Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Scand J Gastroenterol ; 54(8): 1022-1026, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31322445

RESUMO

Background: Obesity is one of the main factors of transient elastography (TE) failure, considering body mass index (BMI) ≥28 kg/m2 as a limiting factor. The XL probe was designed to overcome this limitation. Aim: To compare the feasibility of the M and XL probes in patients with BMI ≥ 28 kg/m2, to evaluate differences in mean values of controlled attenuation parameter (CAP) and liver stiffness measurement (LSM) between the two probes and find predictive factors of TE failure. Material and methods: Prospective study, including all patients with BMI ≥ 28 kg/m2 consecutively admitted for TE. Results: Included 161 patients. Measurements with M probe were reliable in 69.6% of the patients, with 68.2% of valid measurements in obese population and 58.9% in patients with skin-capsule distance (SCD) >25 mm. In 40 patients (81.6%) with an invalid M probe measurement, a reliable result was obtained with XL probe. We found that SCD >25 mm was the only predictor of M probe failure (OR: 4.9, CI: 1.64-14.63, p = .004). In those patients in which TE was possible with both probes (n = 112), mean CAP was 304 ± 49 dB/m2 with M probe and 301 ± 50 dB/m2 with XL probe (p = .59). Regarding liver stiffness, a mean value of 7.58 ± 3.47 kpas was obtained with the M probe and 6.21 ± 3.44 kpas with the XL probe (p < .001). Conclusion: There is a reliable applicability of the M probe in a high number (68.2%) of patients with a BMI ≥30 kg/m2. A SCD >25 mm was the only predictive factor of M probe failure. Mean values of LSM with XL probe were lower than those obtained with M probe.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Cirrose Hepática/diagnóstico por imagem , Sobrepeso/diagnóstico por imagem , Transdutores , Adulto , Índice de Massa Corporal , Desenho de Equipamento , Feminino , Humanos , Fígado/diagnóstico por imagem , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Chaos ; 28(8): 085709, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30180621

RESUMO

This work summarizes the research related to digital speech signal processing with recurrence quantification analysis (RQA) applied to voice disorder assessment. The main motivation for these studies is the fact that RQA is able to exploit the nonlinear dynamical nature of the speech production system. Due to the use of recurrence quantification measures to represent the behavior of speech signals, promising results were obtained in the characterization and classification of laryngeal pathologies and voice disorders. These contributions may help one to evaluate the usability and efficiency of RQA in vocal disorder assessment.


Assuntos
Auxiliares de Comunicação para Pessoas com Deficiência , Bases de Dados Factuais , Modelos Biológicos , Prega Vocal/fisiopatologia , Distúrbios da Voz/fisiopatologia , Humanos
3.
Stud Health Technol Inform ; 216: 1047, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26262346

RESUMO

This paper deals with the discrimination between healthy and pathological speech signals using recurrence plots and wavelet transform with texture features. Approximation and detail coefficients are obtained from the recurrence plots using Haar wavelet transform, considering one decomposition level. The considered laryngeal pathologies are: paralysis, Reinke's edema and nodules. Accuracy rates above 86% were obtained by means of the employed method.


Assuntos
Diagnóstico por Computador/métodos , Doenças da Laringe/diagnóstico , Espectrografia do Som/métodos , Distúrbios da Fala/diagnóstico , Distúrbios da Fala/etiologia , Medida da Produção da Fala/métodos , Análise de Ondaletas , Algoritmos , Humanos , Doenças da Laringe/complicações , Aprendizado de Máquina , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Voice ; 28(5): 565-73, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24836362

RESUMO

OBJECTIVE: To analyze the accuracy of recurrence measurements, both isolated and combined, to assess the intensity of vocal disorders in children. METHOD: A total of 93 children of both sexes (48 girls and 45 boys), aged between 3 and 10 years, participated. The vocal-deviation intensity was evaluated by the consensus of three speech therapists from the pronunciation of vowel /ε/ using the visual analog scale. In the acoustic analysis, eight recurrence plot characteristics were evaluated and extracted with neighborhood radius values that maintained the recurrence rate at 1%, 2%, 3%, 4%, and 5%. The classification was performed using quadratic discriminant analysis applied for individual and combined measurements. The performance was evaluated by measuring the accuracy, which related the cases correctly classified to all the analyzed cases. RESULTS: In the classification cases concerning individual measure performance, the trapping time and maximum length of the diagonal lines showed the best classification potential to discriminate between healthy and disturbed voices, with accuracy rates above 80%. In the healthy and mild deviation cases, the trend (TREND) measure was also relevant. For the mild versus moderate deviation classification, the best performance was obtained by the TREND measure (85.00% ± 7.64%). A gain was obtained in the classification rate when the measures of recurrence were combined, reaching an accuracy of 95.00% ± 5.00%, for discriminating between healthy voices and those with mild deviation. CONCLUSIONS: The measures of recurrence, either alone or combined, may be useful in detecting healthy and disturbed voices and in differentiating the intensity of vocal disorders in children.


Assuntos
Monitorização Fisiológica/métodos , Dinâmica não Linear , Fonação/fisiologia , Distúrbios da Voz/diagnóstico , Qualidade da Voz , Voz/fisiologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Acústica da Fala , Medida da Produção da Fala/métodos , Distúrbios da Voz/fisiopatologia
5.
Plant Sci ; 213: 30-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24157205

RESUMO

In several plant tissues, programmed cell death (PCD) is mediated by the combined action of cysteine peptidases, namely KDEL-tailed cysteine peptidases (KDEL-CysEP) and vacuolar processing enzymes (VPE). Here, we performed a search of the draft genome of Jatropha curcas L. (Euphorbiaceae) and identified 2 genes for KDEL-CysEP (Jc-CysEP1 and Jc-CysEP2) and 3 genes for VPE (Jc-ßVPE, Jc-γVPE and Jc-δVPE) and determined the expression patterns of these genes by RT-qPCR in integument and cellular endosperm of seeds collected at seven different developmental stages. We were able to demonstrate that the expression of Jc-CysEP1, Jc-CysEP2, Jc-ßVPE and Jc-γVPE proceeded rapidly from Stage IV, with Jc-CysEP2 displaying the highest relative expression; expression of Jc-δVPE could not be detected in any of the tissues/developmental stages analyzed. Additionally, we showed that the expression pattern of these peptidases correlates with anatomical changes in integument and cellular endosperm, thus suggesting a role for both classes of peptidases in PCD and in protein processing, both of which occur simultaneously in each of these tissues.


Assuntos
Cisteína Endopeptidases/genética , Regulação da Expressão Gênica de Plantas , Genoma de Planta/genética , Jatropha/genética , Apoptose , Cisteína/metabolismo , Cisteína Endopeptidases/metabolismo , Primers do DNA/genética , Endosperma/citologia , Endosperma/genética , Endosperma/crescimento & desenvolvimento , Endosperma/fisiologia , Genômica , Jatropha/citologia , Jatropha/crescimento & desenvolvimento , Jatropha/fisiologia , Oligopeptídeos , Filogenia , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo , Sinais Direcionadores de Proteínas , Sementes/citologia , Sementes/genética , Sementes/crescimento & desenvolvimento , Sementes/fisiologia
6.
Insuf. card ; 13(2): 93-96, 01/06/2018. ilus
Artigo em Português | LILACS | ID: biblio-914696

RESUMO

A pericardite constritiva (PC) é uma condição clínica caracterizada pela presença de inflamação do tecido pericárdico, culminando em constrição cardíaca. A tuberculose pode acometer o pericárdio e levar à uma condição clínica conhecida como pericardite tuberculosa (PT). Relata-se o caso de um paciente jovem, internado com queixas de insuficiência cardíaca e quadro de PC em que o diagnóstico etiológico de PT foi confirmado por exclusão e resposta à terapêutica.


Assuntos
Humanos , Insuficiência Cardíaca , Pericardite Constritiva , Tuberculose
7.
Insuf. card ; 13(2): 97-100, 01/06/2018. ilus
Artigo em Espanhol | LILACS | ID: biblio-914697

RESUMO

La pericarditis constrictiva (PC) es una condición clínica caracterizada por la presencia de inflamación del tejido pericárdico, culminando en constricción cardíaca. La tuberculosis puede afectar al pericardio y llevarlo a una condición clínica conocida como pericarditis tuberculosa (PT). Se relata el caso de un paciente joven, internado con síntomas de insuficiencia cardíaca y cuadro.


Assuntos
Humanos , Insuficiência Cardíaca , Pericardite Constritiva , Tuberculose
8.
Int. j. cardiovasc. sci. (Impr.) ; 31(2): f:143-l:151, mar.-abr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-882060

RESUMO

Background: Few studies have used portable gas analyzers during the 6-minute walk test (6MWT) in patients with heart failure and normal ejection fraction (HFNEF). Objectives: To analyze the kinetics of hemodynamic, ventilatory, and metabolic variables in patients with HFNEF during the T6m using a portable gas analyzer. Methods: Prospective, analytical study with an intentional, non-probabilistic, convenience sample. In total, 24 patients with HFNEF and past hospital admissions due to a clinical diagnosis of heart failure (HF) were included using the 2007 criteria established by the European Society of Cardiology. Three assessments were performed: 6MWT familiarization, 6MWT with the portable gas analyzer, and cardiopulmonary exercise test (CPET). Results: The heart rates (HRs) and the peak VO 2 at the end of the 6MWT corresponded to 85.7% and 86.45% of the values obtained during the CPET. The final HRs after the T6m were equivalent to those obtained at the CPET anaerobic threshold (AT), with relative VO 2 values at the end of the 6MWT above the VO 2 of the CPET AT. There was no difference between the maximum respiratory quotient (RQ) values in these two tests, which were both above 1.0. The VE/VO 2 slope descended initially and then ascended significantly after the fifth minute of the test, estimating the identification of the AT. Conclusions: In patients with HFNEF, the 6MWT represents an almost maximum effort, and is performed above the CPET AT and 85% above the maximum HR and the CPET peak VO 2 , with a maximum RQ similar to that in the CPET


Fundamentos: Poucos estudos utilizaram analisadores de gases portáteis no teste da caminhada de seis minutos (T6m) em portadores de insuficiência cardíaca com fração de ejeção normal (ICFEN). Objetivos: Analisar a cinética das variáveis hemodinâmicas, ventilatórias e metabólicas utilizando analisador de gases portátil em portadores de ICFEN durante o T6m. Métodos: Estudo prospectivo, analítico, com amostra não probabilística, intencional e por conveniência. Foram estudados 24 pacientes portadores de ICFEN com passado de internação por clínica de insuficiência cardíaca (IC), incluídos pelos critérios da European Society of Cardiology 2007. Realizaram-se três avaliações: T6m de aprendizado, T6m com o analisador de gases portátil e teste de esforço cardiopulmonar (TECP). Resultados: As frequências cardíacas (FC) e o consumo de oxigênio (VO 2 ) pico ao final do T6m corresponderam a 85,7% e 86,45% dos valores obtidos no TECP. As FC finais no T6m foram equivalentes às obtidas no limiar anaeróbio (LA) do TECP, com valores de VO 2 relativo ao final do T6m acima do VO 2 no LA do TECP. Não houve diferença entre os valores máximos do quociente respiratório (QR) entre os dois testes, ambos acima de 1,0. A curva de VE/VO 2 demonstrou descenso com posterior ascensão significativa após o quinto minuto de teste, estimando-se a identificação do LA. Conclusões: Para pacientes com ICFEN, o T6m representa um esforço quase máximo, sendo executado acima do LA do TECP e acima dos 85% da FC máxima e do VO 2 pico do TECP, com QR máximo semelhante ao do TECP


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Gasometria/métodos , Exercício Físico , Insuficiência Cardíaca , Volume Sistólico , Teste de Caminhada/métodos , Índice de Massa Corporal , Doença da Artéria Coronariana , Diabetes Mellitus , Dislipidemias , Hipertensão , Obesidade , Estudos Prospectivos , Fatores de Risco , Interpretação Estatística de Dados
9.
Rev. bras. med. esporte ; 20(1): 41-46, Jan-Feb/2014. tab, graf
Artigo em Português | LILACS | ID: lil-704728

RESUMO

INTRODUÇÃO: O teste de esforço cardiopulmonar (TECP) fornece dados que orientam tratamento, prognóstico e tomadas de decisões. Entretanto, seu uso na insuficiência cardíaca de fração de ejeção normal (ICFEN) ainda não está bem esclarecido, em especial considerando novas variáveis que vêm despontando. OBJETIVOS: Comparar o comportamento das principais variáveis diagnósticas e prognósticas do TECP entre dois grupos: pacientes com insuficiência cardíaca de fração de ejeção reduzida (ICFER) e pacientes com ICFEN. MÉTODOS: Foram avaliados 36 pacientes com insuficiência cardíaca em classe funcional II-III da NYAH: 20 com ICFEN e 16 com ICFER do ambulatório de insuficiência cardíaca do Hospital Universitário Antônio Pedro (UFF). Os pacientes do Grupo ICFER selecionados foram os com FE < 35% e os do grupo ICFEN seguiram os critérios diagnósticos da Sociedade Europeia de Cardiologia de 2007. Realizou-se TECP, em esteira com protocolo de rampa, com analisador de gases VO2000. Foram aplicados teste t de Student, Mann-Whitney, teste de Fisher, modelo linear generalizado e de Cochran-Mantel-Haenszel para as análises estatísticas. RESULTADOS: O grupo ICFEN apresentou níveis mais elevados da pressão arterial em repouso, na resposta ao esforço, na potência circulatória e ventilatória, além de um maior tempo de recuperação da cinética do consumo de oxigênio. Não houve diferença em relação a outras variáveis prognósticas do TECP para o grupo ICFER. CONCLUSÕES: A pressão arterial de repouso e em esforço, a potência circulatória e ventilatória e a cinética de recuperação do VO2 (T1/2) foram as variáveis que apresentaram maior ...


INTRODUCTION: The cardiopulmonary exercise testing (CPX) provides data that guide treatment, prognosis and decision making. However its use in heart failure with normal ejection fraction (HFnEF) is still not all clear, especially considering new variables that are emerging. OBJECTIVE: To compare the behavior of key diagnostic and prognostic variables of CPX testing between two groups; patients with heart with reduced ejection fraction of (HfrEF) and those with HFnEF). METHODS: 36 patients with heart failure were evaluated in Nyah functional class II-III: 20 with HFnEF and 16 patients with HFrEF at the Hospital Universitário Antônio Pedro (UFF). The patients from HFrEF group were those with EF<35%, and those from the HFnEF group follow the diagnostic criteria of the European Society of Cardiology 2007. CPX was performed on a treadmill with a ramp protocol, with gas analyzer VO2000. The Student t test, Mann-Whitney test and Fisher, generalized linear model and the Cochran-Mantel-Haenszel test for statistical analysis were applied. RESULTS: The HFnEF group presented higher levels of blood pressure at rest, higher response to exertion, higher circulatory and ventilatory power, and longer recovery kinetics of oxygen uptake. There was no difference in relation to other prognostic variables of CPX in the HFrEF group. CONCLUSIONS: The blood pressure at rest and during exercise, the circulatory and ventilatory capacity and the kinetics of VO2 (T1/2), were the variables that showed the highest discriminative value between the two populations by CPX. .


INTRODUCCIÓN: La prueba de esfuerzo cardiopulmonar (PECP) suministra datos que orientan tratamiento, pronóstico y tomas de decisiones. No obstante, su uso en la insuficiencia cardíaca de fracción de eyección normal (ICFEN) todavía no está bien aclarado, en especial, considerando nuevas variables que vienen apareciendo. OBJETIVOS: Comparar el comportamiento de las variables principales de diagnóstico y de pronóstico de la PECP, entre dos grupos: pacientes con insuficiencia cardíaca de fracción de eyección reducida (ICFER) y pacientes con ICFEN. MÉTODOS: Se evaluaron 36 pacientes con insuficiencia cardíaca en clase funcional II-III de la NYAH: 20 con ICFEN y 16 con ICFER del dispensario de insuficiencia cardíaca del Hospital Universitário Antonio Pedro (UFF). Los pacientes del grupo ICFER fueron seleccionados con FE <35% y el grupo ICFEN siguieron los diagnósticos de la Sociedad Europea de Cardiología 2007 criterios. Se realizó la PECP, en estera con regulador de rampa, con analizador de gases VO2000. Se aplicaron las pruebas t de Student, Mann-Whitney, prueba de Fisher, modelo linear generalizado y de Cochran-Mantel-Haenszel para los análisis estadísticos. RESULTADOS: El grupo ICFEN presentó niveles más altos de presión arterial en reposo, en la respuesta al esfuerzo, en las potencias circulatoria y ventilatoria, además de un tempo más prolongado de recuperación de la cinética del consumo de oxígeno. No hubo diferencia en relación con otras variables de pronóstico de la PECP para el grupo ICFER. CONCLUSIONES: La presión arterial de reposo y en esfuerzo, las potencias circulatoria y ventilatoria y la cinética de recuperación del VO2 (T1/2) fueron las variables que presentaron más valor discriminativo entre los grupos según la PECP. .

10.
Rev. bras. eng. biomed ; 29(1): 3-14, jan.-mar. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-670969

RESUMO

Análise acústica tem sido sugerida como uma ferramenta auxiliar não invasiva e de baixo custo ao diagnóstico de patologias laríngeas. Diversas são as técnicas empregadas, entre as quais técnicas baseadas no modelo linear de produção da fala e na análise dinâmica não linear de sinais de vozes. O primeiro método é baseado na Teoria fonte-filtro, em que a fonte é a laringe e o filtro é o trato vocal. Nesse modelo, os sons surdos são modelados por uma fonte de ruído aleatório e os sons sonoros por um trem de impulsos na frequência fundamental do locutor. Na abordagem não linear são considerados aspectos da voz humana, não explorados no modelo linear, tais como: variação temporal da forma do trato vocal, as ressonâncias associadas à sua fisiologia, as perdas devido ao atrito nas paredes internas do trato vocal, a radiação do som nos lábios, o acoplamento nasal e o comportamento dinâmico associado à vibração das pregas vocais. Neste trabalho são associadas as duas abordagens e avaliado o desempenho na classificação com as características, de forma individual, e a partir da combinação das mesmas. São empregadas oito medidas oriundas da análise dinâmica não linear (dimensão de correlação, quatro medidas de entropia, expoente de Hurst, maior expoente de Lyapunov e o primeiro mínimo da função de informação mútua), além de coeficientes LPC, obtidos a partir da análise preditiva linear. Os resultados sugerem a viabilidade da técnica empregada para a discriminação entre vozes saudáveis e patológicas em geral, como também entre vozes afetadas por patologias laríngeas distintas como edema, nódulos e paralisia nas pregas vocais.


Acoustic analysis has been suggested as a noninvasive aiding and low cost tool for laryngeal disease diagnosis. Several techniques are employed using either the linear model of speech production, or the nonlinear dynamic analysis of voice signals. The first method is based on source-filter theory, in which the source is the larynx and the filter is the vocal tract. In this model, the unvoiced sounds are modeled by a random noise source and the voiced ones by impulse train at the speaker fundamental frequency. In nonlinear approach, aspects of the human voice are considered, not explored in the linear model, such as temporal variation of the vocal tract shape, resonances associated with its physiology, losses due to friction in the vocal tract inner walls, sound radiation in the lips, nose coupling and dynamic behavior associated with vocal fold vibration. This work combines the two approaches and evaluates the performance in classifying the features individually, and from their combination. Eight measures are employed derived from the nonlinear dynamic analysis (correlation dimension, four entropy measures, Hurst exponent, the largest Lyapunov exponent and the first minimum of mutual information function), besides LPC coefficients obtained from linear predictive analysis. The results suggest the feasibility of the employed technique to discriminate between healthy and pathological voices in general, but also among specific laryngeal diseases as vocal fold edema, nodules and paralysis.

13.
J. bras. med ; 74(5): 50-63, maio 1998. ilus
Artigo em Português | LILACS | ID: lil-421735

RESUMO

Os autores apresentam uma revisão da literatura atualizada, enfocando principalmente aspectos referentes às novas modalidades de diagnóstico e tratamento dos tumores carcinóides, assim como da síndrome carcinóide, analisando sua efetividade e eficácia


Assuntos
Humanos , Tumor Carcinoide , Síndrome do Carcinoide Maligno
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA