Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 141(6): 1355-61, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21227471

RESUMO

OBJECTIVES: Our objective was to determine the feasibility and early to medium-term outcome of stenting the patent ductus arteriosus at the time of radiofrequency valvotomy in the subgroup of patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle. BACKGROUND: Stenting of the patent ductus arteriosus and radiofrequency valvotomy have been proposed as the initial intervention for patients with intermediate right ventricle inasmuch as the sustainability for biventricular circulation or 1½-ventricle repair is unclear in the early period. METHODS: Between January 2001 and April 2009, of 143 patients with pulmonary atresia and intact ventricular septum, 37 who had bipartite right ventricle underwent radiofrequency valvotomy and stenting of the patent ductus arteriosus as the initial procedure. The mean tricuspid valve z-score was -3.8 ± 2.2 and the mean tricuspid valve/mitral valve ratio was 0.62 ± 0.16. RESULTS: Median age was 10 days (3-65 days) and median weight 3.1 kg (2.4-4.9 kg). There was no procedural mortality. Acute stent thrombosis developed in 1 patient and necessitated emergency systemic-pulmonary shunt. There were 2 early in-hospital deaths owing to low cardiac output syndrome. One late death occurred owing to right ventricular failure after the operation. Survival after the initial procedure was 94% at 6 months and 91% at 5 years. At a median follow-up of 4 years (6 months to 8 years), 17 (48%) attained biventricular circulation with or without other interventions and 9 (26%) achieved 1½-ventricle repair. The freedom from reintervention was 80%, 68%, 58%, and 40% at 1, 2, 3, and 4 years, respectively. CONCLUSIONS: Concomitant stenting of the patent ductus arteriosus at the time of radiofrequency valvotomy in patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle is feasible and safe with encouraging medium-term outcome.


Assuntos
Anormalidades Múltiplas , Cateterismo Cardíaco/instrumentação , Ablação por Cateter , Permeabilidade do Canal Arterial/terapia , Ventrículos do Coração/anormalidades , Atresia Pulmonar/cirurgia , Stents , Septo Interventricular , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/mortalidade , Permeabilidade do Canal Arterial/fisiopatologia , Estudos de Viabilidade , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Malásia , Atresia Pulmonar/complicações , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/mortalidade , Atresia Pulmonar/fisiopatologia , Radiografia Intervencionista , Recuperação de Função Fisiológica , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/fisiopatologia
2.
Cardiol Young ; 15(2): 141-7, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15845156

RESUMO

Some patients with pulmonary atresia with an intact ventricular septum, mild to moderate right ventricular hypoplasia, and a patent infundibulum remain duct dependent on the flow of blood through the arterial duct despite adequate relief of the obstruction within the right ventricular outflow tract. The objective of our study was to review the risk factors for stenting of the patent arterial duct, or construction of a Blalock-Taussig shunt, in the patients with pulmonary atresia and an intact ventricular septum who remain duct-dependent following radiofrequency valvotomy and dilation of the imperforate pulmonary valve. We reviewed the data from 53 patients seen between November 1995 and December 2001. Of the 47 patients who survived, 6 required stenting of the patent arterial duct, while 4 needed construction of a modified Blalock-Taussig shunt to augment the flow of blood to the lungs at a mean of 7 plus or minus 5.7 days following the initial intervention. The remaining 37 patients required no additional procedures. We compared the findings in these two groups. The mean diameter of the tricuspid valve in the patients requiring early reintervention was 8.5 plus or minus 3.7 millimetres, giving a Z-score of -1.1 plus or minus 1.47, whilst those in the group without early reintervention had values of 10.7 plus or minus 2.2 millimetres, giving a Z-score of -0.58 plus or minus 1.18 (p equal to 0.003). No statistically significant differences were found in right ventricular morphology, McGoon ratio, or residual obstruction across the right ventricular outflow tract after decompression of the right ventricle. The diameter of the tricuspid valve, therefore, appears to be the only factor predicting the need for augmentation of flow of blood to the lungs. As just over one-fifth of our survivors required such augmentation, we hypothesize that stenting of the patent arterial duct may be performed as an integral part of primary transcatheter therapy in patients with pulmonary atresia and intact ventricular septum who have moderate right ventricular hypoplasia and a small tricuspid valve.


Assuntos
Ablação por Cateter , Atresia Pulmonar/fisiopatologia , Atresia Pulmonar/cirurgia , Stents , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA