Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 53(1): 65-71, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24995405

RESUMO

BACKGROUND: Calprotectin is a 36 kDa calcium and zinc binding protein. An increased level of calprotectin points towards inflammatory bowel disease. However, the biomarker calprotectin shows 14 potential cleavages sites for trypsin. Next to trypsin, also the presence of its inhibitor α1-antitrypsin after a gastrointestinal bleeding may affect calprotectin testing. In this study, effects of trypsin and α1-antitrypsin as potential confounders for faecal calprotectin testing are investigated. METHODS: An in vitro model was created. As calprotectin source, leukocytes were isolated and subsequently lysed (1% Triton X-100) and diluted in faecal matrix. Trypsin digestion was carried out by adding trypsin. Incubation occurred for 24 h or 48 h (37 °C). To study the influence of α1-antitrypsin on trypsin, the same experiment was repeated after adding serum containing α1-antitrypsin. RESULTS: In vitro experiments enabled monitoring of the faecal calprotectin digestion, leading to loss of immunoreactivity. Trypsin activity was a potential confounder in the interpretation of calprotectin, in particular for proximal lesions, where exposure of calprotectin to trypsin is prolonged. Relative calprotectin loss was proportional to the amount of trypsin. Decrease of calprotectin was more pronounced after 48 h of incubation in comparison to 24 h of incubation. Analogue experiments also showed stable calprotectin values after adding α1-antitrypsin. CONCLUSIONS: Transit time, trypsin activity and addition of blood as a source of α1-antitrypsin may be regarded as potential confounders in the interpretation of calprotectin results. Age-related cut-off values depending on the anatomical localisation of the lesions could improve the diagnostic efficiency of calprotectin testing.


Assuntos
Artefatos , Testes de Química Clínica , Fezes/química , Complexo Antígeno L1 Leucocitário/análise , Complexo Antígeno L1 Leucocitário/metabolismo , Proteólise , Sequência de Aminoácidos , Humanos , Complexo Antígeno L1 Leucocitário/química , Dados de Sequência Molecular , Tripsina/metabolismo , alfa 1-Antitripsina/metabolismo
2.
Clin Chem Lab Med ; 53(12): 2003-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25883206

RESUMO

BACKGROUND: Leukocyte cytosolic proteins (e.g., calprotectin) are emerging biomarkers for inflammatory bowel disease. Leukocyte aryl esterase activity has been commonly used for sensitive detection of leukocytes in human body fluids such as urine. Urine test strip results are generally reported in categories. As automated strip readers allow quantitative data to be reported, sensitive quantitative detection of leukocytes in body fluids has become possible. Here, we explored the use of leukocyte esterase as a potential alternative faecal biomarker for inflammatory bowel disease. METHODS: We evaluated leukocyte esterase activity in faecal extracts and compared Cobas u 411 (Roche) quantitative reflectance data with calprotectin concentration for 107 routine samples. Stability of leukocyte esterase for trypsin digestion was carried out by adding trypsin to the extract. Incubation occurred at 37 °C for 24 h or 48 h. RESULTS: Reproducibility of the reflectance signal was good (within-run imprecision: 6.1%; between-run imprecision: 6.2%). Results were linear in the range 103-106 WBC/100 mg faeces. The lower limit of detection was 4 WBC/µL and the lower limit of quantification was 5 WBC/µL. Stability of LE activity in stool and faecal matrix was good. An adequate correlation was obtained between leukocyte esterase activity and the faecal calprotectin concentration: log(y)=4.28+0.29log(x). In vitro experiments monitored the digestion of leukocyte esterase and faecal calprotectin. Leukocyte esterase activity was significantly less affected by trypsin activity than calprotectin immunoreactivity. CONCLUSIONS: Quantitative leukocyte esterase activity of faecal extracts provides information about the leukocyte count in the gut lumen. Leukocyte esterase is a promising and affordable alternative biomarker for monitoring inflammatory bowel disease.


Assuntos
Hidrolases de Éster Carboxílico/análise , Hidrolases de Éster Carboxílico/metabolismo , Fezes/enzimologia , Doenças Inflamatórias Intestinais/diagnóstico , Biomarcadores/análise , Ativação Enzimática , Humanos , Doenças Inflamatórias Intestinais/enzimologia , Doenças Inflamatórias Intestinais/metabolismo , Leucócitos/metabolismo , Tripsina/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA