Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 11(4)2022 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-35207183

RESUMO

Sub-optimal sensitivity and specificity in current allograft monitoring methodologies underscore the need for more accurate and reflexive immunosurveillance to uncover the flux in alloimmunity between allograft health and the onset and progression of rejection. QSant-a urine based multi-analyte diagnostic test-was developed to profile renal transplant health and prognosticate injury, risk of evolution, and resolution of acute rejection. Q-Score-the composite score, across measurements of DNA, protein and metabolic biomarkers in the QSant assay-enables this risk prognostication. The domain of immune quiescence-below a Q-Score threshold of 32-is well established, based on published AUC of 98% for QSant. However, the trajectory of rejection is variable, given that causality is multi-factorial. Injury and subtypes of rejection are captured by the progression of Q-Score. This publication explores the clinical utility of QSant across the alloimmunity gradient of 32-100 for the early diagnosis of allograft injury and rejection.

2.
Food Chem ; 275: 446-456, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30724219

RESUMO

Celiac disease, characterized by autoimmune reactions to dietary gluten, affects up to 3 million in the US and approximately 0.5%-1% globally. A strict, lifelong gluten-free diet is the only treatment. An economic, simple, accurate, rapid and portable gluten testing device would enable gluten-sensitive individuals to safeguard their food safety. We developed a novel solution, Nima™, a gluten sensor that integrates food processing, gluten detection, result interpretation and data transmission in a portable device, detecting gluten proteins at or below the accepted 20 ppm threshold. We developed specific monoclonal antibodies, an optimized lateral flow immunoassay strip, and one-step aqueous extraction. Compared with reference R5, NimaTM antibodies (13F6 and 14G11) had 35- and 6.6-fold higher gliadin affinities, respectively. We demonstrated device performance using a comprehensive list of foods, assessing detection sensitivity, reproducibility, and cross-reactivity. Nima™ presented a 99.0% true positive rate, with a 95% confidence interval of 97.8%-100%.


Assuntos
Custos e Análise de Custo , Glutens/análise , Imunoensaio/economia , Imunoensaio/instrumentação , Anticorpos Monoclonais/imunologia , Doença Celíaca/imunologia , Manipulação de Alimentos , Inocuidade dos Alimentos , Glutens/imunologia , Humanos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA