1.
Ophthalmology ; 131(3): 310-321, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37839561

RESUMO

PURPOSE: To characterize focal biomechanical alterations in subclinical keratoconus (SKC) using motion-tracking (MT) Brillouin microscopy and evaluate the ability of MT Brillouin metrics to differentiate eyes with SKC from normal control eyes. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Thirty eyes from 30 patients were evaluated, including 15 eyes from 15 bilaterally normal patients and 15 eyes with SKC from 15 patients. METHODS: All patients underwent Scheimpflug tomography and MT Brillouin microscopy using a custom-built device. Mean and minimum MT Brillouin values within the anterior plateau region and anterior 150 µm were generated. Scheimpflug metrics evaluated included inferior-superior (IS) value, maximum keratometry (Kmax), thinnest corneal thickness, asymmetry indices, Belin/Ambrosio display total deviation, and Ambrosio relational thickness. Receiver operating characteristic (ROC) curves were generated for all Scheimpflug and MT Brillouin metrics evaluated to determine the area under the ROC curve (AUC), sensitivity, and specificity for each variable. MAIN OUTCOME MEASURES: Discriminative performance based on AUC, sensitivity, and specificity. RESULTS: No significant differences were found between groups for age, sex, manifest refraction spherical equivalent, corrected distance visual acuity, Kmax, or KISA% index. Among Scheimpflug metrics, significant differences were found between groups for thinnest corneal thickness (556 µm vs. 522 µm; P < 0.001), IS value (0.29 diopter [D] vs. 1.05 D; P < 0.001), index of vertical asymmetry (IVA; 0.10 vs. 0.19; P < 0.001), and keratoconus index (1.01 vs. 1.05; P < 0.001), and no significant differences were found for any other Scheimpflug metric. Among MT Brillouin metrics, clear differences were found between control eyes and eyes with SKC for mean plateau (5.71 GHz vs. 5.68 GHz; P < 0.0001), minimum plateau (5.69 GHz vs. 5.65 GHz; P < 0.0001), mean anterior 150 µm (5.72 GHz vs. 5.68 GHz; P < 0.0001), and minimum anterior 150 µm (5.70 GHz vs. 5.66 GHz; P < 0.001). All MT Brillouin plateau and anterior 150 µm mean and minimum metrics fully differentiated groups (AUC, 1.0 for each), whereas the best performing Scheimpflug metrics were keratoconus index (AUC, 0.91), IS value (AUC, 0.89), and IVA (AUC, 0.88). CONCLUSIONS: Motion-tracking Brillouin microscopy metrics effectively characterize focal corneal biomechanical alterations in eyes with SKC and clearly differentiated these eyes from control eyes, including eyes that were not differentiated accurately using Scheimpflug metrics. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Microscopia , Estudos Transversais , Estudos Prospectivos , Paquimetria Corneana
2.
Exp Eye Res ; 205: 108508, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33609511

RESUMO

The characterization of corneal biomechanical properties has important implications for the management of ocular disease and prediction of surgical responses. Corneal refractive surgery outcomes, progression or stabilization of ectatic disease, and intraocular pressure determination are just examples of the many key clinical problems that depend highly upon corneal biomechanical characteristics. However, to date there is no gold standard measurement technique. Since the advent of a 1-dimensional (1D) air-puff based technique for measuring the corneal surface response in 2005, advances in clinical imaging technology have yielded increasingly sophisticated approaches to characterizing the biomechanical properties of the cornea. Novel analyses of 1D responses are expanding the clinical utility of commercially-available air-puff-based instruments, and other imaging modalities-including optical coherence elastography (OCE), Brillouin microscopy and phase-decorrelation ocular coherence tomography (PhD-OCT)-offer new opportunities for probing local biomechanical behavior in 3-dimensional space and drawing new inferences about the relationships between corneal structure, mechanical behavior, and corneal refractive function. These advances are likely to drive greater clinical adoption of in vivo biomechanical analysis and to support more personalized medical and surgical decision-making.


Assuntos
Fenômenos Biomecânicos/fisiologia , Córnea/fisiologia , Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Humanos , Imageamento Tridimensional/métodos , Microscopia/métodos , Tomografia de Coerência Óptica/métodos
3.
Ophthalmology ; 131(5): e23-e24, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38219143
4.
Ophthalmology ; 125(7): 1014-1027, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29409662

RESUMO

PURPOSE: To report the 3-year assessment of feasibility and usefulness of microscope-integrated intraoperative OCT (iOCT) during ophthalmic surgery. DESIGN: Prospective, consecutive case series. PARTICIPANTS: Adult participants undergoing incisional ophthalmic surgery with iOCT imaging who consented to be enrolled in the Determination of Feasibility of Intraoperative Spectral-Domain Microscope Combined/Integrated OCT Visualization during En Face Retinal and Ophthalmic Surgery (DISCOVER) study. METHODS: The DISCOVER study is a single-site, multisurgeon, institutional review board-approved investigational device prospective study. Participants included patients undergoing anterior or posterior segment surgery who underwent iOCT imaging with 1 of 3 prototype microscope-integrated iOCT systems (i.e., Zeiss Rescan 700, Leica EnFocus, or Cole Eye iOCT systems). Clinical characteristics were documented, iOCT was directed by the operating surgeon at predetermined surgical time points, and each surgeon completed a questionnaire after surgery to evaluate the usefulness of iOCT during surgery. MAIN OUTCOME MEASURES: Feasibility of iOCT based ability to obtain an OCT image during surgery and usefulness of iOCT based on surgeon reporting during surgery. RESULTS: Eight hundred thirty-seven eyes (244 anterior segment cases and 593 posterior segment cases) were enrolled in the DISCOVER study. Intraoperative OCT demonstrated feasibility with successful image acquisition in 820 eyes (98.0%; 95% confidence interval [CI], 96.8%-98.8%). In 106 anterior segment cases (43.4%; 95% CI, 37.1%-49.9%), the surgeons indicated that the iOCT information impacted their surgical decision making and altered the procedure. In posterior segment procedures, surgeons reported that iOCT enabled altered surgical decision making during the procedure in 173 cases (29.2%; 95% CI, 25.5%-33.0%). CONCLUSIONS: The DISCOVER iOCT study demonstrated both generalized feasibility and usefulness based on the surgeon-reported impact on surgical decision making. This large-scale study confirmed similar findings from other studies on the potential value and impact of iOCT on ophthalmic surgery.


Assuntos
Oftalmopatias/diagnóstico por imagem , Oftalmopatias/cirurgia , Microscopia/instrumentação , Monitorização Intraoperatória/métodos , Procedimentos Cirúrgicos Oftalmológicos , Cirurgia Assistida por Computador , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Ergonomia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Avaliação da Tecnologia Biomédica , Resultado do Tratamento , Adulto Jovem
5.
Ophthalmology ; 121(2): 459-68, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24289916

RESUMO

PURPOSE: To evaluate the performance of corneal hysteresis (CH), corneal resistance factor, and 16 investigator-derived Ocular Response Analyzer (ORA) variables in distinguishing keratoconus (KC) from the nondiseased state. DESIGN: Retrospective case series. PARTICIPANTS: Fifty-four eyes of 27 unaffected patients and 49 eyes of 25 KC patients from the Instituto de Olhos, Rio de Janeiro, Brazil. METHODS: Sixteen candidate variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior. Area under the receiver operating characteristic curve (AUC) and the Z statistic were used to compare diagnostic performance. MAIN OUTCOME MEASURES: Discriminant value of standard and derived ORA variables as measured by AUC. RESULTS: Fifteen of 16 candidate variables performed significantly better than chance (AUC, >0.5) at discriminating KC. Diagnostic performance was greatest for a custom variable related to the depth of deformation as defined by the minimum applanation signal intensity during corneal deformation (concavity(min); mean AUC ± standard error, 0.985 ± 0.002) and a new measure incorporating the pressure-deformation relationship of the entire response cycle (hysteresis loop area, 0.967 ± 0.002). Z statistics assessing the discriminative value of each of the top 5 variables demonstrated superiority to CH (AUC, 0.862 ± 0.002). Concavity(min) had the best overall predictive accuracy (cutoff value, 50.37; 94.9% sensitivity, 91.7% specificity, and 93.2% test accuracy), and the top 4 variables demonstrated the most consistent relationships to KC severity. CONCLUSIONS: Investigator-derived ORA variables related to the depth of deformation and the pressure-deformation relationship demonstrated very high test accuracy for detecting the presence of KC. Beyond their diagnostic value, the candidate variables described in this report provide mechanistic insight into the nature of the ORA signal and the characteristic changes in corneal dynamics associated with KC.


Assuntos
Córnea/fisiopatologia , Técnicas de Imagem por Elasticidade , Elasticidade/fisiologia , Ceratocone/diagnóstico , Adulto , Topografia da Córnea , Análise Discriminante , Feminino , Humanos , Pressão Intraocular , Ceratocone/fisiopatologia , Masculino , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Exp Eye Res ; 125: 114-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24929203

RESUMO

Studies suggest that standard corneal collagen crosslinking (CXL) is a safe and effective treatment to stiffen the cornea for keratoconus and other ectatic corneal disorders. The purpose of the present study was to compare the biomechanical effects of transepithelial benzalkonium chloride-EDTA (BAC-EDTA) riboflavin-UVA crosslinking to standard epithelium-off riboflavin-UVA crosslinking in a rabbit model. Corneal stiffness was quantified using optical coherence elastography at two months after treatment. The mean lateral-to-axial displacement ratio for the BAC-EDTA transepithelial CXL group was lower (greater stiffness) [0.062 ± 0.042, mean ± SD] than epithelium-off CXL (mean ± SD: 0.065 ± 0.045) or untreated control eyes (0.069 ± 0.044). Using ANOVA with Tukey correction, a statistically significant difference was found between the BAC-EDTA transepithelial CXL group and standard epithelium-off CXL (p = 0.0019) or the untreated control (p < 0.0001) groups. A graph of the probability density functions for biomechanical stiffness also showed a greater shift in stiffening in the BAC-EDTA transepithelial CXL group than the standard epithelium-off CXL or untreated control group. These results demonstrated that the biomechanical stiffening effect produced by BAC-EDTA transepithelial CXL was greater than that produced by standard epithelium-off CXL in a rabbit model.


Assuntos
Córnea/efeitos dos fármacos , Reagentes de Ligações Cruzadas/farmacologia , Elasticidade/efeitos dos fármacos , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Análise de Variância , Animais , Compostos de Benzalcônio/farmacologia , Fenômenos Biomecânicos/fisiologia , Quelantes/farmacologia , Córnea/fisiopatologia , Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade , Modelos Animais , Coelhos , Raios Ultravioleta
7.
Eye Contact Lens ; 40(6): 339-44, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25365551

RESUMO

PURPOSE: To assess changes in Ocular Response Analyzer (ORA) waveforms after UVA/riboflavin corneal collagen cross-linking (CXL) using investigator-derived and manufacturer-supplied morphometric variables in patients with keratoconus (KC) and postrefractive surgery ectasia. DESIGN: Prospective randomized trial of a standard epithelium-off CXL protocol. PARTICIPANTS: Patients with progressive KC (24 eyes of 21 patients) or postrefractive surgery ectasia (27 eyes of 23 patients) were enrolled. METHODS: Replicate ORA measurements were obtained before and 3 months after CXL. Pretreatment and posttreatment waveform variables were analyzed for differences by paired Student t tests using measurements with the highest waveform scores. MAIN OUTCOME MEASURES: Corneal hysteresis, corneal resistance factor, 37-s generation manufacturer-supplied ORA variables, and 15 investigator-derived ORA variables. RESULTS: No variables were significantly different 3 months after CXL in the KC group, and no manufacturer-supplied variables changed significantly in the postrefractive surgery ectasia group. Four custom variables (ApplanationOnsetTime, P1P2avg, Impulse, and Pmax) increased by small but statistically significant margins after CXL in the postrefractive surgery ectasia group. CONCLUSIONS: Changes in a small subset of investigator-derived variables suggested an increase in corneal bending resistance after CXL. However, the magnitudes of these changes were low and not commensurate with the degree of clinical improvement or prior computational estimates of corneal stiffening in the same cohort over the same period. Available air-puff-derived measures of the corneal deformation response underestimate the biomechanical changes produced by CXL.


Assuntos
Fenômenos Biomecânicos/fisiologia , Doenças da Córnea/tratamento farmacológico , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fotoquimioterapia , Adulto , Colágeno/efeitos dos fármacos , Córnea/efeitos dos fármacos , Doenças da Córnea/etiologia , Doenças da Córnea/fisiopatologia , Topografia da Córnea , Dilatação Patológica/tratamento farmacológico , Dilatação Patológica/fisiopatologia , Feminino , Humanos , Pressão Intraocular/fisiologia , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual/fisiologia
8.
J Refract Surg ; 40(5): e279-e290, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717084

RESUMO

PURPOSE: To review the atypical development of Salzmann's nodular degeneration (SND) after two cases of laser in situ keratomileusis (LASIK) and one case of photorefractive keratomileusis (PRK), and to highlight the pathophysiology of SND and its treatment. METHODS: Three cases of SND (two following LASIK performed with microkeratomes and one following PRK) were reviewed and Pubmed.gov and internet searches were performed. RESULTS: SND is myofibroblast-generated fibrosis in the subepithelial space between the epithelium and Bowman's layer that develops years or decades after traumatic, surgical, infectious, or inflammatory injuries to the cornea in which the epithelial basement membrane is damaged in one or more locations and does not fully regenerate. It is hypothesized based on these cases, and the previous immunohistochemistry of other investigators, that myofibroblast precursors, such as fibrocytes or corneal fibroblasts, that enter the subepithelial space are driven to develop into myofibroblasts, which slowly proliferate and extend the fibrosis, by transforming growth factor-beta from epithelium and tears that passes through the defective epithelial basement membrane. These myofibroblasts and the disordered collagens, and other extracellular matrix components they produce, make up the subepithelial opacity characteristic of SND. Nodules are larger accumulations of myofibroblasts and disordered extracellular matrix. If the injury is associated with damage to the underlying Bowman's layer and stroma, as in LASIK flap generation, then the myofibroblasts and fibrosis can extend into Bowman's layer and the underlying anterior stroma. CONCLUSIONS: SND fibrosis often extends into Bowman's layer and the anterior stroma if there are associated Bowman's defects, such as incisions or lacerations. In the latter cases, SND frequently cannot be removed by simple scrape and peel, as typically performed for most common SND cases, but can be trimmed to remove the offending tissue. This condition is more accurately termed Salzmann's subepithelial fibrosis. [J Refract Surg. 2024;40(5):e279-e290.].


Assuntos
Epitélio Corneano , Fibrose , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Humanos , Epitélio Corneano/patologia , Masculino , Lâmina Limitante Anterior/patologia , Adulto , Miopia/cirurgia , Miopia/fisiopatologia , Feminino , Doenças da Córnea/etiologia , Doenças da Córnea/cirurgia , Lasers de Excimer/uso terapêutico , Miofibroblastos/patologia , Pessoa de Meia-Idade
9.
Exp Eye Res ; 113: 92-104, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23664859

RESUMO

Corneal collagen crosslinking with riboflavin photosensitization and ultraviolet irradiation is a novel approach to limiting the progression of keratoconus in patients by increasing the elastic modulus of the degenerate cornea. Beneficial reductions in corneal steepness and aberrations after crosslinking also frequently occur. In a previous study, we described a computational modeling approach to simulating topographic progression in keratoconus and regression of disease with corneal collagen crosslinking. In the current study, this model has been expanded and applied to the inverse problem of estimating longitudinal time-dependent changes in the corneal elastic modulus after crosslinking using in vivo measurements from 16 human eyes. Topography measured before crosslinking was used to construct a patient-specific finite element model with assumed hyperelastic properties. Then the properties of the cornea were altered using an inverse optimization method to minimize the difference between the model-predicted and in vivo corneal shape after crosslinking. Effects of assumptions regarding sclera-to-cornea elastic modulus ratio and spatial attenuation of treatment effect due to ultraviolet beam characteristics on the predicted change in elastic modulus were also investigated. Corneal property changes computed by inverse finite element analysis provided excellent geometric agreement with clinical topography measurements in patient eyes post-crosslinking. Over all post-treatment time points, the estimated increase in corneal elastic modulus was 110.8 ± 48.1%, and slightly less stiffening was required to produce the same amount of corneal topographic regression of disease when the sclera-to-cornea modulus ratio was increased. Including the effect of beam attenuation resulted in greater estimates of stiffening in the anterior cornea. Corneal shape responses to crosslinking varied considerably and emphasize the importance of a patient-specific approach.


Assuntos
Colágeno/metabolismo , Substância Própria/fisiologia , Reagentes de Ligações Cruzadas/uso terapêutico , Elasticidade/fisiologia , Ceratocone/tratamento farmacológico , Simulação por Computador , Substância Própria/efeitos da radiação , Topografia da Córnea , Módulo de Elasticidade , Feminino , Análise de Elementos Finitos , Humanos , Ceratocone/metabolismo , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta
10.
J Refract Surg ; 29(5): 332-41, 2013 05.
Artigo em Inglês | MEDLINE | ID: mdl-23659231

RESUMO

PURPOSE: To compare the biological effects of riboflavin-ultraviolet A (UVA) corneal cross-linking (CXL) performed with a traditional epithelium-off method to several transepithelial methods in a rabbit model. Preliminary experiments on biomechanical rigidity were also performed. METHODS: Four treatment groups were included: (1) standard epithelium-off, (2) tetracaine transepithelial, (3) benzal-konium chloride-ethylenediaminetetraacetic acid (BKC-EDTA) transepithelial, and (4) femtosecond laser-assisted transepithelial riboflavin-UVA CXL. Six eyes from each treatment group and the untreated control group were analyzed at 24 hours and 2 months after treatment in wound healing studies. The TUNEL assay was performed to detect the extent of stromal cell death. Optical density was measured with a Scheimpflug analyzer. The corneal stiffening effect was quantitated in three eyes from each group using optical coherence elastography performed 2 months after treatments. RESULTS: Twenty-four hours after CXL, stromal cell death extended full corneal thickness with both standard epithelium-off CXL and femtosecond laser-assisted CXL, but only approximately one-third stromal depth after BKC-EDTA transepithelial CXL. Negligible stromal cell death was detected with tetracaine transepithelial CXL. Cell death results were statistically different between the BKC-EDTA transepithelial CXL and standard epithelium-off CXL groups (P < .0001). Significant corneal opacity differences were noted. Standard epithelium-off CXL had the greatest density and tetracaine transepithelial CXL had the least density compared to the control group after treatment. As measured with optical coherence elastography, a trend toward greater mean stiffening was observed with BKC-EDTA transepithelial CXL than with epithelium-off CXL, femtosecond laser-assisted CXL, or tetracaine transepithelial CXL, but the result did not reach statistical significance. All of the CXL treatment groups exhibited significantly smaller variance of stiffness compared to the control group. CONCLUSION: In the rabbit model, BKC-EDTA transepithelial CXL produced less stromal cell death and less risk of endothelial cell damage than standard epithelium-off CXL or femtosecond laser-assisted CXL. Additional study is needed to determine whether biomechanical stiffness is significantly different between the epithelium-off CXL and transepithelial CXL groups.


Assuntos
Córnea/efeitos dos fármacos , Córnea/fisiopatologia , Reagentes de Ligações Cruzadas/farmacologia , Elasticidade/fisiologia , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Animais , Compostos de Benzalcônio/farmacologia , Fenômenos Biomecânicos/fisiologia , Morte Celular , Substância Própria/patologia , Técnicas de Imagem por Elasticidade , Endotélio Corneano/patologia , Epitélio Corneano/efeitos dos fármacos , Marcação In Situ das Extremidades Cortadas , Lasers de Excimer/uso terapêutico , Coelhos , Tetracaína/farmacologia , Tomografia de Coerência Óptica , Raios Ultravioleta
11.
Am J Ophthalmol ; 254: 128-140, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36963605

RESUMO

PURPOSE: To characterize focal biomechanical differences between normal, keratoconic, and post-laser vision correction (LVC) corneas using motion-tracking Brillouin microscopy. DESIGN: Prospective cross-sectional study. METHODS: Thirty eyes from 30 patients (10 normal controls [Controls], 10 post-LVC, and 10 stage I or II keratoconus [KC]) had Scheimpflug and motion-tracking Brillouin microscopy imaging using a custom-built device. Mean, maximum (max) and minimum (min) Brillouin shift, spatial standard deviation, and max-min values were compared. Min values were correlated with local Brillouin values at multiple Scheimpflug imaging locations. RESULTS: Mean (P < .0003), min (P < .00001), spatial standard deviation (P < .01), and max-min (P < .001) were significantly different between the groups. In post hoc pairwise comparisons, the best differentiators for group comparisons were mean (P = .0004) and min (P = .000002) for Controls vs KC, min (P = .0022) and max-min (P = .002) for Controls vs LVC, and mean (P = .0037) and min (P = .0043) for LVC vs KC. Min (area under the receiver operating characteristic = 1.0) and mean (area under the receiver operating characteristic =  0.96) performed well in differentiating Control and KC eyes. Min values correlated best with Brillouin shift values at the thinnest corneal point (r2 = 0.871, P = .001) and maximum keratometry value identified in the tangential curvature map (r2 = 0.840, P = .002). CONCLUSIONS: Motion-tracking Brillouin microscopy effectively characterized focal corneal biomechanical alterations in LVC and KC and clearly differentiated these groups from Controls. Primary motion-tracking Brillouin metrics performed well in differentiating groups as compared with basic Scheimpflug metrics, in contrast to previous Brillouin studies, and identified focal changes after LVC where prior Brillouin studies did not.


Assuntos
Ceratocone , Microscopia , Humanos , Estudos Transversais , Estudos Prospectivos , Topografia da Córnea/métodos , Córnea , Ceratocone/diagnóstico , Ceratocone/cirurgia , Curva ROC , Lasers , Paquimetria Corneana
12.
Transl Vis Sci Technol ; 12(3): 25, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36971678

RESUMO

Purpose: The purpose of this work is to determine the sensitivity of phase-decorrelation optical coherence tomography (OCT) to protein aggregation associated with cataracts in the ocular lens, as compared to OCT signal intensity. Methods: Six fresh porcine globes were held at 4°C until cold cataracts developed. As the globes were re-warmed to ambient temperature, reversing the cold cataract, each lens was imaged repeatedly using a conventional OCT system. Throughout each experiment, the internal temperature of the globe was recorded using a needle-mounted thermocouple. OCT scans were acquired, their temporal fluctuations were analyzed, and the rates of decorrelation were spatially mapped. Both decorrelation and intensity were evaluated as a function of recorded temperature. Results: Both signal decorrelation and intensity were found to change with lens temperature, a surrogate of protein aggregation. However, the relationship between signal intensity and temperature was not consistent across different samples. In contrast, the relationship between decorrelation and temperature was found to be consistent across samples. Conclusions: In this study, signal decorrelation was shown to be a more repeatable metric for quantification of crystallin protein aggregation in the ocular lens than OCT intensity-based metrics. Thus, OCT signal decorrelation measurements could enable more detailed and sensitive study of methods to prevent cataract formation. Translational Relevance: This dynamic light scattering-based approach to early cataract assessment can be implemented on existing clinical OCT systems without hardware additions, so it could quickly become part of a clinical study workflow or an indication for use for a pharmaceutical cataract intervention.


Assuntos
Catarata , Cristalino , Animais , Suínos , Tomografia de Coerência Óptica/métodos , Agregados Proteicos , Catarata/diagnóstico , Cristalino/diagnóstico por imagem
13.
Am J Ophthalmol ; 251: 126-142, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36549584

RESUMO

PURPOSE: To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection. DESIGN: Multicenter cross-sectional case-control retrospective study. METHODS: A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations. The database included 1 eye randomly selected from 1680 normal patients (N) and from 1181 "bilateral" keratoconus (KC) patients, along with 551 normal topography eyes from patients with very asymmetric ectasia (VAE-NT), and their 474 unoperated ectatic (VAE-E) eyes. The current TBIv1 (tomographic-biomechanical index) was tested, and an optimized AI algorithm was developed for augmenting accuracy. RESULTS: The area under the receiver operating characteristic curve (AUC) of the TBIv1 for discriminating clinical ectasia (KC and VAE-E) was 0.999 (98.5% sensitivity; 98.6% specificity [cutoff: 0.5]), and for VAE-NT, 0.899 (76% sensitivity; 89.1% specificity [cutoff: 0.29]). A novel random forest algorithm (TBIv2), developed with 18 features in 156 trees using 10-fold cross-validation, had a significantly higher AUC (0.945; DeLong, P < .0001) for detecting VAE-NT (84.4% sensitivity and 90.1% specificity; cutoff: 0.43; DeLong, P < .0001) and a similar AUC for clinical ectasia (0.999; DeLong, P = .818; 98.7% sensitivity; 99.2% specificity [cutoff: 0.8]). Considering all cases, the TBIv2 had a higher AUC (0.985) than TBIv1 (0.974; DeLong, P < .0001). CONCLUSIONS: AI optimization to integrate Scheimpflug-based corneal tomography and biomechanical assessments augments accuracy for ectasia detection, characterizing ectasia susceptibility in the diverse VAE-NT group. Some patients with VAE may have true unilateral ectasia. Machine learning considering additional data, including epithelial thickness or other parameters from multimodal refractive imaging, will continuously enhance accuracy. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.


Assuntos
Ceratocone , Humanos , Estudos Retrospectivos , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Inteligência Artificial , Dilatação Patológica/diagnóstico , Paquimetria Corneana/métodos , Estudos Transversais , Córnea/diagnóstico por imagem , Curva ROC , Tomografia/métodos
14.
Cornea ; 41(10): 1205-1206, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35439770

RESUMO

ABSTRACT: The question of whether the epithelium should be removed in corneal cross-linking (CXL) in the treatment of keratoconus and other corneal ectatic disorders remains controversial. The motivation for epithelium-on CXL methods, which are not yet FDA approved and vary greatly in methodology, is to reduce the risk of vision-threatening complications related to debridement. However, as discussed in this counterpoint piece, most high-level evidence suggests that removal of the epithelium facilitates greater crosslinking effectiveness as measured by primary clinical outcome metrics such as topographic flattening and stabilization of disease. Furthermore, quality evidence is still lacking for a significant reduction in rates of infectious keratitis or loss of vision that can be attributed to debridement-related complications. In the absence of comparative effectiveness trials or long-term follow-up studies that show otherwise, the FDA-approved epi-off protocol is still the standard-bearer for safe and effective stabilization of corneal ectatic disease.


Assuntos
Epitélio Corneano , Ceratocone , Fotoquimioterapia , Colágeno/uso terapêutico , Paquimetria Corneana , Reagentes de Ligações Cruzadas/uso terapêutico , Humanos , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Raios Ultravioleta
15.
Am J Ophthalmol ; 240: 125-134, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35247335

RESUMO

PURPOSE: To determine the impact of corneal epithelial thickness maps on screening for refractive surgery candidacy in a single refractive surgical practice. DESIGN: Comparison of screening methods. METHODS: A total of 100 consecutive patients who presented for refractive surgery screening were evaluated. For each patient, screening based on Scheimpflug tomography, clinical data, and patient history was performed and a decision on eligibility for laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and small incision lenticule extraction (SMILE)was independently made by 2 masked examiners. Examiners were then shown patients' epithelial thickness maps derived from optical coherence tomography (OCT). The percentage of screenings that changed after evaluating the epithelial thickness maps, with regard to candidacy for surgery, and ranking of surgical procedures from most to least favorable was determined. RESULTS: Candidacy for corneal refractive surgery changed in 16% of patients after evaluation of the epithelial thickness maps, with 10% of patients screened in and 6% screened out. Surgery of choice changed for 16% of patients, and the ranking of surgical procedures from most to least favorable changed for 25% of patients. A total of 11% of patients gained eligibility for LASIK, whereas 8% lost eligibility for LASIK. No significant difference was found between the evaluations of the 2 examiners. CONCLUSIONS: Epithelial thickness mapping derived from optical coherence tomography imaging of the cornea altered candidacy for corneal refractive surgery, as well as choice of surgery, in a substantial percentage of patients in our practice, and was thus a valuable tool for screening evaluations. Overall, the use of epithelial thickness maps resulted in screening in a slightly larger percentage of patients for corneal refractive surgery.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Córnea/cirurgia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/diagnóstico , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual
17.
J Refract Surg ; 27(10): 753-8, 2011 10.
Artigo em Inglês | MEDLINE | ID: mdl-21800785

RESUMO

PURPOSE: To describe pachymetric progression indices (PPI) of the Pentacam HR (Oculus Optikgeräte GmbH) and the concept of relational thickness, and to test their accuracy for differentiating keratoconic and normal corneas compared with single-point thickness values. METHODS: One hundred thirteen individual eyes randomly selected from 113 normal patients and 44 eyes of 44 patients with keratoconus were studied using the Pentacam HR by acquiring central corneal thickness (CCT), thinnest point (TP), position of the TP and PPI at minimal (PPI Min) and maximal (PPI Max) meridians, and the average (PPI Ave) of all meridians. Relational thickness parameters were calculated as the ratios of TP and CCT and PPI values. Mann-Whitney U test assessed differences in groups for each variable. Receiver operating characteristic (ROC) curves were calculated for all variables and pairwise comparisons were performed. RESULTS: Statistically significant differences were noted between normal and keratoconic eyes for all parameters (P<.001), except for horizontal position of TP (P=.79). The best parameters, named Ambrósio's Relational Thickness (ART), were ART-Ave (TP/PPI Ave) and ART-Max (TP/PPI Max) with areas under the ROC curves of 0.987 and 0.983, respectively. The best cutoffs were 424 µm and 339 µm for ART-Ave and ART-Max, respectively. Pachymetric progression indices and ART had a greater area under the curve than TP and CCT (P<.001); TP (0.955) had a greater area under the curve than CCT (0.909; P=.002). CONCLUSIONS: Tomographic-derived pachymetric parameters were better able to differentiate normal and keratoconic corneas than single-point pachymetric measurements. Further studies are needed to evaluate the role of tomography in identifying early forms of ectasia as well as ectasia risk among LASIK candidates.


Assuntos
Córnea/patologia , Ceratocone/diagnóstico , Adolescente , Adulto , Idoso , Criança , Topografia da Córnea/instrumentação , Progressão da Doença , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fotografação/instrumentação , Curva ROC , Estudos Retrospectivos , Tomografia , Adulto Jovem
18.
J Biomech Eng ; 133(1): 011002, 2011 01.
Artigo em Inglês | MEDLINE | ID: mdl-21186892

RESUMO

The purpose of this study is to develop a 3D patient-specific finite element model (FEM) of the cornea and sclera to compare predicted and in vivo refractive outcomes and to estimate the corneal elastic property changes associated with each procedure. Both eyes of a patient who underwent laser-assisted in situ keratomileusis (LASIK) for myopic astigmatism were modeled. Pre- and postoperative Scheimpflug anterior and posterior corneal elevation maps were imported into a 3D corneo-scleral FEM with an unrestrained limbus. Preoperative corneal hyperelastic properties were chosen to account for meridional anisotropy. Inverse FEM was used to determine the undeformed corneal state that produced <0.1% error in anterior elevation between simulated and in vivo preoperative geometries. Case-specific 3D aspheric ablation profiles were simulated, and corneal topography and spherical aberration were compared at clinical intraocular pressure. The magnitude of elastic weakening of the residual corneal bed required to maximize the agreement with clinical axial power was calculated and compared with the changes in ocular response analyzer (ORA) measurements. The models produced curvature maps and spherical aberrations equivalent to in vivo measurements. For the preoperative property values used in this study, predicted elastic weakening with LASIK was as high as 55% for a radially uniform model of residual corneal weakening and 65% at the point of maximum ablation in a spatially varying model of weakening. Reductions in ORA variables were also observed. A patient-specific FEM of corneal refractive surgery is presented, which allows the estimation of surgically induced changes in corneal elastic properties. Significant elastic weakening after LASIK was required to replicate clinical topographic outcomes in this two-eye pilot study.


Assuntos
Simulação por Computador , Córnea/fisiologia , Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Adulto , Astigmatismo/cirurgia , Fenômenos Biomecânicos , Engenharia Biomédica , Córnea/anatomia & histologia , Topografia da Córnea/estatística & dados numéricos , Elasticidade , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Miopia/cirurgia , Resultado do Tratamento
19.
Transl Vis Sci Technol ; 10(5): 8, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-34328498

RESUMO

Crosslinking involves the formation of bonds between polymer chains, such as proteins. In biological tissues, these bonds tend to stiffen the tissue, making it more resistant to mechanical degradation and deformation. In ophthalmology, the crosslinking phenomenon is being increasingly harnessed and explored as a treatment strategy for treating corneal ectasias, keratitis, degenerative myopia, and glaucoma. This review surveys the multitude of exogenous crosslinking strategies reported in the literature, both "light" (involving light energy) and "dark" (involving non-photic chemical processes), and explores their mechanisms, cytotoxicity, and stage of translational development. The spectrum of ophthalmic applications described in the literature is then discussed, with particular attention to proposed therapeutic mechanisms in the cornea and sclera. The mechanical effects of crosslinking are then discussed in the context of their proposed site and scale of action. Biomechanical characterization of the crosslinking effect is needed to more thoroughly address knowledge gaps in this area, and a review of reported methods for biomechanical characterization is presented with an attempt to assess the sensitivity of each method to crosslinking-mediated changes using data from the experimental and clinical literature. Biomechanical measurement methods differ in spatial resolution, mechanical sensitivity, suitability for detecting crosslinking subtypes, and translational readiness and are central to the effort to understand the mechanistic link between crosslinking methods and clinical outcomes of candidate therapies. Data on differences in the biomechanical effect of different crosslinking protocols and their correspondence to clinical outcomes are reviewed, and strategies for leveraging measurement advances predicting clinical outcomes of crosslinking procedures are discussed. Advancing the understanding of ophthalmic crosslinking, its biomechanical underpinnings, and its applications supports the development of next-generation crosslinking procedures that optimize therapeutic effect while reducing complications.


Assuntos
Córnea , Ceratite , Fenômenos Biomecânicos , Reagentes de Ligações Cruzadas , Humanos , Esclera
20.
J Cataract Refract Surg ; 47(7): 916-926, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33298778

RESUMO

PURPOSE: To compare the results of intrastromal corneal ring segment (ICRS) alone or combined with same-day corneal crosslinking (CXL) and investigate the relationship of preoperative corneal biomechanics data on the outcomes. SETTING: Department of Ophthalmology of Federal University of Parana. DESIGN: Prospective nonrandomized interventional comparative study. METHODS: Forty-nine eyes of 44 keratoconus patients underwent ICRS only (n = 27, Group 1) or same day ICRS+CXL (n = 22, Group 2) and were followed up for at least 24 months. Visual acuity and preoperative and postoperative tomographic variables were compared between groups. Tomographic data were obtained with a dual Scheimpflug analyzer, and eye-specific finite-element models were used to derive 3 variables related to preoperative biomechanical strain (maximum principal strain [MPS]): mean MPS (mMPS), highest local MPS (hMPS), and position of the hMPS (hMPSx and hMPSy). The relationship between preoperative strain data and the change (∆, difference between postoperative and preoperative data) in tomographic parameters was also investigated. RESULTS: Steepest (K2) and maximum keratometry (Kmax), inferior-superior (I-S) index, coma, and cone location magnitude index (CLMI) significantly improved in both groups. Corrected distance visual acuity was significantly better after ICRS alone (P = .03), whereas corneal asymmetry measured through the I-S index was better after CXL+ICRS (P = .04). In Group 1, hMPSy significantly correlated with K2, tomographical cylinder, mean keratometry, and ∆spherical aberration, whereas mMPS significantly correlated with ∆eccentricity. In Group 2, hMPS significantly correlated with K2, Kmax, I-S index, and ∆coma, and hMPSy significantly correlated with I-S index and ∆coma. The mMPS significantly correlated with ∆CLMI. CONCLUSIONS: ICRS alone seems to be the most suitable option to improve visual acuity, whereas combined ICRS+CXL provided better corneal regularizing results. Preoperative peak strain (hMPS) was predictive of the extent of regularization and flattening after ICRS+CXL.


Assuntos
Substância Própria , Ceratocone , Colágeno , Substância Própria/cirurgia , Topografia da Córnea , Reagentes de Ligações Cruzadas , Análise de Elementos Finitos , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/cirurgia , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Implantação de Prótese , Refração Ocular , Estudos Retrospectivos , Riboflavina/uso terapêutico