Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 101(7): 1203-1213, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37070459

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI. OBJECTIVES: To identify MS length and ΔMSID as predictors of CA/PPI following TAVI. METHODS: Study-level meta-analysis of studies published by September 30, 2022. RESULTS: Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively. CONCLUSION: Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
2.
J Endovasc Ther ; 30(6): 885-891, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35766367

RESUMO

BACKGROUND: Vascular complications are a cause of increased morbidity and mortality when performing percutaneous procedures requiring large-bore arterial access. MANTA vascular closure device (VCD) is currently the only large-bore VCD using an intraluminal foot plate and an extraluminal collagen plug. The traditional depth locator approach might be compromised in; emergent cases without the required measurements, cases of hematoma formation, or other patient, procedure, or operator-specific variables. Furthermore, this technique can be used for postclosure in cases without the required measurement of depth. We describe vascular outcomes using fluoroscopy (fluoroscopic DOT technique) rather than traditional depth locator approach for vascular closure with the MANTA VCD. METHODS: Fifty patients who underwent transcatheter aortic valve implantation (TAVI) were retrospectively analyzed using fluoroscopic DOT technique with 18F MANTA VCD between May and August 2021. All patients >18 years of age who qualified for transfemoral TAVI were included. Access was obtained with ultrasound guidance with vessel diameter of at least > 6 mm and free from anterior vessel wall calcification. Patient related factors and primary outcomes of access site bleeding and acute flow-limited limb ischemia requiring intervention were prospectively analyzed. Furthermore, 1 patient who failed hemostasis with suture-mediated VCD had successful hemostasis with fluoroscopic DOT technique as dry postclosure after balloon aortic valvuloplasty. RESULTS: In total, 50 patients were analyzed with a mean age of 81 years and majority were male (56%). Majority had comorbidities of hypertension (88%) and hyperlipidemia (94%), 24% had peripheral arterial disease, 38% coronary artery disease, and 58% were former smokers. Importantly, 40% were obese with an average body mass index (BMI) of 29 kg/m2. There were no bleeding or ischemic limb complications post MANTA VCD deployment using the fluoroscopic DOT technique. Furthermore, none of the patients required peripheral intervention from index procedure to 1 month post verified during their 1-month post TAVR follow-up. CONCLUSION: Fluoroscopic DOT technique using the MANTA VCD is highly reproducible and allows hemostasis in a predictable manner for procedures requiring large-bore arterial access in the absence of MANTA depth measurement.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Dispositivos de Oclusão Vascular , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Dispositivos de Oclusão Vascular/efeitos adversos , Técnicas Hemostáticas/efeitos adversos , Estudos Retrospectivos , Cateterismo Periférico/efeitos adversos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38719630

RESUMO

BACKGROUND/PURPOSE: To evaluate the impact of coronary artery disease (CAD), percutaneous coronary intervention (PCI), and coronary lesion complexity on outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS/MATERIALS: This retrospective study included 1042 patients divided into two groups by the presence or absence of CAD (SYNTAX score 0, no history of revascularization). Propensity score matching was used to compare the two groups. The effect of PCI, SYNTAX score, and residual SYNTAX score was also analyzed. RESULTS: The median age of the cohort was 82 years, and 641 patients had CAD. After propensity score matching, 346 pairs were analyzed. During 5 years of follow-up (median: 25, range 0-72 months), the rate of coronary intervention was significantly higher in CAD patients (p = 0.018). However, all-cause mortality, composite of all-cause mortality, stroke, and coronary intervention, and overt bleeding defined by VARC-3 were comparable. After stratification, in patients with creatinine ≥1.5 mg/dl, CAD was associated with a worse composite outcome (p = 0.016). Neither PCI nor SYNTAX score was associated with all-cause mortality in CAD patients. Similarly, residual SYNTAX score showed no association with mortality in patients undergoing PCI (all p values >0.7). PCI did not reach a significant difference in overt bleeding in CAD patients (adjusted p = 0.06). CONCLUSIONS: Despite a higher incidence of coronary interventions, major clinical outcomes were similar between patients with and without CAD after TAVR. In patients with chronic kidney disease, CAD may be associated with an adverse composite outcome. Neither PCI nor SYNTAX/residual SYNTAX score influenced all-cause mortality.

4.
Coron Artery Dis ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38739467

RESUMO

OBJECTIVE: To investigate the impact of prior coronary artery bypass grafting (CABG) and coronary lesion complexity on transcatheter aortic valve replacement (TAVR) outcomes for aortic stenosis. METHODS: Clinical outcomes of TAVR were retrospectively compared between patients with and without prior CABG, and between patients with prior CABG and without coronary artery disease (CAD). The impact of the CABG SYNTAX score was also evaluated in patients with prior CABG. RESULTS: The study included 1042 patients with a median age and follow-up of 82 years and 25 (range: 0-72) months, respectively. Of these, 175 patients had a history of CABG, while 401 were free of CAD. Patients with prior CABG were more likely to be male and had higher rates of diabetes, peripheral artery disease and atrial fibrillation compared with patients without prior CABG. After 2 : 1 propensity score matching, all-cause mortality (P = 0.17) and the composite of all-cause mortality, stroke and coronary intervention (P = 0.16) were similar between patients with (n = 166) and without (n = 304) prior CABG. A 1 : 1 propensity score-matched analysis, however, showed lower rates of all-cause mortality (P = 0.04) and the composite outcome (P = 0.04) in patients with prior CABG (n = 134) compared with patients without CAD (n = 134). The median CABG SYNTAX score was 16 (interquartile range: 9.0-23), which was not associated with better/worse clinical outcomes in patients with prior CABG. CONCLUSION: Prior CABG may positively affect mid-term TAVR outcomes for aortic stenosis compared with no CAD when adjusted for other comorbidities. The CABG SYNTAX score did not influence the prognosis after TAVR.

5.
J Invasive Cardiol ; 36(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38422528

RESUMO

OBJECTIVES: To assess the impact of concomitant mitral stenosis (MS) on early and late outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS: This study involved 952 patients undergoing TAVR for severe tricuspid aortic stenosis. The patients were classified into 3 groups: without MS, with progressive MS, and severe MS (mitral valve area ≤ 1.5 cm2). Clinical outcomes between these groups were compared. RESULTS: The median age of the overall cohort was 82 years, and patients in the progressive (n = 49) and severe (n = 24) MS groups were more likely to be female than those in the no-MS group (n = 879). Periprocedural mortality rate was lowest in the no-MS group (1.8%) compared with the progressive (4.1%) and severe (4.2%) MS groups, which were not significantly different (P = .20). During 5 years of follow-up (median: 27, range: 0-72 months), there was no significant difference in all-cause mortality (log-rank P = .99), a composite of all-cause mortality or rehospitalization for heart failure (log-rank P = .84), or cardiovascular death (log-rank P = .57) between groups. Although crude analysis showed a significant difference in rehospitalization for heart failure in the severe MS group compared with the no-MS group (P = .049), the difference was not significant in the multivariate analysis (adjusted hazard ratio: 1.36 [95% CI, 0.66-2.80], P = .41). CONCLUSIONS: TAVR can be safely performed in patients with severe tricuspid aortic stenosis and concomitant MS, with early and mid-term outcomes comparable to those in patients without MS.


Assuntos
Estenose da Valva Aórtica , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/complicações , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Seguimentos , Índice de Gravidade de Doença , Resultado do Tratamento , Idoso , Taxa de Sobrevida/tendências , Fatores de Tempo , Fatores de Risco , Complicações Pós-Operatórias/epidemiologia
6.
Am J Cardiol ; 221: 9-18, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636627

RESUMO

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Pontuação de Propensão , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Idoso , Ecocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA