Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 94(30): 10754-10763, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35862487

RESUMO

The structural, morphological, and chemical characterization of samples is of utmost importance for a large number of scientific fields. Furthermore, this characterization very often needs to be performed in three dimensions and at length scales down to the nanometer. Therefore, there is a stringent necessity to develop appropriate instrumentational solutions to fulfill these needs. Here we report on the deployment of magnetic sector secondary ion mass spectrometry (SIMS) on a type of instrument widely used for such nanoscale investigations, namely, focused ion beam (FIB)-scanning electron microscopy (SEM) instruments. First, we present the layout of the FIB-SEM-SIMS instrument and address its performance by using specific test samples. The achieved performance can be summarized as follows: an overall secondary ion beam transmission above 40%, a mass resolving power (M/ΔM) of more than 400, a detectable mass range from 1 to 400 amu, a lateral resolution in two-dimensional (2D) chemical imaging mode of 15 nm, and a depth resolution of ∼4 nm at 3.0 keV of beam landing energy. Second, we show results (depth profiling, 2D imaging, three-dimensional imaging) obtained in a wide range of areas, such as battery research, photovoltaics, multilayered samples, and life science applications. We hereby highlight the system's versatile capability of conducting high-performance correlative studies in the fields of materials science and life sciences.


Assuntos
Imageamento Tridimensional , Espectrometria de Massa de Íon Secundário , Imageamento Tridimensional/métodos , Fenômenos Magnéticos , Microscopia Eletrônica de Varredura
2.
Ultramicroscopy ; 228: 113334, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34102569

RESUMO

In this study atom probe tomography was used to determine the implantation depth of four different plasma FIB ion species - xenon, argon, nitrogen, and oxygen - implanted at different acceleration voltages. It was found that lowering the beam energy reduces the implantation depth, but significant implantation was still observed for N, O and Ar at beam energies as low as 2 kV. Furthermore, nitrides and oxides were observed that were formed when using N and O. Xe had the lowest implantation depth compared to Ar, N and O when using the same conditions. No Xe ions were detected in the sample prepared at 2 kV. Experimentally-determined implantation depths were compared to calculated implantation depths. The experiments exhibited deeper-than-predicted ion implantation into the microstructure, but lower-than-predicted ion concentrations.

3.
Sci Rep ; 11(1): 21599, 2021 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-34732755

RESUMO

Aberration-corrected scanning transmission electron microscopy (STEM) is widely used for atomic-level imaging of materials but severely requires damage-free and thin samples (lamellae). So far, the preparation of the high-quality lamella from a bulk largely depends on manual processes by a skilled operator. This limits the throughput and repeatability of aberration-corrected STEM experiments. Here, inspired by the recent successes of "robot scientists", we demonstrate robotic fabrication of high-quality lamellae by focused-ion-beam (FIB) with automation software. First, we show that the robotic FIB can prepare lamellae with a high success rate, where the FIB system automatically controls rough-milling, lift-out, and final-thinning processes. Then, we systematically optimized the FIB parameters of the final-thinning process for single crystal Si. The optimized Si lamellae were evaluated by aberration-corrected STEM, showing atomic-level images with 55 pm resolution and quantitative repeatability of the spatial resolution and lamella thickness. We also demonstrate robotic fabrication of high-quality lamellae of SrTiO3 and sapphire, suggesting that the robotic FIB system may be applicable for a wide range of materials. The throughput of the robotic fabrication was typically an hour per lamella. Our robotic FIB will pave the way for the operator-free, high-throughput, and repeatable fabrication of the high-quality lamellae for aberration-corrected STEM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA