Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Spine (Phila Pa 1976) ; 20(21): 2313-7, 1995 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-8553119

RESUMO

STUDY DESIGN: In a retrospective study, the incidence of false positive and false negative interpretation of x-rays for solid spinal arthrodesis with spinal instrumentation was evaluated in 75 patients. OBJECTIVE: To evaluate the accuracy of the interpretation of x-rays for diagnosing solid spinal arthrodesis in patients with spinal instrumentation. SUMMARY OF BACKGROUND DATA: This retrospective study compared spinal fusion, as determined by direct observation and radiographic evaluation, in 75 patients with instrumented lumbar fusions using multiple devices. The fusions included posterolateral fusions or posterolateral with interbody fusions. Autograft, allograft, and a combination of these also were used. METHODS: A single blinded examiner reviewed all x-rays immediately before the spinal hardware was removed and the fusion mass was explored by the surgeon. RESULTS: There was a positive correlation between x-rays and the observations at the time of surgery in only 68% of the patients. CONCLUSION: This study indicates that the accuracy of x-ray interpretation for spinal arthrodesis is only 68%. The L4-L5 level was the most difficult level to fuse and the most difficult to interpret using x-rays. Patients with persistent back pain, when nonmechanical causes have been ruled out, should be considered for surgical exploration of the fusion mass even if x-rays appear to indicate a solid fusion.


Assuntos
Fixadores Internos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Fusão Vertebral , Reações Falso-Negativas , Reações Falso-Positivas , Humanos , Radiografia , Reoperação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fusão Vertebral/instrumentação
2.
J Am Acad Orthop Surg ; 8(2): 133-9, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10799098

RESUMO

Quality health care has many definitions. Among those definitions is "care that consistently contributes to the improvement or maintenance of the quality and/or duration of life." The current evolution in health care has been fueled by three necessities frequently demanded by payers and employers: improvement in access, lowering of cost, and definition and quantification of the quality of care. This evolution has been facilitated by the so-called industrialization of medicine. This concept includes the adoption of industrial economic principles and techniques that facilitate the measurement of processes and outcomes. Quality health care is currently recognized as health care that is characterized by three elements: the use of practice guidelines or standards, the implementation of continuous quality improvement techniques, and the use of outcome determination and management. Practice guidelines demand the adoption of evidence-based principles in evaluation and care, as well as minimization of variations in evaluation and care. Continuous quality improvement seeks to determine why variations in processes of care occur and then to minimize those variations. Outcomes may be measured in terms of both very objective and very subjective variables and also on the basis of cost-efficiency. Most tools currently used to quantify outcomes, especially in orthopaedics, involve measurements of general health and of specific body part or organ system function. This evolution in health care is producing significant alterations in methods of traditional health-care delivery. The accumulating evidence indicates that these changes, although frequently unpopular, are improving the quality of health care.


Assuntos
Ortopedia/normas , Avaliação de Resultados em Cuidados de Saúde , Qualidade da Assistência à Saúde/normas , Feminino , Previsões , Humanos , Masculino , Ortopedia/tendências , Qualidade da Assistência à Saúde/tendências , Estados Unidos
3.
Orthop Clin North Am ; 16(3): 543-55, 1985 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3874383

RESUMO

We have applied computer programs originally developed for craniofacial surgical planning and evaluation to complex musculoskeletal problems. These computer programs reformat ordinary CT scans into black and white images of the three-dimensional osseous surfaces found in the scanned volume. These reformatted three-dimensional CT scan images increase the utility of CT scan examinations of complex osseous structures, such as the wrist, spine, hip, knee, and shoulder. The software, which operates on an unmodified commercially available CT scanner, can produce high-quality surface reconstructions from CT scan slices without operator intervention. No special knowledge of the principles used in the reconstruction methods is needed to successfully use the programs.


Assuntos
Sistema Musculoesquelético/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Condroma/diagnóstico por imagem , Exostose Múltipla Hereditária/diagnóstico por imagem , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/lesões , Escápula/diagnóstico por imagem , Tecnologia Radiológica , Punho/diagnóstico por imagem
4.
J Orthop Trauma ; 2(3): 245-9, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3225712

RESUMO

The effects of each of the surgical stages involved in compression plating on the development of cortical thinning and porosity were assessed in the intact midshaft, stress-shielded femoral segments of adult mongrel dogs 6 months postoperatively. The data were evaluated in terms of a postsurgical tetracycline-based measure of remodeling and terminal 85Sr clearance (SrC) values for the plated segments of bone. Drilling had no effect on any parameter. Screw application was associated with minimal cortical thinning (p less than 0.05), while plate fixation clearly promoted thinning (p less than 0.01) and porosity (p less than 0.05). The percentage of labeled osteons, a measure of remodeling activity, increased only after plate fixation (p less than 0.05), and the labeling patterns suggested that most osteons had formed during the first 4 postsurgical months. That none of these changes were correlated with the 6-month SrC values suggests that the development of plate-induced osteopenia involves disparate histomorphometric time constants, rather than lack of any association.


Assuntos
Placas Ósseas , Osso e Ossos/irrigação sanguínea , Fixação Interna de Fraturas/instrumentação , Isquemia/patologia , Complicações Pós-Operatórias/patologia , Radioisótopos de Estrôncio , Animais , Doenças Ósseas Metabólicas/patologia , Parafusos Ósseos , Osso e Ossos/patologia , Cães , Fêmur/irrigação sanguínea , Fluxo Sanguíneo Regional , Cicatrização
5.
J Orthop Trauma ; 6(4): 427-32, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1494095

RESUMO

Thirty-eight operatively treated fractures of the acetabulum were evaluated retrospectively for perioperative complications. Functionally significant heterotopic ossification (Brooker class III or IV) developed in 23% of those patients who did not receive adequate prophylactic irradiation or indomethacin. Irradiation and indomethacin were effective in the prevention of severe heterotopic ossification. The development of severe heterotopic ossification (class III or IV) was associated with increased time from injury to operation. We conclude that prophylaxis against heterotopic ossification is warranted to decrease the incidence of this potentially preventable complication in patients who incur significant time delays prior to surgery. Other significant complications included avascular necrosis (26%), infection (13%), and neural injury (16%). Avascular necrosis developed in one patient who did not have a documented dislocation.


Assuntos
Acetábulo/lesões , Fraturas Ósseas/complicações , Complicações Intraoperatórias/etiologia , Ossificação Heterotópica/etiologia , Acetábulo/cirurgia , Adolescente , Adulto , Feminino , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteonecrose/etiologia , Estudos Retrospectivos
6.
J Orthop Trauma ; 2(3): 241-4, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3225711

RESUMO

We examined the effect of rigid plate application on the radiostrontium clearance of the intact canine femur at 6 months. We examined each of the component surgical steps. We calculated the clearance both for the whole bone and for each of the five transverse sections of the whole bone. Screw application, but not drilling, increased the clearance in the segment about the screw holes. Plate application produced an increase in the segment beneath the plate as well as around the screws and in the whole bone. These changes are accomplished not only by an absolute increase in clearance to the middle three segments, but by a relative diminution in clearance by the most proximal and distal segments. The histomorphometric changes in long bones following rigid plating may be accompanied by regional increases in bone blood flow.


Assuntos
Placas Ósseas , Osso e Ossos/irrigação sanguínea , Fixação Interna de Fraturas/instrumentação , Isquemia/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Radioisótopos de Estrôncio , Animais , Doenças Ósseas Metabólicas/diagnóstico por imagem , Parafusos Ósseos , Cães , Fêmur/irrigação sanguínea , Cintilografia , Fluxo Sanguíneo Regional
7.
J Orthop Trauma ; 5(1): 34-7, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-2023041

RESUMO

This study addresses the comparative pull-out strengths of cortical (4.5 mm) and fully threaded cancellous (6.5 mm) bone screws from sites about the pelvis commonly used in the fixation of posterior column acetabular fractures and sacroiliac (SI) disruptions. These sites include one from lateral to medial through the posterior column, two from posterolateral to anteromedial across the SI joint, one vertically through the sacral ala, and one vertically through the iliopubic column. Statistical analysis showed no significant difference in the force required for pull-out failure of the cortical versus the cancellous screws at any of the sites tested.


Assuntos
Acetábulo/lesões , Parafusos Ósseos/normas , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Articulação Sacroilíaca/lesões , Acetábulo/cirurgia , Adulto , Idoso , Falha de Equipamento , Humanos , Pessoa de Meia-Idade , Articulação Sacroilíaca/cirurgia
8.
J Orthop Trauma ; 2(3): 229-33, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3225709

RESUMO

The pull-out strength of both cortical and cancellous screws from bone at various sites about cadaveric pelves was examined. No significant differences were seen between cortical or cancellous screws at similar sites with the possible exception of the sacroiliac joint. Pull-out strengths were best correlated to the depth of bone at a particular screw hole. For practical purposes, the strongest sites are in the thick buttress of bone along the iliopubic column.


Assuntos
Acetábulo/lesões , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Ossos Pélvicos/lesões , Acetábulo/cirurgia , Idoso , Fenômenos Biomecânicos , Humanos , Pessoa de Meia-Idade , Ossos Pélvicos/cirurgia
9.
Am J Orthop (Belle Mead NJ) ; 24(6): 475-8, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7670870

RESUMO

The sacroiliac joint itself and the specific diagnosis of sacroiliac dysfunction are both underappreciated causes of pain in the low back, the pelvis, and the proximal lower extremities. An anatomically atypical synovial joint, its extensive innervation accounts for multiple modes of pain presentation. The joint and its associated ligament complex are subjected to rather constant and significant stresses. These combined factors contribute to the body of patients who present with low-back, buttock, proximal-thigh, and groin pain. Physical examination usually is an attempt to assess for presumed abnormal motion of the sacroiliac or to provoke discomfort by stressing that joint. Nonoperative treatment is usually physical therapy, and both diagnostic and therapeutic injection of the sacroiliac joint may be employed. Surgery is a treatment of last resort. There is a lack of long-term studies that address the natural history of this problem and its treatment.


Assuntos
Artropatias , Dor Lombar/etiologia , Articulação Sacroilíaca , Fenômenos Biomecânicos , Diagnóstico Diferencial , Feminino , Humanos , Artropatias/diagnóstico , Artropatias/fisiopatologia , Artropatias/terapia , Masculino , Prognóstico , Articulação Sacroilíaca/anatomia & histologia , Articulação Sacroilíaca/inervação , Articulação Sacroilíaca/fisiopatologia
10.
Am J Orthop (Belle Mead NJ) ; 25(9): 608-12, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8886199

RESUMO

A retrospective analysis of 41 adult patients treated for a femoral neck fracture was performed to determine the variables that best predict total hospital charges. The patients were treated for an isolated femoral neck fracture at our hospital from January 1993 through December 1994. There were 13 men and 28 women. The average age at the time of injury was 63 years. The average length of stay was 12.1 days, and the average total hospital charges per patient were $16,072. No physician fees were included in our analysis. Detailed multivariate regression analysis of 10 variables was performed for each patient. Stepwise linear regression analysis, which controlled for all variable (such as age at injury, number of medical illnesses, gender, and others), revealed that the strongest predictors of total hospital charges were the number of medical illnesses (P < 0.0001), age at injury (P = 0.023), length of stay (P < 0.0001), and number of complications (P = 0.0007).


Assuntos
Fraturas do Colo Femoral/economia , Preços Hospitalares , Tempo de Internação , Complicações Pós-Operatórias/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Custos e Análise de Custo , Feminino , Fraturas do Colo Femoral/fisiopatologia , Fraturas do Colo Femoral/terapia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos
11.
Am J Orthop (Belle Mead NJ) ; 29(2): 93-7, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10695859

RESUMO

Orthopedic surgeons are trained to manage problems involving the musculoskeletal system. It would be helpful to identify certain procedures, anatomic areas, or issues related to the physician-patient relationship that could potentially lead to a malpractice lawsuit. Once the problems are identified, steps toward continuing education and physician awareness could be initiated. In this study, we performed a randomized nationwide survey of medical malpractice attorneys to evoke their opinion on these issues. We found that the lumbar spine was the most common anatomic area involved in orthopedic medical malpractice cases, and a physician appearing rushed and uninterested is most likely to be the subject of a lawsuit where a poor physician-patient relationship was a contributing factor. Educational and professional programs are needed to increase the awareness and knowledge of orthopedic malpractice risks, and also to identify potentially preventable problems leading to malpractice litigation.


Assuntos
Atitude Frente a Saúde , Jurisprudência , Imperícia/legislação & jurisprudência , Imperícia/estatística & dados numéricos , Ortopedia/legislação & jurisprudência , Ortopedia/estatística & dados numéricos , Adulto , Idoso , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Consentimento Livre e Esclarecido/legislação & jurisprudência , Consentimento Livre e Esclarecido/estatística & dados numéricos , Masculino , Erros Médicos/legislação & jurisprudência , Erros Médicos/estatística & dados numéricos , Pessoa de Meia-Idade , Ortopedia/educação , Ortopedia/métodos , Relações Médico-Paciente , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Inquéritos e Questionários , Estados Unidos
12.
Orthopedics ; 2(6): 608-13, 1979 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24822746

RESUMO

A retrospective study of our first year's experience with a sliding screw in intertrochanteric fractures was conducted. Forty-five patients with intertrochanteric fractures were admitted to St. Louis City Hospital in the year considered. All those who came to surgery were treated with a sliding screw. We were impressed by the ability of the sliding screw plate to adapt to the forces which, under other circumstances, cause the unstable I-T fractures to collapse or displace. The characteristics of unstable hip fractures are discussed.

13.
Orthopedics ; 20(2): 109-15, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9048387

RESUMO

One hundred ninety-five consecutive patients underwent 195 primary unilateral total hip arthroplasties between January 1988 and December 1993. Patients were divided into three groups based on the type of anesthesia utilized for their procedure. Group I consisted of 108 patients (59 women and 49 men; average age 56 years) who had general endotracheal anesthesia alone. Group II consisted of 70 patients (41 women and 29 men, average age 58 years) who had general endotracheal anesthesia with epidural augmentation intraoperatively and postoperatively. Group III consisted of 17 patients (6 women and 11 men, average age 62 years) who had epidural anesthesia only. Data were analyzed by anesthesia group to compare a variety of clinically relevant factors. No statistically significant differences among groups were noted regarding average age at surgery, the underlying diagnoses leading to joint replacement, the number of preexisting medical conditions, length of hospitalization, nonsurgical operating room time, intraoperative blood transfusions, intraoperative femur fractures, deep venous thrombosis, deep infections, death, or the prevalence of postoperative urinary tract infections. Postoperative urinary tract infections correlated with duration of Foley catheterization, but not the duration of epidural catheterization. Significant differences among anesthesia groups were observed for two factors: 1) estimated intraoperative blood loss was highest for Group I (P < .05) and was primarily a function of surgical time (P < .0001), and 2) postoperative Hemovac output (over the first and second postoperative 24-hour periods) was greatest for Group II (P < .05). Epidural anesthesia appears to be a safe modality in patients undergoing primary unilateral total hip replacement.


Assuntos
Anestesia Epidural , Anestesia por Inalação , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Epidural/métodos , Perda Sanguínea Cirúrgica , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Intubação Intratraqueal , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Tempo
14.
Orthop Rev ; 17(1): 123-5, 1988 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3174193

RESUMO

Intra-articular instillation of lidocaine into the hip joint is used as an adjunct in the diagnosis of some confusing hip problems. If the local anesthetic relieves the patient's symptoms, then arthroplasty--in its broadest meaning--is also likely to relieve the patient's symptoms.


Assuntos
Anestesia Local/métodos , Artrografia , Articulação do Quadril , Lidocaína/administração & dosagem , Idoso , Feminino , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade
15.
Clin Orthop Relat Res ; (291): 188-92, 1993 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8504598

RESUMO

In two cases of posterior wall acetabular fracture, the fracture fragment was too comminuted to be fixed per primam. A full-thickness iliac crest autograft was used as initial reconstruction in these two cases. Although the reconstruction was not anatomic, one of the two patients is functioning with only minimum symptoms at five years. Incorporation of the autograft has been documented in both cases. Although the procedure may not accurately reproduce the anatomy of the hip joint, it will appropriately supplement viable acetabular bone structure.


Assuntos
Acetábulo/lesões , Fraturas Ósseas/cirurgia , Ílio/transplante , Acidentes de Trânsito , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação
16.
J Arthroplasty ; 3(4): 379-80, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3241178

RESUMO

Removal of a well-fixed acetabular component can be difficult and may produce destruction of the acetabular bone bed. The authors describe a technique for removal of such a component with minimal bone destruction that involves the use of an offset punch and breaking the fixation interface in tension. This technique obviates the need for prying at the interface and fracturing the bone bed.


Assuntos
Acetábulo , Fraturas Ósseas/prevenção & controle , Prótese de Quadril , Humanos , Reoperação/efeitos adversos , Reoperação/instrumentação
17.
Orthop Rev ; 21(3): 327-34, 1992 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1565522

RESUMO

This study sought to compare five different brands of femoral components used in hip arthroplasty with regard to the quality of results 1 year postoperatively. The five components were Zimmer Pre-coat, Harris-Galante, porous-coated anatomic (PCA), Omnifit microstructured, and Omnifit collared. The same surgeon supervised all cases. Overall, the Pre-coat, Harris-Galante, PCA, and Omnifit microstructured components produced better results than did the Omnifit press-fit collared components. Within this time frame, neither individual patient characteristics nor intraoperative fractures had a statistically significant effect on the results, and there was no correlation with roentgenographic changes.


Assuntos
Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Fêmur/cirurgia , Humanos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/etiologia , Desenho de Prótese
18.
J Arthroplasty ; 10(6): 800-4, 1995 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8749764

RESUMO

The usefulness of angles measured on standardized radiographs to determine acetabular position and predict dislocation after primary total hip arthroplasty (THA) was reviewed retrospectively. Seventy-four patients (97 primary THAs) were reviewed. All patients underwent a standardized protocol of postoperative radiographs which included an anteroposterior view of the pelvis and a cross-table lateral radiograph of the hip. Two angles were measured to define acetabular position: the abduction angle was measured on the anteroposterior radiograph and the version angle was measured on the cross-table lateral radiograph. The values for these angles were compared in a group of known dislocating THAs (7 hips) and a control group of stable THAs (90 hips). These radiographic measurements were also assessed for their reproducibility. The values for the abduction and version angles were not significantly different between the two groups. The values for abduction and version angles for a given hip, from one examination to another, were reproducible. Neither the abduction nor the version angle was a predictor of dislocation.


Assuntos
Luxação do Quadril/diagnóstico por imagem , Prótese de Quadril , Complicações Pós-Operatórias/diagnóstico por imagem , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Amplitude de Movimento Articular/fisiologia , Valores de Referência , Estudos Retrospectivos , Fatores de Risco
19.
Clin Orthop Relat Res ; (219): 283-90, 1987 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3581581

RESUMO

Changes in radiostrontium clearance (SrC) and bone formation (tetracycline labeling) were observed in the femurs of skeletally mature dogs following the various operative steps involved in bone screw fixation. Drilling, but not periosteal stripping, produced a small but statistically significant increase in SrC and endosteal bone formation in the distal third of the bone. Strontium clearance values equivalent to those produced by drilling alone were recorded after screw fixation at low or high torque (5 versus 20 inch pounds), as well as by the insertion of loosely fitting stainless steel implants. Bone formation (equals the percentage tetracycline-labeled trabecular bone surfaces) was increased by 30% when SrC values exceeded 3.5 ml/100 g bone/min, and the relationship was linear when SrC values ranged between 1.0 and 7.0 ml/100 g bone/min. The changes in SrC and bone formation one-week after bone screw application are primarily those associated with a response to local trauma caused by drilling.


Assuntos
Parafusos Ósseos , Fêmur/irrigação sanguínea , Osteogênese , Radioisótopos de Estrôncio/metabolismo , Animais , Cães , Fêmur/metabolismo , Fêmur/cirurgia , Tetraciclina
20.
Clin Orthop Relat Res ; (232): 205-9, 1988 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3383489

RESUMO

A 42-year-old alcoholic man who had a normal femoral head histologically incurred a subcapital fracture four months after surgical treatment of an intertrochanteric fracture of the same hip. Subcapital fracture of the hip following intertrochanteric fracture is an unusual occurrence, with possibly as few as 11 cases documented in the literature. Affected persons are usually elderly females with severe osteoporosis. Though unusual, the fracture is obvious and not difficult to treat.


Assuntos
Fraturas do Colo Femoral/cirurgia , Fraturas do Quadril/cirurgia , Prótese de Quadril , Complicações Pós-Operatórias/etiologia , Adulto , Parafusos Ósseos , Fraturas do Colo Femoral/etiologia , Fraturas do Quadril/complicações , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA