Diagn Microbiol Infect Dis ; 90(3): 190-195, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29246776

RESUMO

The Loopamp™MTBC detection kit (TB-LAMP) was designed to replace the sputum smear microscopy for the diagnosis of pulmonary tuberculosis. We evaluated its performance at a peripheral laboratory in Vietnam. The sensitivity of TB-LAMP was 45.5% (28.1%-63.6%), which was equal to 3-sputum smear microscopy but lower than that of Xpert MTB/RIF (87.8% [71.8%-96.6%]). In patients with culture-confirmed TB, sensitivity was 80% (51.9%-95.7%) in smear-positive and 16.7% (3.5%-41.4%) in smear-negative cases. The specificity of TB-LAMP was 95.1% (92.7%-96.9%), which was lower than that of smear microscopy (98.9% [97.5%-99.7%]) and Xpert MTB/RIF (99.3% [98.1%-99.9%]) (P<0.05). The probability of TB detection by TB-LAMP was more influenced by sample quality and viscosity than were smear microscopy, Xpert MTB/RIF, and culture. The present data do not support the use of TB-LAMP as a replacement test for smear microscopy in peripheral laboratories.


Assuntos
Mycobacterium tuberculosis/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Pulmonar/diagnóstico , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Escarro/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/microbiologia , Tuberculose Pulmonar/microbiologia , Vietnã , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA