RESUMO
We report the measurement of the beam-vector and tensor asymmetries A_{ed}^{V} and A_{d}^{T} in quasielastic (e[over â],e^{'}p) electrodisintegration of the deuteron at the MIT-Bates Linear Accelerator Center up to missing momentum of 500 MeV/c. Data were collected simultaneously over a momentum transfer range 0.1
RESUMO
PURPOSE: A first of its kind experimental verification of dose-averaged linear energy transfer (LETd) optimized treatment plans for proton therapy has been carried out using a silicon-on-insulator microdosimeter at the Massachusetts General Hospital (MGH), Boston, USA. METHODS AND MATERIALS: Three clinical treatment plans of a typical ependymoma structure set were designed using the standard clinical approach, the proposed protocol approach, and a one-field approach. The plans were then reoptimized to reduce the LETd-weighted dose in the brain stem. All six plans were delivered in a solid water phantom and the experimental yDâ¾ measured. RESULTS: After LETd optimization, a reduction in yDâ¾ was found within the brain stem by an average of 12%, 19%, and 4% for the clinical, protocol, and one-field plans, respectively, while maintaining adequate coverage of the tumor structure. The experimental LETd-weighted doses were in agreement with the treatment planning system calculations and Monte Carlo simulations and reinforced the improvement of the optimization. CONCLUSIONS: This work demonstrates the first experimental verification of the clinical implementation of LETd optimization for patient treatment with proton therapy.
Assuntos
Neoplasias Encefálicas , Ependimoma , Transferência Linear de Energia , Método de Monte Carlo , Imagens de Fantasmas , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Terapia com Prótons/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagem , Ependimoma/radioterapia , Ependimoma/diagnóstico por imagem , Radiometria/métodos , Radiometria/instrumentação , Tronco Encefálico/diagnóstico por imagem , Silício , Órgãos em Risco/efeitos da radiaçãoRESUMO
We present new measurements of electron scattering from high-momentum nucleons in nuclei. These data allow an improved determination of the strength of two-nucleon correlations for several nuclei, including light nuclei where clustering effects can, for the first time, be examined. The data also include the kinematic region where three-nucleon correlations are expected to dominate.
RESUMO
The use of field-specific apertures, routine in scattered or uniform-scanned proton fields, are still a necessity in pencil-beam scanned (PBS) fields to sharpen the penumbral edge at low energies and in high fraction dose application beyond that achievable with small spot size. We describe a model implemented in our clinical pencil-beam algorithm that models the insertion of a shaped aperture, including shapes adapted per energy layer such as may be achieved with a multi-leaf collimator. The model decomposes the spot transport into discrete steps. The first step transport a uniform intensity field of high-resolution sub-pencil-beams at the layer energy through the medium. This transport only considers primary scattering in both the patient and an optional range-shifter. The second step models the aperture areas and edge penumbral transition as a modulation of the uniform intensity. The third step convolves individual steps over the uniform-transported field including the aperture-modified intensities. We also introduce an efficient model based on a Clarkson sector integration for nuclear scattered halo protons. This avoids the explicit modeling of long range halo protons to the detriment of computational efficiency in calculation and optimization. We demonstrate that the aperture effect is primarily due to in-patient and shifter scattering with a small contribution from the apparent beam source position. The model provides insight into the primary physics contributions to the penumbra and the nuclear halo. The model allowed us to fully deploy our PBS capacity at our two-gantry center without which PBS treatments would have been inferior compared to scattered fields with apertures. Finally, Monte Carlo calculations have (nearly) replaced phenomenological pencil-beam models for collimated fields. Phenomenological models do, however, allow exposition of underlying clinical phenomena and closer connection to representative clinical observables.
Assuntos
Terapia com Prótons , Prótons , Algoritmos , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
We report a precision measurement of the deuteron tensor analyzing powers T(20) and T(21) at the MIT-Bates Linear Accelerator Center. Data were collected simultaneously over a momentum transfer range Q=2.15-4.50 fm(-1) with the Bates Large Acceptance Spectrometer Toroid using a highly polarized deuterium internal gas target. The data are in excellent agreement with calculations in a framework of effective field theory. The deuteron charge monopole and quadrupole form factors G(C) and G(Q) were separated with improved precision, and the location of the first node of G(C) was confirmed at Q=4.19±0.05 fm(-1). The new data provide a strong constraint on theoretical models in a momentum transfer range covering the minimum of T(20) and the first node of G(C).
RESUMO
We present new data on electron scattering from a range of nuclei taken in Hall C at Jefferson Lab. For heavy nuclei, we observe a rapid falloff in the cross section for x>1, which is sensitive to short-range contributions to the nuclear wave function, and in deep inelastic scattering corresponds to probing extremely high momentum quarks. This result agrees with higher energy muon scattering measurements, but is in sharp contrast to neutrino scattering measurements which suggested a dramatic enhancement in the distribution of the "superfast" quarks probed at x>1. The falloff at x>1 is noticeably stronger in 2H and 3He, but nearly identical for all heavier nuclei.
RESUMO
PURPOSE: The aim of this manuscript is to describe the direct measurement of absolute absorbed dose to water in a scanned proton radiotherapy beam using a water calorimeter primary standard. METHODS: The McGill water calorimeter, which has been validated in photon and electron beams as well as in HDR 192Ir brachytherapy, was used to measure the absorbed dose to water in double scattering and scanning proton irradiations. The measurements were made at the Massachusetts General Hospital proton radiotherapy facility. The correction factors in water calorimetry were numerically calculated and various parameters affecting their magnitude and uncertainty were studied. The absorbed dose to water was compared to that obtained using an Exradin T1 Chamber based on the IAEA TRS-398 protocol. RESULTS: The overall 1-sigma uncertainty on absorbed dose to water amounts to 0.4% and 0.6% in scattered and scanned proton water calorimetry, respectively. This compares to an overall uncertainty of 1.9% for currently accepted IAEA TRS-398 reference absorbed dose measurement protocol. The absorbed dose from water calorimetry agrees with the results from TRS-398 well to within 1-sigma uncertainty. CONCLUSIONS: This work demonstrates that a primary absorbed dose standard based on water calorimetry is feasible in scattered and scanned proton beams.
Assuntos
Calorimetria , Terapia com Prótons , Radiometria/métodos , Água/química , Radiometria/instrumentação , Dosagem Radioterapêutica , Condutividade Térmica , IncertezaRESUMO
New Jefferson Lab data are presented on the nuclear dependence of the inclusive cross section from (2)H, (3)He, (4)He, (9)Be and (12)C for 0.3 < x < 0.9, Q(2) approximately 3-6 GeV(2). These data represent the first measurement of the EMC effect for (3)He at large x and a significant improvement for (4)He. The data do not support previous A-dependent or density-dependent fits to the EMC effect and suggest that the nuclear dependence of the quark distributions may depend on the local nuclear environment.
RESUMO
BACKGROUND: In scanned proton beam therapy systematic deviations in spot size at iso-center can occur as a result of changes in the beam-line optics. There is currently no general guideline of the spot size accuracy required clinically. In this work we quantify treatment plan robustness to systematic spot size variations as a function of spot size and spot spacing, and we suggest guidelines for tolerance levels for spot size variations. METHODS: Through perturbation of spot size in treatment plans for 7 patients and a phantom, we evaluated the dose impact of systematic spot size variations of 5% up to 50%. We investigated the dependence on nominal spot size by studying scenarios with small, medium and large spot sizes for various inter-spot spacings. To come to tolerance levels, we used the Γ passing rate and dose-volume-histograms. RESULTS: Limits on spot size accuracy were extracted for 8 sites, 3 different spot sizes and 3 different inter-spot spacings. While the allowable spot size variation strongly depends on the spot size, the inter-spot spacing turned out to be only of limited influence. CONCLUSIONS: Plan robustness to spot size variations strongly depend on spot size, with small spot plans being much more robust than larger spots plans. Inter-spot spacing did not influence plan robustness. Combining our results with existing literature, we propose limits of ±25%, ±20% and ±10% of the spot width σ, for spots with σ of 2.5, 5.0 and 10â¯mm in proton therapy spot scanning facilities, respectively.
Assuntos
Terapia com Prótons/métodos , Doses de Radiação , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
PURPOSE: Patient specific apertures are commonly employed in passive double scattering (DS) proton therapy (PT). This study was aimed at identifying the potential benefits of using such an aperture in pencil beam scanning (PBS). METHODS: An accurate Geant4 Monte Carlo model of the PBS PT treatment head at Massachusetts General Hospital (MGH) was developed based on an existing model of the passive double-scattering (DS) system. The Monte Carlo code specifies the treatment head at MGH with sub-millimeter accuracy and was configured based on the results of experimental measurements performed at MGH. This model was then used to compare out-of-field doses in simulated DS treatments and PBS treatments. The PBS treatments were simulated both with and without the patient-specific aperture used in the DS treatment. RESULTS: For the conditions explored, a typical prostate field, the lateral penumbra in PBS is wider than in DS, leading to higher absorbed doses and equivalent doses adjacent to the primary field edge. For lateral distances greater than 10cm from the field edge, the doses in PBS appear to be lower than those observed for DS. Including an aperture at nozzle exit reduces the penumbral width by preventing wide-angle scatter from reaching the patient. This can reduce the dose in PBS for lateral distances of less than 10cm from the field edge by over an order of magnitude and allow better dose conformity. CONCLUSIONS: Placing a patient-specific aperture at nozzle exit during PBS treatments can potentially reduce doses lateral to the primary radiation field by over an order of magnitude. This has the potential to further improve the normal tissue sparing capabilities of PBS. The magnitude of this effect depends on the beam spot size of the scanning system and is thus facility dependent.
RESUMO
We report new measurements of the neutron charge form factor at low momentum transfer using quasielastic electrodisintegration of the deuteron. Longitudinally polarized electrons at an energy of 850 MeV were scattered from an isotopically pure, highly polarized deuterium gas target. The scattered electrons and coincident neutrons were measured by the Bates Large Acceptance Spectrometer Toroid (BLAST) detector. The neutron form factor ratio GEn/GMn was extracted from the beam-target vector asymmetry AedV at four-momentum transfers Q2=0.14, 0.20, 0.29, and 0.42 (GeV/c)2.
RESUMO
We have measured the nuclear transparency of the A(e,e'pi+) process in 2H, 12C, 27Al, 63Cu, and 197Au targets. These measurements were performed at the Jefferson Laboratory over a four momentum transfer squared range Q2=1.1 to 4.7 (GeV/c)2. The nuclear transparency was extracted as the super-ratio of (sigmaA/sigmaH) from data to a model of pion-electroproduction from nuclei without pi-N final-state interactions. The Q2 and atomic number dependence of the nuclear transparency both show deviations from traditional nuclear physics expectations and are consistent with calculations that include the quantum chromodynamical phenomenon of color transparency.
RESUMO
We report the first precision measurement of the proton electric to magnetic form factor ratio from spin-dependent elastic scattering of longitudinally polarized electrons from a polarized hydrogen internal gas target. The measurement was performed at the MIT-Bates South Hall Ring over a range of four-momentum transfer squared Q2 from 0.15 to 0.65 (GeV/c)(2). Significantly improved results on the proton electric and magnetic form factors are obtained in combination with existing cross-section data on elastic electron-proton scattering in the same Q2 region.
RESUMO
We have measured the differential cross section for the gamman-->pi(-)p and gammap-->pi(+)n reactions at theta(c.m.)=90 degrees in the photon energy range from 1.1 to 5.5 GeV at Jefferson Lab (JLab). The data at E(gamma) greater, similar 3.3 GeV exhibit a global scaling behavior for both pi(-) and pi(+) photoproduction, consistent with the constituent counting rule and the existing pi(+) photoproduction data. Possible oscillations around the scaling value are suggested by these new data. The data show enhancement in the scaled cross section at a center-of-mass energy near 2.2 GeV. The cross section ratio of exclusive pi(-) to pi(+) photoproduction at high energy is consistent with the prediction based on one-hard-gluon-exchange diagrams.
RESUMO
We report on a new measurement of the parity-violating asymmetry in quasielastic electron scattering from the deuteron at backward angles at Q2=0.038 (GeV/c)2. This quantity provides a determination of the neutral weak axial vector form factor of the nucleon, which can potentially receive large electroweak corrections. The measured asymmetry A=-3.51+/-0.57 (stat)+/-0.58 (syst) ppm is consistent with theoretical predictions. We also report on updated results of the previous experiment at Q2=0.091 (GeV/c)2, which are also consistent with theoretical predictions.