Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 137(8): 081009, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25994000

RESUMO

Heart failure is increasing at an alarming rate, making it a worldwide epidemic. As the population ages and life expectancy increases, this trend is not likely to change. Myocardial infarction (MI)-induced adverse left ventricular (LV) remodeling is responsible for nearly 70% of heart failure cases. The adverse remodeling process involves an extension of the border zone (BZ) adjacent to an MI, which is normally perfused but shows myofiber contractile dysfunction. To improve patient-specific modeling of cardiac mechanics, we sought to create a finite element model of the human LV with BZ and MI morphologies integrated directly from delayed-enhancement magnetic resonance (DE-MR) images. Instead of separating the LV into discrete regions (e.g., the MI, BZ, and remote regions) with each having a homogeneous myocardial material property, we assumed a functional relation between the DE-MR image pixel intensity and myocardial stiffness and contractility--we considered a linear variation of material properties as a function of DE-MR image pixel intensity, which is known to improve the accuracy of the model's response. The finite element model was then calibrated using measurements obtained from the same patient--namely, 3D strain measurements-using complementary spatial modulation of magnetization magnetic resonance (CSPAMM-MR) images. This led to an average circumferential strain error of 8.9% across all American Heart Association (AHA) segments. We demonstrate the utility of our method for quantifying smooth regional variations in myocardial contractility using cardiac DE-MR and CSPAMM-MR images acquired from a 78-yr-old woman who experienced an MI approximately 1 yr prior. We found a remote myocardial diastolic stiffness of C(0) = 0.102 kPa, and a remote myocardial contractility of T(max) = 146.9 kPa, which are both in the range of previously published normal human values. Moreover, we found a normalized pixel intensity range of 30% for the BZ, which is consistent with the literature. Based on these regional myocardial material properties, we used our finite element model to compute patient-specific diastolic and systolic LV myofiber stress distributions, which cannot be measured directly. One of the main driving forces for adverse LV remodeling is assumed to be an abnormally high level of ventricular wall stress, and many existing and new treatments for heart failure fundamentally attempt to normalize LV wall stress. Thus, our noninvasive method for estimating smooth regional variations in myocardial contractility should be valuable for optimizing new surgical or medical strategies to limit the chronic evolution from infarction to heart failure.


Assuntos
Imageamento por Ressonância Magnética , Contração Miocárdica , Infarto do Miocárdio/fisiopatologia , Modelagem Computacional Específica para o Paciente , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Feminino , Análise de Elementos Finitos , Humanos , Infarto do Miocárdio/diagnóstico
2.
Heart Rhythm ; 12(1): 144-54, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25173890

RESUMO

BACKGROUND: Standard electroanatomic mapping systems use a single catheter to perform left ventricular substrate mapping. A new mapping system uses a 64-electrode mini-basket catheter to perform rapid automated acquisition of chamber geometry, voltage, and activation. OBJECTIVE: The aim of this study was to compare the accuracy of electroanatomic mapping using the basket catheter with that of mapping using a standard linear catheter in a swine model of chronic myocardial infarction. METHODS: Ten swine underwent left anterior descending coronary artery occlusion to create an anteroseptal myocardial infarction. Animals underwent delayed-enhancement magnetic resonance imaging (MRI) and then detailed left ventricular voltage mapping with both the basket and the linear catheter. Map characteristics and scar area were compared between the basket catheter, linear catheter, and MRI. Induced ventricular tachycardia (VT) was mapped with the basket catheter. RESULTS: More points were acquired with the basket catheter than with the standard catheter (8762 ± 3164 vs 1712 ± 551; P < .001). The fifth percentile of normal bipolar voltage distribution with the basket catheter was 1.54 mV. Using a bipolar voltage cutoff of 1.5 mV, the total infarct areas measured using the basket catheter, linear catheter, and MRI were similar (17.8 cm(2) vs 20.9 cm(2) vs 17.5 cm(2); P = .69); however, the correlation between MRI and catheter scar area measurement was best for the basket catheter (basket vs linear: r = .76 vs r = .71). In 3 animals, sustained poorly tolerated VT was initiated and the circuit mapped successfully with the basket catheter in <5 minutes. CONCLUSION: Rapid substrate and activation mapping using a 64-electrode mini-basket catheter allows detailed voltage and activation mapping in postinfarction cardiomyopathy. This system may be useful for substrate and VT mapping in human postinfarction cardiomyopathy.


Assuntos
Cateterismo Cardíaco/instrumentação , Imageamento Tridimensional , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Animais , Doença Crônica , Modelos Animais de Doenças , Eletrocardiografia , Desenho de Equipamento , Infarto do Miocárdio/complicações , Suínos , Taquicardia Ventricular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA