Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Proc Natl Acad Sci U S A ; 111(22): 8161-6, 2014 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-24843132

RESUMO

The clinical use of high intensity focused ultrasound (HIFU) therapy for noninvasive tissue ablation has been recently gaining momentum. In HIFU, ultrasound energy from an extracorporeal source is focused within the body to ablate tissue at the focus while leaving the surrounding organs and tissues unaffected. Most HIFU therapies are designed to use heating effects resulting from the absorption of ultrasound by tissue to create a thermally coagulated treatment volume. Although this approach is often successful, it has its limitations, such as the heat sink effect caused by the presence of a large blood vessel near the treatment area or heating of the ribs in the transcostal applications. HIFU-induced bubbles provide an alternative means to destroy the target tissue by mechanical disruption or, at its extreme, local fractionation of tissue within the focal region. Here, we demonstrate the feasibility of a recently developed approach to HIFU-induced ultrasound-guided tissue fractionation in an in vivo pig model. In this approach, termed boiling histotripsy, a millimeter-sized boiling bubble is generated by ultrasound and further interacts with the ultrasound field to fractionate porcine liver tissue into subcellular debris without inducing further thermal effects. Tissue selectivity, demonstrated by boiling histotripsy, allows for the treatment of tissue immediately adjacent to major blood vessels and other connective tissue structures. Furthermore, boiling histotripsy would benefit the clinical applications, in which it is important to accelerate resorption or passage of the ablated tissue volume, diminish pressure on the surrounding organs that causes discomfort, or insert openings between tissues.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Fígado/cirurgia , Frações Subcelulares/diagnóstico por imagem , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/métodos , Animais , Eritrócitos/citologia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Fígado/irrigação sanguínea , Fígado/citologia , Circulação Hepática , Pulmão/citologia , Pulmão/cirurgia , Modelos Animais , Sus scrofa , Transdutores , Terapia por Ultrassom/efeitos adversos , Ultrassonografia
2.
J Acoust Soc Am ; 138(4): 2181-205, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520301

RESUMO

Sonoluminescence is the production of electromagnetic radiation, much of it in the form of visible light, that is emitted from a gas-filled cavity that has grown and collapsed under the influence of a varying pressure field. This resource paper provides a guide to the literature of sonoluminescence, from its early history to the present.

3.
J Acoust Soc Am ; 130(5): 3511-30, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088026

RESUMO

Cavitation often occurs in therapeutic applications of medical ultrasound such as shock-wave lithotripsy (SWL) and high-intensity focused ultrasound (HIFU). Because cavitation bubbles can affect an intended treatment, it is important to understand the dynamics of bubbles in this context. The relevant context includes very high acoustic pressures and frequencies as well as elevated temperatures. Relative to much of the prior research on cavitation and bubble dynamics, such conditions are unique. To address the relevant physics, a reduced-order model of a single, spherical bubble is proposed that incorporates phase change at the liquid-gas interface as well as heat and mass transport in both phases. Based on the energy lost during the inertial collapse and rebound of a millimeter-sized bubble, experimental observations were used to tune and test model predictions. In addition, benchmarks from the published literature were used to assess various aspects of model performance. Benchmark comparisons demonstrate that the model captures the basic physics of phase change and diffusive transport, while it is quantitatively sensitive to specific model assumptions and implementation details. Given its performance and numerical stability, the model can be used to explore bubble behaviors across a broad parameter space relevant to therapeutic ultrasound.


Assuntos
Modelos Teóricos , Terapia por Ultrassom , Ultrassom , Simulação por Computador , Difusão , Transferência de Energia , Gases , Movimento (Física) , Análise Numérica Assistida por Computador , Pressão , Reprodutibilidade dos Testes , Som , Propriedades de Superfície , Temperatura , Fatores de Tempo , Volatilização
4.
J Acoust Soc Am ; 130(5): 3531-40, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088027

RESUMO

Bubbles excited by lithotripter shock waves undergo a prolonged growth followed by an inertial collapse and rebounds. In addition to the relevance for clinical lithotripsy treatments, such bubbles can be used to study the mechanics of inertial collapses. In particular, both phase change and diffusion among vapor and noncondensable gas molecules inside the bubble are known to alter the collapse dynamics of individual bubbles. Accordingly, the role of heat and mass transport during inertial collapses is explored by experimentally observing the collapses and rebounds of lithotripsy bubbles for water temperatures ranging from 20 to 60 °C and dissolved gas concentrations from 10 to 85% of saturation. Bubble responses were characterized through high-speed photography and acoustic measurements that identified the timing of individual bubble collapses. Maximum bubble diameters before and after collapse were estimated and the corresponding ratio of volumes was used to estimate the fraction of energy retained by the bubble through collapse. The rebounds demonstrated statistically significant dependencies on both dissolved gas concentration and temperature. In many observations, liquid jets indicating asymmetric bubble collapses were visible. Bubble rebounds were sensitive to these asymmetries primarily for water conditions corresponding to the most dissipative collapses.


Assuntos
Litotripsia , Difusão , Gases , Modelos Estatísticos , Movimento (Física) , Tamanho da Partícula , Fotografação , Pressão , Processamento de Sinais Assistido por Computador , Temperatura , Fatores de Tempo , Volatilização
5.
J Acoust Soc Am ; 130(5): 3498-510, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22088025

RESUMO

In high intensity focused ultrasound (HIFU) applications, tissue may be thermally necrosed by heating, emulsified by cavitation, or, as was recently discovered, emulsified using repetitive millisecond boiling caused by shock wave heating. Here, this last approach was further investigated. Experiments were performed in transparent gels and ex vivo bovine heart tissue using 1, 2, and 3 MHz focused transducers and different pulsing schemes in which the pressure, duty factor, and pulse duration were varied. A previously developed derating procedure to determine in situ shock amplitudes and the time-to-boil was refined. Treatments were monitored using B-mode ultrasound. Both inertial cavitation and boiling were observed during exposures, but emulsification occurred only when shocks and boiling were present. Emulsified lesions without thermal denaturation were produced with shock amplitudes sufficient to induce boiling in less than 20 ms, duty factors of less than 0.02, and pulse lengths shorter than 30 ms. Higher duty factors or longer pulses produced varying degrees of thermal denaturation combined with mechanical emulsification. Larger lesions were obtained using lower ultrasound frequencies. The results show that shock wave heating and millisecond boiling is an effective and reliable way to emulsify tissue while monitoring the treatment with ultrasound.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Temperatura Alta , Fígado/cirurgia , Miocárdio/patologia , Animais , Bovinos , Ecocardiografia , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Fígado/diagnóstico por imagem , Fígado/patologia , Necrose , Imagens de Fantasmas , Pressão , Fatores de Tempo , Transdutores de Pressão
6.
Urol Res ; 38(6): 491-5, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20967437

RESUMO

The success of surgical management of lower pole stones is principally dependent on stone fragmentation and residual stone clearance. Choice of surgical method depends on stone size, yet all methods are subjected to post-surgical complications resulting from residual stone fragments. Here we present a novel method and device to reposition kidney stones using ultrasound radiation force delivered by focused ultrasound and guided by ultrasound imaging. The device couples a commercial imaging array with a focused annular array transducer. Feasibility of repositioning stones was investigated by implanting artificial and human stones into a kidney-mimicking phantom that simulated a lower pole and collecting system. During experiment, stones were located by ultrasound imaging and repositioned by delivering short bursts of focused ultrasound. Stone motion was concurrently monitored by fluoroscopy, ultrasound imaging, and video photography, from which displacement and velocity were estimated. Stones were seen to move immediately after delivering focused ultrasound and successfully repositioned from the lower pole to the collecting system. Estimated velocities were on the order of 1 cm/s. This in vitro study demonstrates a promising modality to facilitate spontaneous clearance of kidney stones and increased clearance of residual stone fragments after surgical management.


Assuntos
Cálculos Renais/diagnóstico por imagem , Fluoroscopia , Humanos , Cálculos Renais/cirurgia , Ultrassonografia
7.
J Acoust Soc Am ; 128(1): 104-20, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20649206

RESUMO

Accurate monitoring of high intensity focused ultrasound (HIFU) therapy is critical for widespread clinical use. Pulse-echo diagnostic ultrasound (DU) is known to exhibit temperature sensitivity through relative changes in time-of-flight between two sets of radio frequency (RF) backscatter measurements, one acquired before and one after therapy. These relative displacements, combined with knowledge of the exposure protocol, material properties, heat transfer, and measurement noise statistics, provide a natural framework for estimating the administered heating, and thereby therapy. The proposed method, termed displacement analysis, identifies the relative displacements using linearly independent displacement patterns, or modes, each induced by a particular time-varying heating applied during the exposure interval. These heating modes are themselves linearly independent. This relationship implies that a linear combination of displacement modes aligning the DU measurements is the response to an identical linear combination of heating modes, providing the heating estimate. Furthermore, the accuracy of coefficient estimates in this approximation is determined a priori, characterizing heating, thermal dose, and temperature estimates for any given protocol. Predicted performance is validated using simulations and experiments in alginate gel phantoms. Evidence for a spatially distributed interaction between temperature and time-of-flight changes is presented.


Assuntos
Ondas de Choque de Alta Energia , Ablação por Ultrassom Focalizado de Alta Intensidade , Modelos Lineares , Espalhamento de Radiação , Ultrassonografia , Alginatos/química , Simulação por Computador , Géis , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Temperatura , Condutividade Térmica , Fatores de Tempo , Transdutores , Ultrassonografia/instrumentação
8.
J Acoust Soc Am ; 127(6): 3456-65, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20550245

RESUMO

It is well known that cavitation collapse can generate intense concentrations of mechanical energy, sufficient to erode even the hardest metals and to generate light emissions visible to the naked eye [sonoluminescence (SL)]. Considerable attention has been devoted to the phenomenon of "single bubble sonoluminescence" (SBSL) in which a single stable cavitation bubble radiates light flashes each and every acoustic cycle. Most of these studies involve acoustic resonators in which the ambient pressure is near 0.1 MPa (1 bar), and with acoustic driving pressures on the order of 0.1 MPa. This study describes a high-quality factor, spherical resonator capable of achieving acoustic cavitation at ambient pressures in excess of 30 MPa (300 bars). This system generates bursts of violent inertial cavitation events lasting only a few milliseconds (hundreds of acoustic cycles), in contrast with the repetitive cavitation events (lasting several minutes) observed in SBSL; accordingly, these events are described as "inertial transient cavitation." Cavitation observed in this high pressure resonator is characterized by flashes of light with intensities up to 1000 times brighter than SBSL flashes, as well as spherical shock waves with amplitudes exceeding 30 MPa at the resonator wall. Both SL and shock amplitudes increase with static pressure.

9.
J Acoust Soc Am ; 125(4): 2420-31, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19354416

RESUMO

Both mechanically induced acoustic cavitation and thermally induced boiling can occur during high intensity focused ultrasound (HIFU) medical therapy. The goal was to monitor the temperature as boiling was approached using magnetic resonance imaging (MRI). Tissue phantoms were heated for 20 s in a 4.7-T magnet using a 2-MHz HIFU source with an aperture and radius of curvature of 44 mm. The peak focal pressure was 27.5 MPa with corresponding beam width of 0.5 mm. The temperature measured in a single MRI voxel by water proton resonance frequency shift attained a maximum value of only 73 degrees C after 7 s of continuous HIFU exposure when boiling started. Boiling was detected by visual observation, by appearance on the MR images, and by a marked change in the HIFU source power. Nonlinear modeling of the acoustic field combined with a heat transfer equation predicted 100 degrees C after 7 s of exposure. Averaging of the calculated temperature field over the volume of the MRI voxel (0.3 x 0.5 x 2 mm(3)) yielded a maximum of 73 degrees C that agreed with the MR thermometry measurement. These results have implications for the use of MRI-determined temperature values to guide treatments with clinical HIFU systems.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Modelos Teóricos , Dinâmica não Linear , Imagens de Fantasmas , Temperatura , Fatores de Tempo , Ultrassonografia/métodos
10.
J Acoust Soc Am ; 124(4): 2406-20, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19062878

RESUMO

Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24,000 W/cm(2). The inputs to a Khokhlov-Zabolotskaya-Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W/cm(2), lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields.


Assuntos
Acústica , Modelos Biológicos , Terapia por Ultrassom , Acústica/instrumentação , Animais , Calibragem , Simulação por Computador , Géis , Humanos , Dinâmica não Linear , Análise Numérica Assistida por Computador , Fibras Ópticas , Imagens de Fantasmas , Pressão , Fatores de Tempo , Transdutores/normas , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/normas , Vibração , Água
11.
Phys Med Biol ; 52(19): 5933-44, 2007 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-17881810

RESUMO

This study evaluated the cavitation activity induced by shock wave (SW) pulses, both in vitro and in vivo, based on the area measurements of echogenic regions observed in B-mode ultrasound images. Residual cavitation bubble clouds induced by SW pulses were detected as echogenic regions in B-mode images. The temporal evolution of residual bubble clouds, generated by SWs with varying lithotripter charging voltage and pulse repetition frequency (PRF), was analyzed by measuring the time-varying behaviors of the echogenic region areas recorded in B-mode images. The results showed that (1) the area of SW-induced echogenic regions enlarged with increased SW pulse number; (2) echogenic regions in the B-mode images dissipated gradually after ceasing the SWs, which indicated the dissolution of the cavitation bubbles; and (3) larger echogenic regions were generated with higher charging voltage or PRF.


Assuntos
Ondas de Choque de Alta Energia/uso terapêutico , Litotripsia/métodos , Modelos Biológicos , Radiometria/métodos , Terapia por Ultrassom/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Doses de Radiação , Eficiência Biológica Relativa
12.
Theranostics ; 7(19): 4894-4908, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29187912

RESUMO

Microbubble-mediated sonoporation has shown its great potential in facilitating intracellular uptake of gene/drugs and other therapeutic agents that are otherwise difficult to enter cells. However, the biophysical mechanisms underlying microbubble-cell interactions remain unclear. Particularly, it is still a major challenge to get a comprehensive understanding of the impact of cell cycle phase on the cellular responses simultaneously occurring in cell membrane and cytoskeleton induced by microbubble sonoporation. Methods: Here, efficient synchronizations were performed to arrest human cervical epithelial carcinoma (HeLa) cells in individual cycle phases. The, topography and stiffness of synchronized cells were examined using atomic force microscopy. The variations in cell membrane permeabilization and cytoskeleton arrangement induced by sonoporation were analyzed simultaneously by a real-time fluorescence imaging system. Results: The results showed that G1-phase cells typically had the largest height and elastic modulus, while S-phase cells were generally the flattest and softest ones. Consequently, the S-Phase was found to be the preferred cycle for instantaneous sonoporation treatment, due to the greatest enhancement of membrane permeability and the fastest cytoskeleton disassembly at the early stage after sonoporation. Conclusion: The current findings may benefit ongoing efforts aiming to pursue rational utilization of microbubble-mediated sonoporation in cell cycle-targeted gene/drug delivery for cancer therapy.


Assuntos
Ciclo Celular/efeitos da radiação , Membrana Celular/efeitos da radiação , Ondas Ultrassônicas , Membrana Celular/metabolismo , Permeabilidade da Membrana Celular/efeitos da radiação , Citoesqueleto/metabolismo , Citoesqueleto/efeitos da radiação , Células HeLa , Humanos , Microbolhas , Ultrassom/instrumentação , Ultrassom/métodos
13.
Ultrasound Med Biol ; 32(11): 1721-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17112958

RESUMO

Guidance and monitoring of high intensity focused ultrasound (HIFU) therapy, using ultrasound imaging, has primarily utilized formation of a hyperechoic region at the HIFU focus. We investigated biologic and physical mechanisms of a hyperecho, as well as safety of this phenomenon, using thermal, acoustic and light microscopy observations. Single, short-duration HIFU pulses (30-60 ms) were able to produce a hyperechoic region at the HIFU focus, 2 cm deep in a rabbit thigh muscle. When hyperechoic regions appeared, inertial cavitation was detected in vivo using a custom-made passive cavitation detection system. Light micrographs showed a large number of cavities (approximately 100/mm3), 1-10 microm in diameter, in a cytoplasm of cells located at the HIFU focus. Blood congestion was observed around a focal region, indicating an injury of microvasculature. Cellular necrosis was observed at 2 d after the treatment, while healing, scar tissue formation and regeneration were observed at 7 d and 14 d. The results indicate that a possibility of adverse tissue effects has to be taken into consideration when the hyperecho formation, induced by very-short HIFU pulses, is used for pretreatment targeting.


Assuntos
Músculo Esquelético/diagnóstico por imagem , Terapia por Ultrassom/métodos , Acústica , Animais , Microbolhas , Músculo Esquelético/patologia , Necrose/etiologia , Coelhos , Suínos , Temperatura , Terapia por Ultrassom/efeitos adversos , Ultrassonografia , Cicatrização
14.
Ultrasound Med Biol ; 32(2): 281-8, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16464673

RESUMO

Previous in vitro studies have shown that ultrasound-induced mechanical bioeffects with contrast agents present are highly correlated with inertial cavitation (IC) "dose" (Chen et al. 2003a, 2003c). The ex vivo experiments conducted here addressed the following hypotheses: 1. IC activity can be generated by insonating perfused rabbit ear blood vessel, and 2. the IC "dose" developed during insonation treatment can be reliably measured and will vary with varying acoustic parameters and Optison concentration. Ex vivo rabbit auricular arteries were perfused with Optison suspensions and then exposed to 1.1-MHz pulsed focused ultrasound. Experimental variables included peak negative acoustic pressure (0.2 MPa to 5.2 MPa), pulse-repetition frequency (5, 50 or 500 Hz), pulse length (50, 100, 500 or 1000 cycles), and Optison volume concentration (0, 0.2, 0.5 or 1%). Cavitation activity was quantified as IC dose, based on passive cavitation detection measurements. The results show that: 1. The IC pressure threshold decreases with higher concentrations of Optison, and 2. IC dose increases significantly with increasing acoustic pressure, Optison concentration, pulse length or with decreasing pulse-repetition frequency.


Assuntos
Albuminas , Meios de Contraste , Orelha/irrigação sanguínea , Fluorocarbonos , Ultrassom , Animais , Artérias , Relação Dose-Resposta a Droga , Microbolhas , Perfusão , Pressão , Pulso Arterial , Coelhos
15.
Ultrasound Med Biol ; 32(11): 1731-41, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17112959

RESUMO

Study of coagulative lesion formation by high intensity focused ultrasound (HIFU) in tissue usually requires performing a sequence of experiments under different exposure conditions followed by tissue sectioning. This paper, inspired by the pioneering work of Frederic L. Lizzi, reports on the use of the bovine eye lens as a laboratory model to observe visually the development of HIFU-induced lesions. The first part of this work describes the measurement of the lens shape, density, sound speed and attenuation. The measured values were within the range of previously published values. In the second part, HIFU-induced lesion development was observed in real-time and compared with good agreement with theoretical simulation. Theoretical modeling included acoustic propagation, absorptive heating and thermal dose, as well as the experimentally measured lens characteristics. Thus, the transparent eye lens can be used as a laboratory phantom to facilitate the understanding of HIFU treatment in other tissues.


Assuntos
Cristalino/diagnóstico por imagem , Imagens de Fantasmas , Terapia por Ultrassom/métodos , Acústica , Animais , Bovinos , Cristalino/patologia , Cristalino/fisiopatologia , Necrose , Pressão , Temperatura , Ultrassonografia
16.
Ultrasound Med Biol ; 32(10): 1601-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17045881

RESUMO

Inertial cavitation (IC) is an important mechanism by which ultrasound (US)-induced bioeffects can be produced. It has been reported that US-induced in vitro mechanical bioeffects with the presence of ultrasound contrast agents (UCAs) are highly correlated with quantified IC "dose" (ICD: cumulated root-mean-squared broadband noise amplitude in the frequency domain). The ICD has also been used to quantify IC activity in ex vivo perfused rabbit ear vessels. The in vivo experiments reported here using a rabbit ear vessel model were designed to: (1) detect and quantify IC activity in vivo within the constrained environment of rabbit auricular veins with the presence of Optison and (2) measure the temporal evolution of microbubble IC activity and the ICD generated during insonation treatment, as a function of acoustic parameters. Preselected regions-of-interest (ROI) in the rabbit ear vein were exposed to pulsed focused US (1.17 MHz, 1 Hz PRF). Experimental acoustic variables included peak rarefaction pressure amplitude ([PRPA]: 1.1, 3.0, 6.5 or 9.0 MPa) and pulse length (20, 100, 500 or 1000 cycles). ICD was quantified based on passive cavitation detection (PCD) measurements. The results show that: (1) after Optison injection, the time to onset of measurable microbubble IC activity was relatively consistent, approximately 20 s; (2) after reaching its peak value, the IC activity decayed exponentially and the half-life decay coefficient (t(1/2)) increased with increasing PRPA and pulse length; and (3) the normalized ICD generated by pulsed US exposure increased significantly with increasing PRPA and pulse length.


Assuntos
Albuminas/administração & dosagem , Orelha/irrigação sanguínea , Fluorocarbonos/administração & dosagem , Ultrassom , Animais , Meios de Contraste , Meia-Vida , Injeções , Microbolhas , Microesferas , Modelos Animais , Coelhos , Fatores de Tempo , Veias
17.
Ultrasound Med Biol ; 32(10): 1611-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17045882

RESUMO

Previous in vivo studies have demonstrated that vascular endothelial damage can result when vessels containing gas-based microbubble ultrasound contrast agent (UCA) are exposed to MHz-frequency pulsed ultrasound (US) of sufficient pressure amplitudes, presumably as a result of inertial cavitation (IC). The hypothesis guiding this research was that IC is the primary mechanism by which the vascular endothelium (VE) is damaged when a vessel is exposed to pulsed 1-MHz frequency US in the presence of circulating UCA. The expectation was that a correlation should exist between the magnitude and duration of IC activity and the degree of VE damage. Rabbit auricular vessels were exposed in vivo to 1.17-MHz focused US of variable peak rarefaction pressure amplitude (1, 3, 6.5 or 9 MPa), using low duty factors (0.04% or 0.4%), pulse lengths of 500 or 5000 cycles, with varying treatment durations and with or without infusion of a shelled microbubble contrast agent. A broadband passive cavitation detection system was used to measure IC activity in vivo within the targeted segment of the blood vessel. The magnitude of the detected IC activity was quantified using a previously reported measure of IC dose. Endothelial damage was assessed via scanning electron microscopy image analysis. The results supported the hypothesis and demonstrate that the magnitude of the measured IC dose correlates with the degree of VE damage when UCA is present. These results have implications for therapeutic US-induced vascular occlusion.


Assuntos
Células Endoteliais/patologia , Endotélio Vascular/patologia , Ultrassom , Albuminas/administração & dosagem , Animais , Meios de Contraste , Orelha/irrigação sanguínea , Orelha/patologia , Fluorocarbonos/administração & dosagem , Hemorragia/patologia , Microbolhas , Microscopia Eletrônica/métodos , Microscopia Eletrônica de Varredura/métodos , Microesferas , Modelos Animais , Adesividade Plaquetária/fisiologia , Coelhos , Veias/ultraestrutura
18.
Artigo em Inglês | MEDLINE | ID: mdl-16555774

RESUMO

Ultrasound imaging is useful for monitoring high-intensity, focused ultrasound (HIFU) therapy; however, interference on the ultrasound image, caused by HIFU excitation, must be avoided. A method to synchronize HIFU excitation with ultrasound imaging is described here. Synchronization was tested with two unmodified, commercial imagers and two tissue phantoms.

19.
Ultrasonics ; 44(1): 46-53, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16176829

RESUMO

High-intensity focused ultrasound (HIFU) has been shown to provide an effective method for hemorrhage control of blood vessels in acute animal studies. The objective of the current study was to investigate the long-term effects of HIFU-induced hemostasis in punctured arteries. The femoral arteries ( approximately 2mm in diameter) of 25 adult anesthetized rabbits were surgically exposed, and either punctured and treated with HIFU (n=15), served as control (no puncture and no HIFU application: n=7), or were punctured and left untreated (n=3). Treated animals were allowed to recover, and examined and/or sacrificed on days 0, 1, 3, 7, 14, 28, and 60 after treatment to obtain ultrasound images and samples of blood and tissue. Hemostasis (arrest of bleeding) was achieved in all 15 of the HIFU-treated arteries. Eleven of the arteries were patent after HIFU treatment, and four arteries were occluded, as determined by Doppler ultrasound. The median HIFU application time to achieve hemostasis was 20s (range 7-55 s) for the patent arteries and 110 s (range 50-134 s) for the occluded arteries. In untreated animals, bleeding had not stopped after 120 s. One of the occluded arteries had reopened by day 14. No immediate or delayed re-bleeding was observed after HIFU treatment. Maximal blood flow velocities were similar in HIFU-treated patent vessels and control vessels. No significant difference in hematocrits was found between HIFU-treated and control groups at different time points after the procedure. Light microscopy observations of the HIFU-treated arteries showed disorganization of adventitia, and coagulation and thinning of the tunica media. The general organization of the adventitia and tunica media recovered to normal appearance within 28 days, with some thinning of the tunica media observed up to day 60. Neointimal hyperplasia was observed on days 14 and 28. The results show that HIFU can produce effective and long-term (up to 60 days) hemostasis of punctured femoral arteries while preserving normal blood flow and vessel wall structure in the majority of vessels.


Assuntos
Hemorragia/prevenção & controle , Técnicas Hemostáticas , Terapia por Ultrassom/métodos , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Tecido Elástico/patologia , Artéria Femoral/lesões , Artéria Femoral/patologia , Hematócrito , Hiperplasia , Punções , Coelhos , Recidiva , Trombose/etiologia , Trombose/patologia , Fatores de Tempo , Túnica Íntima/patologia , Túnica Média/patologia , Grau de Desobstrução Vascular/fisiologia
20.
Hum Gene Ther ; 16(7): 893-905, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16000070

RESUMO

Delivery of plasmid DNA can be enhanced by treatment with ultrasound (US); acoustic cavitation appears to play an important role in the process. Ultrasound contrast agents (UCAs; stabilized microbubbles) nucleate acoustic cavitation, and lower the acoustic pressure threshold for inertial cavitation occurrence. Fifty micrograms of a liver-specific, high-expressing human factor IX plasmid, pBS-HCRHP-FIXIA, mixed with UCA or phosphate-buffered saline was delivered to mouse livers by intrahepatic injection, with simultaneous exposure to 1 MHz-pulsed US using various acoustic protocols. Variable pulse duration (PD) at constant treatment time, pulse repetition frequency, and an acoustic peak negative pressure amplitude of 1.8 MPa produced 2- to 13-fold enhancements in hFIX gene expression, but PD was not a strong determinant. In contrast, a dose-response relationship was demonstrated for the peak negative pressure (P-), with significant enhancement of gene transduction at P- >/= 2 MPa. Up to 63 ng/ml (approaching the therapeutic range for treating hemophilia patients) could be achieved by transducing one liver lobe at 4-MPa P-, corresponding to a 66- fold increment relative to treatment with naked DNA alone. Under the same conditions, mouse livers could also be transduced with a GFP plasmid. Histology showed transient liver damage caused by intrahepatic injection and US exposure at 4-MPa P-; however, the damage was repaired in a few days. We conclude that therapeutic US in combination with UCA has the potential to promote safe and efficient nonviral gene transfer of hFIX for the treatment of hemophilia.


Assuntos
Fator IX/genética , Técnicas de Transferência de Genes , Ultrassom , Alanina Transaminase/metabolismo , Animais , Aspartato Aminotransferases/metabolismo , Fator IX/metabolismo , Expressão Gênica , Terapia Genética , Proteínas de Fluorescência Verde/análise , Proteínas de Fluorescência Verde/genética , Hemofilia A/genética , Hemofilia A/terapia , Fígado/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Microbolhas , Plasmídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA