1.
J Clin Monit Comput ; 37(6): 1441-1449, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37266710

RESUMO

Anemia and hypoxemia are common clinical conditions that are difficult to study and may impact pulse oximeter performance. Utilizing an in vitro circulation system, we studied performance of three pulse oximeters during hypoxemia and severe anemia. Three oximeters including one benchtop, one handheld, and one fingertip device were selected to reflect a range of cost and device types. Human blood was diluted to generate four hematocrit levels (40%, 30%, 20%, and 10%). Oxygen and nitrogen were bubbled through the blood to generate a range of oxygen saturations (O2Hb) and the blood was cycled through the in vitro circulation system. Pulse oximeter saturations (SpO2) were paired with simultaneously-measured O2Hb readings from a reference CO-oximeter. Data for each hematocrit level and each device were least-squares fit to a 2nd-order equation with quality of each curve fit evaluated using standard error of the estimate. Bias and average root mean square error were calculated after correcting for the calibration difference between human and in vitro circulation system calibration. The benchtop oximeter maintained good accuracy at all but the most extreme level of anemia. The handheld device was not as accurate as the benchtop, and inaccuracies increased at lower hematocrit levels. The fingertip device was the least accurate of the three oximeters. Pulse oximeter performance is impacted by severe anemia in vitro. The use of in vitro calibration systems may play an important role in augmenting in vivo performance studies evaluating pulse oximeter performance in challenging conditions.


Assuntos
Anemia , Sistema Cardiovascular , Humanos , Oximetria , Oxigênio , Hipóxia , Anemia/diagnóstico
2.
J Clin Monit Comput ; 36(2): 579-586, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33871764

RESUMO

Almost since its introduction pulse oximetry was known to overestimate oxygen saturation in cases of carbon monoxide poisoning or elevated methemoglobin (metHb) levels. To eliminate this dangerous behavior some manufacturers have added additional LED emitters to try to increase the number of measured hemoglobin species and to improve measurement accuracy, but have not been very successful. We hypothesized that the use of narrow-band laser light sources would make accurate and precise measurement of the four primary species of hemoglobin possible, even in cases of elevated levels of carboxyhemoglobin (COHb). Calibration and verification studies were performed on a tissue simulator that employed an artificial finger pulsating with whole human blood. This simulator allowed safe generation of 165 different combinations of the levels of oxyhemoglobin (O2Hb), COHb, metHb, and reduced hemoglobin (RHb) for calibration of the laser-based pulse oximeter. A follow-on study used 56 mixed hemoglobin levels for verification and statistical analysis of the performance of this device. This laser-based pulse oximeter measured all four species of hemoglobin accurately and precisely (ARMS ≤ 1.8%) for metHb levels in the clinically normal range. At elevated metHb levels the device continued to provide accurate and precise measurements of metHb and RHb (ARMS ≤ 1.7%). The use of monochromatic laser light sources can create a new generation of highly accurate, multi-parameter, pulse oximeters.


Assuntos
Carboxihemoglobina , Oximetria , Calibragem , Carboxihemoglobina/análise , Hemoglobinas/análise , Humanos , Lasers , Metemoglobina/análise , Oxigênio