Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Magn Reson Imaging ; 56(1): 158-170, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34797013

RESUMO

BACKGROUND: The ovarian-adnexal reporting and data system-magnetic resonance imaging (O-RADS-MRI) score decreases the incidence of indeterminate adnexal masses from 18% to 31% with ultrasound till 10.8% to 12.5% with MRI. Further improvement of this score may be useful to improve patients' management. PURPOSE: To evaluate the added value of quantitative diffusion-weighted imaging (DWI) in the diagnosis of adnexal masses classified according to the O-RADS-MRI score. STUDY TYPE: Prospective cohort study with retrospective DWI analysis. POPULATION: Among 402 recruited patients, surgery was done only in 163 women (median-age: 51 years) with 201 indeterminate adnexal masses, which were included in the final analysis. FIELD STRENGTH/SEQUENCE: Standardized MRI (1.5 and 3-T) including diffusion and dynamic contrast-enhanced sequences (diffusion-weighted single-shot spin-echo echo-planar imaging) were used. ASSESSMENT: Two radiologists classified the adnexal masses according to O-RADS-MRI and they were blinded to the pathology report. Two methods of quantitative analysis were applied using region-of-interest apparent-diffusion-coefficient (ROI-ADC) and whole-lesion ADC-histogram (WL-ADC). STATISTICAL TESTS: Fisher's exact and Mann-Whitney-U tests were used to compare variables among malignant and benign lesions. Receiver-operating-characteristic (ROC) curves were constructed to examine the sensitivity/specificity of each parameter. ROI-ADC and WL-ADC of lesions with O-RADS-MRI score-4 were plotted to identify thresholds of malignant lesions. The improvement of the O-RADS-MRI score after adding these thresholds was assessed by two ROC-curves. A P < 0.05 was considered to be statistically significant. RESULTS: Fifty-eight of the 201 lesions (28.9%) were malignant. The ROI-ADC and the WL-ADC means of malignant lesions were significantly lower than those of benign lesions. Forty-two lesions (20.9%) had an O-RADS-MRI score-4. In this subgroup, 76% of lesions with ROI-ADC < 1.7 × 10-3  mm2 /sec and WL-ADC < 2.6 × 10-3  mm2 /sec were malignant, whereas only 11.8% with ROI-ADC ≥ 1.7 × 10-3  mm2 /sec or a WL-ADC ≥ 2.6 × 10-3  mm2 /sec were malignant. The overall performance of the O-RADS-MRI score combined with these thresholds was improved. DATA CONCLUSION: Integrating ADC-thresholds in O-RADS-MRI score-4 may discriminate low-to-intermediate and intermediate-to-high malignancy risk groups. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Doenças dos Anexos , Imagem de Difusão por Ressonância Magnética , Anexos Uterinos , Doenças dos Anexos/diagnóstico por imagem , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Eur Radiol ; 30(6): 3083-3093, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32065282

RESUMO

PURPOSE: To compare 3D T1-weighted fast spin echo (FSE) and 3D T1-weighted gradient echo (GE) mDixon as morphologic sequences to complement diffusion-weighted imaging (DWI) for the metastatic screening in prostate cancer (PCa) patients. MATERIALS AND METHODS: Thirty PCa patients at high risk of metastases prospectively underwent both a 3D T1 FSE (14 min) and a rapid 3D T1 GEmDixon (1 min 20 s) sequences within a WB-MRI protocol. Two readers assessed the diagnostic performance of the FSE/Fat/in-phase (IP)/IP+Fat sequences in detecting bone and node metastases. The reference standard was established by a panel of four physicians on the basis of all baseline and follow-up imaging, biological and clinical information. The reproducibility of readings, predictive accuracy (Acc) from ROC curves analysis, and contrast-to-reference ratio (CRR) in lesions were assessed for each sequence. RESULTS: In bone and lymph nodes (per-region analysis), reproducibility was at least good for all sequences/readers, except for nodes in the common iliac/inguinal regions. In bone (per-organ analysis), Acc of FSE was superior to that of mDixon (difference + 4%, p < 0.0083). In nodes (per-organ analysis), Acc of Fat was superior to that of other sequences (difference + 4% to + 6% depending on reader, p < 0.0083). In the per-patient analysis, Acc of FSE was superior to that of mDixon (difference + 4% to + 6% depending on sequence, p < 0.0083). Fat images had higher CRR compared with FSE in the thoracic spine, the bony pelvis and lymph node metastases (p < 0.025). CONCLUSION: 3D T1 GEmDixon may replace 3D T1 FSE to complement DWI in WB-MRI for metastatic screening in PCa. It demonstrates an Acc ranging from + 4% to + 6% (nodes) to - 4% to - 6% (bone and patient staging) compared with FSE and considerably reduces the examination time, offering the perspective of acquiring WB-MRI examinations in less than 20 min. KEY POINTS: • The replacement of 3D T1 FSE by the 3D T1 GE mDixon as morphologic sequence to complement DWI drastically reduces the acquisition time of WB-MRI studies. • The 3D T1 GE mDixon sequence offers similar reproducibility of image readings compared with that of the 3D T1 FSE. • Differences in diagnostic accuracy are limited (+ 4%/+ 6% in favor of mDixon to detect node metastases; + 4%/+ 6% in favor of FSE to detect bone metastases/metastatic disease in a patient).


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Detecção Precoce de Câncer/métodos , Neoplasias da Próstata/diagnóstico , Imagem Corporal Total/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/secundário , Reprodutibilidade dos Testes
3.
J Magn Reson Imaging ; 43(5): 1100-10, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26566777

RESUMO

PURPOSE: To prospectively assess liver ADC (apparent diffusion coefficient) repeatability from cardiac-triggered diffusion-weighted images obtained with an individually predetermined optimal cardiac time window minimizing cardiac-related effects and to evaluate a signal filtering method aimed at artifact elimination. MATERIALS AND METHODS: After Institutional Review Board approval and written informed consent, eight healthy volunteers underwent four repetitions of respiratory-triggered diffusion-weighted sequences (3T, b: 0,150,500 s/mm(2) ) without (RTnoCT, 51 sec) and with individually optimized cardiac triggering (RTCT, 306 sec). The optimal cardiac delay was individually predetermined using a 5-second breath-hold sequence. Monoexponential liver ADC and left-to-right-liver ADC ratio were computed from region of interest (ROI) signal measurements (two independent readers). A filtering method, excluding signal intensities lower than the mean intensity at fixed b-value, provided ADC recalculation. Limits-of-agreement (LOAs) from 95% confidence intervals for differences across the four repetitions provided the variability range. RESULTS: For Reader 1 (Reader 2), left-to-right-liver ADC ratios were significantly higher in RTnoCT 1.51 (1.52) than in RTCT 1.12 (1.15), P = 0.012 (P = 0.017). Respectively for RTnoCT and RTCT: left liver LOAs were ±835 (±775), ± 315 (±369) 10(-6) mm(2) /s; right liver LOAs were ±392 (±445), ± 172 (±140) 10(-6) mm(2) /s: LOAs were larger in the left than in the right lobe (both P < 0.001). After filtering, left liver ADC LOAs narrowed to ±650 (±367) 10(-6) mm(2) /s, P = 0.17 (P < 0.001); ± 152 (±208) 10(-6) mm(2) /s (both P < 0.002) and left-to-right-liver ADC ratio decreased to 1.28 (1.20), P = 0.017 (P = 0.012); 1.09 (1.08), P = 0.106 (P = 0.105). CONCLUSION: Compared to noncardiac-triggered acquisitions, individually optimized cardiac-triggered acquisitions improved ADC repeatability in both liver lobes and reduced ADC differences between left and right liver. Left liver ADC repeatability was further improved after signal filtering.


Assuntos
Imagem de Difusão por Ressonância Magnética , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Adulto , Artefatos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
4.
Magn Reson Med ; 70(3): 732-44, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23023932

RESUMO

PURPOSE: Because of its paramagnetic properties, oxygen may act as an endogenous magnetic resonance imaging contrast agent by changing proton relaxation rates. Changes in tissue oxygen concentrations have been shown to produce changes in relaxation rate R1 of water. The aim of the study was to improve the sensitivity of oxygen enhanced R1 imaging by exploiting the higher solubility of oxygen in lipids (as compared with water) to sensitively monitor changes in tissue oxygen levels by selectively measuring the R1 of lipids. METHODS: The method, with the acronym "MOBILE" (mapping of oxygen by imaging lipids relaxation enhancement), was applied in different mouse models of hypoxic processes on a 11.7 T magnetic resonance imaging system. MOBILE was compared with R*2, R1 of water, and with pO2 measurements (using electron paramagnetic resonance oximetry). MOBILE was also applied in the brain of healthy human volunteers exposed to an oxygen breathing challenge on a 3 T magnetic resonance imaging system. RESULTS: MOBILE was shown to be able to monitor changes in oxygenation in tumor, peripheral, liver, and brain tissues. The clinical translation was demonstrated in human volunteers. CONCLUSION: MOBILE arises as a promising noninvasive and sensitive tool for diagnosis and therapeutic guidance in disorders involving hypoxia.


Assuntos
Imageamento por Ressonância Magnética , Oxigênio/análise , Animais , Neoplasias da Mama , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Lipídeos/análise , Camundongos , Monitorização Fisiológica , Neoplasias/metabolismo , Oximetria , Prótons , Acidente Vascular Cerebral
5.
Radiology ; 261(2): 456-66, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21852570

RESUMO

PURPOSE: To prospectively determine whether dynamic contrast material-enhanced (DCE) magnetic resonance (MR) quantitative parameters correlate with fibrosis and microvascular density (MVD) in malignant and benign solid pancreatic focal lesions and nontumoral pancreatic tissue. MATERIALS AND METHODS: The institutional review board approved the study; written informed consent was obtained. DCE MR was performed in 28 patients with surgically resectable focal pancreatic lesions. DCE MR quantitative parameters derived from one-compartment (OC) (transfer rate constant [K(trans)] and distribution fraction [ƒ]) and two-compartment (TC) (K(trans), tissue volume fraction occupied by extravascular extracellular space [v(i)], and tissue volume fraction occupied by vascular space [v(p)]) pharmacokinetic models were correlated with fibrosis content and MVD counts in focal lesions and nontumoral tissue (Spearman correlation coefficient [SCC]). Pharmacokinetic parameters were compared (Mann-Whitney test) between tumoral and nontumoral tissue. Diagnostic performance of DCE MR fibrosis detection was assessed (receiver operator characteristic curve analysis). RESULTS: K(trans) OC and K(trans) TC were significantly lower in primary malignant tumors compared with benign lesions (P = .023) and nontumoral pancreatic tissue downstream (P < .001) and upstream (P = .006); ƒ and v(i) were significantly higher in primary malignant tumors compared with nontumoral pancreatic tissue downstream (P = .012 and .018, respectively). Fibrosis was correlated negatively with K(trans) OC (SCC, -0.600) and K(trans) TC (SCC, -0.564) and positively with ƒ (SCC, 0.514) and v(i) (SCC, 0.464), with P < .001 (all comparisons). MVD was positively correlated with ƒ (SCC, 0.355; P = .019) and v(i) (SCC, 0.297; P = .038) but not with K(trans) OC (SCC, -0.140; P = .33) and K(trans) TC (SCC, -0.194; P = .181). Sensitivity and specificity for fibrosis detection were 65% (24 of 37) and 83% (10 of 12) for K(trans) OC (cutoff value, 0.35 min(-1)) and 76% (28 of 37) and 83% (10 of 12) for K(trans) TC (cutoff value, 0.29 min(-1)), respectively. CONCLUSION: Quantitative DCE MR parameters, derived from pharmacokinetic models in malignant and benign pancreatic solid lesions and nontumoral pancreatic tissue, were significantly correlated with fibrosis and MVD. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11103515/-/DC1.


Assuntos
Imageamento por Ressonância Magnética/métodos , Pancreatopatias/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacocinética , Feminino , Fibrose/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Masculino , Meglumina/farmacocinética , Pessoa de Meia-Idade , Neovascularização Patológica/patologia , Compostos Organometálicos/farmacocinética , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Curva ROC , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
6.
Neuroimage ; 51(2): 783-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20206706

RESUMO

In this MRI study, we aimed to provide new in vivo structural markers of asymmetry in motor and language networks in a population of healthy preterm neonates scanned at term equivalent age. Using diffusion tensor imaging and probabilistic tractography, we showed that, besides volume and microstructural asymmetries in the parieto-temporal part of the superior longitudinal fasciculus (SLF) and a trend towards microstructural asymmetry in the corticospinal tract (CST), volume asymmetry in the motor part of the superior thalamic radiations (STR) and a trend towards volume asymmetry in the CST are already present in the neonatal period. No asymmetry was found in the sensory part of the STR, the anterior thalamic radiations (ATR), and posterior thalamic radiations (PTR) neither in the fronto-parietal part of the SLF. These results suggest that structural asymmetries in the motor and language networks are present in healthy preterm neonates at term equivalent age, well before the development of speech and hand preference.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/anormalidades , Imagem de Difusão por Ressonância Magnética , Recém-Nascido Prematuro , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Recém-Nascido , Masculino
7.
Radiology ; 247(1): 115-21, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18292476

RESUMO

PURPOSE: To prospectively quantify pancreatic regional perfusion with dynamic contrast material-enhanced magnetic resonance (MR) imaging by using a one-compartment model and to assess perfusion changes during secretin stimulation in healthy volunteers. MATERIALS AND METHODS: The study had institutional review board approval, and written informed consent was obtained. Ten healthy volunteers (five men, five women; mean age, 24.7 years +/- 1.9 [standard deviation]; range, 22-29 years) underwent MR imaging pancreatic perfusion studies performed twice without secretin and twice during secretin stimulation. Dynamic contrast-enhanced MR imaging consisted of saturation-recovery T1-weighted turbo-field-echo imaging with peripheral pulse triggering and respiratory tracking. A dose of 0.05 mmol gadodiamide per kilogram of body weight was injected at a rate of 3.5 mL/sec. Regional perfusion parameters were fitted with a one-compartment model. The analysis of variance test for repeated measurements was used to assess differences in pancreatic perfusion without and that with secretin administration. RESULTS: Significant differences in perfusion parameters between the three pancreatic regions were observed (P < .05). During secretin stimulation, a significant difference was observed only between the body and the tail of the pancreas (P = .02). A significant increase (P = .003) in pancreatic perfusion was observed after secretin administration. Mean pancreatic perfusion was 184 mL/min/100 g of tissue +/- 71, 207 mL/min/100 g +/- 77, and 230 mL/min/100 g +/- 87 without secretin and 342 mL/min/100 g +/- 154, 338 mL/min/100 g +/- 156, and 373 mL/min/100 g +/- 176 after secretin stimulation in the head, body, and tail of the pancreas, respectively. Intraindividual variability was 21% without secretin stimulation and 46% with secretin stimulation. CONCLUSION: Dynamic contrast-enhanced MR imaging enables noninvasive quantification of regional pancreatic perfusion in resting conditions and demonstrates the increase in pancreatic perfusion during secretin stimulation in healthy subjects.


Assuntos
Meios de Contraste , Gadolínio DTPA , Imageamento por Ressonância Magnética , Pâncreas/irrigação sanguínea , Testes de Função Pancreática , Secretina , Adulto , Feminino , Humanos , Masculino , Valores de Referência
8.
AJNR Am J Neuroradiol ; 26(9): 2256-66, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16219831

RESUMO

PURPOSE: To assess the concordance between data from functional MR imaging (fMRI) guidance and the intraoperative electrical cortical mapping (iCM) in targeting selective motor cortex areas in refractory neuropathic pain. METHODS: Twenty-one patients (11 women and 10 men; mean age, 55.6 years) with refractory central (ischemic, 8 cases) and neuropathic pain (trigeminal neuropathy, 6 cases; syrinx/amputation/plexus trauma, 7 cases) underwent surgery for the implantation of an epidural electrode for chronic motor cortex stimulation (MCS) with general anesthesia and a frameless neuronavigation system used for the image-guided targeting procedure. All patients were studied by preoperative fMRI and epidural iCM with somatosensory evoked potentials and motor cortex stimulodetection. fMRI investigated systematically motor tasks of both hands and that related to the somatic area (foot or tongue) affected by pain. fMRI data were analyzed with the Statistical Parametric Mapping99 software (initial analysis threshold [AT] corresponding to P < .001), registered in the neuronavigation system and correlated intraoperatively with iCM. Matching of fMRI and iCM was specifically examined, focusing the study on hand mapping. RESULTS: Concordance between contours of fMRI activation area and iCM in precentral gyrus (mean distance, 3.8 mm) was found in 20/21 patients (95%). Because precision of iCM was suboptimal in 7 patients, concordance for more restrictive values of the AT (P < .0001) was found in only 13 of these 20 patients. Concordance was not found in one patient, as result of image distortion and residual motion artifact. CONCLUSIONS: In this study, fMRI guidance provides information that matches those of an independent functional method. These data illustrate the functional accuracy of fMRI guidance for the operative targeting of selective motor cortex areas in neuropathic pain.


Assuntos
Mapeamento Encefálico , Imageamento por Ressonância Magnética , Córtex Motor/fisiopatologia , Doenças do Sistema Nervoso/complicações , Dor/fisiopatologia , Dor/cirurgia , Técnicas Estereotáxicas , Adulto , Idoso , Estimulação Encefálica Profunda , Estimulação Elétrica , Potenciais Somatossensoriais Evocados , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Neuronavegação , Dor/etiologia
9.
Eur J Radiol ; 74(3): 529-35, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19375256

RESUMO

PURPOSE: To prospectively evaluate a new imaging sequence (4D THRIVE) for whole liver perfusion in high temporal and spatial resolution. Feasibility of parametric mapping and its potential for characterizing focal liver lesions (FLLs) are investigated. MATERIALS AND METHODS: Fifteen patients suspected for colorectal liver metastases (LMs) were included. Parametric maps were evaluated qualitatively (ring-enhancement and lesion heterogeneity) and compared to three-phased contrast-enhanced MRI. Quantitative analysis was based on average perfusion values of entire FLLs. Reference standard comprised surgery with histopathology or follow-up imaging. Fisher's exact test was used for qualitative and Kruskal-Wallis test for quantitative analysis. RESULTS: In total 29 LMs, 17 hemangiomas and 4 focal nodular hyperplasias were evaluated. FLLs could be differentiated by qualitative assessment of parametric maps respectively three-phased contrast-enhanced MRI (Fisher's p<0.001 for comparisons between LMs and hemangiomas and LMs and FNHs for both ring-enhancement and lesion heterogeneity) rather than by quantitative analysis of parametric maps (Chi-square for Kep=0.33 (p=0.847) and Chi-square for Kel=1.35 (p=0.509)). CONCLUSION: This preliminary study shows potential of 4D THRIVE for whole liver imaging enabling calculation of parametric maps. Qualitative rather than quantitative analysis was accurate for differentiating malignant and benign FLLs.


Assuntos
Algoritmos , Neoplasias Colorretais/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Angiografia por Ressonância Magnética/métodos , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Magn Reson Imaging ; 29(1): 141-5, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19097115

RESUMO

PURPOSE: To compare an automated scan planning method to manual scan positioning in routine knee magnetic resonance imaging (MRI) studies. MATERIALS AND METHODS: The automated scan planning method uses anatomical landmarks in a 3D survey of the knee. The method is trained by example plannings, consisting of manual slice positioning by an experienced technologist in 15 MRI studies. Automated knee MR examinations obtained in three geometries in 50 consecutive patients were compared to those obtained in 50 consecutive control patients, where imaging planes were planned manually. Anatomical coverage and slice angulation were scored for each geometry on a 4-grade scale by an experienced radiologist blinded to the way of planning; groups were compared using a Mann-Whitney U-test. RESULTS: In 150 automated sequences the technologist adapted slice positioning in four cases (addition of slices to adapt to the size of the knee), representing the only automated sequences that received a poor rating. Thirteen sequences with manual planning received a poor rating. No difference in quality was found (P > 0.05) between automated and manual plannings for coronal coverage, sagittal coverage and angulation, and transverse angulation. Rating of automated planning was higher for transverse coverage, but lower than manual planning for coronal angulation. CONCLUSION: Automated sequence prescription for knee MRI is feasible in clinical practice, with similar quality as manual positioning.


Assuntos
Algoritmos , Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Neurosurgery ; 62(6 Suppl 3): 941-56, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18695580

RESUMO

OBJECTIVE: To evaluate, regardless of the clinical results, the contribution of combining functional magnetic resonance imaging (fMRI) with intraoperative cortical brain mapping (iCM) as functional targeting methods for epidural chronic motor cortex stimulation (MCS) in refractory neuropathic pain. METHODS: Eighteen neuropathic pain patients (central stroke in six; trigeminal neuropathy in six; syrinx or amputation in six) who underwent operations for epidural MCS were studied with preoperative fMRI and iCM. fMRI investigated motor tasks of hands (as well as foot and tongue, when painful). fMRI data were analyzed with Statistical Parametric Mapping99 software (University College London, London, England; initial analysis threshold corresponding to P < 0.001), registered in a neuronavigation system, and correlated during surgery with iCM. The primary aim of this study was to improve the topographical precision of MCS. Matching of fMRI and iCM specifically was examined. RESULTS: Correspondence between the contour of the fMRI activation area and iCM in precentral gyrus (mean distance, 3.8 mm) was found in 17 (94%) of 18 patients. Eleven of them showed correspondence for more restrictive values of the analysis threshold (P < 0.0001); in six patients, the quality of the iCM was reduced by somatosensory wave attenuation and general anesthesia. In this group of six patients, a combination of both techniques was used for the final targeting. Correspondence was not found in one patient as the result of image distortion and residual motion artifact. At follow-up (4-60 mo), MCS induced significant pain relief in a total of 11 patients (61%). CONCLUSION: This study confirms the functional accuracy of fMRI guidance in neuropathic pain and illustrates the usefulness of combining fMRI guidance with iCM to improve the functional targeting in MCS. Because appropriate targeting is crucial to obtaining pain relief, this combination may increase the analgesic efficacy of MCS.

12.
J Magn Reson Imaging ; 24(5): 989-94, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17031832

RESUMO

PURPOSE: To evaluate in brain gliomas the relationship between tumor vascularity measured by MR-based maximum regional cerebral blood volume (rCBV) and tumor amino-acid metabolism based on maximum carbon-11 methionine (MET) uptake on positron emission tomography (PET). MATERIALS AND METHODS: Eighteen patients with histologically proven primary brain gliomas were included in the study. In addition to conventional MR sequences, dynamic MR images, including a first-pass gadopentetate dimeglumine T2*-weighted echo-planar perfusion sequence and a PET study using MET, were acquired. Eleven patients had low-grade gliomas, and seven had high-grade gliomas. rCBV ratios and MET uptake ratios normalized to the contralateral white matter (WM) corresponding values were measured in each tumor. Both maximum rCBV ratios and maximum MET uptake ratios were correlated to histopathology. The maximum rCBV ratios were correlated to the maximum MET uptake ratios. RESULTS: Both the maximum rCBV ratios and maximum MET uptake ratios of high-grade gliomas were significantly higher than those of low-grade gliomas (P<0.05). There was a significant positive correlation between maximum rCBV ratios and maximum MET uptake ratios (Spearman: r=0.89, P<0.00001). CONCLUSION: The maximum rCBV ratio and maximum MET uptake ratio are significantly correlated in gliomas, reflecting a close link between amino acid uptake and vascularity in these tumors.


Assuntos
Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/metabolismo , Glioma/irrigação sanguínea , Glioma/metabolismo , Imageamento por Ressonância Magnética/métodos , Metionina/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Neoplasias Encefálicas/diagnóstico , Circulação Cerebrovascular , Meios de Contraste , Feminino , Glioma/diagnóstico , Humanos , Masculino , Metionina/farmacocinética , Pessoa de Meia-Idade , Projetos Piloto , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
13.
Magn Reson Med ; 54(4): 937-54, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16155898

RESUMO

RF spoiling is a well established method to produce T(1)-weighted images with short repetition-time gradient-echo sequences, by eliminating coherent transverse magnetization with appropriate RF phase modulation. This paper presents 2 novel approaches to describe signal formation in such sequences. Both methods rely on the formulation of RF spoiling as a linear increase of the precession angle between RF pulses, which is an alternative to the commonly used quadratic pulse phase scheme. The first technique demonstrates that a steady state signal can be obtained by integrating over all precession angles within the voxel, in spite of the lack of a genuine steady-state for separate isochromats. This clear mathematical framework allows a straightforward incorporation of off-resonance effects and detector phase settings. Moreover, it naturally introduces the need for a large net gradient area per repetition interval. In the second step, a modified partition method including RF spoiling is developed to obtain explicit expressions for all signal components. This provides a physical interpretation of the deviations from ideal spoiling behavior in FLASH and echo-shifted sequences. The results of the partition method in the small flip angle regime are compared with numerical simulations based on a Fourier decomposition of magnetization states. Measurements performed with in vitro solutions were in good agreement with numerical simulations at short relaxation times (T(1)/TR = 32 and T(2)/TR = 4); larger deviations occurred at long relaxation times (T(1)/TR = 114 and T(2)/TR = 82).


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Processamento de Sinais Assistido por Computador , Simulação por Computador , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Neurosurgery ; 56(2 Suppl): 344-59; discussion 344-59, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15794831

RESUMO

OBJECTIVE: To evaluate, regardless of the clinical results, the contribution of combining functional magnetic resonance imaging (fMRI) with intraoperative cortical brain mapping (iCM) as functional targeting methods for epidural chronic motor cortex stimulation (MCS) in refractory neuropathic pain. METHODS: Eighteen neuropathic pain patients (central stroke in six; trigeminal neuropathy in six; syrinx or amputation in six) who underwent operations for epidural MCS were studied with preoperative fMRI and iCM. fMRI investigated motor tasks of hands (as well as foot and tongue, when painful). fMRI data were analyzed with Statistical Parametric Mapping99 software (University College London, London, England; initial analysis threshold corresponding to P < 0.001), registered in a neuronavigation system, and correlated during surgery with iCM. The primary aim of this study was to improve the topographical precision of MCS. Matching of fMRI and iCM specifically was examined. RESULTS: Correspondence between the contour of the fMRI activation area and iCM in precentral gyrus (mean distance, 3.8 mm) was found in 17 (94%) of 18 patients. Eleven of them showed correspondence for more restrictive values of the analysis threshold (P < 0.0001); in six patients, the quality of the iCM was reduced by somatosensory wave attenuation and general anesthesia. In this group of six patients, a combination of both techniques was used for the final targeting. Correspondence was not found in one patient as the result of image distortion and residual motion artifact. At follow-up (4-60 mo), MCS induced significant pain relief in a total of 11 patients (61%). CONCLUSION: This study confirms the functional accuracy of fMRI guidance in neuropathic pain and illustrates the usefulness of combining fMRI guidance with iCM to improve the functional targeting in MCS. Because appropriate targeting is crucial to obtaining pain relief, this combination may increase the analgesic efficacy of MCS.


Assuntos
Mapeamento Encefálico , Terapia por Estimulação Elétrica , Imageamento por Ressonância Magnética , Monitorização Intraoperatória , Córtex Motor/fisiopatologia , Neuralgia/terapia , Neuronavegação , Adulto , Idoso , Terapia por Estimulação Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neuralgia/fisiopatologia , Cuidados Paliativos , Estudos Retrospectivos , Resultado do Tratamento
15.
Magn Reson Med ; 51(1): 123-34, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14705052

RESUMO

Echo-shifted sequences have been shown to be useful in applications where strong T*2-weighting and short repetition times are wanted, such as BOLD-contrast fMRI, MR thermometry, and perfusion studies. However, a full understanding of signal formation with such methods, which is mandatory to optimize sequence parameters for particular applications, has still not been achieved. Here, two methods are proposed to calculate the steady-state signal intensity in coherent TR-periodic and TR-shifted gradient-echo sequences. The integration method, which consists of averaging the steady-state magnetization over all isochromats in a voxel, is shown to be a particularly efficient way of obtaining the analytical expression of the measurable signal. The partition method, based on a physical decomposition of the steady-state magnetization into a sum of contributions from past excitation pulses, reveals that the net transverse magnetization results from a destructive interference between the wanted component and a series of stimulated echoes. The analysis includes off-resonance effects and is illustrated by phantom measurements. Relationships with previous publications on this subject are discussed.


Assuntos
Imagem Ecoplanar/métodos , Processamento de Sinais Assistido por Computador , Aumento da Imagem/métodos , Imagens de Fantasmas
16.
Magn Reson Med ; 50(1): 132-44, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12815688

RESUMO

A new approach to mixed T(2)- and T(2) (*)-weighted BOLD fMRI is presented, which combines T(2) magnetization preparation (T2prep) with a series of EPI readouts. This technique allows full 3D, time-efficient imaging to be performed with low RF power deposition. Steady-state calculations are performed in order to study signal formation in 3D T2prep-EPI sequences. Results obtained under the hypothesis of ideal spoiling are compared to full Bloch equation solutions. The theoretical findings are validated by means of in vitro and in vivo signal measurements. Several variants of the 3D T2prep-EPI approach are shown to be usable for visual cortex fMRI and compared to conventional 3D coherent gradient-echo EPI. The relative sensitivity of these sequences is shown to be predictable by means of a simple DeltaT(2)/DeltaT(2) (*) model.


Assuntos
Encéfalo/anatomia & histologia , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional , Modelos Biológicos , Processamento de Sinais Assistido por Computador , Técnica de Subtração , Encéfalo/fisiologia , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA