Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Thorac Cardiovasc Surg ; 69(1): 34-42, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-30873579

RESUMO

INTRODUCTION: Mitochondrial DNA (mtDNA) is gaining increasing interest as a marker of cellular damage and could also act as an inflammatory mediator in cardiopulmonary bypass induced postoperative inflammatory response. Although minimally invasive heart valve surgery reportedly reduces inflammation, the mtDNA and cytokine profile in this context remains unclear. MATERIALS AND METHODS: Here, we report a prospective series of 40 elderly patients with aortic stenosis who underwent bioprosthetic aortic valve replacement (AVR) through upper ministernotomy with either a sutureless (n = 20) or a conventional (n = 20) valve. Primary end points included serial plasma levels of mtDNA (T1: at baseline; T2: 4 hours after surgery; and T3: 24s hour after surgery), cytokines (interleukin-6 [IL-6], tumor necrosis factor-α [TNF-α]), and myocardial necrosis biomarkers (MNBs), whereas secondary end points included clinical and echocardiographic data. RESULTS: Significant increases in the postoperative plasma levels (T2) of mtDNA, cytokines, and MNBs were observed in all patients. The postoperative plasma levels of mtDNA, TNF-α, and MNBs showed no significant differences between the treatment groups, although there was a trend toward lower levels in the sutureless group. The decreases in aortic cross-clamp and cardiopulmonary bypass times seen in the sutureless group were associated with significant lower postoperative levels (T2 and T3) of IL-6. CONCLUSION: AVR through upper ministernotomy was associated with a significant increase in postoperative plasma levels of mtDNA and cytokines. There was no difference in the mtDNA levels between the sutureless and conventional valve groups, suggesting a similar level of inflammation in both groups. However, the shorter operation time observed in the sutureless valve group was associated with significantly lower postoperative levels of IL-6, indicating potential clinical benefits.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ácidos Nucleicos Livres/sangue , Citocinas/sangue , DNA Mitocondrial/sangue , Implante de Prótese de Valva Cardíaca , Mediadores da Inflamação/sangue , Fatores Etários , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/diagnóstico , Biomarcadores/sangue , Bioprótese , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Duração da Cirurgia , Estudos Prospectivos , Índice de Gravidade de Doença , Esternotomia , Procedimentos Cirúrgicos sem Sutura , Fatores de Tempo , Resultado do Tratamento
2.
J Card Surg ; 33(7): 356-362, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29790206

RESUMO

OBJECTIVES: Bioprostheses with pericardial leaflets mounted externally on the stent pose a high risk for valve-in-valve (ViV) procedures. This study analyzed the efficacy and safety of ViV procedures for treating structural valve deterioration (SVD) in Mitroflow bioprostheses. METHODS: Between January 2012 and August 2017, 11 patients (mean age 80.3 ± 5.6 years) were treated for SVD of Mitroflow bioprostheses with transcatheter ViV procedures (six transapical [TA] and five transfemoral [TF]) using balloon expandable bioprostheses. RESULTS: All patients but one were in NYHA class III-IV. Mean STS PROM, euroSCORE I, and euroSCORE II were 8 ± 6.5%, 27.8 ± 11.5%, and 12 ± 5.9%, respectively. Two patients had a "porcelain aorta." The size of implanted valves were 23 mm in 10 cases and 26 mm in one case. One patient suffered a coronary occlusion during a TF approach. The mean volume of contrast used in TF implants was 163 ± 69.8 mL. No contrast media were used in TA procedures. There was one in-hospital death (10%). At 1 year of follow-up, peak and mean aortic gradients were 25.5 ± 5.8 mmHg and 15.5 ± 5.7 mmHg, respectively. One patient had mild paravalvular regurgitation. Cumulative survival was 90.9% at 1 year, 70.7% at 2 years, and 53% at 3 years. CONCLUSIONS: ViV procedures with balloon-expandable aortic valves provide good hemodynamic and clinical mid-term results for treating patients with a degenerated Mitroflow aortic bioprosthesis. Special care must be taken in small aortic roots, when the stented valve is in the supra-annular position to avoid coronary ostial obstruction.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Segurança , Stents , Resultado do Tratamento
3.
J Card Surg ; 31(5): 264-73, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26991888

RESUMO

BACKGROUND: This study aims to determine the incidence and causes of structural valve deterioration (SVD) among all models of Mitroflow bioprostheses (A12/LX/DL), as well as to define their long-term clinical and hemodynamic performance. METHODS AND RESULTS: We retrospectively reviewed a series of 1023 patients who underwent aortic valve replacement with Mitroflow bioprostheses between 2001 and 2014. A small aortic root was found in 22.4% of patients. There were two cases of severe patient-prosthesis mismatch. Only 31 patients developed SVD. The rate of incidence was 8.1 cases per 1000 patient-years. Cumulative incidence of SVD was 1.4% and 3% at five and 10 years, respectively. Freedom from SVD was 97.4% and 88.2% at five and 10 years, respectively. Anticalcification phospholipid reduction treatment (PRT) for model DL was a protective factor for SVD. Multivariable analysis confirmed age <70 years and use of 19 mm valve as independent predictors of SVD. Cumulative survival was 76.6% at five years and 42.3% at 10 years (mean follow-up 3.8 ± 3.1 years). In multivariable analysis, neither the use of small aortic prosthesis (p = 0.18) nor the occurrence of SVD (p = 0.85) was found to be independent predictors of long-term survival. CONCLUSIONS: Mitroflow valves demonstrate an acceptable rate of SVD and satisfactory long-term hemodynamic performance, particularly in patients with small aortic roots, age >70 years, and cases with severe left ventricular hypertrophy. PRT might contribute to improved long-term durability. doi: 10.1111/jocs.12726 (J Card Surg 2016;31:264-273).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Teste de Materiais , Complicações Pós-Operatórias/epidemiologia , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Espanha/epidemiologia , Fatores de Tempo
4.
JTCVS Tech ; 22: 150-158, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152173

RESUMO

Objectives: This study analyzes neocommissural alignment and the clinical and hemodynamic outcomes after transaxillary and transcarotid implantation of the Acurate neo2 transcatheter heart valve. Methods: We performed a retrospective, single-center analysis of early outcomes after transaxillary and transcarotid implantation of the Acurate neo2 transcatheter heart valve. Primary outcomes were neocommisural alignment, in-hospital mortality, and valve hemodynamic performance. Commissural alignment between native and transcatheter heart valves was assessed by transesophageal echocardiogram before and after the procedure. Results: Between October 2021 and November 2022, 40 consecutive patients were treated with the Acurate neo2 through a transaxillary or transcarotid approach. Access was achieved via the left subclavian artery in 30 cases and the left common carotid artery in 10 cases, with a mean vessel diameter of 6.7 mm. Implants most commonly used were size M (37.5%), L (35%), and S (27.5%). On the basis of transesophageal echocardiogram analysis, there was no significant difference in mean commissural orientation between native (mean, 65.1°; SD, 41.3°) and neocommissures (mean, 64°; SD, 44.1°) (P = .661). Mean commissural orientation did not significantly differ between native and neocommissures (P = .661). Optimal alignment or mild commissural misalignment was achieved in 99.5% of cases. There were no cases of severe commissural misalignment. Postprocedural mean values for peak and mean gradients were 12.7 mm Hg and 5.2 mm Hg, respectively. There were 2 cases of moderate paravalvular leak and 4 cases of mild paravalvular leak. Conclusions: This patient-specific technique for transaxillary and transcarotid insertion of the Acurate neo2 delivery system prevents implantations with more than mild commissural misalignment and with a high device success rate.

5.
Interact Cardiovasc Thorac Surg ; 33(2): 195-202, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-33792711

RESUMO

OBJECTIVES: This study aims to evaluate the efficacy, safety and long-term outcomes of a renoprotective non-contrast, transoesophageal echocardiography-guided transapical (TA) transcatheter aortic valve replacement (TAVR) strategy with a balloon-expandable prosthesis, as well as to determine its impact on renal function. METHODS: Between 2009 and 2019, 200 consecutive patients underwent a non-contrast, transoesophageal echocardiography-guided TA TAVR with a balloon-expandable prosthesis. RESULTS: The device success rate was 95.5%. Transoesophageal echocardiography-guided deployment demonstrated a low rate of procedure-related complications: 9.5% of acute kidney injury, 8% postoperative bleeding, 6% low-cardiac output, 4.5% postprocedural aortic regurgitation ≥+2, 4% implantation of permanent pacemaker and 2% stroke. There were no significant differences between preoperative and on discharge estimated glomerular filtration rate (53.9 ± 22.2 vs 54.3 ± 22.9 ml/min/1.73 m2, P = 0.60). Logistic regression analysis confirmed postoperative bleeding as an independent predictor for acute kidney injury (odds ratio (OR) 11.148, 95% confidence interval 3.537-35.140, P < 0.001). In-hospital mortality was 7.5%. The mean follow-up was 48.5 ± 39.9 months. Renal function and patient's chronic kidney disease stage did not significantly vary during follow-up. Long-term cumulative survival at 1, 5 and 10 years was 84.2 ± 0.027%, 42.9 ± 0.038% and 32.5 ± 0.044%, respectively. Renal function affected on neither in-hospital mortality nor long-term survival. CONCLUSIONS: Non-contrast, transoesophageal echocardiography-guided TA TAVR is a safe and reproducible technique with a low incidence of periprocedural complications that avoids the use of contrast and mitigates the incidence of acute kidney injury.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Semin Thorac Cardiovasc Surg ; 31(4): 828-834, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31005576

RESUMO

Deleterious long-term effects of chronic pulmonary regurgitation after repair of tetralogy of Fallot have become evident during the last decades. Subsequently, some groups have developed strategies to spare the pulmonary valve function at the time of repair with good early results. However, mid-term outcomes are scarce in the literature and in some cases controversial. The aim of our study is to report our results mid-term with valve-sparing repair of tetralogy of Fallot. We retrospectively reviewed patients undergoing tetralogy of Fallot repair and having preservation of the pulmonary valve with intraoperative dilation at our institution. From June 2009 through June 2017, 42 patients underwent valve-sparing tetralogy of Fallot repair. Median age and weight at surgery were 5.2 months and 7.2 kg. Median preoperative pulmonary valve diameters and Z scores by echocardiography were 6.4 mm (range 4.5-11 mm) and -2.3 (range -1.3 to -4.5). No patient died in our series. For a median follow-up of 45 months, the pulmonary valve has grown by Z score (P < 0.0001) as well as the pulmonary trunk (P= 0.00216). Significant pulmonary regurgitation has developed in 9 patients (21.4%). No patient has required reintervention/reoperation for recurrent right ventricular outflow tract obstruction. Patients with tetralogy of Fallot who had valve-sparing repair with intraoperative dilation of the pulmonary valve show good early and mid-term results with respect to right ventricular outflow tract obstruction. The pulmonary valve annulus and the pulmonary trunk grow through follow-up. Progressive development of significant pulmonary regurgitation is seen in more than 20% of patients. Long-term data with this approach and comparison with a population of patients undergoing a transannular patch repair are required to establish the real utility of this approach.


Assuntos
Valvuloplastia com Balão , Procedimentos Cirúrgicos Cardíacos , Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/cirurgia , Valvuloplastia com Balão/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia , Feminino , Humanos , Lactente , Masculino , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
7.
Asian Cardiovasc Thorac Ann ; 27(1): 5-10, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30409026

RESUMO

AIM: The underlying pathophysiologic mechanisms of aortic stenosis are not clear. Mitochondrial dysfunction plays a role in many pathological conditions including cardiac diseases. We aimed to analyze the mitochondrial DNA haplogroups in a group of patients undergoing valve replacement surgery due to severe aortic stenosis. METHODS: Mitochondrial DNA haplogroups were assessed in 176 patients with severe aortic stenosis and 308 control subjects. Cardiovascular risk factors and demographics were similar in both groups. RESULTS: Patients carrying haplogroup Uk had a lower risk of developing aortic stenosis, especially compared to patients carrying haplogroup H (odds ratio = 0.507; 95% confidence interval: 0.270-0.952, p = 0.035). CONCLUSIONS: Mitochondrial DNA haplogroups could be involved in the development of severe aortic stenosis. Specifically, haplogroup H could be a risk factor and Uk a protective factor for severe aortic stenosis in a population from Spain.


Assuntos
Estenose da Valva Aórtica/genética , DNA Mitocondrial/genética , Haplótipos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estudos de Casos e Controles , Feminino , Estudos de Associação Genética , Predisposição Genética para Doença , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Espanha
8.
Rev Esp Cardiol (Engl Ed) ; 72(11): 899-906, 2019 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30477951

RESUMO

INTRODUCTION AND OBJECTIVES: Circulating galectin-3 (Gal-3) is elevated and significantly correlates with all-cause and cardiovascular mortality in patients with heart failure. However, the relationship between serum Gal-3 and heart transplant (HT) outcomes is unclear. The aim of this study was to describe the longitudinal trend and prognostic value of Gal-3 levels after HT. METHODS: Banked serum samples were available from 122 HT recipients, collected before transplant and at 1, 3, 6, and 12 months posttransplant. Gal-3 levels in these serum samples were measured by enzyme immune assay. Multivariable Cox regression was performed to determine the prognostic value of 12-month posttransplant Gal-3 serum levels. The primary endpoint was the composite variable all-cause death or graft failure over long-term posttransplant follow-up. RESULTS: Circulating Gal-3 concentration steadily decreased during the first year after HT (median values: pretransplant, 19.1 ng/mL; 1-year posttransplant, 14.6 ng/mL; P<.001). Circulating Gal-3 levels 1-year posttransplant were associated with an increased risk of all-cause death or graft failure (adjusted HR per 1 ng/mL, 1.04; 95%CI, 1.01-1.08; P=.008). The predictive accuracy of this biomarker was moderate: area under the ROC curve, 0.72 (95%CI, 0.60-0.82; P<.001). CONCLUSIONS: Circulating Gal-3 steadily decreased during the first year after HT. However, 1-year posttransplant Gal-3 serum levels that remained elevated were associated with increased long-term risk of death and graft failure.


Assuntos
Galectina 3/sangue , Rejeição de Enxerto/sangue , Transplante de Coração , Biomarcadores/sangue , Causas de Morte/tendências , Feminino , Seguimentos , Rejeição de Enxerto/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Fatores de Tempo
9.
Eur J Heart Fail ; 20(2): 385-394, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28580728

RESUMO

AIM: To analyse the incidence, risk factors and clinical outcomes of late graft failure after heart transplantation. METHODS AND RESULTS: We conducted an observational, single-centre study based on 547 patients who underwent cardiac transplantation from 1991 to 2014 and who survived the in-hospital postoperative period. Late graft failure was defined as the first hospitalization due to this condition after discharge. Over a mean follow-up of 8.4 ± 6 years, 178 (32.5%) patients were hospitalized due to late graft failure [incidence rate: 3.6 cases per 100 patient-years, 95% confidence interval (CI) 3.1-4.2]. Pre-transplant diabetes, higher pre-transplant transpulmonary pressure gradient and lower donor-recipient weight ratio were independently associated with higher risk of graft failure. Cardiac allograft vasculopathy, cellular rejection grade ≥1R, and antibody-mediated rejection grade ≥1 were detected in 50.6%, 44.9% and 19.2% patients, respectively, admitted due to graft failure. Left ventricular ejection fraction was ≥50% in 60.1% of these patients. Re-transplant free survival 1, 5, 10 and 15 years after the diagnosis of late graft failure was 72.2%, 38.4%, 18.4%, and 7.5%, respectively; the incidence rate of re-hospitalization due to decompensated heart failure was 40.9 episodes per 100 patient-years (95% CI 36.6-46.1). The need for inotropes, the presence of cardiac allograft vasculopathy, higher creatinine serum levels, lower ejection fraction and lower sodium serum levels were independent predictors of worse outcomes. CONCLUSIONS: Late graft failure is frequent after heart transplantation, as it is associated with poor outcomes. Rejection and cardiac allograft vasculopathy are the most frequent underlying causes.


Assuntos
Rejeição de Enxerto/epidemiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Medição de Risco , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo
10.
BMJ Open ; 7(1): e011437, 2017 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-28073791

RESUMO

INTRODUCTION: Rapid deployment valves (RDV) represent a newly introduced approach to aortic valve replacement which facilitates surgical implantation and minimally invasive techniques, shortens surgical times and shows excellent haemodynamic performance. However, evidence on their safety, efficacy and potential complications is mostly fitted with small-volume and retrospective studies. Moreover, no current guidelines exist. To improve our knowledge on this technology, The Rapid Deployment Aortic Replacement (RADAR) Registry will be established across Spain with the aim of assessing RDV outcomes in the real-world setting. METHODS AND ANALYSIS: The RADAR Registry is designed as a product registry that would provide information on its use and outcomes in clinical practice. This multicentre, prospective, national effort will initially involve 4 centres in Spain. Any patient undergoing cardiac surgery for aortic valve replacement and receiving an RDV as an isolated operation or in combination with other cardiac procedures may be included. Participation is voluntary. Data collection is equal to information obtained during standard care and is prospectively entered by the participating physicians perioperatively and during subsequent follow-up visits. The primary outcome assessed is in-hospital and up to 5 years of follow-up, prosthetic valve functioning and clinical status. Secondary outcomes are to perform subgroup analysis, to compare outcomes with other existing approaches and to develop future clinical guidelines. The follow-up assessments are timed with routine clinical appointments. Dissociated data will be extracted and collectively analysed. Initial target sample size for the registry is 500 participants entered with complete follow-up information. Different substudies will be implemented within the registry to investigate specific populations undergoing aortic valve replacement. ETHICS AND DISSEMINATION: The protocol is approved by all local institutional ethics committees. Findings will be shared by the participant hospitals, policymakers and the academic community to promote quality monitoring and efficient use of this technology.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Sistema de Registros/estatística & dados numéricos , Estenose da Valva Aórtica/mortalidade , Protocolos Clínicos , Coleta de Dados , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Formulação de Políticas , Estudos Prospectivos , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Resultado do Tratamento
11.
J Thorac Cardiovasc Surg ; 153(6): 1275-1284.e7, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28291607

RESUMO

OBJECTIVES: The enlargement of the left atrium has been identified as a marker of chronically increased left ventricular filling pressure and left ventricular diastolic dysfunction. This study aims to evaluate the association of indexed left atrial diameter with stroke, cardiovascular mortality, the combined event, and all-cause mortality in patients who underwent aortic valve surgery. METHODS: Indexed left atrial diameter was measured in 2011 adult patients (mean age, 70.9 ± 10.8 years; 58.7% were men) who underwent aortic valve surgery between January 2008 and March 2016. RESULTS: On the basis of the criteria of the American Society of Echocardiography, indexed left atrial diameter was normal in 64% of patients, mildly enlarged in 12.4% of patients, moderately enlarged in 9.2% of patients, and severely enlarged in 14.3% of patients. Over a mean follow-up period of 3.2 ± 2.1 years, there were 334 deaths and 97 strokes. Cardiovascular mortality survival at 5 years among patients with normal, mild, moderate, and severe left atrial enlargement was 91.6%, 86.8%, 77.9%, and 77.4%, respectively (P < .001). After covariable adjustment, Cox regression analysis showed indexed left atrial diameter as an independent predictor of all-cause mortality (hazard ratio per 1-cm/m2 increment, 1.545; 95% confidence interval, 1.252-1.906, P < .001), cardiovascular death (hazard ratio per 1-cm/m2 increment, 1.971; 95% confidence interval, 1.541-2.520; P < .001), and the combined event (hazard ratio per 1-cm/m2 increment, 1.673; 95% confidence interval, 1.321-2.119; P < .001). CONCLUSIONS: Indexed left atrial diameter is a strong predictor of long-term outcomes in patients with aortic valve diseases who undergo surgery.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Função do Átrio Esquerdo , Remodelamento Atrial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Rev Esp Cardiol (Engl Ed) ; 70(8): 639-645, 2017 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28209304

RESUMO

INTRODUCTION AND OBJECTIVES: To study the prognostic impact of preoperative nutritional status, as assessed through the nutritional risk index (NRI), on postoperative outcomes after heart transplantation (HT). METHODS: We conducted a retrospective, single-center study of 574 patients who underwent HT from 1991 to 2014. Preoperative NRI was calculated as 1.519 × serum albumin (g/L) + 41.7 × (body weight [kg] / ideal body weight [kg]). The association between preoperative NRI and postoperative outcomes was analyzed by means of multivariable logistic regression and multivariable Cox regression. RESULTS: Mean NRI before HT was 100.9 ± 9.9. According to this parameter, the prevalence of severe nutritional risk (NRI < 83.5), moderate nutritional risk (83.5 ≤ NRI < 97.5), and mild nutritional risk (97.5 ≤ NRI < 100) was 5%, 22%, and 10%, respectively. One year post-transplant mortality rates in these 4 categories were 18.2%, 25.3%, 7.9% and 10.2% (P < .001), respectively. The NRI was independently associated with a lower risk of postoperative infection (adjusted OR, 0.97; 95%CI, 0.95-1.00; P = .027) and prolonged postoperative ventilator support (adjusted OR, 0.96; 95%CI, 0.94-0.98; P = .001). Patients at moderate or severe nutritional risk had significantly higher 1-year post-HT mortality (adjusted HR, 1.55; 95%CI, 1.22-1.97; P < .001). CONCLUSIONS: Malnourished patients have a higher risk of postoperative complications and mortality after HT. Preoperative NRI determination may help to identify HT candidates who might benefit from nutritional intervention.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Desnutrição/diagnóstico , Avaliação Nutricional , Feminino , Insuficiência Cardíaca/mortalidade , Transplante de Coração/mortalidade , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Desnutrição/mortalidade , Pessoa de Meia-Idade , Estado Nutricional , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Disfunção Primária do Enxerto/etiologia , Disfunção Primária do Enxerto/mortalidade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/mortalidade
13.
BMJ Open ; 7(8): e017187, 2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28780562

RESUMO

INTRODUCTION: Cardiac adipose tissue is a source of progenitor cells with regenerative capacity. Studies in rodents demonstrated that the intramyocardial delivery of cells derived from this tissue improves cardiac function after myocardial infarction (MI). We developed a new reparative approach for damaged myocardium that integrates the regenerative properties of cardiac adipose tissue with tissue engineering. In the adipose graft transposition procedure (AGTP), we dissect a vascularised flap of autologous pericardial adipose tissue and position it over the myocardial scarred area. Following encouraging results in acute and chronic MI porcine models, we performed the clinical trial (NCT01473433, AdiFLAP trial) to evaluate safety in patients with chronic MI undergoing coronary artery bypass graft. The good safety profile and trends in efficacy warranted a larger trial. STUDY DESIGN: The AGTP II trial (NCT02798276) is an investigator initiated, prospective, randomised, controlled, multicentre study to assess the efficacy of the AGTP in 108 patients with non-revascularisable MI. Patients will be assigned to standard clinical practice or the AGTP. The primary endpoint is change in necrotic mass ratio by gadolinium enhancement at 91 and 365 days. Secondary endpoints include improvement in regional contractibility by MRI at 91 and 365 days; changes in functional MRI parameters (left ventricular ejection fraction, left and right ventricular geometric remodelling) at 91 and 365 days; levels of N-terminal prohormone of brain natriuretic peptide (NT-proBNP) at 7, 91 and 365 days; appearance of arrhythmias from 24 hour Holter monitoring at 24 hours, and at 91 and 365 days; all cause death or re-hospitalisation at 365 days; and cardiovascular death or re-hospitalisation at 365 days. ETHICS AND DISSEMINATION: The institutional review board approved the trial which will comply with the Declaration of Helsinki. All patients will provide informed consent. It may offer a novel, effective and technically simple technique for patients with no other therapeutic options. The results will be submitted to indexed medical journals and national and international meetings. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov: NCT02798276, pre-results.


Assuntos
Tecido Adiposo/transplante , Cicatriz/cirurgia , Ponte de Artéria Coronária , Infarto do Miocárdio/cirurgia , Miocárdio/patologia , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Regeneração/fisiologia , Projetos de Pesquisa , Adulto , Volume Cardíaco , Ponte de Artéria Coronária/efeitos adversos , Feminino , Humanos , Masculino , Infarto do Miocárdio/fisiopatologia , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Estudos Prospectivos , Transplante Autólogo , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
14.
Rev Esp Cardiol (Engl Ed) ; 69(12): 1160-1166, 2016 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27597125

RESUMO

INTRODUCTION AND OBJECTIVES: To assess the potential association between recipient Toxoplasma gondii serostatus and outcomes after heart transplant (HT). METHODS: We conducted a retrospective single-center study of 657 HT recipients from 1991 to 2015. Survival and the incidence of adverse clinical events of T. gondii-seropositive (n = 481) vs T. gondii-seronegative (n = 176) recipients were compared by means of 2 different multivariable Cox regression models. Model 1 included solely age and sex, and model 2 included other potential confounders. RESULTS: Over a median follow-up of 2903 days (interquartile range: 898-4757), 250 seropositive recipients (52%) and 72 seronegative recipients (41%) died. Univariable analysis showed increased posttransplant mortality among T. gondii-seropositive recipients (hazard ratio [HR] = 1.31; 95% confidence interval [95%CI], 1,00-1.70). After multivariable adjustment, the statistical significance of this association was lost (model 1: HR = 1.09; 95%CI, 0.83-1.43; model 2:HR = 1.12; 95%CI, 0.85-1.47). Recipient T. gondii seropositivity was independently associated with an increased risk of acute rejection (model 1: HR = 1.36; 95%CI, 1.06-1.74; model 2: HR = 1.29; 95%CI, 1.01-1.66). Multivariable models showed no statistically significant impact of recipient T. gondii serostatus on the incidence of infection, malignancy, coronary allograft vasculopathy, or the composite outcome of cardiac death or retransplant. No significant association was found between donor-recipient T. gondii serostatus matching and posttransplant outcome. CONCLUSIONS: In this study, recipient T. gondii serostatus was not an independent predictor of long-term post-HT outcome.


Assuntos
Rejeição de Enxerto/epidemiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Toxoplasma/imunologia , Toxoplasmose/epidemiologia , Adulto , Idoso , Feminino , Rejeição de Enxerto/prevenção & controle , Humanos , Imunossupressores/uso terapêutico , Incidência , Masculino , Pessoa de Meia-Idade , Mortalidade , Análise Multivariada , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Toxoplasmose/imunologia
16.
J Heart Lung Transplant ; 34(2): 167-74, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25434523

RESUMO

BACKGROUND: A high frequency of venous thromboembolism (VTE) has been observed after lung, kidney, and liver transplantation. However, data about the incidence of this complication among heart transplant (HT) recipients are lacking. METHODS: We analyzed the incidence, recurrence, and predisposing factors of VTE in a single-center cohort of 635 patients who underwent HT from April 1991 to April 2013. Deep venous thrombosis (DVT) and pulmonary embolism (PE) were considered as VTE episodes. RESULTS: During a median post-transplant follow-up of 8.4 years, 62 VTE episodes occurred in 54 patients (8.5%). Incidence rates of VTE, DVT, and PE were, respectively, 12.7 (95% confidence interval [CI], 9.7-16.3), 8.4 (95% CI, 6.0-11.4), and 7.0 (95% CI 4.8-9.7) episodes per 1,000 patient-years. Incidence rates of VTE during the first post-transplant year and beyond were, respectively, 45.1 (95% CI, 28.9-67.1) and 8.7 (95% CI 6.2-11.2) episodes per 1,000 patient-years. The incidence rate of VTE recurrence after a first VTE episode was 30.5 (95% CI, 13.2-60.2) episodes per 1,000 patient-years. By means of multivariable Cox regression, chronic renal dysfunction, older age, obesity, and the use of mammalian target of rapamycin inhibitors were identified as independent risk factors for VTE among HT recipients. CONCLUSIONS: VTE is a frequent complication after HT, mainly during the first post-operative year. In view of a high recurrence rate, long-term anti-coagulation should be considered in HT recipients who experience a first VTE episode.


Assuntos
Transplante de Coração/efeitos adversos , Complicações Pós-Operatórias , Tromboembolia Venosa/epidemiologia , Biópsia , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Prognóstico , Recidiva , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiologia
17.
J Eval Clin Pract ; 21(1): 34-42, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25040767

RESUMO

RATIONALE, AIMS AND OBJECTIVES: Transcatheter aortic valve implantation constitutes an example of a technology introduced into the Galician Health Care System basket and subjected to a post-introduction observational study after coverage. This paper aims to describe the process and results of this experience, illustrating the main challenges and opportunities in using these studies for supporting decision making. METHODS: The study protocol was developed by a multidisciplinary team consisting of experts from the Galician HTA Agency (avalia-t), interventional cardiologists and cardiac surgeons. Together they agreed on the information that was relevant and feasible for collection, and planned the study design, data collection and analysis of results. RESULTS: During the 1-year recruitment period, 94 patients underwent percutaneous aortic valve replacement in the three authorized centres. Implantation rate and prosthesis models differed substantially across the centres. Overall, procedural success rate was 96.8% and hospital mortality was 7.4%. Complications during post-surgical admission were recorded in 40.4% of patients. Moderate residual aortic regurgitation was observed in 10% of patients, and the procedure was associated with a stroke rate of 3.3% at 30 days and 5.3% at 1 year. CONCLUSIONS: Post-introduction observation has made it feasible to determine the use of this procedure within the SERGAS context and has enabled the assessment of performance in real-life conditions. The proposed strategic actions and interventions have been drawn up based upon the collective judgement of a group of experienced professionals, and have served to establish recommendations on further research that would be required to optimize health benefits.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Espanha , Fatores de Tempo
18.
Interact Cardiovasc Thorac Surg ; 21(3): 374-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26093954

RESUMO

OBJECTIVES: Lower mini-sternotomy represents a minimally invasive surgical technique that has been utilized for the repair of a wide variety of congenital heart defects with excellent surgical and cosmetic outcomes. However, clinical improvements provided for this technique beyond cosmetic results are controversial. The aim of our study is to report our results with lower mini-sternotomy for the repair of congenital heart malformations and compare them with a matched group with a full median sternotomy approach. METHODS: From 2010 through 2013, 105 consecutive congenital patients (81 paediatric) underwent lower mini-sternotomy at our centre (Group 1). We analysed in-hospital and follow-up outcomes, and compare them with an age-sex-diagnosis-type of surgery-matched group (Group 2). Both groups were managed following the same clinical protocols. RESULTS: In Group 1, age at the time of surgery was 12 ± 17 years (range from 0.2 to 64.6 years). In this group, 81 patients were paediatric and 62 were female. Operative techniques were atrial septal defect (n = 72), ventricular septal defect (n = 24) and atrioventricular canal repairs (n = 9). There were no deaths or major in-hospital complications. Two adult patients required conversion to full median sternotomy. For a medium follow-up of 1.5 years (range from 1 month to 5 years), there were no deaths, reinterventions or reoperations and no significant residual defects were found. Compared with Group 2, patients in Group 1 had longer cardiopulmonary bypass times (58.71 ± 19.08 vs 45.39 ± 20.45, P < 0.001) and cross-clamp times (32.75 ± 13.11 vs 23.22 ± 13.93, P < 0.001), higher rate of early extubation (96 vs 85%, P = 0.018) and lower rate of postoperative complications (11.6 vs 22.3%, P = 0.034). CONCLUSIONS: At our centre, lower mini-sternotomy represents a safe alternative for the repair of congenital heart defects in paediatric and adult populations. Cardiopulmonary bypass and cross-clamp times were longer in the mini-sternotomy group. However, these patients showed earlier extubation and less postoperative complications when compared with patients with a full sternotomy approach. Combined with improved cosmetic outcomes, lower mini-sternotomy could represent the technique of choice for these populations.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiopatias Congênitas/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Satisfação do Paciente , Esternotomia/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
20.
J Thorac Cardiovasc Surg ; 148(6): 2845-53.e1, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25131169

RESUMO

OBJECTIVE: The present study aimed to identify potential differences in hemodynamic performance between the supra-annular CarboMedics Top Hat valve and the intra-annular CarboMedics standard valve in terms of the long-term left ventricular mass reduction and transvalvular gradients. METHODS: We retrospectively reviewed a series of 186 consecutive patients who had undergone aortic valve replacement with a small size mechanical prosthesis at our institution from 2003 to 2013, receiving either a CarboMedics Top Hat valve (53 patients, valve size, 21 mm in 52.8% and 23 mm in 47.2%) or a CarboMedics standard prosthesis (133 patients, valve size, 19 mm in 14.3% and 21 mm in 85.7%). RESULTS: The in-hospital mortality was 9.4% and 11.3% in the Top Hat and standard groups, respectively (P = .71). The mean percentage of left ventricular mass reduction was greater in the Top Hat group (33% ± 15.8% vs 20.1% ± 16.6%, P < .001). The mean postoperative peak aortic gradient was lower in the Top Hat group (19.9 ± 8.9 vs 29.6 ± 8.6 mm Hg; P < .001). Spearman analysis showed a positive correlation between the indexed effective orifice area and the percentage of left ventricular mass reduction (Rho = +0.65, P = .02). The survival in the Top Hat group was 79.7% and 71.7% at 5 and 10 years, respectively. In the standard group, survival was 66.8% and 61.5% at 5 and 10 years, respectively (log-rank test, 0.19). Cox regression demonstrated severe myocardial hypertrophy (hazard ratio, 2.559; 95% confidence interval, 1.095-5.981) as one of the independent predictors of survival. CONCLUSIONS: The Top Hat valve surpasses hemodynamically the intra-annular valve. We suggest the supra-annular Top Hat prosthesis can be especially recommended for patients with a small aortic root and severe myocardial hypertrophy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hipertrofia Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Mortalidade Hospitalar , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/mortalidade , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA