Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Chem Rev ; 124(10): 6393-6443, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38669641

RESUMO

Traditionally, alkaline water electrolysis (AWE) uses diaphragms to separate anode and cathode and is operated with 5-7 M KOH feed solutions. The ban of asbestos diaphragms led to the development of polymeric diaphragms, which are now the state of the art material. A promising alternative is the ion solvating membrane. Recent developments show that high conductivities can also be obtained in 1 M KOH. A third technology is based on anion exchange membranes (AEM); because these systems use 0-1 M KOH feed solutions to balance the trade-off between conductivity and the AEM's lifetime in alkaline environment, it makes sense to treat them separately as AEM WE. However, the lifetime of AEM increased strongly over the last 10 years, and some electrode-related issues like oxidation of the ionomer binder at the anode can be mitigated by using KOH feed solutions. Therefore, AWE and AEM WE may get more similar in the future, and this review focuses on the developments in polymeric diaphragms, ion solvating membranes, and AEM.

2.
Nano Lett ; 16(11): 7261-7269, 2016 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-27775893

RESUMO

Nanostructured silicon (Si) is useful in many applications and has typically been synthesized by bottom-up colloid-based solution processes or top-down gas phase reactions at high temperatures. These methods, however, suffer from toxic precursors, low yields, and impractical processing conditions (i.e., high pressure). The magnesiothermic reduction of silicon oxide (SiO2) has also been introduced as an alternative method. Here, we demonstrate the reduction of SiO2 by a simple milling process using a lab-scale planetary-ball mill and industry-scale attrition-mill. Moreover, an ignition point where the reduction begins was consistently observed for the milling processes, which could be used to accurately monitor and control the reaction. The complete conversion of rice husk SiO2 to high purity Si was demonstrated, taking advantage of the rice husk's uniform nanoporosity and global availability, using a 5L-scale attrition-mill. The resulting porous Si showed excellent performance as a Li-ion battery anode, retaining 82.8% of the initial capacity of 1466 mAh g-1 after 200 cycles.

3.
Bioorg Med Chem ; 23(20): 6673-82, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26386817

RESUMO

We synthesized a library of curcumin mimics with diverse alkylsulfonyl and substituted benzenesulfonyl modifications through a simple addition reaction of important intermediate, 1-(3-Amino-phenyl)-3-(4-hydroxy-3-methoxy-phenyl)-propenone (10), with various sulfonyl chloride reactants and then tested their vasodilatation effect on depolarization (50 mM K(+))- and endothelin-1 (ET-1)-induced basilar artery contraction. Generally, curcumin mimics with aromatic sulfonyl groups showed stronger vasodilation effect than alkyl sulfonylated curcumin mimics. Among the tested compounds, six curcumin mimics (11g, 11h, 11i, 11j, 11l, and 11s) in a depolarization-induced vasoconstriction and seven compounds (11g, 11h, 11i, 11j, 11l, 11p, and 11s) in an ET-1-induced vasoconstriction showed strong vasodilation effect. Based on their biological properties, synthetic curcumin mimics can act as dual antagonist scaffold of L-type Ca(2+) channel and endothelin A/B2 receptor in vascular smooth muscle cells. In particular, compounds 11g and 11s are promising novel drug candidates to treat hypertension related to the overexpression of L-type Ca(2+) channels and ET peptides/receptors-mediated cardiovascular diseases.


Assuntos
Bloqueadores dos Canais de Cálcio/farmacologia , Curcumina/farmacologia , Antagonistas do Receptor de Endotelina A/farmacologia , Antagonistas do Receptor de Endotelina B/farmacologia , Animais , Bloqueadores dos Canais de Cálcio/síntese química , Bloqueadores dos Canais de Cálcio/química , Canais de Cálcio Tipo L/metabolismo , Curcumina/síntese química , Curcumina/química , Relação Dose-Resposta a Droga , Antagonistas do Receptor de Endotelina A/síntese química , Antagonistas do Receptor de Endotelina A/química , Antagonistas do Receptor de Endotelina B/síntese química , Antagonistas do Receptor de Endotelina B/química , Masculino , Estrutura Molecular , Coelhos , Receptor de Endotelina A/metabolismo , Receptor de Endotelina B/metabolismo , Relação Estrutura-Atividade
4.
J Card Surg ; 30(11): 869-71, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26347383

RESUMO

Ewing's sarcoma is a histological type of malignant mesenchymal tumor and rarely originates from the heart. We report a case of Ewing's sarcoma located in the right ventricular outflow tract that invaded the left pulmonary vein in a 29-year-old female.


Assuntos
Implante de Prótese Vascular/métodos , Neoplasias Cardíacas/cirurgia , Transplante de Coração/métodos , Ventrículos do Coração , Veias Pulmonares/cirurgia , Sarcoma de Ewing/cirurgia , Neoplasias Vasculares/cirurgia , Adulto , Feminino , Neoplasias Cardíacas/patologia , Humanos , Invasividade Neoplásica , Sarcoma de Ewing/patologia , Resultado do Tratamento , Neoplasias Vasculares/patologia
5.
J Chest Surg ; 57(3): 272-280, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38374156

RESUMO

Background: The phenomenon known as the "weekend effect" impacts various medical disciplines. We compared outcomes between regular hours and off hours to investigate the presence of the weekend effect in extracorporeal cardiopulmonary resuscitation (ECPR). Methods: Between January 2018 and December 2020, 159 patients at our center were treated with veno-arterial extracorporeal membrane oxygenation (ECMO) for cardiac arrest. We assessed the time required for ECMO preparation, the rate of successful weaning, and the rate of in-hospital mortality. These factors were compared among regular hours ("daytime": weekdays from 7:00 AM-7:00 PM), off hours on weekdays ("nighttime": weekdays from 7:00 PM-7:00 AM), and off hours on weekends and holidays ("weekend": Fridays at 7:00 PM to Mondays at 7:00 AM). Results: The time from the recognition of cardiac arrest to the arrival of the ECMO team was shortest for the daytime group and longest for those treated over the weekend (daytime, 10.0 minutes; nighttime, 12.5 minutes; weekend, 15.0 minutes; p=0.064). The time from the ECMO team's arrival to ECMO initiation was shortest for the daytime and longest for the nighttime group (daytime, 13.0 minutes; nighttime, 18.5 minutes; weekend, 14.0 minutes; p=0.028). No significant difference was observed in the rate of successful ECMO weaning (daytime, 48.3%; nighttime, 39.5%; weekend, 36.1%; p=0.375). Conclusion: In situations involving CPR, the time to arrival of the ECMO team was longer during off hours. Furthermore, ECMO insertion required more time at night than during the other periods. These findings warrant specific training in decision-making and emergent ECMO insertion.

6.
J Chest Surg ; 57(2): 184-194, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38360679

RESUMO

Background: Left ventricular assist devices (LVADs) are widely employed as a therapeutic option for end-stage heart failure. We evaluated the outcomes associated with centrifugal-flow LVAD implantation, comparing 2 device models: the Heartmate 3 (HM3) and the Heartware Ventricular Assist Device (HVAD). Methods: Data were collected from patients who underwent LVAD implantation between June 1, 2015 and December 31, 2022. We analyzed overall survival, first rehospitalization, and early, late, and LVAD-related complications. Results: In total, 74 patients underwent LVAD implantation, with 42 receiving the HM3 and 32 the HVAD. A mild Interagency Registry for Mechanically Assisted Circulatory Support score was more common among HM3 than HVAD recipients (p=0.006), and patients receiving the HM3 exhibited lower rates of preoperative ventilator use (p=0.010) and extracorporeal membrane oxygenation (p=0.039). The overall early mortality rate was 5.4% (4 of 74 patients), with no significant difference between groups. Regarding early right ventricular (RV) failure, HM3 implantation was associated with a lower rate (13 of 42 [31.0%]) than HVAD implantation (18 of 32 [56.2%], p=0.051). The median rehospitalization-free period was longer for HM3 recipients (16.9 months) than HVAD recipients (5.3 months, p=0.013). Furthermore, HM3 recipients displayed a lower incidence of late hemorrhagic stroke (p=0.016). In the multivariable analysis, preoperative use of continuous renal replacement therapy (odds ratio, 22.31; p=0.002) was the only significant predictor of postoperative RV failure. Conclusion: The LVAD models (HM3 and HVAD) demonstrated comparable overall survival rates. However, the HM3 was associated with a lower risk of late hemorrhagic stroke.

7.
Ann Vasc Surg ; 27(4): 487-96, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23540676

RESUMO

BACKGROUND: Poor endothelialization and intimal hyperplasia are major causes of small diameter vascular conduit (SDVC) failure. The present study was aimed to investigate the influence of granulocyte colony-stimulating factor (G-CSF) on inhibiting adverse remodeling of decellularized SDVCs. METHODS: Sprague-Dawley rats implanted with allograft infra renal abdominal aortic conduits were divided into 2 groups according to whether they were treated with G-CSF (+G-CSF group; n=6) or without (Decell group; n=6). The conduits were harvested at 8 weeks after surgery and examined for intimal hyperplasia, collagen deposition, and -actin-staining cells. The medial layer was also examined for signs of cellular repopulation and changes in the elastic fiber morphology. RESULTS: Intergroup comparison of the intimal composition showed relatively sparse collagen content and predominance of -actin-staining cells in the +G-CSF group. The medial layer in the 2 groups showed similar degrees of elastic fiber degeneration and wall thinning relative to the normal aortic wall. However, the enhanced staining for von Willebrand factor and CD31, along with transmission electron microscopy findings of superior cellular and ultrastructural preservation, suggested that the remodeling and endothelialization in the +G-CSF conduits were superior to those in the Decell conduits. CONCLUSIONS: This study suggests that G-CSF exerts a positive influence on inhibiting adverse vascular remodeling of decellularized vascular conduit implants. However, whether G-CSF administration may also effectuate an improved ability to preserve the medial structural integrity is unclear.


Assuntos
Aorta Abdominal/cirurgia , Prótese Vascular , Fator Estimulador de Colônias de Granulócitos/farmacologia , Túnica Íntima/efeitos dos fármacos , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Animais , Modelos Animais de Doenças , Feminino , Hiperplasia , Imuno-Histoquímica , Ratos , Ratos Sprague-Dawley , Túnica Íntima/patologia
9.
J Card Surg ; 28(3): 212-7, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23488674

RESUMO

BACKGROUND: The purpose of this study was to evaluate the clinical outcomes and risk of tricuspid valve replacements and to compare bioprosthetic versus mechanical valves. METHODS: Between 1991 and 2009, 104 consecutive patients (71 women; mean age, 57 ± 10.8 years) with tricuspid valvular disease underwent mechanical TVR (mechanical group; n = 59) or bioprosthetic TVR (bioprosthesis group; n = 45). Follow-up was complete in 97.1% (n = 101) with a median duration of 49.9 months (range 0-230 months). RESULTS: Hospital mortality after mechanical TVR and bioprosthetic TVR was not different on adjusted analysis by propensity score. Ten-year actuarial survival after mechanical and bioprosthetic TVR was 83.9 ± 7.6% and 61.4 ± 9.1%, respectively (p = 0.004). However, there was also no significant difference in terms of adjusted analysis by propensity score (p = 0.084). No statistically significant difference was detected between mechanical and bioprosthetic valves in regard to event-free survival. CONCLUSIONS: Mechanical TVR is not inferior to bioprosthetic TVR in terms of occurrence of valve-related events, especially anticoagulation-related complications.


Assuntos
Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/etiologia , Valva Tricúspide/cirurgia , Análise Atuarial , Adulto , Idoso , Causas de Morte , Comorbidade , Feminino , Seguimentos , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Reoperação , Análise de Sobrevida
10.
J Chest Surg ; 56(6): 394-402, 2023 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-37696780

RESUMO

Background: The optimal choice of valve substitute for aortic valve replacement (AVR) in pediatric patients remains a matter of debate. This study investigated the outcomes following AVR using mechanical prostheses in children. Methods: Forty-four patients younger than 15 years who underwent mechanical AVR from March 1990 through March 2023 were included. The outcomes of interest were death or transplantation, hemorrhagic or thromboembolic events, and reoperation after mechanical AVR. Adverse events included any death, transplant, aortic valve reoperation, and major thromboembolic or hemorrhagic event. Results: The median age and weight at AVR were 139 months and 32 kg, respectively. The median follow-up duration was 56 months. The most commonly used valve size was 21 mm (14 [31.8%]). There were 2 in-hospital deaths, 1 in-hospital transplant, and 1 late death. The overall survival rates at 1 and 10 years post-AVR were 92.9% and 90.0%, respectively. Aortic valve reoperation was required in 4 patients at a median of 70 months post-AVR. No major hemorrhagic or thromboembolic events occurred. The 5- and 10-year adverse event-free survival rates were 81.8% and 72.2%, respectively. In univariable analysis, younger age, longer cardiopulmonary bypass time, and smaller valve size were associated with adverse events. The cut-off values for age and prosthetic valve size to minimize the risk of adverse events were 71 months and 20 mm, respectively. Conclusion: Mechanical AVR could be performed safely in children. Younger age, longer cardiopulmonary bypass time and smaller valve size were associated with adverse events. Thromboembolic or hemorrhagic complications might rarely occur.

11.
J Chest Surg ; 56(1): 25-32, 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36517949

RESUMO

Background: We reviewed the clinical outcomes of patients with oligometastatic (OM) non-small cell lung cancer (NSCLC) who received multimodal therapy including lung surgery. Methods: We retrospectively analyzed 117 patients with OM NSCLC who underwent complete resection of the primary tumor from 2014 to 2017. Results: The median follow-up duration was 2.91 years (95% confidence interval, 1.48-5.84 years). The patients included 73 men (62.4%), and 76 patients (64.9%) were under the age of 65 years. Based on histology, 97 adenocarcinomas and 14 squamous cell carcinomas were included. Biomarker analysis revealed that 53 patients tested positive for epidermal growth factor receptor, anaplastic lymphoma kinase, or ROS1 mutations, while 36 patients tested negative. Metastases were detected in the brain in 74 patients, the adrenal glands in 12 patients, bone in 5 patients, vertebrae in 4 patients, and other locations in 12 patients. Radiation therapy for organ metastasis was performed in 81 patients and surgical resection in 27 patients. The 1-year overall survival (OS) rate in these patients was 82.8%, and the 3- and 5-year OS rates were 52.6% and 37.2%, respectively. Patients with positive biomarker test results had 1-, 3-, and 5-year OS rates of 98%, 64%, and 42.7%, respectively. These patients had better OS than those with negative biomarker test results (p=0.031). Patients aged ≤65 years and those with pT1-2 cancers also showed better survival (both p=0.008). Conclusion: Surgical resection of primary lung cancer is a viable treatment option for selected patients with OM NSCLC in the context of multimodal therapy.

12.
J Card Surg ; 27(5): 567-70, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22762274
13.
Polymers (Basel) ; 14(6)2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35335503

RESUMO

Hydrogen is nowadays considered a favorable and attractive energy carrier fuel to replace other fuels that cause global warming problems. Water electrolysis has attracted the attention of researchers to produce green hydrogen mainly for the accumulation of renewable energy. Hydrogen can be safely used as a bridge to successfully connect the energy demand and supply divisions. An alkaline water electrolysis system owing to its low cost can efficiently use renewable energy sources on large scale. Normally organic/inorganic composite porous separator membranes have been employed as a membrane for alkaline water electrolyzers. However, the separator membranes exhibit high ionic resistance and low gas resistance values, resulting in lower efficiency and raised safety issues as well. Here, in this study, we report that zirconia toughened alumina (ZTA)-based separator membrane exhibits less ohmic resistance 0.15 Ω·cm2 and low hydrogen gas permeability 10.7 × 10-12 mol cm-1 s-1 bar-1 in 30 wt.% KOH solution, which outperforms the commercial, state-of-the-art Zirfon® PERL separator. The cell containing ZTA and advanced catalysts exhibit an excellent performance of 2.1 V at 2000 mA/cm2 at 30 wt.% KOH and 80 °C, which is comparable with PEM electrolysis. These improved results show that AWEs equipped with ZTA separators could be superior in performance to PEM electrolysis.

14.
J Card Surg ; 26(6): 579-85, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21972985

RESUMO

BACKGROUND: The aim of this study was to compare the results of all arterial multivessel coronary artery bypass grafting using the left internal thoracic artery composite bypass graft constructed with the right internal thoracic artery or radial artery. METHODS: Patients undergoing coronary artery bypass grafting with a left internal thoracic artery constructed as a composite bypass graft with either a right internal thoracic artery (n = 45; RITA group) or radial artery (n = 352; RA group) between 2003 and 2009 were included in the present study. RESULTS: The three-year patency rates for the RITA and RA groups were 91.8%± 4.3% and 78.6%± 3.4%, respectively (p = 0.12). Adjustments for covariates revealed the radial artery patency to be significantly inferior to the right internal thoracic artery graft (hazard ratio 4.35, 95% confidence interval 1.05 to 18.0; p = 0.043). Reintervention for target coronary artery occlusion was required in two patients in the RA group over a mean follow-up period of 35.5 ± 21.5 months. There were 43 deaths in the entire cohort of which 20 were cardiac. After adjustment for significant variables, the risk of all-cause mortality, cardiac death, and the composite of adverse events (death, reintervention, myocardial infarction, and stroke) were similar for the two groups (p = 0.98, 0.99, and 0.21, respectively). CONCLUSIONS: Although superior patency was observed with the right internal thoracic artery over the radial artery graft, a significant commensurate benefit in reducing the incidence of major adverse clinical outcomes was not necessarily shown.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Artéria Torácica Interna/transplante , Artéria Radial/transplante , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Korean J Thorac Cardiovasc Surg ; 54(3): 221-223, 2021 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-33173019

RESUMO

Giant coronary artery aneurysms are rare and challenging to treat because of variation in the presenting symptoms and the lack of established management guidelines. We report the case of a patient with a 6-cm-wide giant coronary artery aneurysm that was resected, followed by reconstruction using a saphenous vein graft and 18 years of follow-up.

16.
J Chest Surg ; 54(5): 348-355, 2021 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-34611083

RESUMO

BACKGROUND: Congenital diaphragmatic hernia (CDH) is a rare disease often requiring mechanical ventilation after birth. In severe cases, extracorporeal membrane oxygenation (ECMO) may be needed. This study analyzed the outcomes of patients with CDH treated with ECMO and investigated factors related to in-hospital mortality. METHODS: Among 254 newborns diagnosed with CDH between 2008 and 2020, 51 patients needed ECMO support. At Asan Medical Center, a multidisciplinary team approach has been applied for managing newborns with CDH since 2018. Outcomes were compared between hospital survivors and nonsurvivors. RESULTS: ECMO was established at a median of 17 hours after birth. The mean birth weight was 3.1±0.5 kg. Twenty-three patients (23/51, 45.1%) were weaned from ECMO, and 16 patients (16/51, 31.4%) survived to discharge. The ECMO mode was veno-venous in 24 patients (47.1%) and veno-arterial in 27 patients (52.9%). Most cannulations (50/51, 98%) were accomplished through a transverse cervical incision. No significant between-group differences in baseline characteristics and prenatal indices were observed. The oxygenation index (1 hour before: 90.0 vs. 51.0, p=0.005) and blood lactate level (peak: 7.9 vs. 5.2 mmol/L, p=0.023) before ECMO were higher in nonsurvivors. Major bleeding during ECMO more frequently occurred in nonsurvivors (57.1% vs. 12.5%, p=0.007). In the multivariate analysis, the oxygenation index measured at 1 hour before ECMO initiation was identified as a significant risk factor for in-hospital mortality (odds ratio, 1.02; 95% confidence interval, 1.01-1.04; p=0.05). CONCLUSION: The survival of neonates after ECMO for CDH is suboptimal. Timely application of ECMO is crucial for better survival outcomes.

17.
Front Chem ; 9: 787787, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869233

RESUMO

Alkaline water electrolysis (AWE) is a mature water electrolysis technology that can produce green hydrogen most economically. This is mainly attributed to the use of Ni-based materials that are easy to process and inexpensive. The nickel-based meshes with various structures such as woven mesh and expanded mesh are widely used as electrode in the AWE due to its common availability and easy fabrication. However, the morphological effect of meshes on hydrogen evolution reaction (HER) performance has not been studied. Here a new parameter to determine the structural effect of mesh on HER performance was first proposed. The key factors of the parameter were found to be the strand width, pore width and the strand surface area. The woven mesh with the ratio of pore width to strand width that converges to 1 showed the lowest the overpotential. The expanded mesh with the higher the structural surface area exhibited the lowest the overpotential. This study will help to choose an optimal structure for the mesh with the HER electrode.

18.
J Korean Med Sci ; 25(10): 1467-72, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20890428

RESUMO

The study aim was to compare maze outcomes using microwave ablation or cryoablation in patients with mitral disease and atrial fibrillation (AF). Between 1999 and 2005, 340 patients underwent mitral valve surgery and concomitant maze procedure involving either microwave ablation (n=96, MW group) or cryoablation (n=244, Cryo group). Mean age at operation was 50.0±12.5 yr. Follow-up period was 46.1±28.2 months. The Cryo group showed a longer aortic clamping time than the MW group (P=0.005). There were no differences in operative mortality and morbidity rates. The unadjusted 5-yr AF free rate was 61.3±1.2% in the MW group and 79.9±3.2% in the Cryo group (P=0.089). After adjustment, the MW group only showed a tendency toward more frequent AF recurrence than the Cryo group (Hazard ration 1.66, 95% confidence interval 0.89 to 3.07). Multivariate analysis revealed that older patient age (P<0.001) and greater left atrial size (P<0.001) were independent risk factors for AF recurrence. Although the use of microwave ablation results in shorter aortic clamping time, it has a tendency toward more frequent late AF recurrence than with cryoablation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Micro-Ondas , Valva Mitral/cirurgia , Adulto , Idoso , Fibrilação Atrial/mortalidade , Fibrilação Atrial/terapia , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
19.
Korean J Thorac Cardiovasc Surg ; 53(5): 297-300, 2020 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-32919452

RESUMO

BACKGROUND: This study aimed to assess the effect of vessel size and flow characteristics on the maturation of autogenous radiocephalic arteriovenous fistulae (RCAVFs). METHODS: We retrospectively reviewed records of patients undergoing RCAVF creation at a single medical center from January 2013 to December 2019. Operative variables were compared between patients whose fistulae matured and those whose fistulae failed to mature. RESULTS: Overall, 152 patients (33 of whom were women) with a mean age of 62.6±13.6 years underwent RCAVF creation; functional maturation was achieved in 123. No statistically significant differences were observed between patients in whom maturation was or was not achieved in terms of the following variables: female sex (20.3% vs. 25.0%), radial artery size (2.5 vs. 2.4 mm), and pulsatility index (0.69 vs. 0.62). Low intraoperative transit time flowmetry (TTF; 150.4 vs. 98.1 mL/min) and small vein size (2.4 vs. 2.0 mm) were associated with failure of maturation. The best cutoff diameter for RCAVF TTF and cephalic vein size were 105 mL/min and 2.45 mm, respectively. CONCLUSION: In patients who undergo RCAVF creation, vein diameter on preoperative ultrasonography and intraoperative TTF are predictors of functional maturation. We identified an intraoperative TTF cutoff value that can be used for intraoperative decision-making.

20.
Polymers (Basel) ; 12(12)2020 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-33261186

RESUMO

The intermittent and volatile nature of renewable energy sources threatens the stable operation of power grids, necessitating dynamically operated energy storage. Power-to-gas technology is a promising method for managing electricity variations on a large gigawatt (GW) scale. The electrolyzer is a key component that can convert excess electricity into hydrogen with high flexibility. Recently, organic/inorganic composite separators have been widely used as diaphragm membranes; however, they are prone to increase ohmic resistance and gas crossover, which inhibit electrolyzer efficiency. Here, we show that the ceria nanoparticle and polysulfone composite separator exhibits a low area resistance of 0.16 Ω cm2 and a hydrogen permeability of 1.2 × 10-12 mol cm-1 s-1 bar-1 in 30 wt% potassium hydroxide (KOH) electrolyte, which outperformed the commercial separator, the Zirfon PERL separator. The cell using a 100 nm ceria nanoparticle/polysulfone separator and advanced catalysts has a remarkable capability of 1.84 V at 800 mA cm-2 at 30 wt% and 80 °C. The decrease in the average pore size of 77 nm and high wettability (contact angle 75°) contributed to the reduced ohmic resistance and low gas crossover. These results demonstrate that the use of ceria nanoparticle-based separators can achieve high performance compared to commercial zirconia-based separators.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA