Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 78(2): 023501, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17578107

RESUMO

A flat-field extreme ultraviolet (EUV) spectrometer with a varied line spacing groove grating (1200 grooves/mm at grating center) has been developed to study the emission spectra from highly ionized medium Z impurities in large helical device (LHD). It covers a wavelength range of 50-500 A using a mechanically ruled grating, which was later replaced by a newly developed laminar-type holographic grating for comparative studies. Differences in spectral resolution, intensities of higher order spectra, and sensitivities of the spectrometer were studied between the two gratings by observing the emission spectra of LHD plasmas. Although the achieved resolution was alike between them, i.e., deltalambda approximately 0.24 A at 200 A, the holographic grating was much superior in suppressing the higher order light than the ruled grating. The relative sensitivity between the two gratings was evaluated using continuum radiation from LHD plasmas. As a result, it was found that the holographic grating has a flat response in the full wavelength range, but the sensitivity of the ruled grating drops sharply below 200 A. A new technique for the absolute calibration of the EUV holographic grating spectrometer was tried by combining the continuum radiation with a branching ratio of C IV lines (3p-3s: 5800 A/3p-2s: 312 A), and an accurate absolute sensitivity has been successfully obtained.

2.
Rev Sci Instrum ; 83(12): 123502, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23277982

RESUMO

In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd(2)Fe(14)B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic field of ~0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is ~2 × 10(11) cm(-3), which is around one order of magnitude larger than that of single ring arrangement.

3.
Appl Opt ; 47(2): 135-46, 2008 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-18188193

RESUMO

A flat-field extreme ultraviolet (EUV) spectrometer with a nominal 2400 grooves/mm aberration-corrected ruled grating has been developed to analyze the emission spectrum in the wavelength range of 10 to 130 A from large helical device (LHD) plasmas. Spectral properties such as resolution, sensitivity, contribution of higher-order light, and background stray light have been studied using emission spectra mainly from intrinsic impurities, e.g., C and Fe. It is found that the spectrometer well resolves closely existing spectral lines of highly ionized medium- and high-Z impurities even in a very short wavelength range such as 10 to 20 A. As a result, it allows one to study the charge state distribution of elements in high-temperature fusion plasma. The ruled grating was then replaced by a laminar type holographic grating for the comparative study. The spectral resolution for the ruled grating (Dlambda approximately 0.08 A at 33.73 A) is clearly better than the holographic grating (Dlambda approximately 0.13 A at 33.73 A). Both gratings well suppress the higher-order light, e.g., the second-order light is only less than 11% of the first-order light for C vi(33.73 A). Relative sensitivity calibration with the wavelength has been done using bremsstrahlung continuum from the LHD plasmas. Absolute intensity calibration has been done by comparing the spectral intensities directly with the absolutely calibrated 1200 grooves/mm EUV spectrometer in the overlapping range of 90-120 A due to the absence of a good branching pair in 10-130 A. As a typical result on the present spectrometer well-resolved n=2-3 full transition arrays from Ne- to Li-like ions are measured for Fe and Ti and wavelengths of the spectral array are tabulated for each charge state. Spectroscopic comparison is also made between the 1200 grooves/mm and 2400 grooves/mm gratings in a range of 50-130 A.

4.
Rev Sci Instrum ; 79(10): 10F537, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044679

RESUMO

Spectral characteristics of varied line spacing 2400 grooves/mm gratings used for a flat-field extreme ultraviolet spectrometer have been evaluated to monitor Delta n=1 (n=2-3) transitions from medium-Z impurities in 10-30 A, where many spectral lines from metallic impurities closely exist. For this purpose emission spectra of the Delta n=1 transitions from partially L-shell-ionized Ti and Fe have been measured in large helical device. At first, a ruled and a holographic grating were utilized for the comparative study. Both gratings suppressed higher order light effectively but spectral sensitivity was much higher for the holographic grating. The ruled grating, however, attained better spectral resolution (0.083 A at 18.97 A) in the 10-100 A range compared to that (0.130 A) of the holographic grating. After that a recently developed new holographic grating with different laminar shapes and line spacings has attempted to improve the spectral resolution. As a result, it has considerably improved the spectral resolution in the 10-30 A range, i.e., approximately 0.090 A. However, it is found that the experimentally obtained spectral resolution is quit poor compared to the computationally simulated one, suggesting a technical difficulty in manufacturing exactly the varied line spacing of the holographic grating at such a short wavelength range.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA