suppl_2): ii5-ii10, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29722854

RESUMO

Aims: Due to the complex anatomy of the left ventricular (LV) and right ventricular (RV) papillary muscles (PMs), PM ventricular arrhythmias (VAs) can be challenging to target with ablation. We sought to compare the outcomes of robotic magnetic navigation-guided (RMN) ablation and manual ablation of VAs arising from the LV and RV PMs. Methods and results: We evaluated 35 consecutive patients (mean age 65 ± 12 years, 69% male) who underwent catheter ablation of 38 VAs originating from the LV and RV PMs as confirmed by intracardiac echocardiography. Catheter ablation was initially performed using RMN-guidance in 24 (69%) patients and manual guidance in 11 (31%) patients. Demographic and procedural data were recorded and compared between the two groups. The VA sites of origin were mapped to 20 (53%) anterolateral LV PMs, 14 (37%) posteromedial LV PMs, and 4 (11%) RV PMs Acute successful ablation was achieved for 20 (74%) VAs using RMN-guided ablation and 8 (73%) VAs using manual ablation (P = 1.000). Fluoroscopy times were significantly lower among patients undergoing RMN ablation compared to patients undergoing manual ablation [median 7.3, interquartile range (IQR) 3.9-18 vs. 24 (16-44) min; P = 0.005]. Retrograde transaortic approach was used in 1 (4%) RMN patients and 5 (46%) manual patients (P = 0.005). No procedural complications were seen in study patients. Conclusion: Use of an RMN-guided approach to target PM VAs results in comparable success rates seen with manual ablation but with lower fluoroscopy times and decreased use of transaortic retrograde access.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Ventrículos do Coração/cirurgia , Magnetismo/métodos , Músculos Papilares/cirurgia , Cirurgia Assistida por Computador/métodos , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Potenciais de Ação , Idoso , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/fisiopatologia , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita , Complexos Ventriculares Prematuros/diagnóstico por imagem , Complexos Ventriculares Prematuros/fisiopatologia
20.
J Cardiovasc Electrophysiol ; 28(5): 544-548, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28185354

RESUMO

INTRODUCTION: The subcutaneous implantable cardioverter defibrillator (ICD) has emerged as a viable therapeutic option for patients who are deemed high risk for sudden cardiac death. Previous studies have shown that 7-15% of patients are not candidates for the S-ICD based on their intrinsic QRS/T-wave morphology. Presently, it is not known if the S-ICD can be considered as supplementary therapy in patients who are ventricularly paced. We sought to determine the proportion of ventricularly paced patients who would qualify for an S-ICD. METHODS AND RESULTS: We evaluated 100 patients with transvenous pacemakers/ICDs, including 25 biventricular devices to determine S-ICD candidacy during right ventricular (RV) pacing and biventricular pacing based on the recommended QRS:T-wave ratio screening template. Fifty-eight percent of patients qualified for an S-ICD based on their QRS morphology during ventricular pacing. More patients during biventricular pacing met criteria compared to during RV pacing alone (80% vs. 46%, P <0.01). Patients that were paced from the RV septum were more likely to qualify compared to those paced from the RV apex (67% vs. 37%, respectively, P <0.01). CONCLUSION: While S-ICD implantation may be considered as supplemental therapy in select patients with preexisting transvenous devices, relatively fewer candidates who are paced from the RV apex qualify. QRS morphologies generated from biventricular pacing as well as from septal RV pacing are more likely to screen in based on the recommended S-ICD template.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Definição da Elegibilidade , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Tomada de Decisão Clínica , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Função Ventricular Esquerda , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA