Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Emerg Med ; 51(4): 349-357, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27471132

RESUMO

BACKGROUND: Although the C-MAC (Karl Storz, Tuttlingen, Germany) is a video laryngoscope (VL), it can also be used as a direct laryngoscope (DL). OBJECTIVE: The goal of this study was to evaluate the utility of the C-MAC as a DL for intubations in the emergency department (ED). METHODS: This was an analysis of prospectively collected continuous quality-improvement data during the 6-year period from February 1, 2009 to January 31, 2015, when both the C-MAC and Macintosh DL (Mac DL) were clinically available in our ED. This analysis included adult patients who underwent rapid sequence intubation by an emergency medicine resident in the ED with a C-MAC initially used as a DL or a Mac DL. The primary outcome measure was the first pass success (FPS). RESULTS: When the C-MAC was used as a DL, the initial DL attempt was successful in 199 of 346 (57.6%) cases. When the attempt could not be completed using the C-MAC as a DL, the operator utilized the video monitor and successfully completed the intubation using VL in 104 of 134 (77.6%) cases, thus achieving an overall FPS of 303 of 346 (87.6%). When the Mac DL was used, the FPS was 505 of 671 (75.3%). CONCLUSIONS: The C-MAC is a useful device for DL because in the event of a failed DL attempt, operators have the option of switching to the video monitor to successfully complete the intubation using VL without having to make a second attempt.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Adulto , Idoso , Serviço Hospitalar de Emergência , Feminino , Humanos , Hipóxia/etiologia , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Laringoscopia/efeitos adversos , Laringe/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos
2.
J Emerg Med ; 48(3): 280-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25498851

RESUMO

OBJECTIVE: To compare the effectiveness of the C-MAC® video laryngoscope (CMAC) to the direct laryngoscope (DL) when used to rescue a failed first attempt intubation in the emergency department (ED). METHODS: Data were prospectively collected on all patients intubated in an academic ED center over a five-year period from February 1, 2009 to January 31, 2014 when both the CMAC and the DL were available. Following each intubation the operator completed a continuous quality improvement (CQI) form documenting patient, operator and intubation characteristics. All orotracheal intubations attempted by emergency physicians (EPs) on adult patients with a failed first intubation attempt, and in which the CMAC or the DL was used for the second attempt, were included. The primary outcome was successful intubation on the second attempt using either the CMAC or the DL. A multivariate logistic regression analysis was performed to adjust for potential confounders. RESULTS: During the five-year study period, there were 460 adult orotracheal intubation attempts by EPs which were not successful on the first attempt. In 398 (86.5%) of these cases the same operator performed the second attempt. The CMAC was utilized for the second attempt in 141 cases and was successful in 116 (82.3%; 95% CI 75.0%-88.2%) and the DL was utilized in 94 cases and was successful in 58 (61.7%; 95% CI 51.1%-71.5%). In a multivariate logistic regression analysis the CMAC was associated with an increased odds (adjusted OR 3.5; 95% CI 1.9-6.7) of a second attempt success compared to the DL. CONCLUSIONS: After a failed first intubation attempt in the ED, regardless of the initial device used, the CMAC was more successful than the DL when used for the second attempt. This suggests that the CMAC is the preferred rescue device after an initial intubation attempt in the ED fails.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência , Feminino , Humanos , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Melhoria de Qualidade , Falha de Tratamento , Adulto Jovem
3.
Intern Emerg Med ; 11(7): 983-92, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26846234

RESUMO

Critically ill patients undergoing emergent intubation are at risk of oxygen desaturation during the management of their airway. Patients with intracranial hemorrhage (ICH) are particularly susceptible to the detrimental effects of hypoxemia. Apneic oxygenation (AP OX) may be able to reduce the occurrence of oxygen desaturation during the emergent intubation of these patients. We sought to assess the effect AP OX on oxygen desaturation during the rapid sequence intubation (RSI) of patients with ICH in the emergency department (ED). We prospectively collected data on all patients intubated in an urban academic ED over the 2-year period from July 1, 2013 to June 30, 2015. Following each intubation, the operator completed a standardized continuous quality improvement (CQI) data form, which included information on patient, operator and intubation characteristics. Operators recorded data on the use of AP OX, the oxygen flow rate used for AP OX, and the starting and lowest saturations during intubation. Adult patients with ICH who underwent RSI by emergency medicine (EM) residents were included in the analyses. The primary outcome variable was any oxygen saturation <90 % during the intubation. We performed a backward stepwise multivariate logistic regression analysis to identify variables associated with oxygen desaturation. The primary independent variable of interest was the use of AP OX during the intubation. Inclusion criteria for the study was met by 127 patients. AP OX was used in 72 patients (AP OX group) and was not used in 55 patients (NO AP OX group). The incidence of desaturation was 5/72 (7 %) in the AP OX group and was 16/55 (29 %) in the NO AP OX group. In the multivariate logistic regression analysis the use of AP OX was associated with a reduced odds of desaturation (aOR 0.13; 95 % CI 0.03-0.53). Patients with ICH who received AP OX during RSI in the ED were seven times less likely to have an oxygen saturation of <90 % during the intubation compared to patients who did not receive AP OX. AP OX is a simple intervention that may minimize the risk of oxygen desaturation during the RSI of patients with ICH.


Assuntos
Manuseio das Vias Aéreas/métodos , Hipóxia/prevenção & controle , Hemorragias Intracranianas/tratamento farmacológico , Oxigenoterapia/métodos , Resultado do Tratamento , Adulto , Idoso , Manuseio das Vias Aéreas/normas , Manuseio das Vias Aéreas/tendências , Arizona , Serviço Hospitalar de Emergência/organização & administração , Feminino , Humanos , Hemorragias Intracranianas/mortalidade , Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Intubação Intratraqueal/tendências , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Oxigenoterapia/normas , Oxigenoterapia/tendências
4.
Acad Emerg Med ; 23(6): 703-10, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26836712

RESUMO

OBJECTIVES: The objective was to determine the effect of apneic oxygenation (AP OX) on first pass success without hypoxemia (FPS-H) in adult patients undergoing rapid sequence intubation (RSI) in the emergency department (ED). METHODS: Continuous quality improvement data were prospectively collected on all patients intubated in an academic ED from July 1, 2013, to June 30, 2015. During this period the use of AP OX was introduced and encouraged for all patients undergoing RSI in the ED. Following each intubation, the operator completed a standardized data form that included information on patient, operator, and intubation characteristics. Adult patients 18 years of age or greater who underwent RSI in the ED by emergency medicine residents were included in the analysis. The primary outcome was FPS-H, which was defined as successful tracheal intubation on a single laryngoscope insertion without oxygen saturation falling below 90%. A multivariate logistic regression analysis was performed to determine the effect of AP OX on FPS-H. RESULTS: During the 2-year study period, 635 patients met inclusion criteria. Of these, 380 (59.8%) had AP OX utilized and 255 (40.2%) had no AP OX utilized. In the AP OX cohort the FPS-H was 312/380 (82.1%) and in the no AP OX cohort the FPS-H was 176/255 (69.0%) (difference = 13.1%, 95% confidence interval [CI] = 6.2% to 19.9%). In the multivariate logistic regression analysis, the use of AP OX was associated with an increased odds of FPS-H (adjusted odds ratio = 2.2, 95% CI = 1.5 to 3.3). CONCLUSIONS: The use of AP OX during the RSI of adult patients in the ED was associated with a significant increase in FPS-H. These results suggest that the use of AP OX has the potential to increase the safety of RSI in the ED by reducing the number of intubation attempts and the incidence of hypoxemia.


Assuntos
Competência Clínica , Serviço Hospitalar de Emergência/organização & administração , Internato e Residência/estatística & dados numéricos , Intubação Intratraqueal/métodos , Melhoria de Qualidade/estatística & dados numéricos , Adulto , Idoso , Manuseio das Vias Aéreas/métodos , Medicina de Emergência/educação , Feminino , Humanos , Laringoscópios , Masculino , Pessoa de Meia-Idade , Razão de Chances
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA