Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Paediatr Dent ; 26(1): 13-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25614929

RESUMO

BACKGROUND: Although smooth-surface caries can be subjectively assessed by visual inspection, quantitative methods would improve the monitoring of these lesions. AIM: To evaluate the in vitro performance of laser fluorescence devices, namely DIAGNOdent (LF) and DIAGNOdent pen (LFpen), and a fluorescence camera (VistaProof; FC) in the detection and quantification of smooth-surface caries in primary teeth. DESIGN: Two examiners evaluated 99 smooth surfaces of 65 extracted primary molars using FC, LF, and LFpen. As a reference standard, the actual and relative lesion depths were determined using stereomicroscopy and polarized light microscopy. Reproducibilities were assessed, and correlation analyses were performed. The sensitivities, specificities, and accuracies of the methods were calculated and compared. RESULTS: There was a significant correlation between the values obtained using the fluorescence-based devices and the actual and relative lesion depths, although the correlation coefficient values were not higher than 0.7 (LF, 0.673; LFpen, 0.646; FC, 0.663). The sensitivities of the devices were similar for the detection of enamel caries, although LFpen was superior in detecting dentin lesions. The reliabilities of all methods were moderate to low, with similar accuracies at all depths. CONCLUSION: Although the fluorescence-based devices showed similar performance in the detection of enamel and dentin lesions, the reliability of these devices and the correlation of their findings with the actual and relative lesion depths were moderate with regard to smooth-surface caries in primary molars.


Assuntos
Cárie Dentária/diagnóstico , Cárie Dentária/patologia , Fluorescência , Humanos , Técnicas In Vitro , Dente Molar/patologia , Sensibilidade e Especificidade , Dente Decíduo/patologia
2.
Lasers Med Sci ; 28(1): 185-92, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22569685

RESUMO

The aim of this in vitro study was to determine the influence of cross-infection control methods, as probe tip autoclaving and polyvinyl chloride (PVC) wrapping, on the performance of laser fluorescence device (DIAGNOdent pen--LFpen) on occlusal surfaces of primary molars. One experienced examiner carried out all examinations (n = 78). For the probe tip autoclaving study, 62 sites (sample A, 40 teeth) were used. The sites were assessed with LFpen using tips in six different conditions: without autoclaving and after autoclaving for 10, 20, 30, 40, and 50 cycles of 10 min. For the PVC wrapping study, we selected other 58 sites (sample B, 38 teeth). The sites were assessed with the LFpen device in two conditions: with and without PVC wrapping. The teeth were sectioned and histologically assessed for caries depth. LFpen values, sensitivity, and specificity were compared among the different conditions. The LF readings were slightly higher after successive examinations, independently of autoclaving. In both studies, no statistical differences in the sensitivity and specificity were observed for all conditions. In conclusion, probe tip autoclaving and PVC wrapping do not influence the performance of LFpen device on occlusal surfaces of primary molars.


Assuntos
Infecção Hospitalar/prevenção & controle , Cárie Dentária/diagnóstico , Lasers , Esterilização/métodos , Dente Decíduo/patologia , Cárie Dentária/patologia , Fluorescência , Humanos , Técnicas In Vitro , Dente Molar , Fotografia Dentária , Cloreto de Polivinila , Sensibilidade e Especificidade
3.
Lasers Med Sci ; 26(2): 157-62, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20157753

RESUMO

The aims of this in vitro study were (1) to compare the reliability of a new fluorescence camera (FC; VistaProof) with that of two other laser fluorescence devices (DIAGNOdent and DIAGNOdent pen) in assessing smooth and occlusal caries lesions in primary teeth and (2) to determine the influence of the spacer, the protective cover and air drying on the FC readings. We selected 129 primary molars which were divided into two groups: smooth surfaces (n=68) and occlusal surfaces (n=61). Two trained examiners performed the evaluations using the FC and the other laser fluorescence devices separately. One examiner repeated all assessments after 1 week. Inter- and intraexaminer reproducibility was calculated from the absolute values derived from the devices using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Pearson correlation was performed among the values obtained with the different devices. For aim 2, only teeth from the occlusal surface group were used. Another examiner performed measurements with the FC, varying the size of the spacer, the use of the plastic protective cover and the drying time (0, 3 and 15 s). Wilcoxon's test was used to compare these measurements. High values of interexaminer ICC were observed with the FC in both experiments. However, the highest intraexaminer ICC for smooth surfaces was found for the DIAGNOdent (ICC 0.918). A positive correlation between all methods was observed in both studies. Only drying for 15 s significantly increased the FC readings. In conclusion, the FC showed high reliability for occlusal and smooth surfaces, similar to the other fluorescence methods tested. Additionally, prolonged air drying increased the FC measurements.


Assuntos
Cárie Dentária/diagnóstico , Dente Decíduo , Fluorescência , Humanos , Lasers , Dente Molar , Fotografia Dentária , Reprodutibilidade dos Testes
4.
Quintessence Int ; 35(9): 689-92, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15470991

RESUMO

A case report describing a technique for the restoration of endodontically treated primary maxillary incisors with resin composite short posts and celluloid strip crowns in a 3-year-old boy is presented. The technique offers the advantages of using one restorative material, improving esthetics, and reducing chairtime and costs.


Assuntos
Resinas Compostas , Coroas , Técnica para Retentor Intrarradicular , Dente Decíduo , Pré-Escolar , Humanos , Incisivo , Masculino , Maxila , Pulpectomia
5.
J Biomed Opt ; 15(4): 047005, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20799836

RESUMO

An in vivo study was conducted to verify the ability of laser fluorescence (LF) to assess the activity status of occlusal caries in primary teeth, using different air-drying times. Occlusal sites (707) were examined using LF (DIAGNOdent) after air-drying for 3 s and 15 s, and the difference between readings (DIF15 s-3 s) was calculated. For concurrent validation of LF, visual criteria-Nyvad (NY) and Lesion Activity Assessment associated with the International Caries Detection and Assessment System (LAA-ICDAS)-were the reference standards for lesion activity. Histological exam using a pH-indicator dye (0.1% methyl red) was performed in 46 exfoliated/extracted teeth for criterion validation. LF readings and DIF15 s-3 s were compared using Kruskall-Wallis and Mann-Whitney tests. Receiver operating characteristic analyses were performed and validity parameters calculated, considering the caries activity assessment. Using NY, active lesions (3 s: 30.0+/-29.3; 15 s: 34.2+/-30.6) presented higher LF readings than inactive lesions (3 s: 17.0+/-16.3; 15 s: 19.2+/-17.3; p<0.05), different from LAA-ICDAS. Active cavitated caries resulted in higher LF readings (3 s: 50.3+/-3.5; 15 s: 54.7+/-30.2) than inactive cavitated caries (3 s: 19.9+/-16.3; 15 s: 22.8+/-16.8). Therefore, LF can distinguish cavitated active and inactive lesions classified by NY, but not by LAA-ICDAS; however, this difference might be related to the visual system rather than to LF. The air-drying time could be an alternative to improve the caries activity assessment; however, longer air-drying time is suggested to be tested subsequently.


Assuntos
Testes de Atividade de Cárie Dentária/métodos , Cárie Dentária/classificação , Cárie Dentária/patologia , Lasers , Iluminação/instrumentação , Espectrometria de Fluorescência/instrumentação , Dente Decíduo , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA