1.
Trials ; 25(1): 459, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38971756

RESUMO

BACKGROUND: Particulate contamination due to infusion therapy (administration of parenteral nutrition and medications) carries a potential health risk for infants in neonatal intensive care units (NICUs). This particulate consists of metals, drug crystals, glass fragments, or cotton fibers and can be generated by drug packaging, incomplete reconstitution, and chemical incompatibilities. In-line filters have been shown to remove micro-organisms, endotoxin, air, and particles in critically ill adults and older infants, but its benefits in newborn remain to be demonstrated. Moreover, 50% of inflammatory episodes in the setting of NICUs are blood culture-negative. These episodes could be partly related to the presence of particles in the infusion lines. METHODS: A multicenter randomized single-blind controlled trial was designed. All infants admitted to NICUs for which prolonged infusion therapy is expected will be enrolled in the study and randomized to the Filter or Control arm. All patients will be monitored until discharge, and data will be analyzed according to a "full analysis set." The primary outcome is the frequency of patients with at least one sepsis-like event, defined by any association of suspected sepsis symptoms with a level of c-reactive protein (CRP) > 5 mg/L in a negative-culture contest. The frequency of sepsis, phlebitis, luminal obstruction, and the duration of mechanical ventilation and of catheter days will be evaluated as secondary outcomes. The sample size was calculated at 368 patients per arm. DISCUSSION: This is the first multicenter randomized control trial that compares in-line filtration of parenteral nutrition and other intravenous drugs to infusion without filters. Sepsis-like events are commonly diagnosed in clinical practice and are more frequent than sepsis in a positive culture contest. The risk of these episodes in the target population is estimated at 30-35%, but this data is not confirmed in the literature. If the use of in-line filters results in a significant decrease in sepsis-like events and/or in any other complications, the use of in-line filters in all intravenous administration systems may be recommended in NICUs. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05537389, registered on 12 September 2022 ( https://classic. CLINICALTRIALS: gov/ct2/show/results/NCT05537389?view=results ).


Assuntos
Filtração , Unidades de Terapia Intensiva Neonatal , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Recém-Nascido , Filtração/instrumentação , Método Simples-Cego , Infusões Intravenosas , Sepse , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Nutrição Parenteral/efeitos adversos , Nutrição Parenteral/métodos , Resultado do Tratamento , Proteína C-Reativa/análise
2.
Front Pediatr ; 12: 1309923, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38283629

RESUMO

Introduction: Breastfeeding naturally enables the coordination of sucking, swallowing, and respiration patterns for safe feeding. When breastfeeding is not possible a feeding device that releases milk in response to intra-oral vacuum could potentially offer improved coordination of sucking, swallowing, and breathing patterns compared to conventional devices. The aim of the study is to evaluate the effect of a valved infant-bottle with an ergonomic teat compared to a standard infant-bottle. Methods: This unblinded randomized controlled trial focused on late preterm infants fed by bottle for at least three meals over the day, admitted to the Neonatal Unit of Sant'Anna Hospital (Turin, Italy). Infants were randomized to be fed with a valved infant-bottle with an ergonomic teat (B-EXP arm) or with a standard infant-bottle (B-STD arm). Monitoring included a simultaneous synchronized recording of sucking, swallowing and respiration. The main outcome was the swallowing/breathing ratio. Results: Forty infants (20 B-EXP arm; 20 B-STD arm) with a median gestational age of 35.0 weeks (IQR 35.0-36.0 weeks) completed the study. Four infants were censored for the presence of artifacts in the polygraphic traces. The median swallowing/breathing ratio was 1.11 (1.03-1.23) in the B-EXP arm and 1.75 (1.21-2.06) in the B-STD (p = .003). A lower frequency of swallowing events during the inspiratory phase of breathing was observed in B-EXP arm compared with B-STD arm (p = 0.013). Discussion: The valved infant-bottle with an ergonomic teat improves the coordination of sucking-swallowing-respiration and limits the risk of inhalation reducing the frequency of swallowing during the inspiratory phase.