RESUMO
BACKGROUND: The present study contrasts the accuracy of different reconstructed models with distinctive segmentation methods performed by various experts. Seven research groups reconstructed nine 3D models of one human femur based on an acquired CT image using their own computational methods. As a reference model for accuracy assessment, a 3D surface scan of the human femur was created using an optical measuring system. Prior to comparison, the femur was divided into four areas; "neck and greater trochanter", "proximal metaphysis", "diaphysis", and "distal metaphysis". The deviation analysis was carried out in GEOMAGIC studio v.2013 software. RESULTS: The results revealed that the highest deviation errors occurred in "neck and greater trochanter" area and "proximal metaphysis" area with RMSE of 0.84 and 0.83 mm respectively. CONCLUSION: In conclusion, this study shows that the average deviation of reconstructed models prepared by experts with various methods, skills and software from the surface 3D scan is lower than 0.79 mm, which is not a significant discrepancy.
Assuntos
Fêmur/diagnóstico por imagem , Imageamento Tridimensional , Laboratórios , Fenômenos Ópticos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Humanos , Pessoa de Meia-Idade , Padrões de ReferênciaRESUMO
Finite element analysis is a common tool that has been used for the past few decades to predict the mechanical behavior of bone. However, to our knowledge, there are no round-robin finite element analyses of long human bones with more than two participating biomechanics laboratories published yet, where the results of the experimental tests were not known in advance. We prepared a fresh-frozen human femur for a compression test in a universal testing machine measuring the strains at 10 bone locations as well as the deformation of the bone in terms of the displacement of the loading point at a load of 2 kN. The computed tomography data of the bone with a calibration phantom as well as the orientation of the bone in the testing machine with the according boundary conditions were delivered to seven participating laboratories. These were asked to perform a finite element analysis simulating the experimental setup and deliver their results to the coordinator without knowing the experimental results. Resultantly, four laboratories had deviations from the experimentally measured strains of less than 40%, and three laboratories had deviations of their numerically determined values compared to the experimental data of more than 120%. These deviations are thought to be based on different material laws and material data, as well as different material mapping methods. Investigations will be conducted to clarify and assess the reasons for the large deviations in the numerical data. It was shown that the precision of finite element models of the human femur is not yet as developed as desired by the biomechanics community.