Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
N Engl J Med ; 365(6): 518-26, 2011 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-21830966

RESUMO

BACKGROUND: More than 30% of patients with pleural infection either die or require surgery. Drainage of infected fluid is key to successful treatment, but intrapleural fibrinolytic therapy did not improve outcomes in an earlier, large, randomized trial. METHODS: We conducted a blinded, 2-by-2 factorial trial in which 210 patients with pleural infection were randomly assigned to receive one of four study treatments for 3 days: double placebo, intrapleural tissue plasminogen activator (t-PA) and DNase, t-PA and placebo, or DNase and placebo. The primary outcome was the change in pleural opacity, measured as the percentage of the hemithorax occupied by effusion, on chest radiography on day 7 as compared with day 1. Secondary outcomes included referral for surgery, duration of hospital stay, and adverse events. RESULTS: The mean (±SD) change in pleural opacity was greater in the t-PA-DNase group than in the placebo group (-29.5±23.3% vs. -17.2±19.6%; difference, -7.9%; 95% confidence interval [CI], -13.4 to -2.4; P=0.005); the change observed with t-PA alone and with DNase alone (-17.2±24.3 and -14.7±16.4%, respectively) was not significantly different from that observed with placebo. The frequency of surgical referral at 3 months was lower in the t-PA-DNase group than in the placebo group (2 of 48 patients [4%] vs. 8 of 51 patients [16%]; odds ratio for surgical referral, 0.17; 95% CI, 0.03 to 0.87; P=0.03) but was greater in the DNase group (18 of 46 patients [39%]) than in the placebo group (odds ratio, 3.56; 95% CI, 1.30 to 9.75; P=0.01). Combined t-PA-DNase therapy was associated with a reduction in the hospital stay, as compared with placebo (difference, -6.7 days; 95% CI, -12.0 to -1.9; P=0.006); the hospital stay with either agent alone was not significantly different from that with placebo. The frequency of adverse events did not differ significantly among the groups. CONCLUSIONS: Intrapleural t-PA-DNase therapy improved fluid drainage in patients with pleural infection and reduced the frequency of surgical referral and the duration of the hospital stay. Treatment with DNase alone or t-PA alone was ineffective. (Funded by an unrestricted educational grant to the University of Oxford from Roche UK and by others; Current Controlled Trials number, ISRCTN57454527.).


Assuntos
Desoxirribonucleases/uso terapêutico , Fibrinolíticos/uso terapêutico , Doenças Pleurais/tratamento farmacológico , Derrame Pleural/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Adulto , Idoso , Desoxirribonucleases/efeitos adversos , Método Duplo-Cego , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Instilação de Medicamentos , Análise de Intenção de Tratamento , Modelos Lineares , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doenças Pleurais/diagnóstico por imagem , Doenças Pleurais/mortalidade , Derrame Pleural/diagnóstico por imagem , Radiografia , Ativador de Plasminogênio Tecidual/efeitos adversos
2.
J Sleep Res ; 18(3): 329-36, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19549077

RESUMO

Obstructive sleep apnoea (OSA) is associated with cardiovascular morbidity and may precipitate cardiac dysrhythmias. Uncontrolled reports suggest that continuous positive airway pressure (CPAP) may reduce dysrhythmia frequency and resting heart rate. We undertook a randomised controlled trial of therapeutic CPAP and compared with a subtherapeutic control which included an exploration of changes in dysrhythmia frequency and heart rate. Values are expressed as mean (SD). Eighty-three men [49.5 (9.6) years] with moderate-severe OSA [Oxygen Desaturation Index, 41.2 (24.3) dips per hour] underwent 3-channel 24-h electrocardiograms during normal daily activities, before and after 1 month of therapeutic (n = 43) or subtherapeutic (n = 40) CPAP. Recordings were manually analysed for mean heart rate, pauses, bradycardias, supraventricular and ventricular dysrhythmias. The two groups were well matched for age, body mass index, OSA severity, cardiovascular risk factors and history. Supraventricular ectopics and ventricular ectopics were frequently found in 95.2% and 85.5% of patients, respectively. Less common were sinus pauses (42.2%), episodes of bradycardia (12%) and ventricular tachycardias (4.8%). Compared with subtherapeutic control, CPAP reduced mean 24-h heart rate from 83.0 (11.5) to 79.7 (9.8) (P < 0.002) in the CPAP group compared with a non-significant rise (P = 0.18) from 79.0 (10.4) to 79.9 (10.4) in the subtherapeutic group; this was also the case for the day period analysed separately. There was no significant change in the frequencies of dysrhythmias after CPAP. Four weeks of CPAP therapy reduces mean 24-h heart rate possibly due to reduced sympathetic activation but did not result in a significant decrease in dysrhythmia frequency.


Assuntos
Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Pressão Positiva Contínua nas Vias Aéreas , Eletrocardiografia Ambulatorial , Frequência Cardíaca/fisiologia , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Adulto , Ritmo Circadiano/fisiologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Sistema Nervoso Simpático/fisiopatologia
3.
Am J Respir Crit Care Med ; 168(9): 1109-14, 2003 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-12928310

RESUMO

Heart failure is associated with Cheyne-Stokes breathing, which fragments patients' sleep. Correction of respiratory disturbance may reduce sleep fragmentation and excessive daytime sleepiness. This randomized prospective parallel trial assesses whether nocturnal-assist servoventilation improves daytime sleepiness compared with the control. A total of 30 subjects (29 male) with Cheyne-Stokes breathing (mean apnea-hypopnea index 19.8 [SD 2.6] and stable symptomatic chronic heart failure (New York Heart Association Class II-IV) were treated with 1 month's therapeutic (n = 15) or subtherapeutic adaptive servoventilation. Daytime sleepiness (Osler test) was measured before and after the trial with change in measured sleepiness the primary endpoint. Secondary endpoints included brain natriuretic peptide levels and catecholamine excretion. Active treatment reduced excessive daytime sleepiness; the mean Osler change was +7.9 minutes (SEM 2.9), when compared with the control, the change was -1.0 minutes (SEM, 1.7), and the difference was 8.9 minutes (95% confidence interval, 1.9-15.9 minutes; p = 0.014, unpaired t test). Significant falls occurred in plasma brain natriuretic peptide and urinary metadrenaline excretion. We conclude that adaptive servoventilation produces an improvement in excessive daytime sleepiness in patients with Cheyne-Stokes breathing and chronic heart failure. This study suggests improvements in neurohormonal activation with this treatment.


Assuntos
Respiração de Cheyne-Stokes/etiologia , Respiração de Cheyne-Stokes/terapia , Insuficiência Cardíaca/complicações , Respiração com Pressão Positiva , Idoso , Dióxido de Carbono/sangue , Catecolaminas/urina , Distúrbios do Sono por Sonolência Excessiva/etiologia , Distúrbios do Sono por Sonolência Excessiva/terapia , Método Duplo-Cego , Feminino , Nível de Saúde , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/urina , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Polissonografia , Estudos Prospectivos , Apneia do Sono Tipo Central/etiologia , Apneia do Sono Tipo Central/terapia , Inquéritos e Questionários
4.
Lancet ; 359(9302): 204-10, 2002 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-11812555

RESUMO

BACKGROUND: Obstructive sleep apnoea is associated with raised blood pressure. If blood pressure can be reduced by nasal continuous positive airway pressure (nCPAP), such treatment could reduce risk of cardiovascular disease in patients with obstructive sleep apnoea. Our aim was to see whether nCPAP for sleep apnoea reduces blood pressure compared with the most robust control intervention subtherapeutic nCPAP. METHODS: We did a randomised parallel trial to compare change in blood pressure in 118 men with obstructive sleep apnoea (Epworth score > 9, and a > 4% oxygen desaturation index of > 10 per h) who were assigned to either therapeutic (n=59) or subtherapeutic (59) nCPAP (about 1 cm H(2)O pressure) for 1 month. The primary outcome was the change in 24-h mean blood pressure. Secondary outcomes were changes in systolic, diastolic, sleep, and wake blood pressure, and relations between blood pressure changes, baseline blood pressure, and severity of sleep apnoea. FINDINGS: Therapeutic nCPAP reduced mean arterial ambulatory blood pressure by 2.5 mm Hg (SE 0.8), whereas subtherapeutic nCPAP increased blood pressure by 0.8 mm Hg (0.7) (difference -3.3 [95% CI -5.3 to -1.3]; p=0.0013, unpaired t test). This benefit was seen in both systolic and diastolic blood pressure, and during both sleep and wake. The benefit was larger in patients with more severe sleep apnoea than those who had less severe apnoea, but was independent of the baseline blood pressure. The benefit was especially large in patients taking drug treatment for blood pressure. INTERPRETATION: In patients with most severe sleep apnoea, nCPAP reduces blood pressure, providing significant vascular risk benefits, and substantially improving excessive daytime sleepiness and quality of life.


Assuntos
Pressão Sanguínea , Respiração com Pressão Positiva , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Monitorização Ambulatorial da Pressão Arterial , Método Duplo-Cego , Humanos , Hipertensão/complicações , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Apneia Obstrutiva do Sono/sangue , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/fisiopatologia , Fases do Sono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA