Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(8)2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35458809

RESUMO

In this article, we present our research achievements regarding the development of a remote sensing system for motor pulse acquisition, as a first step towards a complete neuroprosthetic arm. We present the fabrication process of an implantable electrode for nerve impulse acquisition, together with an innovative wirelessly controlled system. In our study, these were combined into an implantable device for attachment to peripheral nerves. Mechanical and biocompatibility tests were performed, as well as in vivo testing on pigs using the developed system. This testing and the experimental results are presented in a comprehensive manner, demonstrating that the system is capable of accomplishing the requirements of its designed application. Most significantly, neural electrical signals were acquired and transmitted out of the body during animal experiments, which were conducted according to ethical regulations in the field.


Assuntos
Sistema Nervoso Periférico , Tecnologia de Sensoriamento Remoto , Potenciais de Ação , Animais , Eletrodos Implantados , Nervos Periféricos/fisiologia , Suínos
2.
Biosensors (Basel) ; 14(1)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38248408

RESUMO

There is great interest in the development of prosthetic limbs capable of complex activities that are wirelessly connected to the patient's neural system. Although some progress has been achieved in this area, one of the main problems encountered is the selective acquisition of nerve impulses and the closing of the automation loop through the selective stimulation of the sensitive branches of the patient. Large-scale research and development have achieved so-called "cuff electrodes"; however, they present a big disadvantage: they are not selective. In this article, we present the progress made in the development of an implantable system of plug neural microelectrodes that relate to the biological nerve tissue and can be used for the selective acquisition of neuronal signals and for the stimulation of specific nerve fascicles. The developed plug electrodes are also advantageous due to their small thickness, as they do not trigger nerve inflammation. In addition, the results of the conducted tests on a sous scrofa subject are presented.


Assuntos
Antebraço , Inflamação , Humanos , Eletrodos Implantados , Potenciais de Ação , Automação
3.
Pharmaceuticals (Basel) ; 16(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36678545

RESUMO

Green chemistry is a pharmaceutical industry tool, which, when implemented correctly, can lead to a minimization in resource consumption and waste. An aqueous extract of Salix alba L. was employed for the efficient and rapid synthesis of silver/gold particle nanostructures via an inexpensive, nontoxic and eco-friendly procedure. The nanoparticles were physicochemically characterized using ultraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS), X-ray diffraction (XRD) and scanning electron microscopy (SEM), with the best stability of up to one year in the solution obtained for silver nanoparticles without any chemical additives. A comparison of the antimicrobial effect of silver/gold nanoparticles and their formulations (hydrogels, ointments, aqueous solutions) showed that both metallic nanoparticles have antibacterial and antibiofilm effects, with silver-based hydrogels having particularly high antibiofilm efficiency. The highest antibacterial and antibiofilm efficacies were obtained against Pseudomonas aeruginosa when using silver nanoparticle hydrogels, with antibiofilm efficacies of over 75% registered. The hydrogels incorporating green nanoparticles displayed a 200% increased bacterial efficiency when compared to the controls and their components. All silver nanoparticle formulations were ecologically obtained by "green synthesis" and were shown to have an antimicrobial effect or potential as keratinocyte-acting pharmaceutical substances for ameliorating infectious psoriasis wounds.

4.
Talanta ; 210: 120643, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31987187

RESUMO

Two new biomimetic sensors for the detection of adiponectin (A) and leptin (L) through molecularly imprinted polymers (MIPs) onto gold working electrodes (GWEs) were fabricated. Based on electrochemical impedance spectroscopy (EIS) results and cyclic voltammetry (CV) characteristics recorded in the development stages of the fabricated sensors, the sensors were electrochemically optimized and used in an integrated microfluidic platform to detect adiponectin/leptin via conductance signals and non-imprinted electrodes were used as references. To overcome the limitation of the low response signals after template binding non-conductive polyphenol (PP) and poliscopoletin (PS) were used for templates formation. Under optimized experimental conditions the conductance and resistance signals were obtained in the linear range of 0-50 µg ml-1 for A and 1-32 ng∙ml-1 for L with low limits of detection (0.25 µg ml-1 for A and 0.110 ng ml-1 for L). The dedicated platform exhibited an excellent response with great selectivity and stability. Finally, the proposed biomimetic sensors were successfully applied to enable the determination of A and L in human patient's serum with very high accuracy when compared to enzyme-linked immunosorbent assay ELISA reference methods.


Assuntos
Adiponectina/sangue , Materiais Biocompatíveis/química , Técnicas Biossensoriais , Técnicas Eletroquímicas , Leptina/sangue , Técnicas Biossensoriais/instrumentação , Impedância Elétrica , Técnicas Eletroquímicas/instrumentação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA