1.
Clin Chem ; 67(5): 763-771, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33585916

RESUMO

BACKGROUND: Immunoassays for protein analytes measured in situ support a $2 billion laboratory testing industry that suffers from significant interlaboratory disparities, affecting patient treatment. The root cause is that immunohistochemical testing lacks the generally accepted tools for analytic standardization, including reference standards and traceable units of measure. Until now, the creation of these tools has represented an insoluble technical hurdle. METHODS: We address the need with a new concept in metrology-that is, linked traceability. Rather than calculating analyte concentration directly, which has proven too variable, we calculate concentration by measuring an attached fluorescein, traceable to NIST Standard Reference Material 1934, a fluorescein standard. RESULTS: For validation, newly developed estrogen receptor (ER) calibrators were deployed in tandem with an array of 80 breast cancer tissue sections in a national external quality assessment program. Laboratory performance was assessed using both the ER standards and the tissue array. Similar to previous studies, the tissue array revealed substantial discrepancies in ER test results among the participating laboratories. The new ER calibrators revealed a broad range of analytic sensitivity, with the lower limits of detection ranging from 7310 to 74 790 molecules of ER. The data demonstrate, for the first time, that the variable test results correlate with analytic sensitivity, which can now be measured quantitatively. CONCLUSIONS: The reference standard enables precise interlaboratory alignment of immunohistochemistry test sensitivity for measuring cellular proteins in situ. The introduction of a reference standard and traceable units of measure for protein expression marks an important milestone.


Assuntos
Receptores de Estrogênio , Fluoresceínas , Humanos , Imunoensaio , Imuno-Histoquímica , Padrões de Referência
2.
Int J Mol Sci ; 21(17)2020 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-32846978

RESUMO

A stochastic reaction-diffusion model was developed to describe the binding of labeled monoclonal antibodies (mAbs) to CD4 receptors on the surface of T cells. The mAbs diffused to, adsorbed on, and underwent monovalent and bivalent binding to CD4 receptors on the cell surface. The model predicted the time-dependent nature of all populations involved in the labeling process. At large time, the populations reached equilibrium values, giving the number of antibodies bound to the T cell (ABC) defined as the sum of monovalently and bivalently bound mAbs. The predicted coefficient of variation (CV%) of the (ABC) values translated directly to a corresponding CV% of the measured mean fluorescence intensity (MFI). The predicted CV% was about 0.2% from the intrinsic fluctuations of the stochastic reaction process, about 5% after inclusion of the known fluctuations in the number of available CD4 receptors, and about 11% when fluctuations in bivalent binding affinity were included. The fluorescence detection process is expected to contribute approximately 7%. The abovementioned contributions to CV% sum up to approximately 13%. Work is underway to reconcile the predicted values and the measured values of 17% to 22%.


Assuntos
Anticorpos Monoclonais/metabolismo , Antígenos CD4/metabolismo , Modelos Teóricos , Linfócitos T/metabolismo , Afinidade de Anticorpos , Células Cultivadas , Difusão , Humanos , Ligação Proteica , Processos Estocásticos , Especificidade por Substrato
3.
Artigo em Inglês | MEDLINE | ID: mdl-34877136

RESUMO

Accurate number concentrations of particles in liquid media are needed to assess the quality of water, pharmaceuticals, and other liquids, yet there are limited reference materials or calibration services available with clear traceability to the International System of Units. We describe two methods, based on very simple modifications of commercial particle counter instruments, that can provide traceable number concentration measurements. One method used a light obscuration counter. Fitting a model to the data enabled correction for timing and coincidence errors, and gravimetric calibration of the syringe pump gave a traceable determination of measured volume. Other potential biases were diagnosed by analysis of the particle size distribution. The other method used a dynamic imaging particle counter (a flow imaging microscope). The instrument was intentionally configured so that each particle passing through the flow cell was imaged multiple times. Following the particle image acquisition runs, runs with a rinse solution released and counted microspheres adsorbed to tubing or flow-cell walls. Software assembled the redundant particle images into tracks, and the total number of tracks was assigned as the number of particles counted. Both light obscuration and dynamic imaging methods, when applied to polystyrene microspheres of approximately 4 µm diameter, achieved expanded uncertainties (k = 2) of approximately 2 % of number concentration and agreed to within a difference of 1.1 %.

4.
Artigo em Inglês | MEDLINE | ID: mdl-34877142

RESUMO

The CD4 glycoprotein is a component of the T cell receptor complex which plays an important role in the human immune response. This manuscript describes the measurement and modeling of the binding of fluorescently labeled anti-human CD4 monoclonal antibodies (mAb; SK3 clone) to CD4 receptors on the surface of human peripheral blood mononuclear cells (PBMC). CD4 mAb fluorescein isothiocyanate (FITC) and CD4 mAb allophycoerythrin (APC) conjugates were obtained from commercial sources. Four binding conditions were performed, each with the same PBMC sample and different CD4 mAb conjugate. Each binding condition consisted of the PBMC sample incubated for 30 min in labeling solutions containing progressively larger concentrations of the CD4 mAb-label conjugate. After the incubation period, the cells were re-suspended in PBS-based buffer and analyzed using a flow cytometer to measure the mean fluorescence intensity (MFI) of the labeled cell populations. A model was developed to estimate the equilibrium concentration of bound CD4 mAb-label conjugates to CD4 receptors on PBMC. A set of parameters was obtained from the best fit of the model to the measured MFI data and the known number of CD4 receptors on PBMC surface. Divalent and monovalent binding had to be invoked for the APC and FITC CD4 mAb conjugates, respectively. This suggests that the mAb binding depends on the size of the label, which has significant implications for quantitative flow cytometry. The study supports the National Institute of Standards and Technology program to develop quantitative flow cytometry measurements.

5.
Cytometry A ; 85(11): 978-85, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25132217

RESUMO

Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc.


Assuntos
Benchmarking , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Automação , Calibragem , Citometria de Fluxo
6.
Anal Chem ; 84(9): 3889-98, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22376085

RESUMO

The development of fluorescence applications in the life and material sciences has proceeded largely without sufficient concern for the measurement uncertainties related to the characterization of fluorescence instruments. In this first part of a two-part series on the state-of-the-art comparability of corrected emission spectra, four National Metrology Institutes active in high-precision steady-state fluorometry performed a first comparison of fluorescence measurement capabilities by evaluating physical transfer standard (PTS)-based and reference material (RM)-based calibration methods. To identify achievable comparability and sources of error in instrument calibration, the emission spectra of three test dyes in the wavelength region from 300 to 770 nm were corrected and compared using both calibration methods. The results, obtained for typical spectrofluorometric (0°/90° transmitting) and colorimetric (45°/0° front-face) measurement geometries, demonstrated a comparability of corrected emission spectra within a relative standard uncertainty of 4.2% for PTS- and 2.4% for RM-based spectral correction when measurements and calibrations were performed under identical conditions. Moreover, the emission spectra of RMs F001 to F005, certified by BAM, Federal Institute for Materials Research and Testing, were confirmed. These RMs were subsequently used for the assessment of the comparability of RM-based corrected emission spectra of field laboratories using common commercial spectrofluorometers and routine measurement conditions in part 2 of this series (subsequent paper in this issue).

7.
Anal Chem ; 84(9): 3899-907, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22376144

RESUMO

In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.

8.
Nanomaterials (Basel) ; 12(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36144906

RESUMO

The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.

9.
Anal Chem ; 82(5): 2129-33, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20136134

RESUMO

Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.


Assuntos
Espectrometria de Fluorescência/normas , Calibragem , Limite de Detecção , Reprodutibilidade dos Testes
10.
Nanomedicine (Lond) ; 15(22): 2149-2170, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32885720

RESUMO

Extracellular vesicles (EVs), such as exosomes and microvesicles, are nonreplicating lipid bilayer particles shed by most cell types which have the potential to revolutionize the development and efficient delivery of clinical therapeutics. This article provides an introduction to the landscape of EV-based vectors under development for the delivery of protein- and nucleic acid-based therapeutics. We highlight some of the most pressing measurement and standardization challenges that limit the translation of EVs to the clinic. Current challenges limiting development of EVs for drug delivery are the lack of: standardized cell-based platforms for the production of EV-based therapeutics; EV reference materials that allow researchers/manufacturers to validate EV measurements and standardized measurement systems for determining the molecular composition of EVs.


Assuntos
Exossomos , Vesículas Extracelulares , Ácidos Nucleicos , Sistemas de Liberação de Medicamentos , Padrões de Referência
11.
Rev Sci Instrum ; 78(3): 033107, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17411178

RESUMO

New analytical methods using fluorescence detection are becoming increasingly quantitative and require easy-to-use material standards for fluorometer qualification and method validation. NIST is responding to this need by developing and producing such standards. Reported here is the first step in this process, which is to qualify a research-grade fluorescence spectrometer for measuring true fluorescence spectra of reference material candidates. "True" spectra are defined here as those with fluorescence intensity, either relative or absolute as required, and wavelength both being reported with high accuracy and known precision, after wavelength has been calibrated and corrections for excitation intensity and detection system response have been applied. The uncertainties determined in relative and absolute intensity-corrected fluorescence spectra using both calibrated source (CS)- and calibrated detector (CD)-based methods were compared. The CS-based method gave uncertainties, typically about +/-5% for relative spectral correction, that were about half that of the CD-based method for determining both relative and absolute spectral correction factors. Absolute spectral correction factors can be determined using either method without knowing the optical geometry of the instrument. The absolute spectral correction factors were found to have much larger uncertainties than the corresponding relative correction factors with uncertainties for the CS-based method of +/-10% to +/-15% being typical and +/-20% or more not being uncommon, particularly for excitation and emission wavelengths below 400 nm. Uncertainties arising from detection system nonlinearity and instrument polarization ratios were also explored.


Assuntos
Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/normas , Fluorescência
12.
Appl Spectrosc ; 60(7): 791-9, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16854268

RESUMO

The influence of different data collection procedures and of wavelength-dependent instrumental biases on fluorescence excitation-emission matrix (EEM) spectral analysis of aqueous organic matter samples was investigated. Particular attention was given to fluorescence contours (spectral shape) and peak fluorescence intensities. Instrumental bias was evaluated by independently applying excitation and emission correction factors to the raw excitation and emission data, respectively. The peak fluorescence intensities of representative natural organic matter and tryptophan were significantly influenced by the application of excitation and emission spectral correction factors and by the manner in which the raw data was collected. Humification and fluorescence indices were also influenced by emission correction factors but were independent of reference (excitation) intensity normalization or correction. EEM surface contours were dependent on normalization of the fluorescence intensity to the reference intensity but were not influenced by either excitation or emission spectral correction factors. Authors should be explicit in how excitation and emission spectral correction procedures are implemented in their investigations, which will help to facilitate intra-laboratory comparisons and data sharing.


Assuntos
Monitoramento Ambiental/instrumentação , Poluentes Ambientais/química , Espectrometria de Fluorescência/métodos , Água/química , Meio Ambiente , Modelos Teóricos , Triptofano/química
13.
PLoS One ; 8(9): e73701, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24019934

RESUMO

In this proof-of-concept study, we describe the use of the main red beet pigment betanin for the quantification of calcium dipicolinate in bacterial spores, including Bacillus anthracis. In the presence of europium(III) ions, betanin is converted to a water-soluble, non-luminescent orange 1∶1 complex with a stability constant of 1.4 × 10(5) L mol(-1). The addition of calcium dipicolinate, largely found in bacterial spores, changes the color of the aqueous solution of [Eu(Bn)(+)] from orange to magenta. The limit of detection (LOD) of calcium dipicolinate is around 2.0 × 10(-6) mol L(-1) and the LOD determined for both spores, B. cereus and B. anthracis, is (1.1 ± 0.3)× 10(6) spores mL(-1). This simple, green, fast and low cost colorimetric assay was selective for calcium dipicolinate when compared to several analogous compounds. The importance of this work relies on the potential use of betalains, raw natural pigments, as colorimetric sensors for biological applications.


Assuntos
Bacillus anthracis/fisiologia , Beta vulgaris/química , Colorimetria/instrumentação , Ácidos Picolínicos/análise , Raízes de Plantas/química , Esporos Bacterianos/química , Limite de Detecção
14.
Environ Sci Technol ; 39(17): 6453-60, 2005 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16190199

RESUMO

Surface water samples obtained from the Bull Run tributary upstream and downstream of the Upper Occoquan Sewage Authority(UOSA) advanced wastewater reclamation facility (WRF) were characterized by fluorescence excitation-emission matrix (EEM) spectroscopy, and sorption coefficients (Kmoc) of macromolecular organic carbon isolates were quantified by fluorescence quenching. The EEM data revealed a signature fluorescence distribution in the downstream samples that was attributed to the presence of proteinlike material. The Kmoc values for upstream samples were consistently and significantly higher than those of corresponding downstream samples. There was a moderate correlation (R2 = 0.67) between log Kmoc and the molar extinction coefficient at 280 nm (E280) and a strong correlation (R2 = 0.96) between Kmoc and the proteinlike fluorescence region for macromolecular isolates with negligible quantum yields. This study demonstrates that organic matter downstream of the UOSA-WRF has unique fluorescence and perylene sorption characteristics compared to those of upstream organic matter during summer baseflow conditions. This implies that wastewater treatment facilities, including those advanced facilities designed to reclaim wastewater for indirect potable reuse, can influence the composition and behavior of organic matter in a receiving stream.


Assuntos
Compostos Orgânicos/análise , Perileno/química , Esgotos/química , Poluentes Químicos da Água/análise , Abastecimento de Água , Adsorção , Monitoramento Ambiental , Fluorescência , Rios/química , Espectrometria de Fluorescência