1.
J Arthroplasty ; 29(10): 2049-52, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24997654

RESUMO

Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Adulto , Idoso , Materiais Biocompatíveis , Ligas de Cromo , Corrosão , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Titânio
2.
J Arthroplasty ; 28(6): 1036-40, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23528551

RESUMO

The primary goal of this study was to determine if head size affects corrosion and fretting behaviour at the head-neck taper interface of modular hip prostheses. Seventy-four implants were retrieved that featured either a 28 mm or a 36 mm head with a metal-on-polyethylene articulation. The bore of the heads and the neck of the stems were divided into eight regions each and graded by three observers for corrosion and fretting damage separately using modified criteria as reported in the literature. The 36 mm head size featured a significant difference in the corrosion head scores (p=0.022) in comparison to the 28 mm heads. This may be attributed to a greater torque acting along the taper interface due to activities of daily living.


Assuntos
Prótese de Quadril , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia , Idoso , Corrosão , Feminino , Humanos , Masculino