Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(6): 1196-1202, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38590268

RESUMO

INTRODUCTION: Ventricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years. METHODS: We performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed. RESULTS: A total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5-297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545  (IQR 152-1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39-2.64, p < .001). CONCLUSION: Following LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre-implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Implantação de Prótese , Taquicardia Ventricular , Função Ventricular Esquerda , Humanos , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Idoso , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Medição de Risco , Potenciais de Ação , Frequência Cardíaca , Adulto
2.
Am Heart J ; 263: 141-150, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37271358

RESUMO

BACKGROUND: Adults with repaired tetralogy of Fallot (TOF) have right atrial (RA) remodeling and dysfunction, and RA function can be measured using speckle tracking echocardiography. There are limited data about the role of RA strain imaging for risk stratification in this population. We hypothesized that RA reservoir strain can identify TOF patients at risk of developing atrial arrhythmia. To test this hypothesis, we assessed the relationship between RA reservoir strain and atrial arrhythmias in adults with repaired TOF. METHOD: Retrospective cohort study of adults with repaired TOF, and no prior history of atrial arrhythmias. Atrial arrhythmia was defined as atrial fibrillation, atrial flutter/atrial tachycardia, and categorized as new-onset versus recurrent atrial arrhythmias. RESULTS: We identified 426 patients (age 33 ± 12 years; males 208 (49%)) that met the inclusion criteria. The mean RA reservoir strain, conduit strain, and booster strain were 34 ± 11%, 20 ± 9%, and 15 ± 12%, respectively. Of 426 patients, 73 (17%) developed new-onset atrial arrhythmias (atrial flutter/tachycardia n = 42; atrial fibrillation n = 31); annual incidence 1.9%. RA reservoir strain was associated with new-onset atrial arrhythmias (adjusted HR 0.95, 95% CI 0.93-0.97) after multivariable adjustment. Of 73 patients with new-onset atrial arrhythmia, 41 (56%) had recurrent atrial arrhythmia (atrial flutter/tachycardia n = 18; atrial fibrillation n = 23); annual incidence 11.2%. Similarly, RA reservoir strain was associated with recurrent atrial arrhythmias (adjusted HR 0.92, 95% CI 0.88-0.96) after multivariable adjustment. CONCLUSIONS: RA strain indices can identify patients at risk for atrial arrhythmias, and this can in turn, be used to guide the type/intensity of therapy in such patients.


Assuntos
Fibrilação Atrial , Flutter Atrial , Taquicardia Supraventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Flutter Atrial/epidemiologia , Flutter Atrial/etiologia , Flutter Atrial/terapia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Taquicardia
3.
J Cardiovasc Electrophysiol ; 34(2): 438-444, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36579406

RESUMO

INTRODUCTION: A current limitation of single chamber implantable cardioverter defibrillators (ICDs) is the lack of an atrial lead to reliably detect atrial fibrillation (AF) episodes. A novel ventricular based atrial fibrillation (VBAF) detection algorithm was created for single chamber ICDs to assess R-R variability for detection of AF. METHODS: Patients implanted with Visia AF™ ICDs were prospectively enrolled in the Medtronic Product Surveillance Registry from December 15, 2015 to January 23, 2019 and followed with at least 30 days of monitoring with the algorithm. Time to device-detected daily burden of AF ≥ 6 min, ≥6 h, and ≥23 h were reported. Clinical actions after device-detected AF were recorded. RESULTS: A total of 291 patients were enrolled with a mean follow-up of 22.5 ± 7.9 months. Of these, 212 (73%) had no prior history of AF at device implant. However, 38% of these individuals had AF detected with the VBAF algorithm with daily burden of ≥6 min within two years of implant. In these 80 patients with newly detected AF by their ICD, 23 (29%) had a confirmed clinical diagnosis of AF by their provider. Of patients with a clinical diagnosis of AF, nine (39%) were newly placed on anticoagulation, including five of five (100%) patients having a burden >23 h. CONCLUSIONS: Continuous AF monitoring with the new VBAF algorithm permits early identification and actionable treatment for patients with undiagnosed AF that may improve patient outcomes.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Ventricular/etiologia
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37595138

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM. METHODS AND RESULTS: We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13-54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305-1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713-4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070-2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235-2.090; P < 0.001). CONCLUSIONS: Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Cardiomiopatia Hipertrófica , Fármacos Cardiovasculares , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos
5.
Cardiovasc Drugs Ther ; 37(1): 151-157, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34581901

RESUMO

PURPOSE: To evaluate the effect of single-dose intravenous dexamethasone on atrial fibrillation (AF) recurrence following radiofrequency catheter ablation. METHODS: A cohort of 84 adult patients (> 18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring within 3 months or between 3 and 12 months post-ablation with an in-person follow-up visit. RESULTS: A total of 31 (36.9%) patients received intravenous dexamethasone compared to 54 (63.1%) who did not (approximating a 2:1 comparison group). The incidence of documented AF or atrial flutter, lasting greater than 30 s, within the first 3 months post-ablation was 29.0% in the dexamethasone group versus 24.5% in the non-dexamethasone group (p value 0.80). AF or atrial flutter recurrence at 3-12 months post-ablation was 3.2% in the dexamethasone group compared to 9.4% in the non-dexamethasone group (p value 0.41). CONCLUSION: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis may not have a significant effect on AF recurrence rates.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Adulto , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Náusea e Vômito Pós-Operatórios/cirurgia , Ablação por Cateter/efeitos adversos , Doença Crônica , Esteroides
6.
Ann Noninvasive Electrocardiol ; 28(6): e13085, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37670480

RESUMO

The discrimination of ventricular tachycardia (VT) versus supraventricular wide complex tachycardia (SWCT) via 12-lead electrocardiogram (ECG) is crucial for achieving appropriate, high-quality, and cost-effective care in patients presenting with wide QRS complex tachycardia (WCT). Decades of rigorous research have brought forth an expanding arsenal of applicable manual algorithm methods for differentiating WCTs. However, these algorithms are limited by their heavy reliance on the ECG interpreter for their proper execution. Herein, we introduce the Mayo Clinic ventricular tachycardia calculator (MC-VTcalc) as a novel generalizable, accurate, and easy-to-use means to estimate VT probability independent of ECG interpreter competency. The MC-VTcalc, through the use of web-based and mobile device platforms, only requires the entry of computerized measurements (i.e., QRS duration, QRS axis, and T-wave axis) that are routinely displayed on standard 12-lead ECG recordings.


Assuntos
Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Eletrocardiografia/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico , Taquicardia Supraventricular/diagnóstico , Algoritmos
7.
Ann Noninvasive Electrocardiol ; 28(1): e13018, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36409204

RESUMO

BACKGROUND: Accurate automated wide QRS complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) can be accomplished using calculations derived from computerized electrocardiogram (ECG) data of paired WCT and baseline ECGs. OBJECTIVE: Develop and trial novel WCT differentiation approaches for patients with and without a corresponding baseline ECG. METHODS: We developed and trialed WCT differentiation models comprised of novel and previously described parameters derived from WCT and baseline ECG data. In Part 1, a derivation cohort was used to evaluate five different classification models: logistic regression (LR), artificial neural network (ANN), Random Forests [RF], support vector machine (SVM), and ensemble learning (EL). In Part 2, a separate validation cohort was used to prospectively evaluate the performance of two LR models using parameters generated from the WCT ECG alone (Solo Model) and paired WCT and baseline ECGs (Paired Model). RESULTS: Of the 421 patients of the derivation cohort (Part 1), a favorable area under the receiver operating characteristic curve (AUC) by all modeling subtypes: LR (0.96), ANN (0.96), RF (0.96), SVM (0.96), and EL (0.97). Of the 235 patients of the validation cohort (Part 2), the Solo Model and Paired Model achieved a favorable AUC for 103 patients with (Solo Model 0.87; Paired Model 0.95) and 132 patients without (Solo Model 0.84; Paired Model 0.95) a corroborating electrophysiology procedure or intracardiac device recording. CONCLUSION: Accurate WCT differentiation may be accomplished using computerized data of (i) the WCT ECG alone and (ii) paired WCT and baseline ECGs.


Assuntos
Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Eletrocardiografia/métodos , Diagnóstico Diferencial , Taquicardia Ventricular/diagnóstico
8.
J Cardiovasc Electrophysiol ; 33(2): 176-177, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34897873

RESUMO

Catheter ablation for atrial fibrillation has emerged as a mainstay for the management of atrial fibrillation. It has been shown to be clinically effective and cost-effective in multiple trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Análise Custo-Benefício , Humanos
9.
J Cardiovasc Electrophysiol ; 33(9): 2072-2080, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35870183

RESUMO

INTRODUCTION: Cardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS. OBJECTIVE: To determine if CRT improved cardiac remodeling in patients with CS. METHODS: We retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed. RESULTS: Our cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT-D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT-P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end-diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow-up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died. CONCLUSIONS: Our findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Desfibriladores Implantáveis , Insuficiência Cardíaca , Miocardite , Sarcoidose , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Cardiomiopatias/terapia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/etiologia , Estudos Retrospectivos , Sarcoidose/diagnóstico , Sarcoidose/terapia , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 33(5): 982-993, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35233867

RESUMO

AIMS: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. METHODS: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%. RESULTS: Sixty-five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4-wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. CONCLUSION: With the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.


Assuntos
Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Ecocardiografia , Átrios do Coração , Ventrículos do Coração , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 33(2): 274-283, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34911151

RESUMO

BACKGROUND: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. OBJECTIVE: To investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA). METHODS: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. RESULTS: In our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Forty-seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri-mitral area in six patients with VT and five patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. CONCLUSION: CA of VAs can be performed safely and effectively in patients with MVS.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/cirurgia
12.
Ann Noninvasive Electrocardiol ; 27(1): e12890, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34562325

RESUMO

BACKGROUND: Automated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification. METHODS: A derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one "all-inclusive" model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance. RESULTS: The VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X-lead QRS amplitude change, Y-lead QRS amplitude change, and Z-lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95). CONCLUSION: Custom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.


Assuntos
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Eletrocardiografia , Humanos , Modelos Logísticos , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
13.
J Electrocardiol ; 74: 32-39, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35933848

RESUMO

BACKGROUND: Timely and accurate discrimination of wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular WCT (SWCT) is critically important. Previously we developed and validated an automated VT Prediction Model that provides a VT probability estimate using the paired WCT and baseline 12-lead ECGs. Whether this model improves physicians' diagnostic accuracy has not been evaluated. OBJECTIVE: We sought to determine whether the VT Prediction Model improves physicians' WCT differentiation accuracy. METHODS: Over four consecutive days, nine physicians independently interpreted fifty WCT ECGs (25 VTs and 25 SWCTs confirmed by electrophysiological study) as either VT or SWCT. Day 1 used the WCT ECG only, Day 2 used the WCT and baseline ECG, Day 3 used the WCT ECG and the VT Prediction Model's estimation of VT probability, and Day 4 used the WCT ECG, baseline ECG, and the VT Prediction Model's estimation of VT probability. RESULTS: Inclusion of the VT Prediction Model data increased diagnostic accuracy versus the WCT ECG alone (Day 3: 84.2% vs. Day 1: 68.7%, p 0.009) and WCT and baseline ECGs together (Day 3: 84.2% vs. Day 2: 76.4%, p 0.003). There was no further improvement of accuracy with addition of the baseline ECG comparison to the VT Prediction Model (Day 3: 84.2% vs. Day 4: 84.0%, p 0.928). Overall sensitivity (Day 3: 78.2% vs. Day 1: 67.6%, p 0.005) and specificity (Day 3: 90.2% vs. Day 1: 69.8%, p 0.016) for VT were superior after the addition of the VT Prediction Model. CONCLUSION: The VT Prediction Model improves physician ECG diagnostic accuracy for discriminating WCTs.


Assuntos
Eletrocardiografia , Médicos , Humanos
14.
J Cardiovasc Electrophysiol ; 32(9): 2486-2495, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34314091

RESUMO

OBJECTIVE: Endomyocardial biopsy (EMB) is a useful diagnostic tool though the yield may be limited in many myocardial diseases. Data on the diagnostic yield and prognostic significance of EMB guided by abnormal electrograms (EGM-Bx) in suspected cardiac sarcoidosis (CS) are scarce. METHODS: Seventy-nine patients (mean age: 56 ± 12 years; 61% men) with suspected CS based on clinical and imaging features underwent right or left ventricular EGM-Bx guided by electroanatomic mapping. Tissue samples were obtained from sites with abnormal EGMs and/or abnormal cardiac imaging. The diagnostic yield of EGM-Bx was evaluated in reference to histopathologic analysis. Left ventricular assist device (LVAD) and transplantation-free survival were compared between patients with positive and negative EGM-Bx for CS. RESULTS: A total of 254 samples were obtained from abnormal EGM sites, and 126 samples from normal EGM sites guided by pre-procedure imaging findings. Abnormal histopathology was noted in 65 (26%) and 10 (8%) samples from abnormal and normal EGM sites, respectively. Histopathology confirmed CS in 16 (20%) patients, while an alternative tissue diagnosis emerged in 10 (13%) patients. Abnormal EGMs at the biopsy site had sensitivity 89% and specificity 33% for a histopathologic diagnosis of CS. LVAD and transplantation-free survival were not significantly associated with the EGM-Bx result (log-rank p = .91). CONCLUSION: In patients with suspected CS, abnormal EGM-Bx has high sensitivity and low specificity for establishing a definite CS diagnosis. Consideration of substrate abnormalities apparent on preprocedural imaging as an adjunct for selection of biopsy sites may further improve EGM-Bx yield.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Adulto , Idoso , Biópsia , Cateterismo Cardíaco , Cardiomiopatias/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sarcoidose/diagnóstico por imagem
15.
J Cardiovasc Electrophysiol ; 32(12): 3156-3164, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34664765

RESUMO

BACKGROUND: While ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients. METHODS: Our study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018. RESULTS: Of 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end-diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low-voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow-up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all-cause mortality at 1-year follow-up was 94%. CONCLUSION: Radiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.


Assuntos
Ablação por Cateter , Aneurisma Cardíaco , Infarto do Miocárdio , Taquicardia Ventricular , Adolescente , Idoso , Ablação por Cateter/efeitos adversos , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/cirurgia , Recidiva , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Resultado do Tratamento
16.
Europace ; 23(2): 247-253, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-32929501

RESUMO

AIMS: The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies. METHODS AND RESULTS: The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code-02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively. CONCLUSION: Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Hemorragia , Humanos , Masculino , Resultado do Tratamento
17.
J Electrocardiol ; 65: 50-54, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33503517

RESUMO

Accurate wide QRS complex tachycardia (WCT) differentiation into either ventricular tachycardia or supraventricular wide complex tachycardia using 12­lead electrocardiogram (ECG) interpretation is essential for diagnostic, therapeutic, and prognostic reasons. There is an ever-expanding variety of WCT differentiation methods and criteria available to clinicians. However, only a few make use of the diagnostic value of comparing the ECG during WCT to that of the patient's baseline ECG. Therefore, we highlight the conceptual rationale and scientific literature supporting the diagnostic value of WCT and baseline ECG comparison.


Assuntos
Taquicardia Supraventricular , Taquicardia Ventricular , Diagnóstico Diferencial , Eletrocardiografia , Humanos , Prognóstico , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico
18.
Lancet ; 394(10201): 861-867, 2019 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-31378392

RESUMO

BACKGROUND: Atrial fibrillation is frequently asymptomatic and thus underdetected but is associated with stroke, heart failure, and death. Existing screening methods require prolonged monitoring and are limited by cost and low yield. We aimed to develop a rapid, inexpensive, point-of-care means of identifying patients with atrial fibrillation using machine learning. METHODS: We developed an artificial intelligence (AI)-enabled electrocardiograph (ECG) using a convolutional neural network to detect the electrocardiographic signature of atrial fibrillation present during normal sinus rhythm using standard 10-second, 12-lead ECGs. We included all patients aged 18 years or older with at least one digital, normal sinus rhythm, standard 10-second, 12-lead ECG acquired in the supine position at the Mayo Clinic ECG laboratory between Dec 31, 1993, and July 21, 2017, with rhythm labels validated by trained personnel under cardiologist supervision. We classified patients with at least one ECG with a rhythm of atrial fibrillation or atrial flutter as positive for atrial fibrillation. We allocated ECGs to the training, internal validation, and testing datasets in a 7:1:2 ratio. We calculated the area under the curve (AUC) of the receiver operatoring characteristic curve for the internal validation dataset to select a probability threshold, which we applied to the testing dataset. We evaluated model performance on the testing dataset by calculating the AUC and the accuracy, sensitivity, specificity, and F1 score with two-sided 95% CIs. FINDINGS: We included 180 922 patients with 649 931 normal sinus rhythm ECGs for analysis: 454 789 ECGs recorded from 126 526 patients in the training dataset, 64 340 ECGs from 18 116 patients in the internal validation dataset, and 130 802 ECGs from 36 280 patients in the testing dataset. 3051 (8·4%) patients in the testing dataset had verified atrial fibrillation before the normal sinus rhythm ECG tested by the model. A single AI-enabled ECG identified atrial fibrillation with an AUC of 0·87 (95% CI 0·86-0·88), sensitivity of 79·0% (77·5-80·4), specificity of 79·5% (79·0-79·9), F1 score of 39·2% (38·1-40·3), and overall accuracy of 79·4% (79·0-79·9). Including all ECGs acquired during the first month of each patient's window of interest (ie, the study start date or 31 days before the first recorded atrial fibrillation ECG) increased the AUC to 0·90 (0·90-0·91), sensitivity to 82·3% (80·9-83·6), specificity to 83·4% (83·0-83·8), F1 score to 45·4% (44·2-46·5), and overall accuracy to 83·3% (83·0-83·7). INTERPRETATION: An AI-enabled ECG acquired during normal sinus rhythm permits identification at point of care of individuals with atrial fibrillation. FUNDING: None.


Assuntos
Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Eletrocardiografia/métodos , Redes Neurais de Computação , Adulto , Idoso , Algoritmos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
19.
J Cardiovasc Electrophysiol ; 31(4): 952-959, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32048387

RESUMO

INTRODUCTION: The ablation of outflow tract premature ventricular contractions (PVCs) is generally safe and effective. In some patients, successful ablation sites may not correlate with the earliest activation. We sought to evaluate mechanistic and anatomic relevance of the region below the left sinus of Valsalva in variable morphology outflow tract ventricular arrhythmias. METHODS: PVC cases where ablation was in the region inferior to the left sinus of Valsalva were identified. Procedural and demographic information and long-term outcomes were obtained. Cadaver dissections to evaluate regional anatomy were done as well. RESULTS: A total of 51 cases were included (age 53 ± 10; 37 [73%] males). Ablation was done for high PVC burden (>20%; mean 27% ± 8%) and presence of symptoms (73%) or ejection fraction less than 50% (78%). QRS morphology included either R wave (8; 16%), Rs (9; 18%), or rS (67%) in lead I, no precordial transition (40; 78%), V2 transition, (7; 14%), or V3 transition (4; 8%). In 31 (61%), the site just below the left coronary cusp was the earliest site, while the remainder had another site earlier. Ablation was acutely successful in 50 of 51 (98%). After 3 months, success was noted in 48 of 51 (94%). In two patients, repeat ablation in the same region resulted in durable suppression. CONCLUSION: The cases presented emphasize the importance of a region centered below the left sinus of Valsalva, where multivariable morphology QRS may be successfully ablated. Consideration of mapping and ablation even when signals are late in this region may be warranted in previously failed ablation attempts or first-line evaluation.


Assuntos
Potenciais de Ação , Ablação por Cateter , Frequência Cardíaca , Seio Aórtico/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Estudos Retrospectivos , Seio Aórtico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia
20.
J Cardiovasc Electrophysiol ; 31(12): 3106-3114, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32955151

RESUMO

INTRODUCTION: The need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined. METHODS AND RESULTS: Payment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in-depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165-$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik. CONCLUSION: Among cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.


Assuntos
Conflito de Interesses , Médicos , Idoso , Boston , Técnicas Eletrofisiológicas Cardíacas , Humanos , Medicare , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA