Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Acta Orthop Belg ; 88(3): 433-440, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36791695

RESUMO

The pullout performance of various pedicle screws after artificial fusion process was investigated in this study. Normal, cannulated (cemented), novel expandable and normal (cemented) pedicle screws were tested. Polyurethane foams (Grade 10 and Grade 40) produced by casting method were used as test materials. The instrumentation of pedicle screws has been carried out with production of foams, simultaneously. For cemented pedicle screws, 3D models were prepared with respect to the anteriosuperior and oblique radiographs by using PMMA before casting procedure. Pullout tests were performed in an Instron 3369 testing device. Load versus displacement graph was recorded and the ultimate force was defined as the pullout strength sustained before failure of screw. As expected, the pullout strengths of pedicle screws in postfusion are higher than before fusion. Pullout strengths increased significantly by artificial fusion in Grade 10 foams compared to Grade 40 foams. Additionally, while the pullout strengths of normal, cannulated and novel expandable pedicle screws increased by artificial fusion, cemented normal pedicle screws had lower pullout values than before fusion in Grade 40 foams. When the cemented normal pedicle screws are excluded, other screws have almost similar pullout strength level. On the other hand, the pedicle screws have different increasing behaviour also, there is no correlation between each other. As a result, the novel expandable pedicle screws can be used instead of normal and cannulated ones due to their performances in non-cemented usage.


Assuntos
Parafusos Pediculares , Humanos , Teste de Materiais , Fenômenos Biomecânicos
2.
Biomed Eng Online ; 20(1): 98, 2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620170

RESUMO

BACKGROUND: Posterior pedicle screw (PS) fixation, a common treatment method for widespread low-back pain problems, has many uncertain aspects including stress concentration levels, effects on adjacent segments, and relationships with physiological motions. A better understanding of how posterior PS fixation affects the biomechanics of the lumbar spine is needed. For this purpose, a finite element (FE) model of a lumbar spine with posterior PS fixation at the L4-L5 segment level was developed by partially removing facet joints (FJs) to imitate an actual surgical procedure. This FE study aimed to investigate the influence of the posterior PS fixation system on the biomechanics of the lumbar spine before and after fusion by determining which physiological motions have the most increase in posterior instrumentation (PI) stresses and FJ loading. RESULTS: It was determined that posterior PS fixation increased FJ loading by approximately 35% and 23% at the L3-L4 adjacent level with extension and lateral bending motion, respectively. This increase in FJ loading at the adjacent level could point to the possibility that adjacent segment disease has developed or progressed after posterior lumbar interbody fusion. Furthermore, analyses of peak von Mises stresses on PI showed that the maximum PI stresses of 272.1 MPa and 263.7 MPa occurred in lateral bending and flexion motion before fusion, respectively. CONCLUSIONS: The effects of a posterior PS fixation system on the biomechanics of the lumbar spine before and after fusion were investigated for all physiological motions. This model could be used as a fundamental tool for further studies, providing a better understanding of the effects of posterior PS fixation by clearing up uncertain aspects.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular
3.
Arch Orthop Trauma Surg ; 140(4): 583-590, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32130480

RESUMO

PURPOSE: To compare five different repair techniques for extensor tendon zone III modified Kessler (MK), double-modified Kessler (DMK), modified Kessler epitendinous (MKE), double-modified Kessler epitendinous (DMKE), and running-interlocking horizontal mattress (RIHM) in terms of shortening, stiffness, gap formation, and ultimate load to failure. METHODS: A total of 35 human cadaver fingers were randomly assigned to five suture techniques with 7 fingers each and were tested under dynamic and static loading conditions. RESULTS: DMK was found to be superior over MK in terms of ultimate load to failure (36 N vs. 24 N, respectively), shortening (1.75 vs. 2.20 mm, respectively) and gap formation. However, these two methods had similar characteristics in terms of stiffness. The addition of epitendinous sutures to the repair methods resulted in approximately 40% increase in ultimate load to failure, whereas epitendinous sutures had no effect on shortening. DMKE was found to be superior over MKE in terms of shortening (1.77 vs. 2.22 mm, respectively). However, these two methods had similar characteristics in terms of mean ultimate load to failure and stiffness. RIHM was found to be superior over the other four methods in terms of ultimate load to failure (89 N), stiffness, and shortening (0.75 mm). CONCLUSION: RIHM was found to be stronger and more durable for extensor tendon zone III than the other techniques in terms of ultimate load to failure and stiffness.


Assuntos
Traumatismos dos Dedos/cirurgia , Dedos/cirurgia , Técnicas de Sutura , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Fenômenos Biomecânicos , Humanos
4.
Am J Orthod Dentofacial Orthop ; 157(2): 178-185, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32005469

RESUMO

INTRODUCTION: Anchorage, which is defined as resistance against undesired tooth movements, is one of the most important factors in success of orthodontic treatment. In recent years, mini-implants have been used instead of uncomfortable headgears and Nance appliances. The pullout test is the most common method for measuring the anchorage capacity of mini-implants. The aim of this study was to investigate the effects of cortical bone thickness and cortical layer bone density on pullout strength of mini-implants. METHODS: Mini-implants were placed in polyurethane foam blocks representing 3 different cortical thicknesses (1 mm, 2 mm, and 3 mm) and 3 different cortical bone densities (grade 40, grade 45, and grade 50). Pullout tests were performed with 5 mm/min loading rate. Load vs displacement values were recorded during the tests. RESULTS: Comparing cortical thicknesses on the same bone densities, statistically significant differences were found between 1 mm, 2 mm, and 3 mm thicknesses. Likewise, comparing bone densities on the same cortical thicknesses, statistically significant differences were found among all groups. Spearman rank tests showed that both cortical thickness and cortical bone density are correlated with pullout strength (rs, 0.548; P <0.001 and rs, 0.691; P <0.001, respectively). CONCLUSIONS: Although both factors are positively correlated with pullout strength, the effect of cortical bone density was the dominant factor affecting primary stability.


Assuntos
Osso Cortical , Implantes Dentários , Procedimentos de Ancoragem Ortodôntica , Densidade Óssea , Osso e Ossos , Osso Cortical/anatomia & histologia , Humanos
5.
Knee Surg Sports Traumatol Arthrosc ; 25(9): 2914-2920, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26897136

RESUMO

PURPOSE: The purpose of this study was to investigate the mechanical strength of both monoplanar and biplanar medial opening-wedge high tibial osteotomy (MOWHTO) procedures and assess the risk of lateral cortex disruption for both techniques. METHODS: Twelve synthetic tibia models with cortical shells were used as test models. Saw cuts for monoplanar MOWHTO and biplanar MOWHTO were generated on the test models in equal numbers (n = 6 for both groups). Wedge opening load and wedge gap distance were evaluated via compressive tests. RESULTS: The mean gap distance just before the lateral cortex fracture in the monoplanar group was 14.7 ± 2.9 mm, which was significantly narrower than that in the biplanar group of 19.1 ± 2.0 mm (p = 0.015). The mean load just before the occurrence of lateral cortex fracture of 32.4 ± 3.2 N in the monoplanar osteotomy group was significantly lower than that in the biplanar osteotomy group of 111.8 ± 9.3 N (p = 0.009). CONCLUSION: Performing a MOWHTO via the biplanar rather than the monoplanar technique allows larger-sized wedges to be opened with less risk of lateral cortical fracture. Thus, larger gaps can be opened and higher angle corrections can be achieved using the biplanar osteotomy procedure. From a clinical viewpoint, the biplanar osteotomy technique reduced the risk of lateral cortical hinge fracture during MOWHTO.


Assuntos
Osteotomia/métodos , Tíbia/cirurgia , Fraturas da Tíbia/prevenção & controle , Humanos , Modelos Biológicos , Osteotomia/efeitos adversos , Estresse Mecânico , Suporte de Carga
6.
Comput Biol Med ; 174: 108419, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38583229

RESUMO

INTRODUCTION: In literature, there have been many studies conducted to research the alternatives of standard interlocking intramedullary nailing. The expandable wedge locked nail fixation, which is thought as a new alternative to the standard interlocking nailing, has been presented in previous numerical studies. The antegrade usage of the wedge locked nail fixation has provided promising results. From this point, the aim of the study is to evaluate mechanical behavior of its retrograde usage on femur models. Additionally, another aim of the study is to investigate the effect of fracture level on mechanical properties of the fixation. MATERIALS AND METHODS: The mechanical behaviors of the wedge locked nail and standard interlocking nail fixations were compared by finite element methods. Sawbones femurs having osteotomies at five different levels to simulate different fractures were fixed with wedge locked nail or interlocking nail by using retrograde approach. With respect to the fracture level, two different nail lengths were used. Axial compression load was applied to fixations. The mechanical behaviors of the fixations were evaluated with respect to stiffness of the fixations and stresses occurred on both implants and bones. RESULTS: Any of the wedge locked nail fixation did not slip at canal. The stress and stiffness results were mostly close with each other for both nail types. The maximum stresses at locking elements or bones contacting these elements increased with decreased distance between the fracture and relevant locking elements. DISCUSSION: The wedge locked nail fixation showed comparable results to the standard interlocking nail fixation with respect to the stiffness and stress. Under axial loading, wedge locked nail provided a secured fixation without any slippage and preserved its position inside the medullary canal. It may be thought as a safe alternative to the standard interlocking nail fixation for retrograde usage. Additionally, according to stress results, it is advised to the surgeons to avoid a close locking to the fracture line.


Assuntos
Pinos Ortopédicos , Análise de Elementos Finitos , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/fisiopatologia , Fenômenos Biomecânicos , Fêmur/cirurgia , Modelos Biológicos
7.
Injury ; 55(4): 111413, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38394707

RESUMO

BACKGROUND: Increased posterior wall acetabular fractures among older adults, require precise treatment to restore stability to the joint, lower the risk of degenerative arthritis, and enhance overall functional recovery. The purpose of this study was to compare the fixation stability and mechanical characteristics of calcaneal buttress plate and conventional reconstruction plate under different loading condition. METHODS: Typical acetabular posterior wall fractures were created on twenty synthetic hemipelvis models. They were fixed with calcaneus plate and reconstruction plate. Dynamic and static tests were performed. Displacements of fracture line and stiffness were calculated. FINDINGS: After dynamic loading, calcaneus plate fixation has significantly less displacement than the reconstruction plate on the superior posterior wall. Under static loading condition, the calcaneus plate group has significantly less displacement than the reconstruction plate group on the inferior posterior part of the fracture. The average stiffness values of the calcaneus plate group and the reconstruction plate group were 265.16±53.98 N/mm and 167.48±36.87 N/mm, respectively and a statistically significant difference was found between the two groups. INTERPRETATION: The calcaneal plate group demonstrated better stability along the fracture line after dynamic and static loading conditions. Especially when the fragment was on the acetabulum's superior posterior, inferior posterior, and inferior rim, Calcaneal buttress plates offer biomechanically effective choices.


Assuntos
Calcâneo , Fraturas do Quadril , Lesões do Pescoço , Fraturas da Coluna Vertebral , Humanos , Idoso , Calcâneo/cirurgia , Extremidade Inferior , Próteses e Implantes
8.
PLoS One ; 19(9): e0309263, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39325841

RESUMO

This study aimed to determine the effects of spray dried plasma (SDP) on growth performance, carcass traits, tibia quality, and hemagglutination inhibition titers in broilers fed two nutritional strategies with high or low nutrient density. In the study, 816 one-day-old Ross 308 male broiler chickens were divided into a 2 × 2 factorial arrangements consisting of four treatment groups with 12 replicates (17 birds/replicate) based on diets with high nutrient density (HND) or low nutrient density (LND) from d 0 to 42 and receiving either control or 1% SDP diets during d 0 to 10. The results showed that feed intake (FI) and body weight gain (BWG) were increased (P < 0.05) and feed conversion ratio (FCR) was significantly reduced (P = 0.003) for broilers fed HND diets from d 0 to 42. The inclusion of SDP increased the BWG (P < 0.001), FI (P < 0.001), and FCR (P < 0.05) during d 0 to 10 of broiler life but not effect of SDP was observed for the whole 0-42 d period. Carcass yield increased with HND (P < 0.001) and dietary SDP (P = 0.002). However, HND feeding significantly decreased liver (P < 0.001), bursa of Fabricius (P = 0.002), abdominal fat (P < 0.001), proventriculus (P < 0.001) and gizzard weight (P < 0.001), but increased heart weight (P = 0.013), although spleen weight remained unaffected (P > 0.05) on d 42. Tibial bone morphometric and mechanical properties improved (P < 0.05) with SDP supplementation, and bone ash, Ca, and P remained unaffected (P > 0.05) on d 14. With the exception at d 28 (P = 0.037), the antibody titer to ND virus was similar among all treatment groups (P > 0.05) at d 0, 14, and 42. In conclusion, HND diets improve performance of broilers during the whole period and SDP supplementation during starter phase improve performance at this period, but also increased carcass yield, and tibial quality. Therefore, inclusion of SDP in the starter diet could be a beneficial nutritional strategy to improve the health and production of broilers provided feeding strategies using various nutrient densities.


Assuntos
Ração Animal , Galinhas , Tíbia , Zea mays , Animais , Galinhas/imunologia , Galinhas/crescimento & desenvolvimento , Ração Animal/análise , Tíbia/metabolismo , Masculino , Aminoácidos/metabolismo , Vacinas Virais/imunologia , Vacinas Virais/administração & dosagem , Dieta/veterinária , Doença de Newcastle/prevenção & controle , Doença de Newcastle/imunologia , Glycine max , Plasma/metabolismo , Vírus da Doença de Newcastle/imunologia , Fenômenos Fisiológicos da Nutrição Animal , Suplementos Nutricionais , Aumento de Peso/efeitos dos fármacos
9.
Proc Inst Mech Eng H ; 227(2): 114-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23513982

RESUMO

Pullout is a very common failure mode on the use of pedicle screws. Numerous studies were completed to increase the pullout strength of pedicle screws especially for osteoporotic bones. In this study, a previously designed pedicle screw type was tested before and after fusion condition. Synthetic polyurethane foams were used in all tests. Three different grades of foams were used in tests to simulate severely osteoporotic, osteoporotic, and healthy bones. Test blocks were produced and characterized in our clinical biomechanics laboratory. Foaming of polyurethane was accepted as fusion process (bone in growth). Pedicle screw including radial holes (new design) was tested both before and after the fusion. It also exhibited remarkably higher pullout strength after fusion than before fusion and most of other alternatives stated in the literature. In total, 70% higher pullout strength was achieved with new design after fusion. On the other hand, new design did not dominate other alternatives when comparison was carried out on severely osteoporotic and healthy bones. To the knowledge of the authors, this is the first study investigating the postfusion properties on synthetic foams.


Assuntos
Materiais Biomiméticos/química , Parafusos Ósseos , Osso e Ossos/química , Polímeros/química , Análise de Falha de Equipamento , Fricção , Humanos , Desenho de Prótese
10.
Injury ; 54(2): 379-394, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36509566

RESUMO

INTRODUCTION: Intramedullary nailing has been used as a standard in the treatment of the long bone fractures with its clinical and mechanical advantages. However, using distal locking screws has been associated with longer operative times, higher radiation exposure rates, and complications like breakages of distal screw or nail at the screw hole level. Therefore, attempts to eliminate distal locking screws has been always present for intramedullary nail fixation. With a similar purpose, the present study has been carried out to compare mechanical behaviors of intramedullary nail fixations with different distal locking elements. MATERIALS AND METHODS: In this study, mechanical behaviors of standard interlocking and clawed nail fixations were compared experimentally in the first part. Six fourth generation Sawbones femurs, which have a simulated subtrochanteric fracture, were divided equally and were fixed with standard interlocking and clawed nails. During axial compression tests, experimental strain measurements were taken from all fixations. After validation of numerical models with using experimental strains and stiffnesses, mechanical behaviors of standard interlocking, clawed, and wedge locked nail fixations were compared numerically under axial compression loads. In numerical comparison, the stress-strain distributions were evaluated. RESULTS: Experimental results showed that although that there was no significant difference in stiffnesses, standard nail fixation bore two times higher loads than clawed nail fixations. Under loading, decrease in the distance between fracture surfaces was approximately seven times higher in the clawed nail fixation when compared to standard nail fixations. Numerical results showed that wedge locked nail fixation provided equivalent mechanical behavior to standard interlocking nail. DISCUSSION: In experiments of clawed nail fixation, the high decrease in the distance between fracture surfaces was evidence of the slippage of nail in the medullary canal. For a safe fixation, claws should be deployed when they are completely in contact with the cortical bone, they should be stuck into the bone in a fair amount, and the deployment in the distal third of the femur should be avoided. According to experimentally validated numerical analyses, wedge locked nail fixation may be an alternative for standard interlocking nail fixation if experimental studies support the present results.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos
11.
Injury ; 54(11): 111018, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37730490

RESUMO

INTRODUCTION: Pauwels Type III fractures are unstable and frequently treated with cannulated screws (CS) or dynamic hip screws (DHS). The newly developed talon-cannulated compression devices (TCCD) have the potential to provide rotational stability, mainly through their talon. The study investigates whether TCCD has mechanical advantages over conventional screws or can be as stable as DHS in a reverse triangle configuration for an unstable femoral neck fracture. MATERIAL AND METHODS: After creating a standard Pauwels Type III unstable femoral neck fracture in 36 synthetic femur bones in cortical/hard cancellous bone density, 18 were reserved for dynamic-static tests, and 18 were used for torsional tests. Each group containing 18 synthetic bones was divided into three groups to apply three different fixation materials (CS, DHS, and TCCD), with six models in each group. The displacement amounts after dynamic-static tests were measured using the AutoCAD program according to the reference measurement criteria. During the dynamic tests, a series of photographs were taken. During the static tests, the beginning and post-test photographs were taken. Finally, torsional tests were performed until implant failure occurred in the synthetic femur. RESULTS: In static axial loading tests, TCDD was found to be statistically superior to conventional CS in AL-BL distance (p = 0,014) and CL distance (p = 0,013) measurements, and there was no significant difference between the other groups. There was no significant difference between all groups in dynamic axial compression tests in any points of interest. In torsional tests, TCCD outperformed cannulated screws in stiffness (p = 0,001) and maximum torque (p = 0,001) categories, and they provided statistically significant superiority to DHS in yield torque (p<0,001) category. CONCLUSIONS: Biomechanically, TCCD predominates conventional cannulated screws in femoral neck fractures. TCCD also has superior torsional properties than DHS in the yield torque category. Therefore, TCCD could be the implant of choice for unstable femoral neck fractures.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Humanos , Fixação Interna de Fraturas , Fraturas do Colo Femoral/cirurgia , Suporte de Carga , Osso e Ossos , Fenômenos Biomecânicos
12.
Injury ; 54(10): 110964, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37573841

RESUMO

To compare the amount of displacement and rigidity at the fracture line under static & dynamic axial loading and torsional stress of conventional cannulated screw (CS), plate screw fixation including inter-fragmentary screw (PL), and talon cannulated compression device or talon screw in other words (TS) in posterior column fracture models. Synthetic hemipelvis bone models presenting a posterior column fracture were used in this study. Group PL, CS, and TS were created with ten bone models prepared for each group for dynamic and static loading tests and another ten for torsional tests. Rigidity and displacement amounts before and after loading were measured at the reference points AL, BL, and CL, located at the acetabulum's top, middle, and bottom, respectively. Torsional tests for each group were used to calculate torsional rigidity and maximum torque values. In dynamic axial loading tests, Group CS showed more displacement than PL at the BL point (p = 0,032) and Group TS at AL (p = 0,032) and CL (p = 0,004) points. In static axial loading tests, Group CS significantly displaced more than TS at AL and CL points (p = 0,05 and p = 0,014, respectively). Group PL and Group TS exhibited similar behavior in dynamic, static axial loading tests and torsional rigidity. The maximum torque that Group PL could withstand was statistically significantly higher than the other two groups (p <0,001). Talon cannulated screws had promising results in posterior column fractures of the acetabulum, which may decline the need for open surgery for stable fixation.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Fixação Interna de Fraturas/métodos , Acetábulo/cirurgia , Acetábulo/lesões , Fenômenos Biomecânicos , Fraturas Ósseas/cirurgia , Parafusos Ósseos , Placas Ósseas
13.
Am J Sports Med ; 51(5): 1319-1327, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36815784

RESUMO

BACKGROUND: Peritendinous injection of local anesthetics, alone or in combination with corticosteroids, is widely used in the treatment of tendinopathies. Toxicity of local anesthetics has been demonstrated in many cells, including myocytes, chondrocytes, and neurons. Bupivacaine and lidocaine are known to have time- and dose-dependent cytotoxicity in these cells. The effects of these agents on the tendon remain unknown. PURPOSE: To show histological and biomechanical effects after the injection of different local anesthetics and steroids, both single and combined, at different concentrations into the peritendinous sheath of rat Achilles tendon. STUDY DESIGN: Controlled laboratory study. METHODS: In the study, 100 rats were divided into 10 groups with equal body weights. Inflammation was induced in both Achilles tendons of each rat by means of the ball drop technique; 7 hours later, injections were made into the peritendinous sheaths of both Achilles tendons using lidocaine, bupivacaine, and dexamethasone as appropriate for the rat's group. At the end of the first week, the right Achilles tendons of the rats were removed for histological study. Left Achilles tendons were evaluated in terms of biomechanics. RESULTS: Histological findings demonstrated that the group with the most toxicity to the tendon was the group that received injection of dexamethasone alone. The groups with the least toxicity were those receiving dexamethasone combined with low- or high-dose bupivacaine. Biomechanical findings showed that the experimental groups had similar results to each other with the exception of the groups receiving 0.25% bupivacaine alone and dexamethasone alone, in which tendons revealed higher tensile strength. CONCLUSION: Local anesthetic and steroid applications have different histological and biomechanical effects on the tendon. Although the dexamethasone-injected group was the most affected in terms of histology, these changes could not be demonstrated biomechanically. CLINICAL RELEVANCE: In future clinical studies, the effect of steroids on the tendon should be investigated more comprehensively. Whether biomechanical results overlap with histological results should be investigated further.


Assuntos
Tendão do Calcâneo , Anestésicos Locais , Ratos , Animais , Anestésicos Locais/farmacologia , Anestésicos Locais/uso terapêutico , Bupivacaína/farmacologia , Esteroides , Lidocaína/farmacologia , Lidocaína/uso terapêutico , Dexametasona/farmacologia , Dexametasona/uso terapêutico , Fenômenos Biomecânicos
14.
Proc Inst Mech Eng H ; 226(9): 686-92, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23025169

RESUMO

In this study, a modular anterior lumbar plate is designed and tested in an iterative fashion. The study starts with a basic design that is built by combining same-sized modules; an approach that allow inventory costs to be decreased. The basic design is iteratively improved guided by the results of biomechanical tests performed on each new design. At the end of three iterations of improvements, the design is complete and the plate is of sufficient quality for it to be used in anterior surgical operations. Using these plates creates the advantage of being able to increase the size and slot count during surgical operations, even when some of the modules are already fixed to vertebrae. The designed modular plate is shown to be as safe for use as a rigid plate in terms of its static and fatigue biomechanical performances.


Assuntos
Placas Ósseas , Fixadores Internos , Vértebras Lombares/cirurgia , Modelos Teóricos , Fusão Vertebral/instrumentação , Força Compressiva , Simulação por Computador , Desenho Assistido por Computador , Módulo de Elasticidade , Humanos , Resistência à Tração
15.
Proc Inst Mech Eng H ; 226(1): 33-40, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22888582

RESUMO

Pedicle screw-rod bilateral constructions are extensively used in spinal fixation. In this study, the common cause for failure of bilateral constructions has been determined to be the high stress concentration at the rod-setscrew interface. In order to overcome this problem, a design modification has been made by using a supplementary part (shoe) between rod and setscrew. Performance comparison of the conventional design and modified design has been done by conducting static tests. Design modification has resulted in 11%, 27%, 42% and 31% improvements in axial gripping capacity, torsional gripping capacity, flexion/extension resistance and subassembly compression strength, respectively. The most outstanding achievement has been obtained in the fatigue life, which was extended by almost three times.


Assuntos
Parafusos Ósseos , Desenho Assistido por Computador , Fixação Interna de Fraturas/instrumentação , Fusão Vertebral/instrumentação , Força Compressiva , Desenho de Equipamento , Análise de Falha de Equipamento , Resistência à Tração
16.
Proc Inst Mech Eng H ; 226(3): 256-62, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22558840

RESUMO

In this study, geometrical features of pedicle screws have been modified and their performances are compared. Performance analysis has been made in terms of pull-out strength and torsional strength. The parameters investigated are core diameter, holes drilled normal to screw axis, angle between sequential holes and distance between holes. Three different core diameter have been studied, which are 4 mm (normal core diameter), 5 mm (medium core diameter) and 5.5 mm (high core diameter). Distance between sequential holes has been arranged such that there is either one hole per pitch or one hole per two pitches. Angle between sequential holes is either 90 degrees or 120 degrees. According to the test results, the screw, with medium core diameter (5 mm) containing one hole per two pitches with 90 degrees angle between sequential holes, has exhibited the optimum performance considering torsional strength and pull-out strength requirements. Its torsional strength is slightly higher than and, when Grade 40 polyurethane foam was used as bone simulating material, its pull-out strength is as good as, an undrilled normal core diameter screw, which is already being used in surgical operations. The fatigue performance of this best performed screw has also been found satisfactory according to the related standard. Its pull-out strength is also tested on a calf vertebra and a promising result has been obtained.


Assuntos
Parafusos Ósseos , Osteoporose/fisiopatologia , Osteoporose/cirurgia , Fraturas da Coluna Vertebral/fisiopatologia , Fraturas da Coluna Vertebral/cirurgia , Animais , Bovinos , Análise de Falha de Equipamento , Fricção , Osteoporose/complicações , Desenho de Prótese , Fraturas da Coluna Vertebral/etiologia
17.
Proc Inst Mech Eng H ; 236(7): 960-972, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35522468

RESUMO

Posterior pedicle screw instrumentation (PPSI) is a well-known method in lumbar spine surgery. Understanding how PPSI affects the biomechanics of the lumbar spine is an important issue. In particular, during PPSI operations, surgeons bend rods according to the patients' spinal curvatures based on their own experiences. As a result, residual stresses develop on the rods due to this bending. Although many finite element-based biomechanical studies have been performed for PPSI, studies comparing the effects of residual stresses arising from rod contouring on the construct stresses are lacking. Thus, this study aimed to investigate the effects of residual stress in PPSI using rods contoured with a French bender and an in-situ bender, as well as comparing the differences in stress increment with straight and contoured rods for different physiological motions. Accordingly, a finite element (FE) model of the L4-L5 lumbar spine segment was developed for PPSI and the effects of residual stresses on rods were investigated by using different bending methods. In the simulations, it was found that rods contoured with a French bender with residual stress resulted in significantly more increased stress in PPSI compared to those contoured with an in-situ bender. The results of this study emphasize that increased stress in PPSI due to the residual stresses for different physiological motions may increase the risk of PPSI failures. Additionally, the finite element modeling approach employed here could be used as a fundamental tool for further investigations of topics such as PPSI fatigue life and failure studies.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Vértebras Lombares/fisiologia , Vértebras Lombares/cirurgia , Região Lombossacral , Amplitude de Movimento Articular
18.
J Mech Behav Biomed Mater ; 125: 104941, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34749203

RESUMO

Bioceramic/polymer composite systems have gained importance in treating hard tissue damages using bone tissue engineering (BTE). In this context, it was aimed to develop 3D porous composite PCL-PEG-PCL scaffolds containing different amounts of B, Sr and Mg multi-doped HA that can provide bone regeneration in the bone defect area and to investigate the effect of both the amount of inorganic phase and the porosity on the mechanical and the biological properties. B-Sr-Mg multi-doped HA and PCL-PEG-PCL copolymer were successfully synthesized. PCL-PEG-PCL composite scaffolds containing different amounts of hydroxyapatite (HA) (10% and 20 wt%) were produced with the desired porosity (50% and 60%) by compression-molding and particulate leaching method. The porosity of the scaffolds was determined between 47% and 59%. HA/PCL-PEG-PCL composite scaffolds were subjected to a 3-week degradation test and showed negligible (0.2-0.5%) degradation. The water uptake percentage of the composite scaffolds with 60% porosity was the highest among all groups. Presence of HA in the scaffolds improved the water adsorption and the mechanical properties. Compressive strength of the scaffolds was between 9.32 and 24.27 MPa and 20% 2Sr0.5BHA scaffolds were found to have the maximum compressive strength. Compressive strength of 50% porous samples was higher than that of 60% porous samples. In the relative cell viability (%) test, the highest viability was observed on the scaffolds with HA and 2Sr0.5BHA. The specific ALP activity level of the cells on the scaffolds containing 2Sr0.5BHA was significantly higher (2.6 times) than that of the control group. The amount of porosity did not make a significant difference in cellular response. It was concluded that PCL-PEG-PCL composite scaffolds with 2Sr0.5BHA have the potential to be used in BTE.


Assuntos
Magnésio , Engenharia Tecidual , Boro , Durapatita , Poliésteres , Polietilenoglicóis , Porosidade , Estrôncio
19.
Cureus ; 14(4): e24158, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35592198

RESUMO

Objectives Anterior column fractures can be seen as either isolated or accompanied by many types of complex acetabulum fractures. The aim of this study was to biomechanically compare the stability of a standard pelvic brim plate with a more laterally located suprapectineal plate, which is more commonly used in minimally invasive application, on an intermediate height anterior column fracture model under dynamic and static loading. Materials and methods Right side, adult, foam cortical shell artificial hemipelvis models were used (Sawbones, Pacific Research Laboratories, Vashon, WA, USA). Twenty-four (24) pieces of foam cortical shell artificial hemipelvis models were separated into three groups (M, L, and control). In group "M," a suprapectineal plate was placed medially just adjacent to the pelvic brim. In group "L," a laterally located suprapectineal plate was placed 2 cm lateral of the pelvic brim at its most proximal point. Then, dynamic load testing of 1000 cycles between 50 N and 500 N force and a static load test of 1.2 kN at 2 mm/minute were applied. Dynamic and static tests were conducted on an axial compression device. Displacements were measured after dynamic and static loading conditions. Results In the dynamic loading test at the AL point (superior intersection of the fracture line with the acetabular roof), the median displacement was significantly higher in group L than in group M (0.12 (IQR: 0.058-0.8125) mm and 0.04 (IQR: 0.03-0.065) mm (p = 0.02)). There was no other statistically significant difference in the displacement amounts in both dynamic and static loading conditions at other measurement points. The comparison of the stiffness of the M and L groups showed no statistically significant results, while the control group was significantly more rigid than both the M and L groups (p = 0.04 for both). None of the artificial hemipelvis models was found to be fractured at the end of the test. Conclusion Suprapectineal plates, placed on either the medial or lateral aspect of the pelvic brim, may be used for the fixation of anterior column-type fractures to provide rigid fixation and stability. As plate location did not impact stiffness and stability, the results suggest that surgeons have flexibility in determining the fixation based on accessibility, fracture pattern, and surgeon experience.

20.
Acta Ortop Bras ; 30(1): e248473, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35431623

RESUMO

Introduction: We compared the mechanical properties of two fixation techniques for the treatment of extra-articular distal third humeral fractures. Materials and Methods: Two groups were created from twenty-four humeri. Group 1 was instrumented using a new, precontoured, 8-hole (3.5-mm-diameter) locking compression plate (LCP) placed anterolaterally. Group 2 was instrumented using an 8-hole (3.5-mm-diameter) precontoured posterolateral LCP plate placed on the distal humerus. Four-point bending tests and torsion tests were performed until the specimens broke. Results: The four-point bending stiffness test showed that the stiffness of anterolaterally fixed humeri was significantly higher than that of posterolaterally fixed humeri (p<0.05). Torsion testing revealed that posterolateral fixation was associated with better yield strength (p<0.05), but the torsional stiffness did not differ significantly between the two plates (p> 0.05). Conclusions: The anterolateral plate exhibited higher bending stiffness and torsional yield strength than the posterolateral plate. Anterolateral plate fixation can thus be used to manage extra-articular distal humeral fractures. Multiaxial locking screws ensure rigid fixation, allow early elbow motion without olecranon fossa impingement, and prevent iatrogenic injury of the triceps muscle. Level of Evidence I, Therapeutic Studies Investigating the Results of Treatment.


Introdução: Comparamos as propriedades mecânicas de duas técnicas de fixação para o tratamento de fraturas extra-articulares do terço distal do úmero. Materiais e Métodos: Dois grupos foram criados a partir de vinte e quatro úmeros. O Grupo 1 foi instrumentado com uma nova placa de compressão com travamento (LCP) pré-contornada e com oito orifícios (3,5 mm de diâmetro) posicionados anterolateralmente. O Grupo 2 foi instrumentado com uma placa LCP pré-contornada posterolateral com oito orifícios (3,5 mm de diâmetro) colocada na parte distal do úmero. Testes de flexão e testes de torção a quatro pontos foram realizados até que os corpos de prova quebrassem. Resultados: O teste de rigidez à flexão de quatro pontos mostrou que a rigidez dos úmeros fixados anterolateralmente foi significativamente maior do que os úmeros fixados posterolateralmente (p <0,05). O teste de torção revelou que a fixação posterolateral foi associada a melhor força de rendimento (p <0,05), mas a rigidez à torção não diferiu significativamente entre as duas placas (p > 0,05). Conclusões: A placa anterolateral apresentou maior rigidez à flexão e resistência à tração do que a placa posterolateral. A fixação anterolateral da placa pode, portanto, ser usada para tratar fraturas extra-articulares da parte distal do úmero. Os parafusos de travamento multiaxiais garantem uma fixação rígida, permitem o movimento precoce do cotovelo sem causar impacto à fossa do olécrano e previnem lesão iatrogênica do músculo tríceps. Nível de evidência I, Estudos terapêuticos - Investigação dos resultados do tratamento.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA