Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 121(16): 165002, 2018 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-30387678

RESUMO

The first direct measurements of an impurity particle flux driven by drift-wave turbulence in a toroidal magnetized plasma are reported. The correlation between the impurity density and radial velocity fluctuations is measured using ion Doppler spectroscopy. The small, very fast radial velocity fluctuation is resolved with the aid of a new linearized spectrum correlation analysis method that rejects uncorrelated noise as the sample size increases. The measured C^{2+} turbulent impurity flux in the edge of the plasma is directed inward and is consistent with impurity density measurements. This is also the first direct evidence for fluctuation-induced transport due to trapped-electron-mode turbulence in reversed field pinch plasmas.

2.
Phys Rev Lett ; 110(6): 065008, 2013 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-23432267

RESUMO

A new mechanism for intrinsic plasma flow has been experimentally identified in a toroidal plasma. For reversed field pinch plasmas with a few percent ß (ratio of plasma pressure to magnetic pressure), measurements show that parallel pressure fluctuations correlated with magnetic fluctuations create a kinetic stress that can affect momentum balance and the evolution of intrinsic plasma flow. This implies kinetic effects are important for flow generation and sustainment.

3.
Phys Rev Lett ; 108(12): 125006, 2012 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-22540593

RESUMO

High-resolution measurements of impurity ion dynamics provide first-time evidence of classical ion confinement in a toroidal, magnetically confined plasma. The density profile evolution of fully stripped carbon is measured in MST reversed-field pinch plasmas with reduced magnetic turbulence to assess Coulomb-collisional transport without the neoclassical enhancement from particle drift effects. The impurity density profile evolves to a hollow shape, consistent with the temperature screening mechanism of classical transport. Corroborating methane pellet injection experiments expose the sensitivity of the impurity particle confinement time to the residual magnetic fluctuation amplitude.

4.
Sci Rep ; 12(1): 15112, 2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36068266

RESUMO

Thomson scattering measurements with a high-repetition-rate laser have commenced in the Large Helical Device. As an example of the fast phenomena captured by this diagnostic system, measurements at a 20 kHz repetition-rate in hydrogen pellet-injected plasmas are presented. Signal processing methods for this measurement have been developed and electron temperature profiles with almost 70 spatial points were evaluated at time intervals of 50 [Formula: see text]s. After Raman scattering calibration, electron density profiles were derived. Fast changes in the electron temperature and density profiles within 1 ms were observed.

5.
Sci Rep ; 12(1): 6979, 2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35577787

RESUMO

The preceding propagation of turbulence pulses has been observed for the first time in heat avalanche events during the collapse of the electron internal transport barrier (e-ITB) in the Large Helical Device. The turbulence and heat pulses are generated near the foot of the e-ITB and propagate to the peripheral region within a much shorter time than the diffusion timescale. The propagation speed of the turbulence pulse is approximately 10 km/s, which is faster than that of the heat pulse propagating at a speed of 1.5 km/s. The heat pulse propagates at approximately the same speed as that in the theoretical prediction, whereas the turbulence pulse propagates one order of magnitude faster than that in the prediction, thereby providing important insights into the physics of non-local transport.

6.
Phys Rev Lett ; 107(15): 155002, 2011 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-22107297

RESUMO

New high time resolution measurements of the electron thermal diffusion χ(e) throughout the sawtooth cycle of the Madison Symmetric Torus reversed-field pinch have been made by utilizing the enhanced capabilities of the upgraded multipoint, multipulse Thomson scattering system. These measurements are compared to the χ(e) due to magnetic diffusion predicted by using information from a new high spectral resolution zero-ß nonlinear resistive magnetohydrodynamic simulation performed, for the first time, at the Lundquist number of high current Madison Symmetric Torus plasmas (S≈4×10(6)). Agreement between the measured and predicted values is found only if the reduction in thermal diffusion due to trapped particles is taken into account.

7.
Phys Rev Lett ; 107(6): 065005, 2011 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-21902334

RESUMO

Complementary measurements of ion energy distributions in a magnetically confined high-temperature plasma show that magnetic reconnection results in both anisotropic ion heating and the generation of suprathermal ions. The anisotropy, observed in the C(+6) impurity ions, is such that the temperature perpendicular to the magnetic field is larger than the temperature parallel to the magnetic field. The suprathermal tail appears in the majority ion distribution and is well described by a power law to energies 10 times the thermal energy. These observations may offer insight into the energization process.

8.
Rev Sci Instrum ; 92(5): 053549, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243280

RESUMO

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ∼1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the Te profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. This allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

9.
Rev Sci Instrum ; 92(6): 063520, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243585

RESUMO

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

10.
Rev Sci Instrum ; 92(7): 073502, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340413

RESUMO

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 µm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

11.
Rev Sci Instrum ; 89(10): 10K103, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399657

RESUMO

The analysis approach called integrated data analysis (IDA) provides a means to exploit all information present in multiple streams of raw data to produce the best inference of a plasma parameter. This contrasts with the typical approach in which information (data) from a single diagnostic is used to measure a given parameter, e.g., visible bremsstrahlung → Z eff. Data from a given diagnostic usually contain information on many parameters. For example, a Thomson scattering diagnostic is sensitive to bremsstrahlung and line emission in addition to electron temperature. This background light is typically subtracted off and discarded but could be used to improve knowledge of Z eff. IDA encourages explicit awareness of such information and provides the quantitative framework to exploit it. This gives IDA the ability to increase spatial and temporal resolution, increase precision and accuracy of inferences, and measure plasma parameters that are difficult or impossible to measure using single diagnostic techniques. One example is the measurement of Z eff on Madison symmetric torus using IDA since no single diagnostic can provide a robust measurement. As we enter the burning plasma era, application of IDA will be critical to the measurement of certain parameters, as diagnostic access in the harsh fusion environment will be extremely limited.

12.
Rev Sci Instrum ; 78(1): 013103, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17503903

RESUMO

A new custom-built duo spectrometer has been commissioned for fast localized Doppler measurements of plasma ions in the Madison Symmetric Torus. The instrument combines very high optical throughput (transmission efficiency of 6% and etendue of 0.80 mm(2) sr divided into two simultaneous measurements) with good resolution (lambda/Deltalambda=5600). The design is a double grating variant of the Czerny-Turner layout and has been carefully optimized for fast (100 kHz) measurements of the C VI line at 343.4 nm. The instrument is currently being applied for high speed charge exchange recombination spectroscopy measurements.


Assuntos
Efeito Doppler , Íons/análise , Análise Espectral , Análise Espectral/instrumentação , Análise Espectral/métodos
13.
Rev Sci Instrum ; 88(8): 083513, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28863643

RESUMO

A new spectral analysis method, Linearized Spectrum Correlation Analysis (LSCA), for charge exchange and passive ion Doppler spectroscopy is introduced to provide a means of measuring fast spectral line shape changes associated with ion-scale micro-instabilities. This analysis method is designed to resolve the fluctuations in the emission line shape from a stationary ion-scale wave. The method linearizes the fluctuations around a time-averaged line shape (e.g., Gaussian) and subdivides the spectral output channels into two sets to reduce contributions from uncorrelated fluctuations without averaging over the fast time dynamics. In principle, small fluctuations in the parameters used for a line shape model can be measured by evaluating the cross spectrum between different channel groupings to isolate a particular fluctuating quantity. High-frequency ion velocity measurements (100-200 kHz) were made by using this method. We also conducted simulations to compare LSCA with a moment analysis technique under a low photon count condition. Both experimental and synthetic measurements demonstrate the effectiveness of LSCA.

14.
Rev Sci Instrum ; 87(11): 11E530, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910690

RESUMO

The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier's cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

15.
Rev Sci Instrum ; 87(11): 11E322, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910686

RESUMO

The Soft X-Ray (SXR) tomography system on the Madison Symmetric Torus uses four cameras to determine the emissivity structure of the plasma. This structure should directly correspond to the structure of the magnetic field; however, there is an apparent phase difference between the emissivity reconstructions and magnetic field reconstructions when using a cylindrical approximation. The difference between the phase of the dominant rotating helical mode of the magnetic field and the motion of the brightest line of sight for each SXR camera is dependent on both the camera viewing angle and the plasma conditions. Holding these parameters fixed, this phase difference is shown to be consistent over multiple measurements when only toroidal or poloidal magnetic field components are considered. These differences emerge from physical effects of the toroidal geometry which are not captured in the cylindrical approximation.

16.
Rev Sci Instrum ; 87(11): 11E509, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910359

RESUMO

An Ion Doppler Spectrometer (IDS) is used for fast measurements of C VI line emission (343.4 nm) in the Madison Symmetric Torus. Absolutely calibrated flow measurements are difficult because the IDS records data within 0.25 nm of the line. Commercial calibration lamps do not produce lines in this narrow range. A light source using an ultraviolet LED and etalon was designed to provide a fiducial marker 0.08 nm wide. The light is coupled into the IDS at f/4, and a holographic diffuser increases homogeneity of the final image. Random and systematic errors in data analysis were assessed. The calibration is accurate to 0.003 nm, allowing for flow measurements accurate to 3 km/s. This calibration is superior to the previous method which used a time-averaged measurement along a chord believed to have zero net Doppler shift.

17.
Rev Sci Instrum ; 87(11): 11E543, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910452

RESUMO

A grating spectrometer with an electron multiplying charge-coupled device camera is used to diagnose a 50 kV, 5 A, 20 ms hydrogen diagnostic neutral beam. The ion source density is determined from Stark broadened Hß emission and the spectrum of Doppler-shifted Hα emission is used to quantify the fraction of ions at full, half, and one-third beam energy under a variety of operating conditions including fueling gas pressure and arc discharge current. Beam current is optimized at low-density conditions in the ion source while the energy fractions are found to be steady over most operating conditions.

18.
Rev Sci Instrum ; 87(11): 11E332, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910453

RESUMO

The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXRDF) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXRDF measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXRDF discrepancy, and evidence from experiments indicates that this discrepancy is due to physics missing from the SXRDF analysis rather than instrumentation effects.

19.
Rev Sci Instrum ; 87(11): 11E547, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910649

RESUMO

The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.

20.
Rev Sci Instrum ; 87(11): 11E511, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910553

RESUMO

The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.