Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37470452

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel, largely nonthermal ablative modality that, by virtue of its putative preferential action on myocardial tissue through the process of irreversible electroporation (IRE), may replace conventional thermal ablation for atrial fibrillation (AF). The recent inspIRE study confirmed safety and effectiveness of a fully integrated biphasic PFA system with a variable loop circular catheter for the treatment of paroxysmal AF. The majority of PFA procedures were performed using general anesthesia. However, due to the risks of general anesthesia we report the data regarding our sedation protocol used during inspIRE study. METHODS: A total of 29 patients (mean age 55±9 years; 72% male) were enrolled as part of this analysis within the inspIRE trial. The sedation protocol is reported in the manuscript. The Richmond Agitation-Sedation Scale (RASS), the Visual Analogue Scale (VAS) and the Patient State Index were collected during sedation. Each patient was monitored using the Masimo Sedline. At the end of ablation, the Likert Scale Questionnaire (LSQ) was used to assess the patients' satisfaction with intraoperative analgesia-sedation. RESULTS: No procedural complications were documented. Sufficient oxygen saturation was maintained in all patients during procedure. Non-invasive ventilation or tracheal intubation were not required for any patient. The RAAS score between -1 to -5 was obtained in 27 patients (93%) while the value 0 was obtained in 2 patients (7%). The VAS score between 0 to 2 was obtained in 24 patients (83%); the VAS score 3 in 3 patients (10%) and the VAS score 4 in 2 patients (7%). The PSI score <50 was achieved in 16 patients (55%) while the PSI between 50 and 70 was achieved in 9 patients (31%). Positive answers to LSQ were obtained in most patients. CONCLUSION: During PFA ablation procedures with the variable-loop circular catheter and its accompanying biphasic pulse, our deep sedation protocol is a valid alternative to general anesthesia.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Sedação Profunda , Veias Pulmonares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Frequência Cardíaca , Veias Pulmonares/cirurgia , Resultado do Tratamento
2.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-37988294

RESUMO

AIMS: Stereotactic arrhythmia radioablation (STAR) is a novel therapeutic approach for cardiac arrhythmias. The aim of this trial is to investigate the feasibility of STAR for the treatment of paroxysmal atrial fibrillation (AF) in elderly patients. METHODS AND RESULTS: Inclusion criteria were age >70 years, symptomatic AF, antiarrhythmic drugs failure, or intolerance. All patients underwent to 4D cardiac computed tomography simulation. The clinical target volume was identified in the area around pulmonary veins (PV). Stereotactic arrhythmia radioablation was performed with a total dose of 25 Gy (single fraction) delivered in 3 min. Twenty patients were enrolled and 18 underwent STAR. One patient withdrew informed consent before treatment and one patient was excluded due to unfavourable oesophagus position. With a median follow-up (FU) of 16 months (range 12-23), no acute toxicity more than Grade 3 was reported. Five patients had a Grade 1 oesophagitis 24 h after STAR; eight patients had an asymptomatic Grade 1 pericardial effusion, and one patient had a torsade de pointes treated effectively by electrical cardioversion and subsequent cardiac implantable cardioverter-defibrillator implantation. Most patients had a significant reduction in AF episodes. Five patients, due to arrhythmias recurrences after STAR, performed electrophysiological study documenting successful PV isolation. Finally, a significant improvement of quality of life was documented (48 ± 15 at enrolment vs. 75 ± 15 at 12 months FU; P < 0.001). CONCLUSION: The present phase II trial demonstrated the feasibility of STAR in paroxysmal AF elderly patients and its potential role in increasing the quality of life. Surely, more robust data are needed about safety and efficacy. TRIAL REGISTRATION: ClinicalTrials.gov: NCT04575662.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Qualidade de Vida , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Aceleradores de Partículas , Recidiva
3.
Radiol Med ; 126(1): 155-162, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32405924

RESUMO

AIM: Stereotactic ablative radiation therapy (SABR) is used in non-oncologic indications, recently even for cardiac arrhythmias. Thus, aim of this analysis is to review preclinical, early clinical evidences and future direction of the latter new treatment approach. METHOD: A collection of available data regarding SABR and cardiac arrhythmias was made, by Pubmed research and 2 independent researchers, including preclinical and clinical data. A review of ongoing trials was conducted on ClinicalTrials.gov. RESULTS: Preclinical research conducted in animal models showed that a safe and effective noninvasive treatment approach for cardiac arrhythmias could be represented by SABR with a median time of response around 2-3 months. The treatment dose plays a crucial role: the atrioventricular node would seem more radiosensitive than the other cardiac electric zones. Clinical data, such as published case series, case reports and early prospective studies, have already suggested the feasibility, efficacy and safety of SABR (25 Gy in one session) for refractory ventricular arrhythmias. CONCLUSION: Considering the ongoing trials of SABR and new technological improvements in radiotherapy (e.g. hybrid magnetic resonance) and in arrhythmias noninvasive mapping systems, the future analyses will improve the reliability of those preliminary results.


Assuntos
Arritmias Cardíacas/radioterapia , Radiocirurgia/métodos , Humanos
4.
J Cardiovasc Electrophysiol ; 31(10): 2607-2613, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32700436

RESUMO

INTRODUCTION: Technological advancement in the setting of atrial fibrillation (AF) ablation has decreased radiation exposure and complications associated with the procedure. Yet, transseptal puncture (TSP) remains a challenging step that necessitates accurate guidance. We describe our experience performing TSP under electroanatomic (EA) guidance. METHODS AND RESULTS: The analysis included 145 consecutive EA-guided ablation procedures performed between June 2018 and April 2019 and 145 consecutive standard ablations performed before June 2018. EA guidance utilized the CARTO 3 three-dimensional mapping system to reconstruct anatomic and electrical characteristics of the right atrium and fossa ovalis. Patients with a history of previous cardiac surgery were excluded. For EA-guided procedures, the mean patient age was 60 ± 10 years, 75.2% were male, and 69.0% had paroxysmal AF. Similarly, the mean age for conventional procedures was 60 ± 11 years, 71.0% were male, and 71.7% had paroxysmal AF. The fossa ovalis was detected as a region of low voltage, <0.75 mV. EA guidance yielded shorter fluoroscopy times (EA vs. conventional, 3.6 ± 2.5 vs. 13.5 ± 10.5 min; p < .001) and a lower dose area product than conventional guidance (13 ± 11 Gy* cm2 vs. 28 ± 27 Gy* cm2 ; p < .001). The total procedure duration was similar between groups (146 ± 48 vs. 148 ± 54 min). There were no significant complications related to TSP. CONCLUSION: During AF ablation, TSP with EA guidance facilitated safe access to the left atrium while reducing radiation risk to both patients and operators.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criança , Fluoroscopia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Punções , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 31(6): 1259-1269, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32250514

RESUMO

BACKGROUND: The RADIANCE first-in-man study evaluated acute (3-month) safety and design concept in terms of utility of a new multi-electrode radiofrequency (RF) balloon catheter (HELIOSTAR, Biosense Webster) to achieve pulmonary vein isolation (PVI). After study conclusion, a subset of patients was followed up to 12 months. METHODS: Patients with drug refractory paroxysmal atrial fibrillation were enrolled. Neurological assessment, cardiac and cerebral magnetic resonance imagings were performed pre and post procedure. Ablation was delivered at 15 Watts to each PV for 60 seconds (electrodes adjacent to the posterior wall limited to 20 seconds). Adenosine or isoproterenol was administered to confirm PVI. Esophageal endoscopy was performed 48 hours post procedure. Patients were clinically followed up for 12 months. RESULTS: Thirty-nine patients underwent catheter ablation from four centers. Mean age was 60.7 ± 10.0 years with 23 (57.5%) being male. Confirmation of PVI was performed in all PVs treated (152/152). Confirmation of isolation after one delivery was performed solely on 137 of 152 PVs of which 79.6% (109/137) achieved isolation with a single delivery of RF energy. Acute PV reconnection was seen in 4.6% (7/150) of PVs. Freedom from documented atrial arrhythmia at 12 months in those followed up was 86.4% (32/37). A total of 75.7% (28/37) of patients were free from atrial arrhythmia and off antiarrhythmic medications. CONCLUSION: The HELIOSTAR RF balloon catheter allows for rapid and safe PVI with majority of PVs only requiring one application.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Eletrodos , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Europa (Continente) , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Sistema de Registros , Fatores de Tempo
6.
J Cardiovasc Electrophysiol ; 30(8): 1281-1286, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31111583

RESUMO

INTRODUCTION: Catheter ablation is an important treatment option for sustained ventricular arrhythmias (VA) that are refractory to pharmacological treatment; however, patients with fast VA or electrical storm (ES) are at risk for cardiogenic shock. We report our experience using cardiopulmonary support with extracorporeal membrane oxygenation (ECMO) during catheter ablation of VA. METHODS: Nineteen patients (mean age, 62 ± 10 years; 84% male) were referred to our center for CA of ES between January 2017 and April 2018. ES was defined as the occurrence of ≥3 ventricular tachycardia or ventricular fibrillation episodes requiring electrical cardioversion or defibrillation in a 24-hour period. ECMO support was implemented for all patients. RESULTS: CA of ES was completed in all patients. Activation mapping was performed for all VTs and substrate modification was performed by targeting sites identified by late/fragmented abnormal potentials. VTs were not inducible after ablation in 16 of 19 patients (84%). With regard to procedural complications, two patients underwent percutaneous angioplasty with stenting for a femoral artery dissection and one patient was treated for a dislodged ECMO arterial cannula and subsequent hemorrhagic shock. After a median follow-up of 10 months, three patients died from refractory heart failure and one patient died as a result of ES. Overall, the procedural success rate was 68% and the Kaplan-Meier mortality rate was 21%. CONCLUSIONS: ECMO support may be used for ablation procedures in patients with ES.


Assuntos
Ablação por Cateter , Oxigenação por Membrana Extracorpórea , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
7.
J Cardiovasc Electrophysiol ; 28(7): 762-767, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28422368

RESUMO

INTRODUCTION: Pulmonary vein (PV) isolation is the cornerstone of catheter ablation in patients with atrial fibrillation (AF). Surround flow and contact force (CF) measurement capabilities might enhance procedure efficacy and safety. We report on the safety and midterm efficacy of a novel ablation catheter for PV isolation in patients with AF. METHODS AND RESULTS: Two hundred thirty-three consecutive patients (57 ± 11 years, 76% males, 51% with structural heart disease), referred for paroxysmal (157) or persistent (76) AF, underwent PV isolation by a surround flow catheter with CF measurement capability in four centers. Ablation was guided by electroanatomic mapping allowing radiofrequency (RF) energy delivery in the antral region aiming at PV isolation. Mean overall procedure time was 100 ± 42 minutes with a mean fluoroscopy time of 6 ± 5 minutes. Mean ablation time was 31±15 minutes; 99% of the targeted veins were isolated. The mean CF value during ablation was 13 ± 4 g. Intraprocedural early (30 minutes) PV reconnection occurred in 12% PVs, and all PVs were effectively reisolated. One pericardial effusion and five groin hematomas were reported. During a mean follow-up of 12 ± 6 months, 30 (12.9%) (10% paroxysmal AF vs. 18% persistent AF, P = 0.07) patients had an atrial arrhythmias recurrence. CONCLUSIONS: In this multicenter registry, RF ablation using a new surround flow catheter, with CF sensor, resulted as feasible, achieving a high rate of isolated PVs. Procedural and fluoroscopy times and success rates were comparable with other techniques with a low complication rate.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Sistema de Registros , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
8.
Europace ; 19(3): 432-440, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27025772

RESUMO

AIMS: The number of cardiovascular implantable electronic devices has increased progressively, leading to an increased need for transvenous lead extraction (TLE) due to device infections. Previous studies described 'ghost' as a post-removal, new, tubular, mobile mass detected by echocardiography following the lead's intracardiac route in the right-sided heart chambers, associated with diagnosis of cardiac device-related infective endocarditis. We aimed to analyse the association between 'ghosts' assessed by transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) and mortality in patients undergoing TLE. METHODS AND RESULTS: We prospectively enrolled 217 patients (70 ± 13 years; 164 males) undergoing TLE for systemic infection (139), local device infection (67), and lead malfunction (11). All patients underwent TEE before and 48 h after TLE and ICE during TLE. Patients were allocated to two groups: either with (Group 1) or without (Group 2) post-procedural 'ghost'. Mid-term clinical follow-up was obtained in all patients (11 months, IQR 1-34 months). We identified 30 (14%) patients with 'ghost', after TLE. The significant predictors of 'ghost' were Charlson co-morbidity index (HR = 1.24, 95% CI 1.04-1.48, P = 0.03) and diagnosis of endocarditis assessed by ICE (HR = 1.82, 95% CI 1.01-3.29, P = 0.04). Mortality was higher in Group 1 than in Group 2 (28 vs. 5%; log-rank P < 0.001). Independent predictors of mid-term mortality were the presence of 'ghost' and systemic infection as the clinical presentation of device infection (HR = 3.47, 95% CI 1.18-10.18, P = 0.002; HR = 3.39, 95% CI 1.15-9.95, P = 0.001, respectively). CONCLUSION: The presence of 'ghost' could be an independent predictor of mortality after TLE, thus identifying a subgroup of patients who need closer clinical surveillance to promptly detect any complications.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/mortalidade , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/mortalidade , Falha de Prótese , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Circ J ; 80(3): 613-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26821688

RESUMO

BACKGROUND: Not all heart failure (HF) patients benefit from cardiac resynchronization therapy (CRT). We assessed whether choosing the site of left ventricular (LV) pacing by a quadripolar lead may improve response to CRT. METHODS AND RESULTS: We prospectively randomized 23 patients with HF (67±11 years; 21 males) to CRT with a quadripolar LV lead (group 1, with the LV pacing site chosen on the basis of QRS shortening using simultaneous biventricular pacing), and 20 patients (71±6 years; 16 males) to a bipolar LV lead (group 2, with devices programmed with a conventional tip-to-ring configuration). New York Heart Association (NYHA) class and LV ejection fraction (EF) by 2D echocardiography were assessed at baseline and after 3 months. The baseline EF was not different between the 2 groups (25±6% group 1 vs. 27±3% group 2; P=0.22), but after 3 months EF was higher in group 1 (35±13% group 1 vs. 31±4% group 2; P<0.001). A reduction in at least 1 NYHA class at 3 months was observed in 22 (96%) and 12 (60%) of group 1 and group 2 patients, respectively (P<0.05). CONCLUSIONS: CRT with a quadripolar LV lead was associated with an improvement of EF greater than that observed in patients receiving a bipolar LV lead. In devices with a quadripolar lead, CRT programming based on the best QRS shortening is reliable and effective. (Circ J 2016; 80: 613-618).


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
J Cardiovasc Electrophysiol ; 25(12): 1363-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25066621

RESUMO

BACKGROUND: Patients with severe structural heart disease have increased mortality after implantable cardioverter-defibrillator (ICD) shocks. Whether this is limited to ICD shock therapy only or extends also to no-shock therapies, such as antitachycardia pacing (ATP), is unclear. We investigated the impact of different ICD therapies on long-term mortality. METHODS: We enrolled 573 patients who underwent ICD implantation at our institution from 2004 to 2011. The population was divided into 3 groups: no device interventions (group 1), ATP interventions (group 2), and shock interventions (group 3). The endpoint was the all-cause mortality. RESULTS: Over a follow-up period of 48 months (range 1-110), 447 (78%) had no device interventions, 71 (12%) had ATP therapy only, and 55 (10%) had at least one shock intervention. All-cause mortality occurred in 94 patients in group 1 (21%), 23 patients (43%) in group 2, and 21 patients (38%) in group 3. At multivariable Cox regression analysis, ATP intervention (HR: 1.8; 95% CI 1.1-3; P < 0.001), shock intervention (HR: 1.39; 95% CI 1.09-1.77; P = 0.008), age (HR: 1.05; 95% CI 1.02-1.07; P < 0.001), and LVEF (HR: 0.95; 95% CI 0.93-0.98; P = 0.001) were predictors of all-cause mortality. No significant difference in mortality was found between group 2 and 3. CONCLUSION: Patients with ICDs who receive appropriate interventions are at increased risk of mortality. Such risk is not dependent on different types of ICD therapy, such as shocks or ATP. Our data suggest that sustained ventricular arrhythmias per se have a negative impact on prognosis rather than modality of ICD therapy.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/mortalidade , Insuficiência Cardíaca/mortalidade , Taquicardia Ventricular/prevenção & controle , Idoso , Comorbidade , Cardioversão Elétrica/instrumentação , Feminino , Insuficiência Cardíaca/prevenção & controle , Humanos , Incidência , Itália/epidemiologia , Masculino , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida , Taquicardia Ventricular/mortalidade , Resultado do Tratamento
11.
Europace ; 16(10): 1496-507, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24965015

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is a complex invasive procedure and the experience of the operator and the team is a major determinant of procedural outcomes. AIM: Because of very limited data available on minimum procedural volumes to enable training and ongoing competency for TLEs, we performed a meta-analysis aimed at assessing the outcomes of TLE in the centres with low, medium, and high volume of procedures. METHODS: Of the 280 papers initially retrieved until February 2013, 66 observational studies met inclusion criteria and were included in at least one stratified meta-analysis: 17 were prospective studies; 47 had a retrospective design; and 2 were defined 'experience studies'. We included only articles published after the introduction of laser technique (year 1999). We divided the studies in low, medium, and high volume centres utilizing either the European Heart Rhythm Association (EHRA) or Lexicon classification criteria. RESULTS: When meta-analyses were carried out separately for the studies with larger and smaller sample sizes, either using EHRA or Lexicon classification criteria, no clear differences emerged in the combined rate of major complications or intraoperative deaths. In contrast, both minor complications and mortality at 30 days decreased as centre volume increased. CONCLUSIONS: In our meta-analysis of observational studies, patients who have been treated in higher volume centres have a lower probability of minor complications and death at 30 days regardless of the infection rate, length of lead duration, type of device, and type of extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Segurança do Paciente , Veias , Humanos , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia
12.
J Cardiothorac Vasc Anesth ; 28(3): 512-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24094564

RESUMO

OBJECTIVE: To evaluate the preoperative presence of C-reactive protein (CRP) and troponin T(hs-TnT) in patients with coronary artery disease (CAD) undergoing cardiopulmonary bypass (CPB) in order to better clarify the role of atrial inflammation and/or myocardial ischemia in the development of postoperative atrial fibrillation (POAF). DESIGN: Prospective, nonrandomized study. SETTING: University hospital. PARTICIPANTS: Thirty-eight consecutive ischemic patients admitted to the authors' hospital for CAD undergoing elective on-pump coronary artery bypass grafting (CABG). INTERVENTION: Elective on-pump CABG. MEASUREMENTS AND MAIN RESULTS: Peripheral blood samples were collected from all patients before and 24 hours after CABG to assess high sensitive (hs)-CRP and troponin T (hs-TnT) levels. The patients' heart rhythm was monitored by continuous ECG telemetry. Biopsies from the right atrial appendage were obtained at the beginning of the CABG procedure in order to perform immunohistochemistry for CRP and reverse transcription polymerase chain reaction for CRP mRNA expression. Fourteen patients out of 38 (36%) developed POAF. Atrial CRP was found in 31 patients (82%), 10 with POAF and 21 with sinus rhythm (71% v 87% respectively, p = ns). None of the atrial samples was positive for CRP mRNA. Atrial CRP did not correlate with serum hs-CRP levels and with occurrence of POAF, but with the incidence of diabetes (p = 0.010). Postoperative hs-TnT levels, but not hs-CRP levels, were identified as the only predictor of POAF occurrence (p = 0.016). CONCLUSIONS: In patients undergoing CABG, neither peripheral nor tissue preoperative CRP levels, but only postoperative hs-TnT levels, correlated with POAF, suggesting the primary role of an ischemic trigger of atrial fibrillation.


Assuntos
Fibrilação Atrial/etiologia , Ponte Cardiopulmonar/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Inflamação/complicações , Isquemia Miocárdica/complicações , Miocardite/complicações , Complicações Pós-Operatórias/etiologia , Idoso , Fibrilação Atrial/epidemiologia , Proteína C-Reativa/análise , Feminino , Fibrinogênio/análise , Átrios do Coração/patologia , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Risco
13.
Am J Cardiol ; 218: 77-85, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38458580

RESUMO

Left atrial or left atrial appendage thrombosis (LAT) is contraindicated for cardiac ablation (CA) or cardioversion (CV) of atrial fibrillation (AF). This study was aimed to compare the frequency of LAT detected by transesophageal echocardiography (TEE) before CA or CV in patients with AF treated with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). We searched PubMed, Scopus, Web of Science, and Cochran Library databases from inception through July 13, 2023 to select studies reporting data on LAT identification before CA or CV using TEE in patients with AF treated with DOACs or VKAs. Pooled odds ratios (ORs) with 95% confidence interval were calculated with a random-effects model. Studies retrieved were 50 (38 observational), 29 on CA, 15 on CV, and 6 on both procedures (17,096 patients on DOACs and 13,666 on VKAs). The overall prevalence of LAT was smaller in DOACs than in VKAs, with an OR of 0.66 (0.52 to 0.84), confirmed at sensitivity analysis and in most subgroups. This finding was consistent for the 3 most reported DOACs: the pooled OR for LAT was 0.68 (0.50 to 0.90) in apixaban, 0.67 (0.51 to 0.88) in dabigatran, 0.61 (0.43 to 0.89) in rivaroxaban, and 1.10 (0.74 to 1.64) in edoxaban (not significant). In conclusion, in this large meta-analysis in patients with AF, the prevalence of LAT by TEE evaluation performed before CV or CA appears lower in those treated with DOACs than in those on VKAs. Additional research may help in better understanding differences between these classes of anticoagulant drugs in the setting of protection against AF-related left atrial thrombotic formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Fibrilação Atrial/epidemiologia , Cardioversão Elétrica , Prevalência , Anticoagulantes/uso terapêutico , Trombose/prevenção & controle , Cardiopatias/tratamento farmacológico , Vitamina K , Administração Oral , Acidente Vascular Cerebral/prevenção & controle
14.
Front Cardiovasc Med ; 11: 1370522, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38633841

RESUMO

Background: There are some functional bradyarrhythmias that are caused by a dysregulation of the autonomic nervous system, for which a therapeutic strategy of cardioneuroablation (CNA) is conceivable. Case summary: In this study, we report the case of a 19-year-old woman with a non-congenital third-degree atrioventricular block (AVB), symptomatic for lipothymia and dyspnea caused by mild exertion. She had a structurally normal heart and no other comorbidities. The atropine test and the exercise stress test documented a sinus tachycardia at 190 bpm with a 2:1 AVB, a narrow QRS, and an atrioventricular conduction of 1:1 until reaching a sinus rhythm rate of 90 bpm. She underwent the CNA procedure, which targeted the inferior paraseptal ganglion plexus, with a gradual change in the ECG levels recorded during the radiofrequency delivery from a third-degree AVB to a first-degree AVB. After the procedure, we observed a complete regression of the third-degree AVB, with evidence of only a first-degree AVB and a complete regression of symptoms until the 6-month follow-up. Conclusions: Although not yet included in current guidelines, the CNA procedure could be used to treat AV node dysfunction in young subjects, as it could represent an alternative to pacemaker implantation. However, more randomized studies are needed to assess the long-term efficacy of this promising technique.

15.
Clin Pract ; 14(3): 946-953, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38804407

RESUMO

BACKGROUND: Arrhythmias in pregnancy are complex to manage due to the teratogenic effects of many antiarrhythmic drugs and the common use of ionizing radiation during catheter ablation procedures. Furthermore, pregnant women are extremely vulnerable and difficult to treat because of the progressive physical and hormonal changes that occur during the nine months of pregnancy. CASE PRESENTATION: In this case report, we describe a complex clinical case of a 34-year-old pregnant woman who was affected by an incessant right atrial tachycardia, with signs and symptoms of initial hemodynamic instability. This tachycardia was refractory to antiarrhythmic drugs, so a zero-fluoroscopy ablation was performed. The first procedure was complicated by cardiac tamponade, quickly resolved without further complications for the mother or the fetus. In the following days, a deep venous thrombosis occurred at the femoral venous access. After a few days, the patient underwent a second procedure that was successful and resulted in the restoration of a sinus rhythm. CONCLUSIONS: The management of this clinical case was complex both from a procedural and a clinical (cardiological and gynecological) point of view. Finally, the integration of the various skills led to an excellent result.

16.
Int J Cardiol ; 379: 40-47, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-36907451

RESUMO

BACKGROUND: A systematic evaluation focused on efficacy and safety for electrical cardioversion of atrial fibrillation (AF) among different Direct Oral Anticoagulants (DOACs) has not been previously performed. In this setting, we conducted a meta-analysis of studies evaluating DOACs vs vitamin K antagonists (VKA) as common comparator. METHODS: We searched Cochrane Library, Pubmed, Web Of Science and Scopus databases for all English-only articles concerning studies that have estimated the effect of DOACs and VKA on stroke, transient ischemic attack or systemic embolism (SSE) and major bleeding (MB) events in AF patients undergoing electrical cardioversion. We selected 22 articles comprising 66 cohorts and 24,322 procedures (12,612 with VKA). RESULTS: During follow-up (studies' median 42 days), 135 SSE (52 DOACs and 83 VKA) and 165 MB (60 DOACs and 105 VKA) were recorded. The overall pooled effects, DOACs vs VKA, was estimated by an univariate Odds Ratio of 0.92 (0.63-1.33; p = 0.645) for SSE and 0.58 (0.41-0.82; p = 0.002) for MB; at bivariate evaluation, adjusting for study type, were respectively 0.94 (0.55-1.63; p = 0.834) and 0.63 (0.43-0.92, p = 0.016). Each single DOAC showed similar and non statistically different results in outcome occurrence compared to VKA as well as when Apixaban, Dabigatran, Edoxaban and Rivaroxaban were indirectly compared to each other. CONCLUSIONS: In patients undergoing electrical cardioversion, compared to VKA, DOACs have similar thromboembolic protection with lower major bleeding incidence. Single molecule does not show difference in event rate compared to each other. Our findings, provide useful information about safety and efficacy profile of DOACs and VKA.


Assuntos
Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Embolia/induzido quimicamente , Fibrinolíticos/uso terapêutico , Vitamina K , Administração Oral
17.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37103051

RESUMO

Ventricular tachycardia in patients with structural heart disease is a significant cause of morbidity and mortality. According to current guidelines, cardioverter defibrillator implantation, antiarrhythmic drugs, and catheter ablation are established therapies in the management of ventricular arrhythmias but their efficacy is limited in some cases. Sustained ventricular tachycardia can be terminated by cardioverter-defibrillator therapies although shocks in particular have been demonstrated to increase mortality and worsen patients' quality of life. Antiarrhythmic drugs have important side effects and relatively low efficacy, while catheter ablation, even if it is actually an established treatment, is an invasive procedure with intrinsic procedural risks and is frequently affected by patients' hemodynamic instability. Stereotactic arrhythmia radioablation for ventricular arrhythmias was developed as bail-out therapy in patients unresponsive to traditional treatments. Radiotherapy has been mainly applied in the oncological field, but new current perspectives have developed in the field of ventricular arrhythmias. Stereotactic arrhythmia radioablation provides an alternative non-invasive and painless therapeutic strategy for the treatment of previously detected cardiac arrhythmic substrate by three-dimensional intracardiac mapping or different tools. Since preliminary experiences have been reported, several retrospective studies, registries, and case reports have been published in the literature. Although, for now, stereotactic arrhythmia radioablation is considered an alternative palliative treatment for patients with refractory ventricular tachycardia and no other therapeutic options, this research field is currently extremely promising.

18.
J Pers Med ; 13(4)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37108982

RESUMO

Purpose: Approaching treatment for elderly patients with atrial fibrillation is difficult. A prospective phase II trial evaluating LINAC-based stereotactic arrhythmia radioablation (STAR) safety in this population started in 2021. Dosimetric and planning data were reported. Materials and Methods: A vac-lock bag was used for immobilization in the supine position and a computed tomography (CT, 1 mm) was performed. The clinical target volume (CTV) was defined as the area around the pulmonary veins. An internal target volume (ITV) was added to the CTV to compensate heart and respiratory movement. The planning target volume (PTV) was defined by adding 0-3 mm to the ITV. STAR was performed during free-breathing with a PTV prescription total dose (Dp) of 25 Gy/1 fraction. Flattening filter-free volumetric-modulated arc therapy plans were generated, optimized, and delivered by TrueBeamTM. Image-guided radiotherapy with cone-beam CT and surface-guided radiotherapy with Align-RT (Vision RT) were employed. Results: From May 2021 to March 2022, 10 elderly patients were treated. Mean CTVs, ITVs, and PTVs were 23.6 cc, 44.32 cc, and 62.9 cc, respectively; the mean prescription isodose level and D2% were 76.5% and 31.2 Gy, respectively. The average heart and left anterior descending artery (LAD) Dmean were 3.9 and 6.3 Gy, respectively; the mean Dmax for LAD, spinal cord, left and right bronchus, and esophagus were 11.2, 7.5, 14.3, 12.4, and 13.6 Gy, respectively. The overall treatment time (OTT) was 3 min. Conclusions: The data showed an optimal target coverage, sparing surrounding tissue, in 3 min of OTT. LINAC-based STAR for AF could represent a valid non-invasive alternative for elderly patients who were excluded from catheter ablation.

20.
Eur Heart J ; 32(16): 2042-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21565849

RESUMO

AIMS: To assess whether platelet reactivity is increased in offspring of patients with early acute myocardial infarction (AMI) and its possible relation with endothelial dysfunction. METHODS AND RESULTS: We studied 23 healthy children (15±3 years, 13 males) of patients with early AMI (≤50 years old; Group 1) and 21 healthy children of healthy subjects without any history of cardiovascular disease (14±3 years, 10 males; Group 2). Platelet reactivity was assessed by flow cytometry as the increase in monocyte-platelet aggregates (MPA) and CD41 and PAC-1 platelet expression in response to exercise stress test (EST), adenosine diphosphate (ADP) stimulation (10(-7) M), or both. Endothelial function was assessed by measuring brachial artery dilation during post-ischaemic forearm hyperaemia [flow-mediated dilation (FMD)]. Both EST and ADP induced a higher percentage increase in platelet receptor expression in Group 1, compared with Group 2, with the most significant difference being shown for the response to the combined stimuli (e.g. MPA, 23.1±12 vs. 5.63±8%, P<0.001; platelet PAC-1, 57.7±47 vs. 13.2±7%, P<0.001). Compared with Group 2, Group 1 children showed lower FMD (10.7±3.1 vs. 8.0±2.9%, respectively; P=0.007). However, no significant association was found between FMD and platelet reactivity. CONCLUSION: Our results show increased platelet reactivity in children of patients with early AMI; the finding was not significantly correlated with endothelial dysfunction, suggesting that other mechanisms are mainly involved in the enhanced platelet response to agonistic stimuli.


Assuntos
Endotélio Vascular/fisiologia , Infarto do Miocárdio/sangue , Agregação Plaquetária/fisiologia , Glicoproteína IIb da Membrana de Plaquetas/metabolismo , Difosfato de Adenosina/farmacologia , Adolescente , Adulto , Análise de Variância , Anticorpos Monoclonais Murinos/metabolismo , Criança , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monócitos/fisiologia , Infarto do Miocárdio/genética , Linhagem , Agregação Plaquetária/efeitos dos fármacos , Agregação Plaquetária/genética , Inibidores da Agregação Plaquetária/farmacologia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Molécula 1 de Adesão de Célula Vascular/metabolismo , Vasodilatação/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA