1.
Rapid Commun Mass Spectrom ; 38(6): e9657, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38342682

RESUMO

RATIONALE: Characterization of Regolith And Trace Economic Resources (CRATER), an Orbitrap™-based laser desorption mass spectrometry instrument designed to conduct high-precision, spatially resolved analyses of planetary materials, is capable of answering outstanding science questions about the Moon's formation and the subsequent processes that have modified its (sub)surface. METHODS: Here, we describe the baseline design of the CRATER flight model, which requires <20 000 cm3  volume, <10 kg mass, and <60 W peak power. The analytical capabilities and performance metrics of a prototype that meets the full functionality of the flight model are demonstrated. RESULTS: The instrument comprises a high-power, solid-state, pulsed ultraviolet (213 nm) laser source to ablate the surface of the lunar sample, a custom ion optical interface to accelerate and collimate the ions produced at the ablation site, and an Orbitrap mass analyzer capable of discriminating competing isobars via ultrahigh mass resolution and high mass accuracy. The CRATER instrument can measure elemental and isotopic abundances and characterize the organic content of lunar surface samples, as well as identify economically valuable resources for future exploration. CONCLUSION: An engineering test unit of the flight model is currently in development to serve as a pathfinder for near-term mission opportunities.

2.
Analyst ; 142(12): 2109-2117, 2017 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-28548668

RESUMO

A limitation of conventional quadrupole ion trap scan modes which use rf amplitude control for mass scanning is that, in order to detect a subset of an ion population, the rest of the ion population must also be interrogated. That is, ions cannot be detected out of order; they must be detected in order of either increasing or decreasing mass-to-charge (m/z). However, an ion trap operated in the ac frequency scan mode, where the rf amplitude is kept constant and instead the ac frequency is used for mass-selective operations, has no such limitation because any variation in the ac frequency affects only the subset of ions whose secular frequencies match the perturbation frequency. Hence, an ion trap operated in the ac frequency scan mode can perform any arbitrary mass scan, as well as a sequence of scans, using a single ion injection; we demonstrate both capabilities here. Combining these two capabilities, we demonstrate the acquisition of a full mass spectrum, a product ion spectrum, and a second generation product ion spectrum using a single ion injection event. We further demonstrate a "segmented scan" in which different mass ranges are interrogated at different rf amplitudes in order to improve resolution over a portion of the mass range, and a "periodic scan" in which ions are continuously introduced into the ion trap to achieve a nearly 100% duty cycle. These unique scan modes, along with other characteristics of ac frequency scanning, are particularly appropriate for miniature ion trap mass spectrometers. Hence, implementation of ac frequency scanning on a prototype of the Mars Organic Molecule Analyzer mass spectrometer is also described.

3.
Int J Mass Spectrom ; 422: 177-187, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33005095

RESUMO

The Mars Organic Molecule Analyzer (MOMA), a dual-source, ion trap-based instrument capable of both pyrolysis-gas chromatography mass spectrometry (pyr/GC-MS) and laser desorption/ionization mass spectrometry (LDI-MS), is the core astrobiology investigation on the ExoMars rover. The MOMA instrument will be the first spaceflight mass analyzer to exploit the LDI technique to detect refractory organic compounds and characterize host mineralogy; this mode of analysis will be conducted at Mars ambient conditions. In order to achieve high performance in the Martian environment while keeping the instrument compact and low power, a number of innovative designs and components have been implemented for MOMA. These include a miniaturized linear ion trap (LIT), a fast actuating aperture valve with ion inlet tube. and a Microelectromechanical System (MEMS) Pirani sensor. Advanced analytical capabilities like Stored Waveform Inverse Fourier Transform (SWIFT) for selected ion ejection and tandem mass spectrometry (MS/MS) are realized in LDI-MS mode, and enable the isolation and enhancement of specific mass ranges and structural analysis, respectively. We report here the technical details of these instrument components as well as system-level analytical capabilities, and we review the applications of this technology to Mars and other high-priority targets of planetary exploration.

4.
Astrobiology ; 23(6): 657-669, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37134219

RESUMO

Studies of psychrophilic life on Earth provide chemical clues as to how extraterrestrial life could maintain viability in cryogenic environments. If living systems in ocean worlds (e.g., Enceladus) share a similar set of 3-mer and 4-mer peptides to the psychrophile Colwellia psychrerythraea on Earth, spaceflight technologies and analytical methods need to be developed to detect and sequence these putative biosignatures. We demonstrate that laser desorption mass spectrometry, as implemented by the CORALS spaceflight prototype instrument, enables the detection of protonated peptides, their dimers, and metal adducts. The addition of silicon nanoparticles promotes the ionization efficiency, improves mass resolving power and mass accuracies via reduction of metastable decay, and facilitates peptide de novo sequencing. The CORALS instrument, which integrates a pulsed UV laser source and an Orbitrap™ mass analyzer capable of ultrahigh mass resolving powers and mass accuracies, represents an emerging technology for planetary exploration and a pathfinder for advanced technique development for astrobiological objectives. Teaser: Current spaceflight prototype instrument proposed to visit ocean worlds can detect and sequence peptides that are found enriched in at least one strain of microbe surviving in subzero icy brines via silicon nanoparticle-assisted laser desorption analysis.


Assuntos
Nanopartículas , Voo Espacial , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Silício/química , Peptídeos , Nanopartículas/química
5.
Astrobiology ; 23(12): 1337-1347, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38079231

RESUMO

The highly compact Linear Ion Trap Mass Spectrometer (LITMS), developed at NASA Goddard Space Flight Center, combines Mars-ambient laser desorption-mass spectrometry (LD-MS) and pyrolysis-gas chromatography-mass spectrometry (GC-MS) through a single, miniaturized linear ion trap mass analyzer. The LITMS instrument is based on the Mars Organic Molecule Analyser (MOMA) investigation developed for the European Space Agency's ExoMars Rover Mission with further enhanced analytical features such as dual polarity ion detection and a dual frequency RF (radio frequency) power supply allowing for an increased mass range. The LITMS brassboard prototype underwent an extensive repackaging effort to produce a highly compact system for terrestrial field testing, allowing for molecular sample analysis in rugged planetary analog environments outside the laboratory. The LITMS instrument was successfully field tested in the Mars analog environment of the Atacama Desert in 2019 as part of the Atacama Rover Astrobiology Drilling Studies (ARADS) project, providing the first in situ planetary analog analysis for a high-fidelity, flight-like ion trap mass spectrometer. LITMS continued to serve as a laboratory tool for continued analysis of natural Atacama samples provided by the subsequent 2019 ARADS final field campaign.


Assuntos
Marte , Voo Espacial , Exobiologia/métodos , Espectrometria de Massas , Cromatografia Gasosa-Espectrometria de Massas/métodos
6.
Anal Chem ; 84(8): 3514-22, 2012 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-22356211

RESUMO

MALDI imaging allows the creation of a "molecular image" of a tissue slice. This image is reconstructed from the ion abundances in spectra obtained while rastering the laser over the tissue. These images can then be correlated with tissue histology to detect potential biomarkers of, for example, aberrant cell types. MALDI, however, is known to have problems with ion suppression, making it difficult to correlate measured ion abundance with concentration. It would be advantageous to have a method which could provide more accurate protein concentration measurements, particularly for screening applications or for precise comparisons between samples. In this paper, we report the development of a novel MALDI imaging method for the localization and accurate quantitation of proteins in tissues. This method involves optimization of in situ tryptic digestion, followed by reproducible and uniform deposition of an isotopically labeled standard peptide from a target protein onto the tissue, using an aerosol-generating device. Data is acquired by MALDI multiple reaction monitoring (MRM) mass spectrometry (MS), and accurate peptide quantitation is determined from the ratio of MRM transitions for the endogenous unlabeled proteolytic peptides to the corresponding transitions from the applied isotopically labeled standard peptides. In a parallel experiment, the quantity of the labeled peptide applied to the tissue was determined using a standard curve generated from MALDI time-of-flight (TOF) MS data. This external calibration curve was then used to determine the quantity of endogenous peptide in a given area. All standard curves generate by this method had coefficients of determination greater than 0.97. These proof-of-concept experiments using MALDI MRM-based imaging show the feasibility for the precise and accurate quantitation of tissue protein concentrations over 2 orders of magnitude, while maintaining the spatial localization information for the proteins.


Assuntos
Proteínas/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Animais , Encéfalo/metabolismo , Encéfalo/ultraestrutura , Ratos
7.
J Mass Spectrom ; 55(1): e4454, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31663201

RESUMO

Since the inception of mass spectrometry more than a century ago, the field has matured as analytical capabilities have progressed, instrument configurations multiplied, and applications proliferated. Modern systems are able to characterize volatile and nonvolatile sample materials, quantitatively measure abundances of molecular and elemental species with low limits of detection, and determine isotopic compositions with high degrees of precision and accuracy. Consequently, mass spectrometers have a rich history and promising future in planetary exploration. Here, we provide a short review on the development of mass analyzers and supporting subsystems (eg, ionization sources and detector assemblies) that have significant heritage in spaceflight applications, and we introduce a selection of emerging technologies that may enable new and/or augmented mission concepts in the coming decades.

8.
Anal Chem ; 81(14): 5623-8, 2009 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-19548663

RESUMO

A multiplexed tandem mass spectrometry (MS/MS) technique known as iterative accumulation multiplexing (IAM) has been implemented on a hybrid quadrupole Fourier transform ion cyclotron resonance mass spectrometer (Q-FTICR-MS). The IAM experiment resulted in obtaining MS/MS spectra for six analytes in two MS/MS experiments while characteristic resolving power and mass measurement accuracies were maintained. Parent-product ion correlations were graphically represented in a "ratiogram" where each product ion is encoded with a ratio unique to the parent ion from which it was formed. This is the first example of multiplexed MS on a FTICR instrument where the ions are encoded externally to the ICR cell. By performing the encoding external to the ICR cell, one set of ions can be encoded while the previous set of ions is being analyzed in the cell, maximizing the use of the continuous ion current emanating from the electrospray ionization source.


Assuntos
Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Análise de Fourier , Humanos , Dados de Sequência Molecular , Peptídeos/química , Proteínas/química , Fatores de Tempo
9.
Instrum Sci Technol ; 37(3): 257-273, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-21785563

RESUMO

The temporal response of pulsed nano-electrospray ionization mass spectrometry (nano-ESI-MS) was studied and its influence on ion formation and detection was characterized. Rise and decay times for the mass resolved ion current were determined to be 20 ± 3 msec and 61 ± 5 msec, respectively, which led to a maximum pulse rate of 12 Hz. Pulsed nano-ESI operation was demonstrated from a multi-sprayer source controlled by a high voltage pulsing circuit constructed in-house. The desired source mode of operation (e.g. pulsing or continuous) can be realized solely by controlling the voltage applied to each sprayer.

10.
J Am Soc Mass Spectrom ; 19(12): 1914-25, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18708289

RESUMO

A novel algorithm based on Data Self-Recalibration and a subsequent Mixture Mass Fingerprint search (DASER-MMF) has been developed to improve the performance of protein identification from online 1D and 2D-LC-MS/MS experiments conducted on high-resolution mass spectrometers. Recalibration of 40% to 75% of the MS spectra in a human serum dataset is demonstrated with average errors of 0.3 +/- 0.3 ppm, regardless of the original calibration quality. With simple protein mixtures, the MMF search identifies new proteins not found in the MS/MS based search and increases the sequence coverage for identified proteins by six times. The high mass accuracy allows proteins to be identified with as little as three peptide mass hits. When applied to very complex samples, the MMF search shows less dramatic performance improvements. However, refinements such as additional discriminating factors utilized within the search space provide significant gains in protein identification ability and indicate that further enhancements are possible in this realm.


Assuntos
Algoritmos , Mapeamento de Peptídeos/estatística & dados numéricos , Proteínas/química , Animais , Proteínas Sanguíneas/química , Bovinos , Cromatografia Líquida , Bases de Dados de Proteínas , Humanos , Espectrometria de Massas em Tandem
11.
Annu Rev Anal Chem (Palo Alto Calif) ; 10(1): 141-156, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28301752

RESUMO

The use of coded apertures in mass spectrometry can break the trade-off between throughput and resolution that has historically plagued conventional instruments. Despite their very early stage of development, coded apertures have been shown to increase throughput by more than one order of magnitude, with no loss in resolution in a simple 90-degree magnetic sector. This enhanced throughput can increase the signal level with respect to the underlying noise, thereby significantly improving sensitivity to low concentrations of analyte. Simultaneous resolution can be maintained, preventing any decrease in selectivity. Both one- and two-dimensional (2D) codes have been demonstrated. A 2D code can provide increased measurement diversity and therefore improved numerical conditioning of the mass spectrum that is reconstructed from the coded signal. This review discusses the state of development, the applications where coding is expected to provide added value, and the various instrument modifications necessary to implement coded apertures in mass spectrometers.

12.
Astrobiology ; 17(6-7): 655-685, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31067288

RESUMO

The Mars Organic Molecule Analyzer (MOMA) instrument onboard the ESA/Roscosmos ExoMars rover (to launch in July, 2020) will analyze volatile and refractory organic compounds in martian surface and subsurface sediments. In this study, we describe the design, current status of development, and analytical capabilities of the instrument. Data acquired on preliminary MOMA flight-like hardware and experimental setups are also presented, illustrating their contribution to the overall science return of the mission. Key Words: Mars-Mass spectrometry-Life detection-Planetary instrumentation. Astrobiology 17, 655-685.

13.
J Am Soc Mass Spectrom ; 26(9): 1633-40, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26111517

RESUMO

Miniaturizing instruments for spectroscopic applications requires the designer to confront a tradeoff between instrument resolution and instrument throughput [and associated signal-to-background-ratio (SBR)]. This work demonstrates a solution to this tradeoff in sector mass spectrometry by the first application of one-dimensional (1D) spatially coded apertures, similar to those previously demonstrated in optics. This was accomplished by replacing the input slit of a simple 90° magnetic sector mass spectrometer with a specifically designed coded aperture, deriving the corresponding forward mathematical model and spectral reconstruction algorithm, and then utilizing the resulting system to measure and reconstruct the mass spectra of argon, acetone, and ethanol. We expect the application of coded apertures to sector instrument designs will lead to miniature mass spectrometers that maintain the high performance of larger instruments, enabling field detection of trace chemicals and point-of-use mass spectrometry.

14.
J Am Soc Mass Spectrom ; 26(2): 248-56, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25510933

RESUMO

In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many years to break a similar trade-off. To provide a viable path to miniaturization for harsh environment field applications, we are investigating similar concepts in sector mass spectrometry. Recently, we demonstrated the viability of 1D aperture coding and here we provide a first investigation of 2D coding. In coded optical spectroscopy, 2D coding is preferred because of increased measurement diversity for improved conditioning and robustness of the result. To investigate its viability in mass spectrometry, analytes of argon, acetone, and ethanol were detected using a custom 90-degree magnetic sector mass spectrometer incorporating 2D coded apertures. We developed a mathematical forward model and reconstruction algorithm to successfully reconstruct the mass spectra from the 2D spatially coded ion positions. This 2D coding enabled a 3.5× throughput increase with minimal decrease in resolution. Several challenges were overcome in the mass spectrometer design to enable this coding, including the need for large uniform ion flux, a wide gap magnetic sector that maintains field uniformity, and a high resolution 2D detection system for ion imaging. Furthermore, micro-fabricated 2D coded apertures incorporating support structures were developed to provide a viable design that allowed ion transmission through the open elements of the code.

15.
Astrobiology ; 15(2): 104-10, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25622133

RESUMO

Evidence from recent Mars missions indicates the presence of perchlorate salts up to 1 wt % level in the near-surface materials. Mixed perchlorates and other oxychlorine species may complicate the detection of organic molecules in bulk martian samples when using pyrolysis techniques. To address this analytical challenge, we report here results of laboratory measurements with laser desorption mass spectrometry, including analyses performed on both commercial and Mars Organic Molecule Analyzer (MOMA) breadboard instruments. We demonstrate that the detection of nonvolatile organics in selected spiked mineral-matrix materials by laser desorption/ionization (LDI) mass spectrometry is not inhibited by the presence of up to 1 wt % perchlorate salt. The organics in the sample are not significantly degraded or combusted in the LDI process, and the parent molecular ion is retained in the mass spectrum. The LDI technique provides distinct potential benefits for the detection of organics in situ on the martian surface and has the potential to aid in the search for signs of life on Mars.


Assuntos
Exobiologia , Espectrometria de Massas , Percloratos/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Cálcio/química , Carbonatos/química , Lasers , Magnésio/química , Marte , Compostos Orgânicos/química , Percloratos/química , Compostos Policíclicos/química , Rodaminas/química , Silicatos , Voo Espacial/instrumentação
16.
J Am Soc Mass Spectrom ; 14(10): 1099-109, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14530090

RESUMO

The performance of quadrupole ion traps using argon or air as the buffer gas was evaluated and compared to the standard helium only operation. In all cases a pure buffer gas, not mixtures of gases, was investigated. Experiments were performed on a Bruker Esquire ion trap, a Finnigan LCQ, and a Finnigan ITMS for comparison. The heavier gases were found to have some advantages, particularly in the areas of sensitivity and collision-induced dissociation efficiency; however, there is a significant resolution loss due to dissociation and/or scattering of ions. Additionally, the heavier gases were found to affect ion activation and deactivation during MS/MS, influencing the product ion intensities observed. Finally, the specific quadrupole ion trap design and the ion ejection parameters were found to be crucial in the quality of the spectra obtained in the presence of heavy gases. Operation with static pressures of heavy gases can be beneficial under certain design and operating conditions of the quadrupole ion trap.


Assuntos
Encefalina Leucina/análise , Gases/química , Espectrometria de Massas/métodos , Argônio/química , Soluções Tampão , Fenômenos Químicos , Físico-Química , Encefalina Leucina/química , Hélio/química , Pressão , Sensibilidade e Especificidade
17.
J Am Soc Mass Spectrom ; 25(7): 1295-304, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24806048

RESUMO

Conventionally, quadrupole ion trap mass spectrometers eject ions of different mass-to-charge ratio (m/z) in a sequential fashion by performing a scan of the rf trapping voltage amplitude. Due to the inherent sparsity of most mass spectra, the detector measures no signal for much of the scan time. By exploiting this sparsity property, we propose a new compressive and multiplexed mass analysis approach--multi Resonant Frequency Excitation (mRFE) ejection. This new approach divides the mass spectrum into several mass subranges and detects all the subrange spectra in parallel for increased mass analysis speed. Mathematical estimation of standard mass spectrum is demonstrated while statistical classification on the parallel measurements remains viable because of the sparse nature of the mass spectra. This method can reduce mass analysis time by a factor of 3-6 and increase system duty cycle by 2×. The combination of reduced analysis time and accurate compound classification is demonstrated in a commercial quadrupole ion trap (QIT) system.

18.
Rev Sci Instrum ; 81(6): 066103, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20590274

RESUMO

A continuously operated dual polarity dual nanoelectrospray ionization source has been constructed and tested. A commercial quadrupole ion trap mass spectrometer was modified to accumulate and trap ions of opposite charge. All changes to the commercial three-dimensional quadrupole ion trap have been made external to the instrument outside of the vacuum system. Few hardware modifications were required because the two emitters send ion beams through the same transmission guides. Computer controlled source voltage polarities are switched quickly and efficiently to transmit one of two continuously generated ion beams. With customized software, this design has proved simple to implement and to operate.

19.
Mol Ecol Resour ; 8(2): 290-4, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21585771

RESUMO

d-novl is a Monte Carlo program designed to generate a null expectation of overlap between two niche-based distribution models. The user may choose between two growth algorithms: the separated algorithm grows a random number of disjointed growth areas, whereas the number of islands algorithm allows the user to input the desired number of growth areas. The latter algorithm can also be used to grow a single growth area. The resulting probability distribution of expected overlap values can be exported into a spreadsheet for further analysis. d-novl is freely available for Mac and Windows platforms at http://www.mygalomorphae.org.

20.
Metabolomics ; 4(2): 128-140, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19081807

RESUMO

With unmatched mass resolution, mass accuracy, and exceptional detection sensitivity, Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) has the potential to be a powerful new technique for high-throughput metabolomic analysis. In this study, we examine the properties of an ultrahigh-field 12-Tesla (12T) FTICR-MS for the identification and absolute quantitation of human plasma metabolites, and for the untargeted metabolic fingerprinting of inbred-strain mouse serum by direct infusion (DI). Using internal mass calibration (mass error ≤1 ppm), we determined the rational elemental compositions (incorporating unlimited C, H, N and O, and a maximum of two S, three P, two Na, and one K per formula) of approximately 250 out of 570 metabolite features detected in a 3-min infusion analysis of aqueous extract of human plasma, and were able to identify more than 100 metabolites. Using isotopically-labeled internal standards, we were able to obtain excellent calibration curves for the absolute quantitation of choline with sub-pmol sensitivity, using 500 times less sample than previous LC/MS analyses. Under optimized serum dilution conditions, chemical compounds spiked into mouse serum as metabolite mimics showed a linear response over a 600-fold concentration range. DI/FTICR-MS analysis of serum from 26 mice from 2 inbred strains, with and without acute trichloroethylene (TCE) treatment, gave a relative standard deviation (RSD) of 4.5%. Finally, we extended this method to the metabolomic fingerprinting of serum samples from 49 mice from 5 inbred strains involved in an acute alcohol toxicity study, using both positive and negative electrospray ionization (ESI). Using these samples, we demonstrated the utility of this method for high-throughput metabolomics, with more than 400 metabolites profiled in only 24 h. Our experiments demonstrate that DI/FTICR-MS is well-suited for high-throughput metabolomic analysis.