Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 32(29): 7277-83, 2016 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-27364477

RESUMO

Cell aggregation plays a key role in biofilm formation and pathogenesis of Staphylococcus species. Although the molecular basis of aggregation in Staphylococci has already been extensively investigated, the influence of environmental factors, such as ionic strength, remains poorly understood. In this paper, we report a new type of cellular aggregation of Staphylococci that depends solely on ionic strength. Seven strains out of 14, all belonging to staphylococcal species, formed large cell clusters within minutes in buffers of ionic strength ranging from 1.5 to 50 mM, whereas isolates belonging to other Gram-positive species did not display this phenotype. Atomic force microscopy (AFM) with chemically functionalized tips provided direct evidence that ionic strength modulates cell surface adhesive properties through changes in cell surface charge. The optimal ionic strength for aggregation was found to be strain dependent, but in all cases, bacterial aggregates formed at an ionic strength of 1.5-50 mM were rapidly dispersed in a solution of higher ionic strength, indicating a reversibility of the cell aggregation process. These findings suggest that some staphylococcal isolates can respond to ionic strength as an external stimulus to trigger rapid cell aggregation in a way that has not yet been reported.


Assuntos
Staphylococcus/química , Microscopia de Força Atômica , Concentração Osmolar , Staphylococcus/ultraestrutura
2.
IEEE Trans Biomed Circuits Syst ; 10(2): 364-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25974947

RESUMO

We present a 16 × 16 CMOS biosensor array aiming at impedance detection of whole-cell bacteria. Each 14 µm × 16 µm pixel comprises high-sensitive passivated microelectrodes connected to an innovative readout interface based on charge sharing principle for capacitance-to-voltage conversion and subthreshold gain stage to boost the sensitivity. Fabricated in a 0.25 µm CMOS process, the capacitive array was experimentally shown to perform accurate dielectric measurements of the electrolyte up to electrical conductivities of 0.05 S/m, with maximal sensitivity of 55 mV/fF and signal-to-noise ratio (SNR) of 37 dB. As biosensing proof of concept, real-time detection of Staphylococcus epidermidis binding events was experimentally demonstrated and provides detection limit of ca. 7 bacteria per pixel and sensitivity of 2.18 mV per bacterial cell. Models and simulations show good matching with experimental results and provide a comprehensive analysis of the sensor and circuit system. Advantages, challenges and limits of the proposed capacitive biosensor array are finally described with regards to literature. With its small area and low power consumption, the present capacitive array is particularly suitable for portable point-of-care (PoC) diagnosis tools and lab-on-chip (LoC) systems.


Assuntos
Técnicas Biossensoriais/instrumentação , Staphylococcus epidermidis/isolamento & purificação , Capacitância Elétrica , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Microeletrodos , Sistemas Automatizados de Assistência Junto ao Leito , Razão Sinal-Ruído
3.
Lab Chip ; 15(15): 3183-91, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26120099

RESUMO

We present the co-integration of CMOS-compatible Al/Al2O3 interdigitated microelectrodes (IDEs) with an electrokinetic-driven macroelectrode for sensitive detection of whole-cell bacteria in a microfluidic channel. Two frequency ranges applied to the macroelectrode were identified to notably increase the bacterial coverage of the impedimetric sensor per unit time. Around 10 kHz, the bacterial cells were directed towards the IDE center thanks to AC electroosmosis (AC-EO) and the sensor capacitance linearly increased, achieving a limit of detection (LoD) of 3.5 × 10(5) CFU mL(-1) after an incubation time of 20 min with Staphylococcus epidermidis. At 63 MHz precisely, a resonance effect due to the device was found to dramatically increase the trapping of S. epidermidis on the sensor periphery, due to the combined actions of short-range contactless dielectrophoresis (cDEP) and long-range Joule heating electrothermal (J-ET) flow. Thanks to a flow-based method, the bacterial cells were redirected towards the sensor center and an LoD of 10(5) CFU mL(-1) was achieved within 20 min of incubation, which is almost two orders of magnitude better than the impedimetric sensor alone. Analytical models and 2D simulations using the Maxwell stress tensor (MST) provide a comprehensive analysis of the experimental results, especially about the spectral balance between cDEP, AC-EO and J-ET accounting for the 33-nm thick insulating layer atop the electrodes. Electrode CMOS compatibility confers portability, miniaturization and affordability capabilities for building point-of-care (PoC) diagnostic tests in a lab-on-a-chip (LoC).


Assuntos
Contagem de Colônia Microbiana/instrumentação , Eletro-Osmose/instrumentação , Eletroforese/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Staphylococcus epidermidis/isolamento & purificação , Contagem de Colônia Microbiana/métodos , Simulação por Computador , Impedância Elétrica , Desenho de Equipamento , Staphylococcus epidermidis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA