1.
J Environ Radioact ; 214-215: 106175, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32063292

RESUMO

In the present study, thoron exhalation flux density were measured in the soil samples collected around the Indian station namely Bharati (69° 24.41' S, 76° 11.72' E) and its nearby islands in the Larsemann hills region of Antarctica. Further, dependency of thoron mass emanation rate and emanation coefficient on the soil grain size was studied by segregating the soil samples into four different grain size groups: 50-100 µm, 100-200 µm, 200-500 µm and 500-1000 µm which showed that both of them follow a decreasing trend with increase in grain size. A comparison of measured mass emanation rate between different soil samples showed that it had a larger variation for the smaller grain size which eventually decreased as grain size increased while emanation coefficient was observed to be nearly constant for all the grain size groups. The variation in emanation coefficient with respect to mean grain size has been investigated and an empirical exponential model has been proposed for predicting emanation coefficient for different grain sizes.


Assuntos
Monitoramento de Radiação , Solo , Regiões Antárticas , Expiração , Radônio
2.
Radiat Prot Dosimetry ; 100(1-4): 251-3, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12382871

RESUMO

L3PO4:Mg,Cu, a low effective atomic number and high sensitivity TSL phosphor, has been prepared. Its TSL glow curve shows a major peak around 360 degrees C with minor peaks around 110 degrees C and 230 degrees C. The optimum concentrations of the dopants are found to be 200 ppm each. Its gamma sensitivity is 1.2 times as compared to CaSO4:Dy (0.1 mol%). The optimum preirradiation annealing treatment is found to be 650 degrees C, 15 min. Its PL emission shows a band at 370 nm with excitation band at 250 nm. Dose to TSL response shows that its response is linear up to the gamma dose of 100 Gy for irradiations carried out at RT. An irradiated sample shows a distinct new ESR signal, which is tentatively assigned to an electron/hole localised on one of the oxygen(s) of the phosphate group. Step annealing experiments show decay of the defect centre around 340 degrees C. This correlates well with the TSL peak around 360 degrees C.


Assuntos
Compostos de Lítio/efeitos da radiação , Fosfatos/efeitos da radiação , Dosimetria Termoluminescente/métodos , Cobre/química , Espectroscopia de Ressonância de Spin Eletrônica , Temperatura Alta , Compostos de Lítio/química , Medições Luminescentes , Magnésio/química , Fosfatos/química , Radioquímica
3.
Radiat Prot Dosimetry ; 140(2): 137-46, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20308052

RESUMO

In the present study, the energy dependence of response of some popular thermoluminescent dosemeters (TLDs) have been investigated such as LiF:Mg,Ti, LiF:Mg,Cu,P and CaSO(4):Dy to synchrotron radiation in the energy range of 10-34 keV. The study utilised experimental, Monte Carlo and analytical methods. The Monte Carlo calculations were based on the EGSnrc and FLUKA codes. The calculated energy response of all the TLDs using the EGSnrc and FLUKA codes shows excellent agreement with each other. The analytically calculated response shows good agreement with the Monte Carlo calculated response in the low-energy region. In the case of CaSO(4):Dy, the Monte Carlo-calculated energy response is smaller by a factor of 3 at all energies in comparison with the experimental response when polytetrafluoroethylene (PTFE) (75 % by wt) is included in the Monte Carlo calculations. When PTFE is ignored in the Monte Carlo calculations, the difference between the calculated and experimental response decreases (both responses are comparable >25 keV). For the LiF-based TLDs, the Monte Carlo-based response shows reasonable agreement with the experimental response.


Assuntos
Simulação por Computador , Método de Monte Carlo , Síncrotrons , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos