Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 44(5): 825-837, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28064343

RESUMO

PURPOSE: This study examined the feasibility of using quantitation to augment interpretation of florbetapir PET amyloid imaging. METHODS: A total of 80 physician readers were trained on quantitation of florbetapir PET images and the principles for using quantitation to augment a visual read. On day 1, the readers completed a visual read of 96 scans (46 autopsy-verified and 50 from patients seeking a diagnosis). On day 2, 69 of the readers reinterpreted the 96 scans augmenting their interpretation with quantitation (VisQ method) using one of three commercial software packages. A subset of 11 readers reinterpreted all scans on day 2 based on a visual read only (VisVis control). For the autopsy-verified scans, the neuropathologist's modified CERAD plaque score was used as the truth standard for interpretation accuracy. Because an autopsy truth standard was not available for scans from patients seeking a diagnosis, the majority VisQ interpretation of the three readers with the best accuracy in interpreting autopsy-verified scans was used as the reference standard. RESULTS: Day 1 visual read accuracy was high for both the autopsy-verified scans (90%) and the scans from patients seeking a diagnosis (87.3%). Accuracy improved from the visual read to the VisQ read (from 90.1% to 93.1%, p < 0.0001). Importantly, access to quantitative information did not decrease interpretation accuracy of the above-average readers (>90% on day 1). Accuracy in interpreting the autopsy-verified scans also increased from the first to the second visual read (VisVis group). However, agreement with the reference standard (best readers) for scans from patients seeking a diagnosis did not improve with a second visual read, and in this cohort the VisQ group was significantly improved relative to the VisVis group (change 5.4% vs. -1.1%, p < 0.0001). CONCLUSION: These results indicate that augmentation of visual interpretation of florbetapir PET amyloid images with quantitative information obtained using commercially available software packages did not reduce the accuracy of readers who were already performing with above average accuracy on the visual read and may improve the accuracy and confidence of some readers in clinically relevant cases.


Assuntos
Compostos de Anilina , Etilenoglicóis , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons , Idoso , Amiloide/metabolismo , Feminino , Humanos , Masculino , Software
2.
JAMA Neurol ; 78(4): 445-453, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33587110

RESUMO

Importance: Flortaucipir positron emission tomography (PET) scans, rated with a novel, US Food and Drug Administration-approved, clinically applicable visual interpretation method, provide valuable information regarding near-term clinical progression of patients with Alzheimer disease (AD) or mild cognitive impairment (MCI). Objective: To evaluate the association between flortaucipir PET visual interpretation and patients' near-term clinical progression. Design/Setting/Participants: Two prospective, open-label, longitudinal studies were conducted from December 2014 to September 2019. Study 1 screened 298 patients and enrolled 160 participants who had a flortaucipir scan at baseline visit. Study 2 selected 205 participants from the AMARANTH trial, which was terminated after futility analysis. Out of the 2218 AMARANTH participants, 424 had a flortaucipir scan around randomization, but 219 did not complete 18-month clinical dementia rating (CDR) assessments and thus were excluded. In both studies, all participants were diagnosed as clinically impaired, and they were longitudinally followed up for approximately 18 months after baseline. Main Outcomes and Measures: Flortaucipir scans were rated as either advanced or nonadvanced AD pattern using a predetermined visual interpretation method. The CDR sum of box (CDR-SB) score was used as primary clinical end point measurement in both studies. Results: Of the 364 study participants who had readable scans, 48% were female (n = 174 of 364), and the mean (SD) age was 71.8 (8.7) years. Two hundred forty participants were rated as having an advanced AD pattern. At 18 months follow-up, 70% of those with an advanced AD pattern (n = 147 of 210) had 1 point or more increase in CDR-SB, an event predefined as clinically meaningful deterioration. In contrast, only 46% of those with a nonadvanced AD pattern scan (n = 48 of 105) experienced the same event (risk ratio [RR], 1.40; 95% CI, 1.11-1.76; P = .005). The adjusted mean CDR-SB changes were 2.28 and 0.98 for advanced and nonadvanced AD pattern groups, respectively (P < .001). Analyses with other clinical end point assessments, as well as analyses with each individual study's data, consistently indicated a higher risk of clinical deterioration associated with an advanced AD scan pattern. Conclusions and Relevance: These results suggest that flortaucipir PET scans, when interpreted with an US Food and Drug Administration-approved, clinically applicable visual interpretation method, may provide valuable information regarding the risk of clinical deterioration over 18 months among patients with AD and MCI. Trial Registration: ClinicalTrials.gov Identifier: NCT02016560 and NCT03901105.


Assuntos
Doença de Alzheimer/metabolismo , Carbolinas/metabolismo , Disfunção Cognitiva/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Agregados Proteicos/fisiologia , Proteínas tau/metabolismo , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Meios de Contraste/metabolismo , Progressão da Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
3.
JAMA Neurol ; 77(7): 829-839, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32338734

RESUMO

Importance: Positron emission tomography (PET) may increase the diagnostic accuracy and confirm the underlying neuropathologic changes of Alzheimer disease (AD). Objective: To determine the accuracy of antemortem [18F]flortaucipir PET images for predicting the presence of AD-type tau pathology at autopsy. Design, Setting, and Participants: This diagnostic study (A16 primary cohort) was conducted from October 2015 to June 2018 at 28 study sites (27 in US sites and 1 in Australia). Individuals with a terminal illness who were older than 50 years and had a projected life expectancy of less than 6 months were enrolled. All participants underwent [18F]flortaucipir PET imaging, and scans were interpreted by 5 independent nuclear medicine physicians or radiologists. Supplemental autopsy [18F]flortaucipir images and pathological samples were also collected from 16 historically collected cases. A second study (FR01 validation study) was conducted from March 26 to April 26, 2019, in which 5 new readers assessed the original PET images for comparison to autopsy. Main Outcomes and Measures: [18F]flortaucipir PET images were visually assessed and compared with immunohistochemical tau pathology. An AD tau pattern of flortaucipir retention was assessed for correspondence with a postmortem B3-level (Braak stage V or VI) pathological pattern of tau accumulation and to the presence of amyloid-ß plaques sufficient to meet the criteria for high levels of AD neuropathological change. Success was defined as having at least 3 of the 5 readers above the lower bounds of the 95% CI for both sensitivity and specificity of 50% or greater. Results: A total of 156 patients were enrolled in the A16 study and underwent [18F]flortaucipir PET imaging. Of these, 73 died during the study, and valid autopsies were performed for 67 of these patients. Three autopsies were evaluated as test cases and removed from the primary cohort (n = 64). Of the 64 primary cohort patients, 34 (53%) were women and 62 (97%) were white; mean (SD) age was 82.5 (9.6) years; and 49 (77%) had dementia, 1 (2%) had mild cognitive impairment, and 14 (22%) had normal cognition. Prespecified success criteria were met for the A16 primary cohort. The flortaucipir PET scans predicted a B3 level of tau pathology, with sensitivity ranging from 92.3% (95% CI, 79.7%-97.3%) to 100.0% (95% CI, 91.0%-100.0%) and specificity ranging from 52.0% (95% CI, 33.5%-70.0%) to 92.0% (95% CI, 75.0%-97.8%). A high level of AD neuropathological change was predicted with sensitivity of 94.7% (95% CI, 82.7%-98.5%) to 100.0% (95% CI, 90.8%-100.0%) and specificity of 50.0% (95% CI, 32.1%-67.9%) to 92.3% (95% CI, 75.9%-97.9%). The FR01 validation study also met prespecified success criteria. Addition of the supplemental autopsy data set and 3 test cases, which comprised a total of 82 patients and autopsies for both the A16 and FR01 studies, resulted in improved specificity and comparable overall accuracy. Among the 156 enrolled participants, 14 (9%) experienced at least 1 treatment-emergent adverse event. Conclusions and Relevance: This study's findings suggest that PET imaging with [18F]flortaucipir could be used to identify the density and distribution of AD-type tau pathology and the presence of high levels of AD neuropathological change, supporting a neuropathological diagnosis of AD.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Tomografia por Emissão de Pósitrons/métodos , Idoso , Idoso de 80 Anos ou mais , Peptídeos beta-Amiloides/metabolismo , Autopsia , Carbolinas , Meios de Contraste , Feminino , Humanos , Masculino , Emaranhados Neurofibrilares/patologia , Neuroimagem/métodos , Placa Amiloide/diagnóstico por imagem , Placa Amiloide/patologia , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Proteínas tau/metabolismo
4.
J Am Coll Cardiol ; 61(4): 469-477, 2013 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-23265345

RESUMO

OBJECTIVES: This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) (≥50% stenosis) on invasive coronary angiography (ICA). BACKGROUND: In pre-clinical and phase I studies, flurpiridaz F 18 has shown characteristics of an essentially ideal MPI tracer. METHODS: One hundred forty-three patients from 21 centers underwent rest-stress PET and Tc-99m SPECT MPI. Eighty-six patients underwent ICA, and 39 had low-likelihood of CAD. Images were scored by 3 independent, blinded readers. RESULTS: A higher percentage of images were rated as excellent/good on PET versus SPECT on stress (99.2% vs. 88.5%, p < 0.01) and rest (96.9% vs. 66.4, p < 0.01) images. Diagnostic certainty of interpretation (percentage of cases with definitely abnormal/normal interpretation) was higher for PET versus SPECT (90.8% vs. 70.9%, p < 0.01). In 86 patients who underwent ICA, sensitivity of PET was higher than SPECT (78.8% vs. 61.5%, respectively, p = 0.02). Specificity was not significantly different (PET: 76.5% vs. SPECT: 73.5%). Receiver-operating characteristic curve area was 0.82 ± 0.05 for PET and 0.70 ± 0.06 for SPECT (p = 0.04). Normalcy rate was 89.7% with PET and 97.4% with SPECT (p = NS). In patients with CAD on ICA, the magnitude of reversible defects was greater with PET than SPECT (p = 0.008). Extensive safety assessment revealed that flurpiridaz F 18 was safe in this cohort. CONCLUSIONS: In this phase 2 trial, PET MPI with flurpiridaz F 18 was safe and superior to SPECT MPI for image quality, interpretative certainty, and overall CAD diagnosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Tomografia por Emissão de Pósitrons , Piridazinas , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Angiografia Coronária/métodos , Circulação Coronária , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/efeitos adversos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/métodos , Curva ROC , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
5.
J Nucl Med ; 52(9): 1490-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21849402

RESUMO

UNLABELLED: (18)F-labeled BMS747158 is a novel myocardial perfusion imaging tracer that targets mitochondrial complex 1. The objectives of this phase I study were to evaluate radiation dosimetry, biodistribution, human safety, tolerability, and early elimination of (18)F activity in urine after injection of a single dose of the tracer at rest in healthy subjects. METHODS: Thirteen healthy subjects were injected with 170-244 MBq (4.6-6.6 mCi) of BMS747158 intravenously. Dynamic PET was obtained over the heart for 10 min, followed by sequential whole-body imaging for 5 h. Blood samples and urinary excretion were collected for up to 8 h. Heart rate, electrocardiogram, and blood pressure were monitored before and during imaging. The residence times were determined from multiexponential regression of organ region-of-interest data normalized by injected dose. Absorbed dose estimates for all target organs were determined using MIRD schema with OLINDA/EXM software. RESULTS: The organ receiving the largest mean absorbed dose was the kidneys at 0.066 mSv/MBq (0.24 rem/mCi), followed by the heart wall at 0.048 mSv/MBq (0.18 rem/mCi). The mean effective dose was 0.019 mSv/MBq (0.072 rem/mCi). The heart exhibited high and sustained retention of BMS747158 from the earliest images through approximately 5 h after injection. There were no drug-related adverse events, and the tracer was well tolerated in all subjects. Mean urinary excretion was 4.83 percentage injected dose (range, 0.64-12.41 percentage injected dose). CONCLUSION: These preliminary data suggest that (18)F-labeled BMS747158 appears to be well tolerated and has a unique potential for myocardial perfusion PET.


Assuntos
Circulação Coronária/fisiologia , Coração/diagnóstico por imagem , Piridazinas , Compostos Radiofarmacêuticos , Adolescente , Adulto , Algoritmos , Eletroencefalografia , Feminino , Radioisótopos de Flúor/urina , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Piridazinas/administração & dosagem , Piridazinas/farmacocinética , Radiometria , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual , Contagem Corporal Total , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA