Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Proc Natl Acad Sci U S A ; 112(5): 1304-9, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25605946

RESUMO

The spatial coherence of laser sources has limited their application to parallel imaging and projection due to coherent artifacts, such as speckle. In contrast, traditional incoherent light sources, such as thermal sources or light emitting diodes (LEDs), provide relatively low power per independent spatial mode. Here, we present a chip-scale, electrically pumped semiconductor laser based on a novel design, demonstrating high power per mode with much lower spatial coherence than conventional laser sources. The laser resonator was fabricated with a chaotic, D-shaped cavity optimized to achieve highly multimode lasing. Lasing occurs simultaneously and independently in ∼1,000 modes, and hence the total emission exhibits very low spatial coherence. Speckle-free full-field imaging is demonstrated using the chaotic cavity laser as the illumination source. The power per mode of the sample illumination is several orders of magnitude higher than that of a LED or thermal light source. Such a compact, low-cost source, which combines the low spatial coherence of a LED with the high spectral radiance of a laser, could enable a wide range of high-speed, full-field imaging and projection applications.


Assuntos
Lasers , Semicondutores
2.
Opt Lett ; 42(3): 411-414, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28146489

RESUMO

We develop a green light source with low spatial coherence via intracavity frequency doubling of a solid-state degenerate laser. The second-harmonic emission supports many more transverse modes than the fundamental emission, and exhibits lower spatial coherence. A strong suppression of speckle formation is demonstrated for both fundamental and second-harmonic beams. Using the green emission for fluorescence excitation, we show the coherent artifacts are removed from the full-field fluorescence images. The high power, low spatial coherence, and good directionality make the green degenerate laser an attractive illumination source for parallel imaging and projection display.

3.
Lasers Surg Med ; 49(3): 270-279, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28231402

RESUMO

BACKGROUND AND OBJECTIVE: Cilia-driven mucociliary clearance is an important self-defense mechanism of great clinical importance in pulmonary research. Conventional light microscopy possesses the capability to visualize individual cilia and its beating pattern but lacks the throughput to assess the global ciliary activities and flow dynamics. Optical coherence tomography (OCT), which provides depth-resolved cross-sectional images, was recently introduced to this area. MATERIALS AND METHODS: Fourteen de-identified human tracheobronchial tissues are directly imaged by two OCT systems: one system centered at 1,300 nm with 6.5 µm axial resolution and 15 µm lateral resolution, and the other centered at 800 nm with 2.72 µm axial resolution and 5.52 µm lateral resolution. Speckle variance images are obtained in both cross-sectional and volumetric modes. After imaging, sample blocks are sliced along the registered OCT imaging plane and processed with hematoxylin and eosin (H&E) stain for comparison. Quantitative flow analysis is performed by tracking the path-lines of microspheres in a fixed cross-section. Both the flow rate and flow direction are characterized. RESULTS: The speckle variance images successfully segment the ciliated epithelial tissue from its cilia-denuded counterpart, and the results are validated by corresponding H&E stained sections. A further temporal frequency analysis is performed to extract the ciliary beat frequency (CBF) at cilia cites. By adding polyester microspheres as contrast agents, we demonstrate ex vivo imaging of the flow induced by cilia activities of human tracheobronchial samples. CONCLUSION: This manuscript presents an ex vivo study on human tracheobronchial ciliated epithelium and its induced mucous flow by using OCT. Within OCT images, intact ciliated epithelium is effectively distinguished from cilia-denuded counterpart, which serves as a negative control, by examining the speckle variance images. The cilia beat frequency is extracted by temporal frequency analysis. The flow rate, flow direction, and particle throughput are obtained through particle tracking. The availability of these quantitative parameters provides us with a powerful tool that will be useful for studying the physiology, pathophysiology and the effectiveness of therapies on epithelial cilia function, as well as serve as a diagnostic tool for diseases associated with ciliary dysmotility. Lasers Surg. Med. 49:270-279, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Sistema Respiratório/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Biópsia por Agulha , Cílios/patologia , Epitélio/diagnóstico por imagem , Epitélio/patologia , Humanos , Imageamento Tridimensional/métodos , Imuno-Histoquímica , Técnicas In Vitro , Depuração Mucociliar/fisiologia , Sistema Respiratório/patologia , Estudos de Amostragem , Sensibilidade e Especificidade , Técnicas de Cultura de Tecidos
4.
Opt Express ; 24(9): 9251-65, 2016 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-27137541

RESUMO

We present a high-speed and phase-sensitive reflectance line-scanning confocal holographic microscope (LCHM). We achieved rapid confocal imaging using a fast line-scan CCD camera and quantitative phase imaging using off-axis digital holography (DH) on a 1D, line-by-line basis in our prototype experiment. Using a 20 kHz line scan rate, we achieved a frame rate of 20 Hz for 512x512 pixels en-face confocal images. We realized coherent holographic detection two different ways. We first present a LCHM using off-axis configuration. By using a microscope objective of a NA 0.65, we achieved axial and lateral resolution of ~3.5 micrometers and ~0.8 micrometers, respectively. We demonstrated surface profile measurement of a phase target at nanometer precision and the digital refocusing of a defocused confocal en-face image. Ultrahigh temporal resolution M mode is demonstrated by measuring the vibration of a PZT-actuated mirror driven by a sine wave at 1 kHz. We then report our experimental work on a LCHM using an in-line configuration. In this in-line LCHM, the coherent detection is enabled by moving the reference arm at a constant speed, thereby introducing a Doppler frequency shift that leads to spatial interference fringes along the scanning direction. Lastly, we present a unified formulation that treats off-axis and in-line LCHM in a unified joint spatiotemporal modulation framework and provide a connection between LCHM and the traditional off-axis DH. The presented high-speed LCHM may find applications in optical metrology and biomedical imaging.

5.
Opt Lett ; 41(20): 4775-4778, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28005890

RESUMO

Line-field reflection confocal microscopy (LF-RCM) has the potential to add a dimension of parallelization to traditional confocal microscopy while reducing the need for two-axis beam scanning. LF-RCM systems often employ light sources with a high degree of spatial coherence. This high degree of spatial coherence potentially leads to unwanted coherent artifact in the setting of nontrivial sample scattering. Here, we (a) confirm that a coherent artifact is a nontrivial problem in LF-RCM when using spatially coherent light, and (b) demonstrate that such a coherent artifact can be mitigated through the use of reduced spatial coherence line-field sources. We demonstrate coherent noise suppression in a full-pupil line-field confocal microscope using a large number of mutually incoherent emitters from a vertical-cavity surface-emitting lasers (VCSEL) array. The coherent noise from a highly scattering sample is significantly suppressed by the use of this synthesized reduced spatial coherence light source compared to a fully coherent light source. Lastly, with scattering samples, the axial confocality of line-field confocal microscopy is compromised independent of the source spatial coherence, as demonstrated by our experimental result. Our results highlight the importance of spatial coherence engineering in parallelized reflection confocal microscopy.

6.
Opt Lett ; 41(9): 2029-32, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27128066

RESUMO

A general-purpose all-fiber spectrometer is demonstrated to overcome the trade-off between spectral resolution and bandwidth. By integrating a wavelength division multiplexer with five multimode optical fibers, we have achieved 100 nm bandwidth with 0.03 nm resolution at wavelength 1500 nm. An efficient algorithm is developed to reconstruct the spectrum from the speckle pattern produced by interference of guided modes in the multimode fibers. Such an algorithm enables a rapid, accurate reconstruction of both sparse and dense spectra in the presence of noise.

7.
Cell Mol Life Sci ; 72(6): 1095-113, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25417211

RESUMO

Cilia-driven fluid flow is important for multiple processes in the body, including respiratory mucus clearance, gamete transport in the oviduct, right-left patterning in the embryonic node, and cerebrospinal fluid circulation. Multiple imaging techniques have been applied toward quantifying ciliary flow. Here, we review common velocimetry methods of quantifying fluid flow. We then discuss four important optical modalities, including light microscopy, epifluorescence, confocal microscopy, and optical coherence tomography, that have been used to investigate cilia-driven flow.


Assuntos
Cílios/fisiologia , Cílios/ultraestrutura , Imagem Óptica/métodos , Reologia/métodos , Animais , Corantes/análise , Desenho de Equipamento , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microscopia/instrumentação , Microscopia/métodos , Imagem Óptica/instrumentação , Reologia/instrumentação , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos
8.
Opt Lett ; 40(20): 4607-10, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26469575

RESUMO

We design and demonstrate a fiber-based amplified spontaneous emission (ASE) source with low spatial coherence, low temporal coherence, and high power per mode. ASE is produced by optically pumping a large gain core multimode fiber while minimizing optical feedback to avoid lasing. The fiber ASE source provides 270 mW of continuous wave emission, centered at λ=1055 nm, with a full width at half-maximum bandwidth of 74 nm. The emission is distributed among as many as ∼70 spatial modes, enabling efficient speckle suppression when combined with spectral compounding. Finally, we demonstrate speckle-free full-field imaging using the fiber ASE source. The fiber ASE source provides a unique combination of high power per mode with both low spatial and low temporal coherence, making it an ideal source for full-field imaging and ranging applications.


Assuntos
Fibras Ópticas , Imagem Óptica/instrumentação
9.
Proc Natl Acad Sci U S A ; 109(6): 2021-6, 2012 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-22308353

RESUMO

The cilium serves as a cellular antenna by coordinating upstream environmental cues with numerous downstream signaling processes that are indispensable for the function of the cell. This role is supported by the revelation that defects of the cilium underlie an emerging class of human disorders, termed "ciliopathies." Although mounting interest in the cilium has demonstrated the essential role that the organelle plays in vertebrate development, homeostasis, and disease pathogenesis, the mechanisms regulating cilia morphology and function remain unclear. Here, we show that the target-of-rapamycin (TOR) growth pathway modulates cilia size and function during zebrafish development. Knockdown of tuberous sclerosis complex 1a (tsc1a), which encodes an upstream inhibitor of TOR complex 1 (Torc1), increases cilia length. In contrast, treatment of embryos with rapamycin, an inhibitor of Torc1, shortens cilia length. Overexpression of ribosomal protein S6 kinase 1 (S6k1), which encodes a downstream substrate of Torc1, lengthens cilia. Furthermore, we provide evidence that TOR-mediated cilia assembly is evolutionarily conserved and that protein synthesis is essential for this regulation. Finally, we demonstrate that TOR signaling and cilia length are pivotal for a variety of downstream ciliary functions, such as cilia motility, fluid flow generation, and the establishment of left-right body asymmetry. Our findings reveal a unique role for the TOR pathway in regulating cilia size through protein synthesis and suggest that appropriate and defined lengths are necessary for proper function of the cilium.


Assuntos
Cílios/metabolismo , Biossíntese de Proteínas , Transdução de Sinais , Fatores de Transcrição/metabolismo , Proteínas de Peixe-Zebra/metabolismo , Animais , Padronização Corporal , Cílios/enzimologia , Evolução Molecular , Técnicas de Silenciamento de Genes , Quinase 3 da Glicogênio Sintase/metabolismo , Glicogênio Sintase Quinase 3 beta , Humanos , Movimento , Tamanho do Órgão , Reologia , Proteínas Quinases S6 Ribossômicas/metabolismo , Proteína 1 do Complexo Esclerose Tuberosa , Proteínas Supressoras de Tumor/metabolismo , Peixe-Zebra
10.
Opt Lett ; 39(3): 521-4, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24487855

RESUMO

Dynamic light scattering-based optical coherence tomography approaches have been successfully implemented to measure total transverse (xy) flow speed, but are unable to resolve directionality. We propose a method to extract directional velocity in the transverse plane by introducing a variable scan bias to our system. Our velocity estimation, which yields the directional velocity component along the scan axis, is also independent of any point-spread function calibration. By combining our approach with Doppler velocimetry, we show three-component velocimetry that is appropriately dependent on latitudinal and longitudinal angle.


Assuntos
Luz , Movimento (Física) , Espalhamento de Radiação , Tomografia de Coerência Óptica/métodos
11.
Opt Lett ; 39(15): 4446-9, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25078199

RESUMO

We present an interferometric confocal microscope using an array of 1200 vertical cavity surface emitting lasers (VCSELs) coupled to a multimode fiber. Spatial coherence gating provides ~18,000 continuous virtual pinholes, allowing an entire en face plane to be imaged in a snapshot. This approach maintains the same optical sectioning as a scanning confocal microscope without moving parts, while the high power of the VCSEL array (∼5 mW per laser) enables high-speed image acquisition with integration times as short as 100 µs. Interferometric detection also recovers the phase of the image, enabling quantitative phase measurements and improving the contrast when imaging phase objects.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Aumento da Imagem/instrumentação , Interferometria/instrumentação , Microscopia Confocal/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
12.
Appl Opt ; 53(3): 410-7, 2014 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-24514126

RESUMO

Speckle patterns produced by a disordered medium or a multimode fiber can be used as a fingerprint to uniquely identify the input light frequency. Reconstruction of a probe spectrum from the speckle pattern has enabled the realization of compact, low-cost, and high-resolution spectrometers. Here we investigate the effects of experimental noise on the accuracy of the reconstructed spectra. We compare the accuracy of a speckle-based spectrometer to a traditional grating-based spectrometer as a function of the probe signal intensity and bandwidth. We find that the speckle-based spectrometers provide comparable performance to a grating-based spectrometer when measuring intense or narrowband probe signals, whereas the accuracy degrades in the measurement of weak or broadband signals. These results are important to identify the applications that would most benefit from this new class of spectrometer.


Assuntos
Algoritmos , Artefatos , Tecnologia de Fibra Óptica/instrumentação , Reconhecimento Automatizado de Padrão/métodos , Análise Espectral/instrumentação , Análise Espectral/métodos , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Luz , Espalhamento de Radiação , Razão Sinal-Ruído
13.
Opt Lett ; 37(14): 2979-81, 2012 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-22825198

RESUMO

The genetic basis of congenital heart disease is yet to be defined, and the interactions between the malformed heart and biomechanical cardiac performance remain poorly understood. Functional optical imaging enables detailed biomechanical phenotyping of cardiac dysfunction in small animal models, which in turn enables specific gene-phenotype relationship. We have developed a new microangiography technique based on flow imaging using endogenous hemoglobin contrast enabling in vivo assessment and biomechanical phenotyping of Xenopus tropicalis embryonic heart. We demonstrated that hemoglobin contrast angiography can be used to quantify physiological response to treatment with well-established cardioactive drugs.


Assuntos
Angiografia Digital/métodos , Circulação Sanguínea , Embrião não Mamífero/irrigação sanguínea , Embrião não Mamífero/diagnóstico por imagem , Coração/diagnóstico por imagem , Hemoglobinas/metabolismo , Animais , Xenopus/embriologia
14.
Opt Lett ; 36(17): 3404-6, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21886225

RESUMO

We experimentally studied the spatial coherence of random laser emission from dye solutions containing nanoparticles. The spatial coherence, measured in a double slit experiment, varied significantly with the density of scatterers and the size and shape of the excitation volume. A qualitative explanation is provided, illustrating the dramatic difference from the spatial coherence of a conventional laser. This work demonstrates that random lasers can be controlled to provide intense, spatially incoherent emission for applications in which spatial cross talk or speckle limit performance.


Assuntos
Lasers , Fenômenos Ópticos , Medições Luminescentes
15.
Front Physiol ; 10: 1197, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31620018

RESUMO

Congenital heart disease (CHD) is a significant cause of mortality in infants and adults. Currently human genomic analysis has identified a number of candidate genes in these patients. These genes span diverse categories of gene function suggesting that despite the similarity in cardiac lesion, the underlying pathophysiology may be different. In fact, patients with similar CHDs can have drastically different outcomes, including a dramatic decrease in myocardial function. To test these human candidate genes for their impact on myocardial function, we need efficient animals models of disease. For this purpose, we paired Xenopus tropicalis with our microangiography technique, hemoglobin contrast subtraction angiography (HCSA). To demonstrate the gene-teratogen-physiology relationship, we modeled human cardiomyopathy in tadpoles. First we depleted the sarcomeric protein myosin heavy chain 6 (myh6) expression using morpholino oligos. Next, we exposed developing embryos to the teratogen ethanol and in both conditions showed varying degrees of cardiac dysfunction. Our results demonstrate that HCSA can distinguish biomechanical phenotypes in the context of gene dysfunction or teratogen. This approach can be used to screen numerous candidate CHD genes or suspected teratogens for their effect on cardiac function.

16.
J Biomed Opt ; 24(1): 1-4, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30701725

RESUMO

Optical coherence tomography (OCT) is an emerging technology for in vivo airway and lung imaging. However, OCT lacks sensitivity to the metabolic changes caused by inflammation, which drives chronic respiratory diseases such as asthma and chronic obstructive pulmonary disorder. Redox imaging (RI) is a label-free technique that uses the autofluorescence of the metabolic coenzymes NAD(P)H and flavin adenine dinucleotide (FAD) to probe cellular metabolism and could provide complimentary information to OCT for airway and lung imaging. We demonstrate OCT and RI of respiratory ciliated epithelial function in ex vivo mouse tracheae. We applied RI to measure cellular metabolism via the redox ratio [intensity of NAD(P)H divided by FAD] and particle tracking velocimetry OCT to quantify cilia-driven fluid flow. To model mitochondrial dysfunction, a key aspect of the inflammatory process, cyanide was used to inhibit oxidative metabolism and reduce ciliary motility. Cyanide exposure over 20 min significantly increased the redox ratio and reversed cilia-driven fluid flow. We propose that RI provides complementary information to OCT to assess inflammation in the airway and lungs.


Assuntos
Cílios/patologia , Oxirredução , Mucosa Respiratória/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Traqueia/diagnóstico por imagem , Animais , Cianetos/química , Feminino , Inflamação , Pulmão/diagnóstico por imagem , Camundongos , Microscopia de Fluorescência/métodos , Estresse Oxidativo , Reologia/métodos
17.
Biol Open ; 8(8)2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31455664

RESUMO

Establishing connections between changes in linear DNA sequences and complex downstream mesoscopic pathology remains a major challenge in biology. Herein, we report a novel, multi-modal and multiscale imaging approach for comprehensive assessment of cardiovascular physiology in Drosophila melanogaster We employed high-speed angiography, optical coherence tomography (OCT) and confocal microscopy to reveal functional and structural abnormalities in the hdp2 mutant, pre-pupal heart tube and aorta relative to controls. hdp2 harbor a mutation in wupA, which encodes an ortholog of human troponin I (TNNI3). TNNI3 variants frequently engender cardiomyopathy. We demonstrate that the hdp2 aortic and cardiac muscle walls are disrupted and that shorter sarcomeres are associated with smaller, stiffer aortas, which consequently result in increased flow and pulse wave velocities. The mutant hearts also displayed diastolic and latent systolic dysfunction. We conclude that hdp2 pre-pupal hearts are exposed to increased afterload due to aortic hypoplasia. This may in turn contribute to diastolic and subtle systolic dysfunction via vascular-heart tube interaction, which describes the effect of the arterial loading system on cardiac function. Ultimately, the cardiovascular pathophysiology caused by a point mutation in a sarcomeric protein demonstrates that complex and dynamic micro- and mesoscopic phenotypes can be mechanistically explained in a gene sequence- and molecular-specific manner.

18.
J Biomed Opt ; 12(4): 044008, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17867812

RESUMO

We present spectral domain phase microscopy (SDPM) as a new tool for measurements at the cellular scale. SDPM is a functional extension of spectral domain optical coherence tomography that allows for the detection of cellular motions and dynamics with nanometer-scale sensitivity in real time. Our goal was to use SDPM to investigate the mechanical properties of the cytoskeleton of MCF-7 cells. Magnetic tweezers were designed to apply a vertical force to ligand-coated magnetic beads attached to integrin receptors on the cell surfaces. SDPM was used to resolve cell surface motions induced by the applied stresses. The cytoskeletal response to an applied force is shown for both normal cells and those with compromised actin networks due to treatment with Cytochalasin D. The cell response data were fit to several models for cytoskeletal rheology, including one- and two-exponential mechanical models, as well as a power law. Finally, we correlated displacement measurements to physical characteristics of individual cells to better compare properties across many cells, reducing the coefficient of variation of extracted model parameters by up to 50%.


Assuntos
Neoplasias da Mama/fisiopatologia , Citoesqueleto , Microfluídica/métodos , Microscopia de Contraste de Fase/métodos , Análise Espectral/métodos , Tomografia de Coerência Óptica/métodos , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Elasticidade , Humanos , Viscosidade
19.
Sci Rep ; 7: 42506, 2017 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-28195132

RESUMO

Birth defects affect 3% of children in the United States. Among the birth defects, congenital heart disease and craniofacial malformations are major causes of mortality and morbidity. Unfortunately, the genetic mechanisms underlying craniocardiac malformations remain largely uncharacterized. To address this, human genomic studies are identifying sequence variations in patients, resulting in numerous candidate genes. However, the molecular mechanisms of pathogenesis for most candidate genes are unknown. Therefore, there is a need for functional analyses in rapid and efficient animal models of human disease. Here, we coupled the frog Xenopus tropicalis with Optical Coherence Tomography (OCT) to create a fast and efficient system for testing craniocardiac candidate genes. OCT can image cross-sections of microscopic structures in vivo at resolutions approaching histology. Here, we identify optimal OCT imaging planes to visualize and quantitate Xenopus heart and facial structures establishing normative data. Next we evaluate known human congenital heart diseases: cardiomyopathy and heterotaxy. Finally, we examine craniofacial defects by a known human teratogen, cyclopamine. We recapitulate human phenotypes readily and quantify the functional and structural defects. Using this approach, we can quickly test human craniocardiac candidate genes for phenocopy as a critical first step towards understanding disease mechanisms of the candidate genes.


Assuntos
Anormalidades Craniofaciais/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Tomografia de Coerência Óptica , Xenopus/anormalidades , Animais , Modelos Animais de Doenças , Ecocardiografia , Crista Neural/anormalidades , Fenótipo
20.
Sci Rep ; 7(1): 15115, 2017 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-29118359

RESUMO

Mucociliary flow is an important defense mechanism in the lung to remove inhaled pathogens and pollutants. Disruption of ciliary flow can lead to respiratory infections. Multiple factors, from drugs to disease can cause an alteration in ciliary flow. However, less attention has been given to injury of the ciliated epithelium. In this study, we show how optical coherence tomography (OCT) can be used to investigate injury to the ciliated epithelium in a multi-contrast setting. We used particle tracking velocimetry (PTV-OCT) to investigate the cilia-driven flow field and 3D speckle variance imaging to investigate size and extent of injury caused to the skin of Xenopus embryos. Two types of injuries are investigated, focal injury caused by mechanical damage and diffuse injury by a calcium chloride shock. We additionally investigate injury and regeneration of cilia to calcium chloride on ex vivo mouse trachea. This work describes how OCT can be used as a tool to investigate injury and regeneration in ciliated epithelium.


Assuntos
Cílios/fisiologia , Epitélio/fisiopatologia , Pele/fisiopatologia , Traqueia/fisiopatologia , Animais , Epitélio/embriologia , Epitélio/lesões , Camundongos Endogâmicos C57BL , Regeneração , Reologia , Pele/embriologia , Pele/lesões , Tomografia de Coerência Óptica , Traqueia/diagnóstico por imagem , Traqueia/lesões , Xenopus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA