Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
EuroIntervention ; 11(6): 682-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26499221

RESUMO

AIMS: Transcatheter aortic valve implantation has emerged as an alternative to conventional aortic valve replacement in high-risk patients. Diverse prostheses are currently under investigation. The aim of this study was the clinical, safety and efficacy assessment of Braile Inovare Transcatheter Aortic Prosthesis usage. METHODS AND RESULTS: Ninety high-risk or inoperable patients underwent transcatheter aortic valve implantation. The mean logistic EuroSCORE was 39.3%. All patients presented calcified aortic stenosis. The procedures were performed under fluoroscopic and echocardiographic guidance. Prostheses were implanted through the transapical approach under rapid ventricular pacing. Echocardiographic and angiographic controls were included. Implantation was feasible in 87 cases. There was only one case of operative mortality, and 30-day mortality was 13.3%. The median transvalvular aortic gradient was reduced from 44.8±15.3 to 14.1±8.0 mmHg. Left ventricular function improved in the first seven postoperative days. Paravalvular aortic regurgitation was present in 29.7% of cases, mostly trace. One case presented a major vascular complication, and there were two cases of permanent pacemaker implantation. Two cases of major stroke occurred. CONCLUSIONS: Transcatheter aortic valve replacement using the Braile Inovare prosthesis is able to provide encouraging results with significant functional and structural cardiac improvement. It is mandatory to continue follow-up to measure the benefits of this device as well as to improve selection criteria of patients.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Estimulação Cardíaca Artificial , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
2.
Braz J Anesthesiol ; 63(1): 13-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23438798

RESUMO

BACKGROUND AND OBJECTIVES: Malignant hyperthermia (MH) is a pharmacogenetic disease that causes abnormal hypermetabolic reaction to halogenated anesthetics and/or depolarizing muscle relaxants. In Brazil, there is a hotline telephone service for MH since 1991, available 24 hours a day in São Paulo. This article analyzes the activity of the Brazilian hotline service for MH in 2009. METHODS: Prospective analysis of all phone calls made to the Brazilian hotline service for MH from January to December 2009. RESULTS: Twenty-two phone calls were received: 21 from the South/Southeast region of Brazil and one from the North region. Fifteen calls were requests for general information about MH. Seven were about suspected MH acute episodes, two of which were not considered as MH. In five episodes compatible with MH, all patients received halogenated volatile anesthetics (2, isoflurane; 3, sevoflurane) and one also used succinylcholine; there were four men and one woman, with a mean age of 18 years (2-27). The problems described in the five MH episodes were tachycardia (5), increased expired carbon dioxide (4), hyperthermia (3), acidemia (1), rhabdomyolysis (1), and myoglobinuria (1). One patient received dantrolene. All five patients with MH episodes were follow-up in the intensive care unit and recovered without sequelae. Susceptibility to MH was later confirmed in two patients by in vitro muscle contracture test. CONCLUSIONS: The number of calls per year in the Brazilian hotline service for MH is still low. The characteristics of MH episode were similar to those reported in other countries. The knowledge of MH in Brazil needs to be increased.


Assuntos
Linhas Diretas/estatística & dados numéricos , Hipertermia Maligna/epidemiologia , Adolescente , Adulto , Brasil/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA