Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(7): e2218909120, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36757892

RESUMO

An effective evasion strategy allows prey to survive encounters with predators. Prey are generally thought to escape in a direction that is either random or serves to maximize the minimum distance from the predator. Here, we introduce a comprehensive approach to determine the most likely evasion strategy among multiple hypotheses and the role of biomechanical constraints on the escape response of prey fish. Through a consideration of six strategies with sensorimotor noise and previous kinematic measurements, our analysis shows that zebrafish larvae generally escape in a direction orthogonal to the predator's heading. By sensing only the predator's heading, this orthogonal strategy maximizes the distance from fast-moving predators, and, when operating within the biomechanical constraints of the escape response, it provides the best predictions of prey behavior among all alternatives. This work demonstrates a framework for resolving the strategic basis of evasion in predator-prey interactions, which could be applied to a broad diversity of animals.


Assuntos
Comportamento Predatório , Peixe-Zebra , Animais , Peixe-Zebra/fisiologia , Larva/fisiologia , Comportamento Predatório/fisiologia , Reação de Fuga , Fenômenos Biomecânicos
2.
Med Phys ; 50(3): 1349-1366, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36515381

RESUMO

BACKGROUND: Motion during data acquisition leads to artifacts in computed tomography (CT) reconstructions. In cases such as cardiac imaging, not only is motion unavoidable, but evaluating the motion of the object is of clinical interest. Reducing motion artifacts has typically been achieved by developing systems with faster gantry rotation or via algorithms which measure and/or estimate the displacement. However, these approaches have had limited success due to both physical constraints as well as the challenge of estimating non-rigid, temporally varying, and patient-specific motion fields. PURPOSE: To develop a novel reconstruction method which generates time-resolved, artifact-free images without estimation or explicit modeling of the motion. METHODS: We describe an analysis-by-synthesis approach which progressively regresses a solution consistent with the acquired sinogram. In our method, we focus on the movement of object boundaries. Not only are the boundaries the source of image artifacts, but object boundaries can simultaneously be used to represent both the object as well as its motion over time without the need for an explicit motion model. We represent the object boundaries via a signed distance function (SDF) which can be efficiently modeled using neural networks. As a result, optimization can be performed under spatial and temporal smoothness constraints without the need for explicit motion estimation. RESULTS: We illustrate the utility of DiFiR-CT in three imaging scenarios with increasing motion complexity: translation of a small circle, heart-like change in an ellipse's diameter, and a complex topological deformation. Compared to filtered backprojection, DiFiR-CT provides high quality image reconstruction for all three motions without hyperparameter tuning or change to the architecture. We also evaluate DiFiR-CT's robustness to noise in the acquired sinogram and found its reconstruction to be accurate across a wide range of noise levels. Lastly, we demonstrate how the approach could be used for multi-intensity scenes and illustrate the importance of the initial segmentation providing a realistic initialization. Code and supplemental movies are available at https://kunalmgupta.github.io/projects/DiFiR-CT.html. CONCLUSIONS: Projection data can be used to accurately estimate a temporally-evolving scene without the need for explicit motion estimation using a neural implicit representation and analysis-by-synthesis approach.


Assuntos
Movimento , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Movimento (Física) , Algoritmos , Coração/diagnóstico por imagem , Artefatos , Rotação , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas
3.
bioRxiv ; 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36711867

RESUMO

An effective evasion strategy allows prey to survive encounters with predators. Prey are generally thought to escape in a direction that is either random or serves to maximize the minimum distance from the predator. Here we introduce a comprehensive approach to determine the most likely evasion strategy among multiple hypotheses and the role of biomechanical constraints on the escape response of prey fish. Through a consideration of six strategies with sensorimotor noise and previous kinematic measurements, our analysis shows that zebrafish larvae generally escape in a direction orthogonal to the predator's heading. By sensing only the predator's heading, this orthogonal strategy maximizes the distance from fast-moving predators, and, when operating within the biomechanical constraints of the escape response, it provides the best predictions of prey behavior among all alternatives. This work demonstrates a framework for resolving the strategic basis of evastion in predator-prey interactions, which could be applied to a broad diversity of animals.

4.
ArXiv ; 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36713242

RESUMO

An effective evasion strategy allows prey to survive encounters with predators. Prey are generally thought to escape in a direction that is either random or serves to maximize the minimum distance from the predator. Here we introduce a comprehensive approach to determine the most likely evasion strategy among multiple hypotheses and the role of biomechanical constraints on the escape response of prey fish. Through a consideration of six strategies with sensorimotor noise and previous kinematic measurements, our analysis shows that zebrafish larvae generally escape in a direction orthogonal to the predator's heading. By sensing only the predator's heading, this orthogonal strategy maximizes the distance from fast-moving predators, and, when operating within the biomechanical constraints of the escape response, it provides the best predictions of prey behavior among all alternatives. This work demonstrates a framework for resolving the strategic basis of evastion in predator-prey interactions, which could be applied to a broad diversity of animals.

5.
Med Phys ; 49(9): 5841-5854, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35751864

RESUMO

BACKGROUND: Estimates of regional left ventricular (LV) strains provide additional information to global function parameters such as ejection fraction (EF) and global longitudinal strain (GLS) and are more sensitive in detecting abnormal regional cardiac function. The accurate and reproducible assessment of regional cardiac function has implications in the management of various cardiac diseases such as heart failure, myocardial ischemia, and dyssynchrony. PURPOSE: To develop a method that yields highly reproducible, high-resolution estimates of regional endocardial strains from 4DCT images. METHODS: A method for estimating regional LV endocardial circumferential ( ε c c ) $( {{\epsilon }_{cc}} )$ and longitudinal ( ε l l ${\epsilon }_{ll}$ ) strains from 4DCT was developed. Point clouds representing the LV endocardial surface were extracted for each time frame of the cardiac cycle from 4DCT images. 3D deformation fields across the cardiac cycle were obtained by registering the end diastolic point cloud to each subsequent point cloud in time across the cardiac cycle using a 3D point-set registration technique. From these deformation fields, ε c c and ε l l ${\epsilon }_{cc}\ {\rm{and\ }}{\epsilon }_{ll}$ were estimated over the entire LV endocardial surface by fitting an affine transformation with maximum likelihood estimation. The 4DCT-derived strains were compared with strains estimated in the same subjects by cardiac magnetic resonance (CMR); twenty-four subjects had CMR scans followed by 4DCT scans acquired within a few hours. Regional LV circumferential and longitudinal strains were estimated from the CMR images using a commercially available feature tracking software (cvi42). Global circumferential strain (GCS) and global longitudinal strain (GLS) were calculated as the mean of the regional strains across the entire LV for both modalities. Pearson correlation coefficients and Bland-Altman analyses were used for comparisons. Intraclass correlation coefficients (ICC) were used to assess the inter- and intraobserver reproducibility of the 4DCT-derived strains. RESULTS: The 4DCT-derived regional strains correlated well with the CMR-derived regional strains ( ε c c ${\epsilon }_{cc}$ : r = 0.76, p < 0.001; ε l l ${\epsilon }_{ll}$ : r = 0.64, p < 0.001). A very strong correlation was found between 4DCT-derived GCS and 4DCT-derived EF (r = -0.96; p < 0.001). The 4DCT-derived strains were also highly reproducible, with very low inter- and intraobserver variability (intraclass correlation coefficients in the range of [0.92, 0.99]). CONCLUSIONS: We have developed a novel method to estimate high-resolution regional LV endocardial circumferential and longitudinal strains from 4DCT images. Except for the definition of the mitral valve and LV outflow tract planes, the method is completely user independent, thus yielding highly reproducible estimates of endocardial strain. The 4DCT-derived strains correlated well with those estimated using a commercial CMR feature tracking software. The promising results reported in this study highlight the potential utility of 4DCT in the precise assessment of regional cardiac function for the management of cardiac disease.


Assuntos
Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes
6.
Med Phys ; 48(9): 4966-4977, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34287949

RESUMO

PURPOSE: Cardiac computed tomography has a clear clinical role in the evaluation of coronary artery disease and assessment of coronary artery calcium (CAC) but the use of ionizing radiation limits the clinical use. Beam-shaping "bow-tie" filters determine the radiation dose and the effective scan field-of-view diameter (SFOV) by delivering higher X-ray fluence to a region centered at the isocenter. A method for positioning the heart near the isocenter could enable reduced SFOV imaging and reduce dose in cardiac scans. However, a predictive approach to center the heart, the extent to which heart centering can reduce the SFOV, and the associated dose reductions have not been assessed. The purpose of this study is to build a heart-centered patient positioning model, to test whether it reduces the SFOV required for accurate CAC scoring, and to quantify the associated reduction in radiation dose. METHODS: The location of 38,184 calcium lesions (3151 studies) in the Multi-Ethnic Study of Atherosclerosis was utilized to build a predictive heart-centered positioning model and compare the impact of SFOV on CAC scoring accuracy in heart-centered and conventional body-centered scanning. Then, the positioning model was applied retrospectively to an independent, contemporary cohort of 118 individuals (81 with CAC > 0) at our institution to validate the model's ability to maintain CAC accuracy while reducing the SFOV. In these patients, the reduction in dose associated with a reduced SFOV beam-shaping filter was quantified. RESULTS: Heart centering reduced the SFOV diameter 25.7% relative to body centering while maintaining high CAC scoring accuracy (0.82% risk reclassification rate). In our validation cohort, imaging at this reduced SFOV with heart-centered positioning and tailored beam-shaping filtration led to a 26.9% median dose reduction (25-75th percentile: 21.6%-29.8%) without any calcium risk reclassification. CONCLUSIONS: Heart-centered patient positioning enables a significant radiation dose reduction while maintaining CAC accuracy.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Calcificação Vascular , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Doses de Radiação , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem
7.
Radiol Artif Intell ; 3(6): e210036, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34870221

RESUMO

PURPOSE: To assess whether octree representation and octree-based convolutional neural networks (CNNs) improve segmentation accuracy of three-dimensional images. MATERIALS AND METHODS: Cardiac CT angiographic examinations from 100 patients (mean age, 67 years ± 17 [standard deviation]; 60 men) performed between June 2012 and June 2018 with semantic segmentations of the left ventricular (LV) and left atrial (LA) blood pools at the end-diastolic and end-systolic cardiac phases were retrospectively evaluated. Image quality (root mean square error [RMSE]) and segmentation fidelity (global Dice and border Dice coefficients) metrics of the octree representation were compared with spatial downsampling for a range of memory footprints. Fivefold cross-validation was used to train an octree-based CNN and CNNs with spatial downsampling at four levels of image compression or spatial downsampling. The semantic segmentation performance of octree-based CNN (OctNet) was compared with the performance of U-Nets with spatial downsampling. RESULTS: Octrees provided high image and segmentation fidelity (median RMSE, 1.34 HU; LV Dice coefficient, 0.970; LV border Dice coefficient, 0.843) with a reduced memory footprint (87.5% reduction). Spatial downsampling to the same memory footprint had lower data fidelity (median RMSE, 12.96 HU; LV Dice coefficient, 0.852; LV border Dice coefficient, 0.310). OctNet segmentation improved the border segmentation Dice coefficient (LV, 0.612; LA, 0.636) compared with the highest performance among U-Nets with spatial downsampling (Dice coefficients: LV, 0.579; LA, 0.592). CONCLUSION: Octree-based representations can reduce the memory footprint and improve segmentation border accuracy.Keywords CT, Cardiac, Segmentation, Supervised Learning, Convolutional Neural Network (CNN), Deep Learning Algorithms, Machine Learning Algorithms© RSNA, 2021.

8.
Bioinspir Biomim ; 14(1): 016009, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30479313

RESUMO

We consider the inverse problem of classifying flow patterns from local sensory measurements. This problem is inspired by the ability of various aquatic organisms to respond to ambient flow signals, and is relevant for translating these abilities to underwater robotic vehicles. In Colvert, Alsalman and Kanso, B&B (2018), we trained neural networks to classify vortical flows by relying on a single flow sensor that measures a 'time history' of the local vorticity. Here, we systematically investigate the effects of distinct types of sensors on the accuracy of flow classification. We consider four types of sensors-vorticity, flow velocities parallel and transverse to the direction of flow propagation, and flow speed-and show that the networks trained using transverse velocity outperform other networks, even when subjected to aggressive data corruption. We then train the network to classify flow patterns instantaneously, using a spatially-distributed array of sensors and a single 'one time' sensory measurement. The network, based on a handful of spatially-distributed sensors, exhibits remarkable accuracy in flow classification. These results lay the groundwork for developing learning algorithms for the dynamic deployment of sensory arrays in unsteady flows.


Assuntos
Robótica/métodos , Algoritmos , Animais , Biomimética/métodos , Desenho de Equipamento/métodos , Sistema da Linha Lateral/fisiologia , Redes Neurais de Computação
9.
Bioinspir Biomim ; 13(2): 025003, 2018 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-29334075

RESUMO

Unsteady flows contain information about the objects creating them. Aquatic organisms offer intriguing paradigms for extracting flow information using local sensory measurements. In contrast, classical methods for flow analysis require global knowledge of the flow field. Here, we train neural networks to classify flow patterns using local vorticity measurements. Specifically, we consider vortex wakes behind an oscillating airfoil and we evaluate the accuracy of the network in distinguishing between three wake types, 2S, 2P + 2S and 2P + 4S. The network uncovers the salient features of each wake type.


Assuntos
Biomimética/métodos , Redes Neurais de Computação , Biomimética/instrumentação , Simulação por Computador , Hidrodinâmica , Aprendizado de Máquina , Fenômenos Físicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA