Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cardiol Young ; 32(1): 48-54, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33998424

RESUMO

OBJECTIVE: To assess the feasibility of percutaneous transcatheter device closure of ventricular septal defects in children weighing less than 10 kg. BACKGROUND: Although percutaneous transcatheter device closure of ventricular septal defect is a well-established method of treatment in older children and adolescents, there is limited data on device closure in small children weighing less than 10 kg. We present our institutional experience of transcatheter VSD closure in children weighing less than 10 kg. METHOD: Medical records were reviewed for 16 children, who were selected for device closure of ventricular septal defects based on the inclusion criteria. RESULTS: Out of 65 patients with a diagnosis of ventricular septal defect, 16 children less than 10 kg were attempted for percutaneous device closure. In 13 patients, the device was successfully released, and 3 patients needed surgical closure of the defect. Mean age and weight of the patients were 17.3 ± 12.7 months and 6.8 ± 3.2 kg, respectively. Mean defect size was 6 mm (range 3-10). There was no incidence of device embolisation or heart block or death. Five patients had residual left-to-right shunt immediately after the device release, which got closed by the first month's follow-up. We had one accidental perforation of right ventricular free wall at the time of crossing of the defect, which was successfully repaired surgically. CONCLUSION: Percutaneous device closure of ventricular septal defect in small children with weight below 10 kg is feasible with good short-term outcome. Careful patient selection is essential for procedural success and to avoid complications.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Adolescente , Cateterismo Cardíaco , Criança , Comunicação Interventricular/cirurgia , Humanos , Encaminhamento e Consulta , Centros de Atenção Terciária , Atenção Terciária à Saúde , Resultado do Tratamento
2.
Ann Pediatr Cardiol ; 17(2): 101-108, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39184123

RESUMO

Introduction: The study aims to assess the procedural outcomes and follow-up after transcatheter closure of ventricular septal defects (VSDs) in children utilizing the Konar-MF™ occluder (Lifetech Scientific, Shenzhen, PRC) device. Materials and Methods: Clinical features, demographic characteristics, and follow-up findings of children undergoing percutaneous VSD device closure were retrospectively analyzed from the medical records. Results: Fifty-seven patients underwent VSD closure using the Konar-MF occluder between January 2019 and April 2023. Median age and body weight of patients were 36 (5-216) months and 12.5 (3.8-42) kg, respectively. The mean size of the defect on the left ventricular side was 6.5 ± 2.4 mm on echocardiography; the mean pulmonary artery pressure was 19.1 ± 9.7 mmHg. Three patients with severe pulmonary hypertension had successful device closure. The most used device size was 8 mm × 6 mm. The initially chosen device was upsized in 4 (7.01%) patients and downsized in 1 (1.7%) patient. Forty-five patients (78.9%) had device closure through the retrograde route. The procedure was successful in 53 (93.0%) patients. Immediate shunt occlusion was achieved in 86.8% of patients. Major complications, namely, embolization (1) and moderate aortic regurgitation (1) in two patients were successfully managed by surgery. One patient with severe tricuspid regurgitation has been on close follow-up. There was no mortality. Late complications such as valve regurgitation or rhythm disturbance were not identified on a median follow-up of 6 (1.5-47) months. Conclusion: Transcatheter VSD closure using a Konar-MF occluder device is safe and effective, even in smaller children. The ability to deliver both anterogradely and retrogradely is a unique advantage.

3.
Ann Pediatr Cardiol ; 16(4): 293-296, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38343506

RESUMO

Unilateral absence of pulmonary artery (UAPA) can be either isolated or associated with other congenital cardiac defects. It is a rare congenital lesion with a diverse clinical presentation. We present a case of absent right pulmonary artery and large patent ductus arteriosus (PDA) with severe unilateral pulmonary hypertension. We describe our strategy of staged ductus arteriosus closure in this patient and successful outcome on long term follow up.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA