Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson ; 141(2): 207-16, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10579944

RESUMO

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional input parameters. The time course of p(O(2)) during short periods of breathholding is found to be linear in a pig as well as in a human volunteer. We also measured the wall relaxation time in the lung and deduced a lower limit of 4.3 min.


Assuntos
Hélio , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Oxigênio/fisiologia , Adulto , Animais , Apneia , Humanos , Isótopos , Pulmão/anatomia & histologia , Masculino , Pressão Parcial , Imagens de Fantasmas , Suínos
2.
Magn Reson Med ; 47(1): 105-14, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11754449

RESUMO

MRI of the lungs using hyperpolarized helium-3 ((3)He) allows the determination of intrapulmonary oxygen partial pressures (p(O2)). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure p(O2) by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary p(O2) are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of (3)He hyperpolarization within the lungs were performed to evaluate the accuracy of this measurement technique, and its limitations.


Assuntos
Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética , Simulação por Computador , Hélio , Humanos , Processamento de Imagem Assistida por Computador , Isótopos , Método de Monte Carlo , Oxigênio , Pressão Parcial , Ventilação Pulmonar/fisiologia
3.
NMR Biomed ; 13(4): 194-201, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10867696

RESUMO

We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisition approach.


Assuntos
Apneia/fisiopatologia , Hélio , Imageamento por Ressonância Magnética/métodos , Oxigênio/análise , Testes de Função Respiratória/métodos , Adulto , Feminino , Humanos , Isótopos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pressão Parcial , Valores de Referência , Reprodutibilidade dos Testes , Mecânica Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA