Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Diabetologia ; 67(8): 1455-1479, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38907161

RESUMO

The American Diabetes Association (ADA), European Association for the Study of Diabetes (EASD), Joint British Diabetes Societies for Inpatient Care (JBDS), American Association of Clinical Endocrinology (AACE) and Diabetes Technology Society (DTS) convened a panel of internists and diabetologists to update the ADA consensus statement on hyperglycaemic crises in adults with diabetes, published in 2001 and last updated in 2009. The objective of this consensus report is to provide up-to-date knowledge about the epidemiology, pathophysiology, clinical presentation, and recommendations for the diagnosis, treatment and prevention of diabetic ketoacidosis (DKA) and hyperglycaemic hyperosmolar state (HHS) in adults. A systematic examination of publications since 2009 informed new recommendations. The target audience is the full spectrum of diabetes healthcare professionals and individuals with diabetes.


Assuntos
Cetoacidose Diabética , Hiperglicemia , Humanos , Cetoacidose Diabética/terapia , Cetoacidose Diabética/epidemiologia , Adulto , Consenso , Diabetes Mellitus/epidemiologia , Coma Hiperglicêmico Hiperosmolar não Cetótico/terapia
2.
Diabetes Obes Metab ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39382001

RESUMO

AIMS: The aim was to evaluate the effect of extended use of the Omnipod® 5 automated insulin delivery (AID) system in adults with type 2 diabetes and suboptimal glycaemic control. MATERIALS AND METHODS: Following an 8-week single-arm, multicentre, outpatient trial of AID in adults with type 2 diabetes and baseline ≥ 64 mmol/mol, participants were given the opportunity to continue use of the AID system in a 26-week (~6 month) extension phase. The primary safety endpoints were percentage of time with sensor glucose ≥ 250 mg/dL and < 54 mg/dL. Additional glycaemic measures, including percentage of time in range (TIR) (70-180 mg/dL) and HbA1c, were evaluated. The use of non-insulin anti-hyperglycaemic medications was permitted throughout the entire study. RESULTS: During the initial 8-week study, participants (N = 22) achieved a decrease in percentage of time ≥ 250 mg/dL from 27.4% ± 21.0% to 10.5% ± 8.8% (p < 0.0001), which further decreased to 9.7% ± 9.2% during the extension phase (p = 0.0002 vs. standard therapy). Percentage of time < 54 mg/dL remained low from standard therapy through extension (median [interquartile range] 0.00% [0.00%, 0.06%] vs. 0.02% [0.00%, 0.05%], p > 0.05). HbA1c decreased by 1.6% ± 1.2% (15.5 ± 13.1 mmol/mol, p < 0.0001) and TIR increased by 22.4% ± 19.2% (p < 0.0001) from standard therapy through extension with no significant change in body mass index and without an observed increase in total daily insulin requirements. CONCLUSIONS: These longer-term findings of Omnipod 5 AID system use demonstrate the potential value of AID in helping people with type 2 diabetes reach glycaemic targets.

3.
Diabetes Obes Metab ; 24(1): 42-49, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34490700

RESUMO

AIMS: Limited data exist about the use of insulin degludec in the hospital. This multicentre, non-inferiority, open-label, prospective randomized trial compared the safety and efficacy of insulin degludec-U100 and glargine-U100 for the management of hospitalized patients with type 2 diabetes. METHODS: In total, 180 general medical and surgical patients with an admission blood glucose (BG) between 7.8 and 22.2 mmol/L, treated with oral agents or insulin before hospitalization were randomly allocated (1:1) to a basal-bolus regimen using degludec (n = 92) or glargine (n = 88), as basal and aspart before meals. Insulin dose was adjusted daily to a target BG between 3.9 and 10.0 mmol/L. The primary endpoint was the difference in mean hospital daily BG between groups. RESULTS: Overall, the randomization BG was 12.2 ± 2.9 mmol/L and glycated haemoglobin 84 mmol/mol (9.8% ± 2.0%). There were no differences in mean daily BG (10.0 ± 2.1 vs. 10.0 ± 2.5 mmol/L, p = .9), proportion of BG in target range (54·5% ± 29% vs. 55·3% ± 28%, p = .85), basal insulin (29.6 ± 13 vs. 30.4 ± 18 units/day, p = .85), length of stay [median (IQR): 6.7 (4.7-10.5) vs. 7.5 (4.7-11.6) days, p = .61], hospital complications (23% vs. 23%, p = .95) between treatment groups. There were no differences in the proportion of patients with BG <3.9 mmol/L (17% vs. 19%, p = .75) or <3.0 mmol/L (3.7% vs. 1.3%, p = .62) between degludec and glargine. CONCLUSION: Hospital treatment with degludec-U100 or glargine-U100 is equally safe and effective for the management of hyperglycaemia in general medical and surgical patients with type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hospitais , Humanos , Hipoglicemiantes/efeitos adversos , Pacientes Internados , Insulina Glargina/efeitos adversos , Insulina de Ação Prolongada , Estudos Prospectivos
4.
Diabetes Obes Metab ; 23(6): 1351-1360, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33591621

RESUMO

AIM: To compare a glucagon-like peptide-1 receptor agonist with basal insulin at hospital discharge in patients with uncontrolled type 2 diabetes in a randomized clinical trial. METHODS: A total of 273 patients with glycated haemoglobin (HbA1c) 7%-10% (53-86 mol/mol) were randomized to liraglutide (n = 136) or insulin glargine (n = 137) at hospital discharge. The primary endpoint was difference in HbA1c at 12 and 26 weeks. Secondary endpoints included hypoglycaemia, changes in body weight, and achievement of HbA1c <7% (53 mmol/mol) without hypoglycaemia or weight gain. RESULTS: The between-group difference in HbA1c at 12 weeks and 26 weeks was -0.28% (95% CI -0.64, 0.09), and at 26 weeks it was -0.55%, (95% CI -1.01, -0.09) in favour of liraglutide. Liraglutide treatment resulted in a lower frequency of hypoglycaemia <3.9 mmol/L (13% vs 23%; P = 0.04), but there was no difference in the rate of clinically significant hypoglycaemia <3.0 mmol/L. Compared to insulin glargine, liraglutide treatment was associated with greater weight loss at 26 weeks (-4.7 ± 7.7 kg vs -0.6 ± 11.5 kg; P < 0.001), and the proportion of patients with HbA1c <7% (53 mmol/mol) without hypoglycaemia was 48% versus 33% (P = 0.05) at 12 weeks and 45% versus 33% (P = 0.14) at 26 weeks in liraglutide versus insulin glargine. The proportion of patients with HbA1c <7% (53 mmol/mol) without hypoglycaemia and no weight gain was higher with liraglutide at 12 (41% vs 24%, P = 0.005) and 26 weeks (39% vs 22%; P = 0.014). The incidence of gastrointestinal adverse events was higher with liraglutide than with insulin glargine (P < 0.001). CONCLUSION: Compared to insulin glargine, treatment with liraglutide at hospital discharge resulted in better glycaemic control and greater weight loss, but increased gastrointestinal adverse events.


Assuntos
Diabetes Mellitus Tipo 2 , Liraglutida , Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Quimioterapia Combinada , Hemoglobinas Glicadas/análise , Hospitais , Humanos , Hipoglicemiantes/efeitos adversos , Insulina Glargina/efeitos adversos , Liraglutida/efeitos adversos , Alta do Paciente , Resultado do Tratamento
5.
Diabetes Obes Metab ; 23(2): 480-488, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33140566

RESUMO

AIM: To assess whether treatment with sitagliptin, starting before surgery and continued during the hospital stay, can prevent and reduce the severity of perioperative hyperglycaemia in patients with type 2 diabetes undergoing coronary artery bypass graft (CABG) surgery. MATERIALS AND METHODS: We conducted a double-blinded, placebo-controlled trial in adults with type 2 diabetes randomly assigned to receive sitagliptin or matching placebo starting 1 day prior to surgery and continued during the hospital stay. The primary outcome was difference in the proportion of patients with postoperative hyperglycaemia (blood glucose [BG] > 10 mmol/L [>180 mg/dL]) in the intensive care unit (ICU). Secondary endpoints included differences in mean daily BG in the ICU and after transition to regular wards, hypoglycaemia, hospital complications, length of stay and need of insulin therapy. RESULTS: We included 182 participants randomized to receive sitagliptin or placebo (91 per group, age 64 ± 9 years, HbA1c 7.6% ± 1.5% and diabetes duration 10 ± 9 years). There were no differences in the number of patients with postoperative BG greater than 10 mmol/L, mean daily BG in the ICU or after transition to regular wards, hypoglycaemia, hospital complications or length of stay. There were no differences in insulin requirements in the ICU; however, sitagliptin therapy was associated with lower mean daily insulin requirements (21.1 ± 18.4 vs. 32.5 ± 26.3 units, P = .007) after transition to a regular ward compared with placebo. CONCLUSION: The administration of sitagliptin prior to surgery and during the hospital stay did not prevent perioperative hyperglycaemia or complications after CABG. Sitagliptin therapy was associated with lower mean daily insulin requirements after transition to regular wards.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Diabetes Mellitus Tipo 2 , Hiperglicemia , Adulto , Idoso , Glicemia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Pessoa de Meia-Idade , Fosfato de Sitagliptina/uso terapêutico , Resultado do Tratamento
6.
JAMA ; 325(22): 2262-2272, 2021 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-34077499

RESUMO

Importance: Continuous glucose monitoring (CGM) has been shown to be beneficial for adults with type 2 diabetes using intensive insulin therapy, but its use in type 2 diabetes treated with basal insulin without prandial insulin has not been well studied. Objective: To determine the effectiveness of CGM in adults with type 2 diabetes treated with basal insulin without prandial insulin in primary care practices. Design, Setting, and Participants: This randomized clinical trial was conducted at 15 centers in the US (enrollment from July 30, 2018, to October 30, 2019; follow-up completed July 7, 2020) and included adults with type 2 diabetes receiving their diabetes care from a primary care clinician and treated with 1 or 2 daily injections of long- or intermediate-acting basal insulin without prandial insulin, with or without noninsulin glucose-lowering medications. Interventions: Random assignment 2:1 to CGM (n = 116) or traditional blood glucose meter (BGM) monitoring (n = 59). Main Outcomes and Measures: The primary outcome was hemoglobin A1c (HbA1c) level at 8 months. Key secondary outcomes were CGM-measured time in target glucose range of 70 to 180 mg/dL, time with glucose level at greater than 250 mg/dL, and mean glucose level at 8 months. Results: Among 175 randomized participants (mean [SD] age, 57 [9] years; 88 women [50%]; 92 racial/ethnic minority individuals [53%]; mean [SD] baseline HbA1c level, 9.1% [0.9%]), 165 (94%) completed the trial. Mean HbA1c level decreased from 9.1% at baseline to 8.0% at 8 months in the CGM group and from 9.0% to 8.4% in the BGM group (adjusted difference, -0.4% [95% CI, -0.8% to -0.1%]; P = .02). In the CGM group, compared with the BGM group, the mean percentage of CGM-measured time in the target glucose range of 70 to 180 mg/dL was 59% vs 43% (adjusted difference, 15% [95% CI, 8% to 23%]; P < .001), the mean percentage of time at greater than 250 mg/dL was 11% vs 27% (adjusted difference, -16% [95% CI, -21% to -11%]; P < .001), and the means of the mean glucose values were 179 mg/dL vs 206 mg/dL (adjusted difference, -26 mg/dL [95% CI, -41 to -12]; P < .001). Severe hypoglycemic events occurred in 1 participant (1%) in the CGM group and in 1 (2%) in the BGM group. Conclusions and Relevance: Among adults with poorly controlled type 2 diabetes treated with basal insulin without prandial insulin, continuous glucose monitoring, as compared with blood glucose meter monitoring, resulted in significantly lower HbA1c levels at 8 months. Trial Registration: ClinicalTrials.gov Identifier: NCT03566693.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 2/tratamento farmacológico , Controle Glicêmico/métodos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Idoso , Intervalos de Confiança , Diabetes Mellitus Tipo 2/sangue , Feminino , Hemoglobinas Glicadas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Período Pós-Prandial , Tamanho da Amostra , Fatores de Tempo , Resultado do Tratamento
7.
Endocr Pract ; 26(7): 722-728, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33471640

RESUMO

OBJECTIVE: DPP-4 inhibitors (DPP-4i) have been shown to be effective for the management of inpatient diabetes. We report pooled data from 3 prospective studies using DPP-4i in general medicine and surgery patients with type 2 diabetes (T2D). METHODS: We combined data from 3 randomized studies comparing DPP-4i alone or in combination with basal insulin or a basal-bolus insulin regimen. Medicine (n = 266) and surgery (n = 319) patients admitted with a blood glucose (BG) between 140 and 400 mg/dL, treated with diet, oral agents, or low-dose insulin therapy were included. Patients received DPP-4i alone (n = 144), DPP-4i plus basal insulin (n = 158) or basal-bolus regimen (n = 283). All groups received correctional doses with rapid-acting insulin for BG >140 mg/dL. The primary endpoint was differences in mean daily BG between groups. Secondary endpoints included differences in hypoglycemia and hospital complications. RESULTS: There were no differences in mean hospital daily BG among patients treated with DPP-4i alone (170 ± 37 mg/dL), DPP-4i plus basal (172 ± 42 mg/dL), or basalbolus (172 ± 43 mg/dL), P = .94; or in the percentage of BG readings within target of 70 to 180 mg/dL (63 ± 32%, 60 ± 31%, and 64 ± 28%, respectively; P = .42). There were no differences in length of stay or complications, but hypoglycemia was less common with DPP-4i alone (2%) compared to DPP-4i plus basal (9%) and basal-bolus (10%); P = .004. CONCLUSION: Treatment with DPP-4i alone or in combination with basal insulin is effective and results in a lower incidence of hypoglycemia compared to a basal-bolus insulin regimen in general medicine and surgery patients with T2D. ABBREVIATIONS: BG = blood glucose; BMI = body mass index; CI = confidence interval; DPP-4i = dipeptidyl peptidase-4 inhibitors; HbA1c = hemoglobin A1c; OR = odds ratio; T2D = type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Inibidores da Dipeptidil Peptidase IV , Medicina , Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Inibidores da Dipeptidil Peptidase IV/efeitos adversos , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Insulina Glargina , Estudos Prospectivos
8.
JAMA ; 2024 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-39441612

RESUMO

This pooled cross-sectional study explores prescribing rates for glucagon-like peptide-1 receptor agonists and sodium-glucose cotransporter 2 inhibitors among US patients with type 1 diabetes.

9.
Endocr Pract ; 23(9): 1059-1066, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28683239

RESUMO

OBJECTIVE: Glargine and detemir insulin are the two most commonly prescribed basal insulin analogues for the ambulatory and inpatient management of diabetes. The efficacy and safety of basal insulin analogues in the hospital setting has not been established. METHODS: This observational study compared differences in glycemic control and outcomes in non-intensive care unit patients with blood glucose (BG) >140 mg/dL who were treated with glargine or detemir, between January 1, 2012, and September 30, 2015, in two academic centers. RESULTS: Among 6,245 medical and surgical patients with hyperglycemia, 5,749 received one or more doses of glargine, and 496 patients received detemir during the hospital stay. There were no differences in the mean daily BG (glargine, 182 ± 46 mg/dL vs. detemir, 180 ± 44 mg/dL; P = .70). There were no differences in mortality, hospital complications, or re-admissions between groups (all, P>.05). After adjusting for potential confounders, there was no statistically significant difference in hypoglycemia rates between treatment groups. Patients treated with detemir required higher total daily basal insulin doses (0.27 ± 0.16 units/kg/day vs. 0.22 ± 0.15 units/kg/day; P<.001). Glargine-treated patients had statistically longer length of stay; however, this difference may not be clinically relevant (6.8 ± 7.4 days vs. 6.0 ± 6.3 days; P<.001). CONCLUSION: Our study indicates that treatment with glargine and detemir results in similar inpatient glycemic control in general medicine and surgery patients. Detemir treatment was associated with higher daily basal insulin dose and number of injections. A prospective randomized study is needed to confirm these findings. ABBREVIATIONS: BG = blood glucose BMI = body mass index CI = confidence interval eGFR = estimated glomerular filtration rate HbA1c = glycated hemoglobin ICD-9 = International Classification of Diseases, ninth revision ICU = intensive care unit IQR = interquartile range LOS = length-of-stay OR = odd ratio.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina Detemir/uso terapêutico , Insulina Glargina/uso terapêutico , Idoso , Glicemia/análise , Diabetes Mellitus/sangue , Feminino , Humanos , Hiperglicemia/sangue , Pacientes Internados , Tempo de Internação , Masculino , Pessoa de Meia-Idade
11.
Diabetes Care ; 47(8): 1257-1275, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39052901

RESUMO

The American Diabetes Association (ADA), European Association for the Study of Diabetes (EASD), Joint British Diabetes Societies for Inpatient Care (JBDS), American Association of Clinical Endocrinology (AACE), and Diabetes Technology Society (DTS) convened a panel of internists and diabetologists to update the ADA consensus statement on hyperglycemic crises in adults with diabetes, published in 2001 and last updated in 2009. The objective of this consensus report is to provide up-to-date knowledge about the epidemiology, pathophysiology, clinical presentation, and recommendations for the diagnosis, treatment, and prevention of diabetic ketoacidosis (DKA) and hyperglycemic hyperosmolar state (HHS) in adults. A systematic examination of publications since 2009 informed new recommendations. The target audience is the full spectrum of diabetes health care professionals and individuals with diabetes.


Assuntos
Cetoacidose Diabética , Humanos , Cetoacidose Diabética/epidemiologia , Cetoacidose Diabética/terapia , Adulto , Hiperglicemia/complicações , Hiperglicemia/epidemiologia , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/fisiopatologia , Consenso , Coma Hiperglicêmico Hiperosmolar não Cetótico/terapia , Coma Hiperglicêmico Hiperosmolar não Cetótico/fisiopatologia
12.
J Strength Cond Res ; 27(8): 2277-81, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23880656

RESUMO

The study examined handgrip strength in participants diagnosed with an autism spectrum disorder (ASD) as compared with neurotypical children. Thirty-three children, aged 2-17 years, with an ASD and 33 gender-, race-, and age-matched neurotypical controls were tested using a handgrip dynamometer. The handgrip strength in participants with an ASD was significantly (p < 0.0001) lower than the neurotypical controls. The mean handgrip strength was 39.4 ± 17.7 kPa in children with ASD and 65.1 ± 26.7 kPa in controls. The results support the hypothesis that children with an ASD have significantly poorer handgrip strength as compared with neurotypical children. Because the handheld dynamometer has been shown to be a valid tool for measuring overall muscle strength, the results suggest that children with ASD have muscle weakness. Future studies are needed to determine the extent of muscle weakness in ASD, its ramifications, and the possible benefits of muscle strengthening. The present study provides support for the use of handgrip strength as a tool for the assessment of targeted treatment in ASD.


Assuntos
Transtornos Globais do Desenvolvimento Infantil/fisiopatologia , Força da Mão/fisiologia , Adolescente , Estudos de Casos e Controles , Criança , Transtornos Globais do Desenvolvimento Infantil/complicações , Pré-Escolar , Feminino , Humanos , Masculino , Dinamômetro de Força Muscular , Debilidade Muscular/complicações , Aptidão Física
13.
J Diabetes Sci Technol ; 17(3): 667-678, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37081830

RESUMO

Traditionally, the care of critically ill patients with diabetes or stress hyperglycemia in the intensive care unit (ICU) demands the use of continuous intravenous insulin (CII) therapy to achieve narrow glycemic targets. To reduce the risk of iatrogenic hypoglycemia and to achieve glycemic targets during CII, healthcare providers (HCP) rely on hourly point-of-care (POC) arterial or capillary glucose tests obtained with glucose monitors. The burden of this approach, however, was evident during the beginning of the pandemic when the immediate reduction in close contact interactions between HCP and patients with COVID-19 was necessary to avoid potentially life-threatening exposures. Taking advantage of the advancements in current diabetes technologies, including continuous glucose monitoring (CGM) devices integrated with digital health tools for remote monitoring, HCP implemented novel protocols in the ICU to care for patients with COVID-19 and hyperglycemia. We provide an overview of research conducted in the ICU setting with the use of initial CGM technology to current devices and summarize our recent experience in the ICU.


Assuntos
COVID-19 , Diabetes Mellitus , Hiperglicemia , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Insulina , Unidades de Terapia Intensiva , Insulina Regular Humana
14.
Diabetes Care ; 46(4): 742-750, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36787903

RESUMO

OBJECTIVE: Automated insulin delivery (AID) has rarely been studied in adults with type 2 diabetes. We tested the feasibility of using AID for type 2 diabetes with the Omnipod 5 System in a multicenter outpatient trial. RESEARCH DESIGN AND METHODS: Participants previously were using either basal-only or basal-bolus insulin injections, with or without the use of a continuous glucose monitor (CGM), and had a baseline HbA1c ≥8% (≥64 mmol/mol). Participants completed 2 weeks of CGM sensor data collection (blinded for those not previously using CGM) with their standard therapy (ST), then transitioned to 8 weeks of AID. Participants who previously used basal-only injections used the AID system in manual mode for 2 weeks before starting AID. Antihyperglycemic agents were continued at clinician discretion. Primary safety outcomes were percentage of time with sensor glucose ≥250 mg/dL and <54 mg/dL during AID. Additional outcomes included HbA1c and time in target range (TIR) (70-180 mg/dL). RESULTS: Participants (N = 24) had a mean (± SD) age of 61 ± 8 years, baseline HbA1c of 9.4% ± 0.9% (79 ± 10 mmol/mol), and diabetes duration of 19 ± 9 years. Percentage of time with sensor glucose ≥250 mg/dL decreased with AID by 16.9% ± 16.2% (P < 0.0001), whereas percentage of time at <54 mg/dL remained low during both ST and AID (median [interquartile range] 0.0% [0.00%, 0.06%] vs. 0.00% [0.00%, 0.03%]; P = 0.4543). HbA1c (± SD) decreased by 1.3% ± 0.7% (14 ± 8 mmol/mol; P < 0.0001) and TIR increased by 21.9% ± 15.2% (P < 0.0001) without a significant change in total daily insulin or BMI with AID. CONCLUSIONS: Findings from this feasibility trial of AID in adults with type 2 diabetes with suboptimal glycemic outcomes justify further evaluation of this technology in this population.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas , Automonitorização da Glicemia , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Glicemia , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina
15.
J Diabetes Sci Technol ; 17(1): 201-207, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34293955

RESUMO

BACKGROUND: We studied a smart insulin pen cap that can be plugged to several brand of insulin pens, to track insulin administration via smart-phone Bluetooth technology, with alarm/reminder system aiming. METHODS: This pilot randomized, cross-over design study assessed the use of a smart insulin pen cap in improving adherence, glycemic control and patient satisfaction in insulin-treated patients with poorly controlled type 2 diabetes. Eighty patients on basal insulin ± oral agents with hemoglobin A1C (HbA1c) between 7.0% and 12.0% were randomized to a 12-week active phase receiving alarms/reminders and a 12-week control/masked phase without feedback. We assessed differences between groups on treatment adherence, insulin omission, and mistiming of insulin injections, HbA1c, treatment satisfaction (using Diabetes Treatment Satisfaction Questionnaire Status). RESULTS: Compared to the control/masked phase, the active phase resulted in lower mean daily blood glucose (147.0 ± 34 vs 157.6 ± 42 mg/dL, P < .01); and greater reduction in HbA1c from baseline (-0.98% vs -0.72%, P = .006); however, no significant differences in treatment adherence, insulin omission or insulin mistiming were observed. High patient satisfaction scores were reported in both active and control phases, with DTSQc of 15.5 ± 3.7 and 14.9 ± 3.6, respectively. Statistical models showed no residual effect after cross-over between active and control phases. CONCLUSIONS: The results of this pilot study indicates that this smart insulin pen cap was effective in improving glycemic control with overall good satisfaction in insulin treated patients with type 2 diabetes. Future studies are needed to confirm its potential for improving care in insulin treated patients with diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes , Estudos Cross-Over , Hemoglobinas Glicadas , Projetos Piloto , Insulina , Glicemia , Insulina Regular Humana
16.
Diabetes Technol Ther ; 25(11): 765-773, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37768677

RESUMO

Objective: Previous studies revealed that hemoglobin A1c (HbA1c) increased overall in the United States in the past decade. In addition, health inequities in type 1 diabetes (T1D) outcomes by race/ethnicity and insurance type persist. This study examines the trends in HbA1c from 2016 to 2022 stratified by race/ethnicity and insurance in a large multicenter national database. Research Design and Methods: We analyzed glycemic outcomes and diabetes device use trends for >48,000 people living with type 1 diabetes (PwT1D) from 3 adult and 12 pediatric centers in the T1D Exchange Quality Improvement Collaborative (T1DX-QI), comparing data from 2016 to 2017 with data from 2021 to 2022. Results: The mean HbA1c in 2021-2022 was lower at 8.4% compared with the mean HbA1c in 2016-2017 of 8.7% (0.3% improvement; P < 0.01). Over the same period, the percentage of PwT1D using a continuous glucose monitor (CGM), insulin pump, or hybrid closed-loop system increased (45%, 12%, and 33%, respectively). However, these improvements were not equitably demonstrated across racial/ethnic groups or insurance types. Racial/ethnic and insurance-based inequities persisted over all 7 years across all outcomes; comparing non-Hispanic White and non-Hispanic Black PwT1D, disparate gaps in HbA1c (1.2%-1.6%), CGM (30%), pump (25%-35%), and hybrid-closed loop system (up to 20%) are illuminated. Conclusion: Population-level data on outcomes, including HbA1c, can provide trends and insights into strategies to improve health for PwT1D. The T1DX-QI cohort showed a significant improvement in HbA1c from 2016 to 2022. Improvements in diabetes device use are also demonstrated. However, these increases were inconsistent across all racial/ethnic groups or insurance types, an important focus for future T1D population health improvement work.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Criança , Humanos , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas , Melhoria de Qualidade , Estados Unidos/epidemiologia , Estudos Multicêntricos como Assunto
17.
Diabetes Care ; 46(9): 1640-1645, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37459574

RESUMO

OBJECTIVE: In participants with type 2 diabetes (T2D) and HbA1c >9.0-10.0%, guidelines recommend treatment with basal-bolus insulin. RESEARCH DESIGN AND METHODS: This randomized trial compared the efficacy and safety of insulin degludec and liraglutide (IDegLira) and basal-bolus among participants with high HbA1c ≥9.0-15.0%, previously treated with 2 or 3 oral agents and/or basal insulin, allocated (1:1) to basal-bolus (n = 73) or IDegLira (n = 72). The primary end point was noninferiority (0.4%) in HbA1c reduction between groups. RESULTS: Among 145 participants (HbA1c 10.8% ± 1.3), there was no statistically significant difference in HbA1c reduction (3.18% ± 2.29 vs. 3.00% ± 1.79, P = 0.65; estimated treatment difference (ETD) 0.18%, 95% CI -0.59, 0.94) between the IDegLira and basal-bolus groups. IDegLira resulted in significantly lower rates of hypoglycemia <70 mg/dL (26% vs. 48%, P = 0.008; odds ratio 0.39, 95% CI 0.19, 0.78), and less weight gain (1.24 ± 8.33 vs. 5.84 ± 6.18 kg, P = 0.001; ETD -4.60, 95% CI -7.33, -1.87). CONCLUSIONS: In participants with T2D and HbA1c ≥9.0-15.0%, IDegLira resulted in similar HbA1c reduction, less hypoglycemia, and less weight gain compared with the basal-bolus regimen.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Humanos , Liraglutida/efeitos adversos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Hemoglobinas Glicadas , Glicemia , Insulina de Ação Prolongada , Combinação de Medicamentos , Aumento de Peso
18.
J Diabetes Sci Technol ; 17(5): 1284-1294, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37449365

RESUMO

BACKGROUND: The magnitude of the response of the diabetes professional community to the COVID-19 pandemic is not known. We aimed to examine diabetes technology research trends and resources offered by professional organizations during this period. METHODS: We explored patterns of the response from the professional diabetes community to the pandemic by (1) systematically searching for articles related to diabetes, COVID-19, and diabetes technologies; (2) examining publication trends of research protocols (clinicaltrials.gov) and preprints (medRxiv); and (3) reviewing online resources from professional organizations including our website (COVIDinDiabetes.org; an Emory University-Diabetes Technology Society collaboration). RESULTS: We identified 492 articles published between December 2019 and December 2022 meeting our inclusion criteria. Telemedicine and continuous glucose monitoring were the most common reported technologies from most parts of the world. The largest number of preprint articles was published in 2020, with a decline in 2021 and 2022. The number of research protocols related to COVID-19 was the highest in 2020 and declined in 2021 and 2022. Resources from organizations included protocols adapted to treat patients with diabetes and COVID-19, training programs, emergency preparedness, and literature on diabetes and COVID-19. On our website (COVIDinDiabetes.org), there were 12 236 visits and 18 149 pageviews, with 1.6 actions per visits, with most visits coming from North America (N = 7233, 54.2%), South America (N = 2663, 21.8%), and Europe (N = 1219). CONCLUSIONS: We conclude that the COVID-19 pandemic promoted unprecedented global research productivity related to diabetes and COVID-19 and that the transition to the use of technology resources has been evident during this period.


Assuntos
COVID-19 , Diabetes Mellitus , Telemedicina , Humanos , COVID-19/epidemiologia , Pandemias , Automonitorização da Glicemia/métodos , Glicemia , Telemedicina/métodos , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/terapia
19.
Diabetes Technol Ther ; 25(10): 677-688, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37578778

RESUMO

Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Hipoglicemia , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Viabilidade , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Projetos Piloto
20.
J Diabetes Sci Technol ; 17(6): 1527-1552, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37592726

RESUMO

Diabetes Technology Society organized an expert consensus panel to develop metrics for research in the use of continuous glucose monitors (CGMs) in a hospital setting. The experts met virtually in small groups both before and after an April 13, 2023 virtual meeting of the entire panel. The goal of the panel was to develop consensus definitions in anticipation of greater use of CGMs in hospital settings in the future. Establishment of consensus definitions of inpatient analytical metrics will be easier to compare outcomes between studies. Panelists defined terms related to 10 dimensions of measurements related to the use of CGMs including (1) hospital hypoglycemia, (2) hospital hyperglycemia, (3) hospital time in range, (4) hospital glycemic variability, (5) hospital glycemia risk index, (6) accuracy of CGM devices and reference methods for CGMs in the hospital, (7) meaningful time blocks for hospital glycemic goals, (8) hospital CGM data sufficiency, (9) using CGM data for insulin dosing, and (10) miscellaneous factors. The panelists voted on 51 proposed recommendations. Based on the panel vote, 51 recommendations were classified as either strong (43) or mild (8). Additional research is needed on CGM performance in the hospital. This consensus report is intended to support that type of research intended to improve outcomes for hospitalized people with diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus , Hipoglicemia , Humanos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/tratamento farmacológico , Pacientes Internados , Ensaios Clínicos como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA