Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Magn Reson Med ; 90(1): 79-89, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36912481

RESUMO

PURPOSE: To explore the feasibility of measuring ventilation defect percentage (VDP) using 19 F MRI during free-breathing wash-in of fluorinated gas mixture with postacquisition denoising and to compare these results with those obtained through traditional Cartesian breath-hold acquisitions. METHODS: Eight adults with cystic fibrosis and 5 healthy volunteers completed a single MR session on a Siemens 3T Prisma. 1 H Ultrashort-TE MRI sequences were used for registration and masking, and ventilation images with 19 F MRI were obtained while the subjects breathed a normoxic mixture of 79% perfluoropropane and 21% oxygen (O2 ). 19 F MRI was performed during breath holds and while free breathing with one overlapping spiral scan at breath hold for VDP value comparison. The 19 F spiral data were denoised using a low-rank matrix recovery approach. RESULTS: VDP measured using 19 F VIBE and 19 F spiral images were highly correlated (r = 0.84) at 10 wash-in breaths. Second-breath VDPs were also highly correlated (r = 0.88). Denoising greatly increased SNR (pre-denoising spiral SNR, 2.46 ± 0.21; post-denoising spiral SNR, 33.91 ± 6.12; and breath-hold SNR, 17.52 ± 2.08). CONCLUSION: Free-breathing 19 F lung MRI VDP analysis was feasible and highly correlated with breath-hold measurements. Free-breathing methods are expected to increase patient comfort and extend ventilation MRI use to patients who are unable to perform breath holds, including younger subjects and those with more severe lung disease.


Assuntos
Fibrose Cística , Transtornos Respiratórios , Adulto , Humanos , Voluntários Saudáveis , Estudos de Viabilidade , Respiração , Pulmão , Imageamento por Ressonância Magnética/métodos , Fibrose Cística/diagnóstico por imagem , Oxigênio
2.
J Am Chem Soc ; 143(42): 17677-17689, 2021 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-34637304

RESUMO

Modern polymer science suffers from the curse of multidimensionality. The large chemical space imposed by including combinations of monomers into a statistical copolymer overwhelms polymer synthesis and characterization technology and limits the ability to systematically study structure-property relationships. To tackle this challenge in the context of 19F magnetic resonance imaging (MRI) agents, we pursued a computer-guided materials discovery approach that combines synergistic innovations in automated flow synthesis and machine learning (ML) method development. A software-controlled, continuous polymer synthesis platform was developed to enable iterative experimental-computational cycles that resulted in the synthesis of 397 unique copolymer compositions within a six-variable compositional space. The nonintuitive design criteria identified by ML, which were accomplished by exploring <0.9% of the overall compositional space, lead to the identification of >10 copolymer compositions that outperformed state-of-the-art materials.


Assuntos
Meios de Contraste/química , Polímeros/química , Meios de Contraste/síntese química , Flúor/química , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Polímeros/síntese química , Software , Solubilidade
3.
Magn Reson Med ; 85(2): 1028-1038, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32770779

RESUMO

PURPOSE: To quantitatively compare dynamic 19 F and single breath hyperpolarized 129 Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. METHODS: Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic 19 F and single breath 129 Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between 19 F early-breath, 19 F maximum-ventilation, 129 Xe low-resolution, and 129 Xe high-resolution images were compared. Dynamic 19 F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between 129 Xe and 19 F. RESULTS: VDP values from high-resolution 129 Xe images were greater than from low-resolution images (P = .001), although these values were significantly correlated (r = 0.68, P = .03). Early-breath 19 F VDP and max-vent 19 F VDP also showed significant correlation (r = 0.75, P = .012), with early-breath 19 F VDP values being significantly greater (P < .001). No correlation in VDP values were detected between either 19 F method or high-res 129 Xe images. In addition, the location and volume of ventilation defects were often different when comparing 129 Xe and 19 F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. CONCLUSION: In CF subjects, ventilation abnormalities are identified by both 19 F and HP 129 Xe imaging. However, these ventilation abnormalities are not entirely congruent. 19 F and HP 129 Xe imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.


Assuntos
Fibrose Cística , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração , Isótopos de Xenônio
4.
Chemistry ; 26(44): 9982-9990, 2020 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-32468601

RESUMO

Effective diagnosis of disease and its progression can be aided by 19 F magnetic resonance imaging (MRI) techniques. Specifically, the inherent sensitivity of the spin-lattice relaxation time (T1 ) of 19 F nuclei to oxygen partial pressure makes 19 F MRI an attractive non-invasive approach to quantify tissue oxygenation in a spatiotemporal manner. However, there are only few materials with the adequate sensitivity to be used as oxygen-sensitive 19 F MRI agents at clinically relevant field strengths. Motivated by the limitations in current technologies, we report highly fluorinated monomers that provide a platform approach to realize water-soluble, partially fluorinated copolymers as 19 F MRI agents with the required sensitivity to quantify solution oxygenation at clinically relevant magnetic field strengths. The synthesis of a systematic library of partially fluorinated copolymers enabled a comprehensive evaluation of copolymer structure-property relationships relevant to 19 F MRI. The highest-performing material composition demonstrated a signal-to-noise ratio that corresponded to an apparent 19 F density of 220 mm, which surpasses the threshold of 126 mm 19 F required for visualization on a three Tesla clinical MRI. Furthermore, the T1 of these high performing materials demonstrated a linear relationship with solution oxygenation, with oxygen sensitivity reaching 240×10-5  mmHg-1 s-1 . The relationships between material composition and 19 F MRI performance identified herein suggest general structure-property criteria for the further improvement of modular, water-soluble 19 F MRI agents for quantifying oxygenation in environments relevant to medical imaging.


Assuntos
Flúor/análise , Flúor/química , Halogenação , Imageamento por Ressonância Magnética , Oxigênio/análise , Oxigênio/química , Polímeros/química , Pressão Parcial
5.
J Clin Med ; 11(20)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36294480

RESUMO

The availability of highly effective CFTR modulators is revolutionizing the treatment of cystic fibrosis (CF) and drastically improving outcomes. MRI-based imaging modalities are now emerging as highly sensitive endpoints, particularly in the setting of mild lung disease. Adult CF patients were recruited from a single center prior to starting treatment with E/T/I. The following studies were obtained before and after one month on treatment: spirometry, multiple breath nitrogen washout (MBW), 1H UTE MRI (structural images) and 19F MRI (ventilation images). Changes between visits were calculated, as were correlations between FEV1, lung clearance index (LCI), MRI structural scores, and MRI-based ventilation descriptors. Eight subjects had complete datasets for evaluation. Consistent with prior clinical trials, FEV1 and LCI improved after 28 days of E/T/I use. 1H UTE MRI detected improvements in bronchiectasis/airway wall thickening score and mucus plugging score after 28 days of therapy. 19F MRI demonstrated improvements in fractional lung volume with slow gas washout time (FLV↑tau2) and ventilation defect percentage (VDP). Improvements in FLV↑tau2 and VDP correlated with improvement in FEV1 (r = 0.81 and 0.86, respectively, p < 0.05). This observational study establishes the ability of 19F MRI and 1H UTE MRI to detect improvements in lung structure and function after E/T/I treatment. This study supports further development of 19F MRI and 1H UTE MRI as outcome measures for cystic fibrosis research and drug development.

6.
JCI Insight ; 5(2)2020 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-31855577

RESUMO

We hypothesized that dynamic perfluorinated gas MRI would sensitively detect mild cystic fibrosis (CF) lung disease. This cross-sectional study enrolled 20 healthy volunteers and 24 stable subjects with CF, including a subgroup of subjects with normal forced expiratory volume in the first second (FEV1; >80% predicted, n = 9). Dynamic fluorine-19-enhanced MRI (19F MRI) were acquired during sequential breath holds while breathing perfluoropropane (PFP) and during gas wash-out. Outcomes included the fraction of lung without significant ventilation (ventilation defect percent, VDP) and time constants that described PFP wash-in and wash-out kinetics. VDP values (mean ± SD) of healthy controls (3.87% ± 2.7%) were statistically different from moderate CF subjects (19.5% ± 15.5%, P = 0.001) but not from mild CF subjects (10.4% ± 9.9%, P = 0.24). In contrast, the fractional lung volume with slow gas wash-out was elevated both in subjects with mild (9.61% ± 4.87%; P = 0.0066) and moderate CF (16.01% ± 5.01%; P = 0.0002) when compared with healthy controls (3.84% ± 2.16%) and distinguished mild from moderate CF (P = 0.006). 19F MRI detected significant ventilation abnormalities in subjects with CF. The ability of gas wash-out kinetics to distinguish between healthy and mild CF lung disease subjects makes 19F MRI a potentially valuable method for the characterization of early lung disease in CF. This study has been registered at ClinicalTrials.gov (NCT03489590).


Assuntos
Fibrose Cística/diagnóstico por imagem , Fluorocarbonos/química , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Estudos Transversais , Proteínas de Ligação a DNA , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Fatores de Transcrição , Ventilação , Adulto Jovem
7.
IEEE Int Conf Rehabil Robot ; 2017: 308-313, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28813837

RESUMO

It is well known that the activation of plantar flexors have a strong influence on the walking speed. If the gait speed can be predicted using this relationship, a post-stroke hemiparetic patient could control a gait rehabilitation robot according to his or her gait intention, and the robotic gait rehabilitation effect could be further improved. To find out this relationship, 9 nondisabled subjects and 4 chronic post-stroke hemiparetic subjects performed overground level walking at a comfortable pace, a slow pace, a fast pace, and an increasing pace with electromyogram sensors attached on plantar flexors. Soleus among plantar flexors showed the most stable relationship with walking speed. The relationship between maximum activation level of soleus electromyogram during stance phase before toe-off and walking speed during swing phase after the same toe-off was modeled by a polynomial regression model. The model outputs were then compared to the measured walking speeds using coefficients of determination (R2). The average R2 values are 0.594 and 0.692 for 1st· and 2nd order models respectively in the nondisabled subjects. The average R2 values are 0.598 and 0.623 for the unaffected side and 0.388 and 0.394 for the affected side in the chronic subjects. The results show the feasibility of applying the soleus-walking speed relationship to control the robot gait speed at will. A walking speed estimation method is proposed using only a walking step in real time.


Assuntos
Eletromiografia/métodos , Músculo Esquelético/fisiologia , Paresia/fisiopatologia , Acidente Vascular Cerebral/fisiopatologia , Velocidade de Caminhada/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Processamento de Sinais Assistido por Computador , Reabilitação do Acidente Vascular Cerebral , Adulto Jovem
8.
Arch Craniofac Surg ; 18(4): 269-272, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29349053

RESUMO

Myxoid solitary fibrous tumor (SFT) is very rare soft tissue neoplasm. It is microscopically composed of spindle cells which is individually separated by delicate band of collagen fibers. And this tumor cells are immunohisto-chemistrically highlighted by CD34. Myxoid SFT has indolent clinical course and a good prognosis, so it is important to make a diagnosis because of its morphological similarities to myxoid spindle cell neoplasms that have different prognoses and treatment. We report the case of a 20-year-old female with a myxoid SFT found in the left temporo-parietal scalp. This case report appears to be the first reported scalp occurrence of this rare tumor.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA