Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
World J Urol ; 37(7): 1251-1254, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29616296

RESUMO

Prostate Specific Membrane Antigen Positron Emission Tomography/Computed Tomography (PSMA-PET/CT) has increased the sensitivity and specificity of imaging to identify metastatic prostate cancer in the group of patients with early biochemical recurrence when compared to conventional imaging. In patients who develop biochemical recurrence of prostate cancer following surgical resection, salvage lymph node dissection may reduce prostate specific antigen (PSA) levels and delay the time for commencement of systemic therapies. However, PLND may be an anatomically and technically difficult procedure, particularly with small metastatic diseases which can be problematic for intra-operative identification. We describe the technique using PSMA-PET imaging to pre-operatively localise areas of low-volume nodal metastatic disease with hookwire to allow targeted lymph node dissection with direct visualisation and palpation to ensure adequate clearance of involved nodes.


Assuntos
Excisão de Linfonodo/métodos , Linfonodos/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Linfonodos/cirurgia , Metástase Linfática , Masculino , Glicoproteínas de Membrana , Compostos Organometálicos , Pelve , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico/sangue , Prostatectomia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/cirurgia , Compostos Radiofarmacêuticos , Terapia de Salvação
2.
World J Urol ; 37(5): 799-804, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30191394

RESUMO

PURPOSE: With the rapidly expanding anatomical and technical knowledge surrounding nervesparing radical prostatectomy (NSRP), anatomical and operative textbooks have failed to keep pace with the literature. A surgical skill laboratory (SSL) was designed to educate urology trainees on surgical anatomy and techniques for NSRP. The objective was to assess the validity of a SSL program. METHODS: A low-fidelity, anatomically accurate prostate model with its appropriate fascial coverings and location of the neurovascular bundle was created. Participants were surveyed prior to a SSL workshop for their knowledge of NSRP focusing on clinical and anatomical considerations. An interactive 2-h tutorial and workshop was then undertaken outlining the clinical and anatomical nuances for NSRP, with participants then practising an intra and inter-fascial NSRP on the model. Participants were resurveyed immediately after the workshop and at 6 months. RESULTS: Thirty participants completed the NSRP workshop. Significant differences (p < 0.0001) in anatomical and clinical knowledge were noted after the workshop with improvements for both junior and senior trainees. The knowledge was retained at 6 months following the workshop. CONCLUSIONS: A low-fidelity bench-top model is a feasible and reproducible technique for improving the understanding of periprostatic anatomy and the different surgical approaches for NSRP. The SSL is useful and knowledge gained appears to be retained by workshop participants. SSL workshops are a valid hands-on approach to teaching surgical skills and should remain an integral part of urology training.


Assuntos
Prostatectomia/educação , Neoplasias da Próstata/cirurgia , Urologia/educação , Competência Clínica , Educação , Humanos , Masculino , Tratamentos com Preservação do Órgão , Nervos Periféricos/anatomia & histologia , Próstata/anatomia & histologia , Próstata/cirurgia , Prostatectomia/métodos , Treinamento por Simulação
3.
World J Urol ; 36(12): 2043-2050, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29808300

RESUMO

PURPOSE: To review current practices in manual bladder washouts (MBW) for haematuria with clot retention, comparing those conducted by a urology unit to other inpatient services. Secondly, to describe a standardised protocol for MBWs. METHODS: Prospective data were collected for patients treated for clot retention, from initial management by referral units through to implementation of a standardised MBW by the urology service. Outcomes measured included re-catheterisation, MBW volumes, clot evacuated and time to discharge or subsequent intervention. RESULTS: Initial catheters inserted by referral teams were sized 16 Fr-20 Fr, all except one requiring upsizing. Mean washout volumes of 145 ml (SD 125) and 5392 ml (SD 847) were used by referring units and the urology service, respectively. Mean volume of clot evacuated by the standardised MBW was 617 ml (SD 313). Continuous bladder irrigation (CBI) was commenced in 16 patients (66%) prior to referral to urology. Median time to discharge was 48 h. CONCLUSION: Initial catheter insertion is of inadequate size, as is the volume of washout performed. Referring services fail to clear adequate amounts of clot with washouts posing potential risks to patients. The standard management of clot retention should involve the use of at least a 22 F catheter, implement best practice infection control and adopt the last Clot + 1L rule with catheter manipulation. The key points of our recommended MBW are summarised with the acronym CATCH-22. This protocol can guide initial management of clot retention and be used as an educational tool.


Assuntos
Hematúria/terapia , Encaminhamento e Consulta , Irrigação Terapêutica/métodos , Trombose/terapia , Cateterismo Urinário/métodos , Cateteres Urinários , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
4.
World J Urol ; 36(4): 575-584, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29445846

RESUMO

PURPOSE: Prostatic artery embolization (PAE) has seen a recent increase in interest as a treatment for men with benign prostatic obstruction (BPO). The appeal of this intervention lies in reported reduction in morbidity and its minimally invasive nature. The purpose of this review is to assess the safety and efficacy of PAE as a new treatment in BPO and explore risks surrounding its performance. METHODS: A review of the literature was performed. Medical databases searched included PubMed, EMBASE, and Cochrane databases, limited to English, peer-reviewed articles. Search terms included prostatic artery embolization, lower urinary tracts symptoms, minimally invasive therapies, interventional radiology prostate, and benign prostatic hyperplasia. Articles were screened by two independent reviewers for content on development, methods, outcomes, and complications of PAE. RESULTS: Suitability of patients to undergo PAE depends on review of patient history, pre-procedure visualisation of appropriate vascular anatomy and clinical parameters. Despite this selection of candidates favourable for procedural success, PAE is not without risk of complications, some of which can significantly affect patient quality of life. CONCLUSIONS: Although initial findings show promise regarding safety and efficacy of PAE in improving symptom and quality-of-life scores, further investigation is required to establish durability of effect and the appropriate use of this experimental modality. There is currently limited robust evidence for the beneficial outcomes of PAE. Long-term follow-up studies will add to the evidence base to help further assess the feasibility of this procedure as an alternative to TURP.


Assuntos
Embolização Terapêutica , Próstata/irrigação sanguínea , Hiperplasia Prostática , Prostatismo/terapia , Artérias , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Humanos , Masculino , Hiperplasia Prostática/complicações , Hiperplasia Prostática/terapia , Risco Ajustado , Resultado do Tratamento
5.
World J Urol ; 36(4): 557-563, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29372352

RESUMO

PURPOSE: Three-dimensional (3D) printing was invented in 1983 but has only just begun to influence medicine and surgery. Conversion of digital images into physical models demonstrates promise to revolutionize multiple domains of surgery. In the field of uro-oncology, researchers and clinicians have recognized the potential of this technology and are working towards making it an integral part of urological practice. We review current literature regarding 3D printing and other 3D technology in the field of urology. METHOD: A comprehensive assessment of contemporary literature was performed according to a modified PRISMA analysis for the purposes of this narrative review article. Medical databases that were searched included: Web of Science, EMBASE and Cochrane databases. Articles assessed were limited only to English-language peer-reviewed articles published between 1980 and 2017. The search terms used were "3D", "3-dimensional", "printing", "printing technology", "urology", "surgery". Acceptable articles were reviewed and incorporated for their merit and relevance with preference given for articles with high impact, original research and recent advances. RESULTS: Thirty-five publications were included in final analysis and discussion. CONCLUSIONS: The area of 3D printing in Urology shows promising results, but further research is required and cost reduction must occur before clinicians fully embrace its use. As costs continue to decline and diversity of materials continues to expand, research and clinical utilization will increase. Recent advances have demonstrated the potential of this technology in the realms of education and surgical optimization. The generation of personalized organs using 3D printing scaffolding remains the 'holy grail' of this technology.


Assuntos
Modelos Anatômicos , Impressão Tridimensional , Neoplasias Urológicas/cirurgia , Procedimentos Cirúrgicos Urológicos , Humanos , Oncologia/educação , Oncologia/tendências , Melhoria de Qualidade , Procedimentos Cirúrgicos Urológicos/métodos , Procedimentos Cirúrgicos Urológicos/normas
6.
Surg Endosc ; 32(3): 1600-1606, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28791559

RESUMO

BACKGROUND: Laparoscopic lens fogging (LLF) hampers vision and impedes operative efficiency. Attempts to reduce LLF have led to the development of various anti-fogging fluids and warming devices. Limited literature exists directly comparing these techniques. We constructed a model peritoneum to simulate LLF and to compare the efficacy of various anti-fogging techniques. MATERIALS AND METHODS: Intraperitoneal space was simulated using a suction bag suspended within an 8 L container of water. LLF was induced by varying the temperature and humidity within the model peritoneum. Various anti-fogging techniques were assessed including scope warmers, FREDTM, ResoclearTM, chlorhexidine, betadine and immersion in heated saline. These products were trialled with and without the use of a disposable scope warmer. Vision scores were evaluated by the same investigator for all tests and rated according to a predetermined scale. Fogging was assessed for each product or technique 30 times and a mean vision rating was recorded. RESULTS: All products tested imparted some benefit, but FREDTM performed better than all other techniques. Betadine and ResoclearTM performed no better than the use of a scope warmer alone. Immersion in saline prior to insertion resulted in decreased vision ratings. The robotic scope did not result in LLF within the model. CONCLUSIONS: In standard laparoscopes, the most superior preventative measure was FREDTM utilised on a pre-warmed scope. Despite improvements in LLF with other products FREDTM was better than all other techniques. The robotic laparoscope performed superiorly regarding LLF compared to standard laparoscope.


Assuntos
Laparoscópios/normas , Laparoscopia/instrumentação , Lentes/normas , Procedimentos Cirúrgicos Robóticos/instrumentação , Clorexidina/administração & dosagem , Desinfetantes/administração & dosagem , Temperatura Alta , Humanos , Umidade , Modelos Biológicos , Peritônio , Povidona-Iodo/administração & dosagem , Solução Salina/administração & dosagem , Temperatura
7.
Can J Urol ; 24(2): 8770-8772, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28436367

RESUMO

Bilateral obstructing ureteric calculi is a rare cause of acute renal failure. Although urolithiasis in later pregnancy is not uncommon, the development of bilateral obstruction secondary to ureteric calculi in the first trimester is rare and poses difficulty to diagnosis and management. Symptoms of diseases and physiological changes associated with pregnancy can obscure diagnosis of urolithiasis and obstructive uropathy. Advances in minimally invasive endourology afford intervention with reduced risk to fetal health. We present the second case of acute renal failure caused by bilateral obstructing ureteric calculi in a pregnant patient and discuss current management algorithms for this group.


Assuntos
Injúria Renal Aguda/etiologia , Complicações na Gravidez , Obstrução Ureteral/complicações , Cálculos Urinários/complicações , Adulto , Feminino , Humanos , Gravidez , Complicações na Gravidez/patologia , Obstrução Ureteral/patologia , Cálculos Urinários/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA