Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMJ Case Rep ; 16(9)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37730423

RESUMO

A term newborn presented after birth with abdominal distension and vomiting in a developing country in Asia. Ultrasonography suggested intestinal obstruction and abdominal X-ray showed a 'double-bubble' sign suggestive of intestinal atresia. The newborn was diagnosed with early-onset neonatal sepsis secondary to intestinal obstruction and transferred to the neonatal intensive care unit. Surgery was performed and type IIIb jejunal atresia was found. Type IIIa/b jejunal atresia is associated with high incidence of poor outcome in lower socioeconomic countries. The affected intestinal segment and a distal serosal tear were resected and two end-to-end anastomoses formed. Oral feeding commenced on day 13 postoperatively. The patient was discharged on day 20 with adequate nutritional status. At follow-up, the patient continued to thrive. An operation involving resection of two different segments of bowel repaired with two end-to-end anastomoses in a neonate had a successful outcome for the patient.


Assuntos
Atresia Intestinal , Obstrução Intestinal , Lacerações , Recém-Nascido , Humanos , Atresia Intestinal/cirurgia , Anastomose Cirúrgica , Unidades de Terapia Intensiva Neonatal
2.
Eye (Lond) ; 37(2): 274-279, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35022568

RESUMO

BACKGROUND/OBJECTIVES: Handheld fundus cameras are portable and cheaper alternatives to table-top counterparts. To date there have been no studies comparing feasibility and clinical utility of handheld fundus cameras to table-top devices. We compare the feasibility and clinical utility of four handheld fundus cameras/retinal imaging devices (Remidio NMFOP, Volk Pictor Plus, Volk iNview, oDocs visoScope) to a table-top camera (Zeiss VisucamNM/FA). SUBJECTS/METHODS: Healthy participants (n = 10, mean age ± SD = 21.0 ± 0.9 years) underwent fundus photography with five devices to assess success/failure rates of image acquisition. Participants with optic disc abnormalities (n = 8, mean age ± SD = 26.8 ± 15.9) and macular abnormalities (n = 10, mean age ± SD = 71.6 ± 15.4) underwent imaging with the top three scoring fundus cameras. Images were randomised and subsequently validated by ophthalmologists masked to the diagnoses and devices used. RESULTS: Image acquisition success rates (100%) were achieved in non-mydriatic and mydriatic settings for Zeiss, Remidio and Pictor, compared with lower success rates for iNview and oDocs. Image quality and gradeability were significantly higher for Zeiss, Remidio and Pictor (p < 0.0001) compared to iNview and oDocs. For cup:disc ratio estimates, similar levels of bias were seen for Zeiss (-0.09 ± SD:0.15), Remidio (-0.07 ± SD:0.14) and Pictor (-0.05 ± SD:0.16). Diagnostic sensitivities were highest for Zeiss (84.9%; 95% CI, 78.2-91.5%) followed by Pictor (78.1%; 95% CI, 66.6-89.5%) and Remidio (77.5%; 95% CI, 65.9-89.0%). CONCLUSIONS: Remidio and Pictor achieve comparable results to the Zeiss table-top camera. Both devices achieved similar scores in feasibility, image quality, image gradeability and diagnostic sensitivity. This suggests that these devices potentially offer a more cost-effective alternative in certain clinical scenarios.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Retina , Humanos , Estudos de Viabilidade , Retina/diagnóstico por imagem , Angiofluoresceinografia , Fotografação/métodos , Fundo de Olho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA