Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Phys ; 37(4): 1440-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443465

RESUMO

PURPOSE: Acoustic radiation force-optical coherence elastography (ARF-OCE) systems are novel imaging systems that have the potential to simultaneously quantify and characterize the optical and mechanical properties of in vivo tissues. This article presents the construction of bladder wall phantoms for use in ARF-OCE systems. Mechanical, acoustic, and optical properties are reported and compared to published values for the urinary bladder. METHODS: The phantom consisted of 0.2000 +/- 0.0089 and 6.0000 +/- 0.2830 microm polystyrene microspheres (Polysciences Inc., Warrington, PA, Catalog Nos. 07304 and 07312), 7.5 +/- 1.5 microm copolymer microspheres composed of acrylonitrile and vinylidene chloride, (Expancel, Duluth, GA, Catalog No. 461 DU 20), and bovine serum albumin within a gelatin matrix. Young's modulus was measured by successive compression of the phantom and obtaining the slope of the resulting force-displacement data. Acoustic measurements were performed using the transmission method. The phantoms were submerged in a water bath and placed between transmitting and receiving 13 mm diameter unfocused transducers operating at a frequency of 3.5 MHz. A MATLAB algorithm to extract the optical scattering coefficient from optical coherence tomography (OCT) images of the phantom was used. RESULTS: The phantoms possess a Young's modulus of 17.12 +/- 2.72 kPa, a mass density of 1.05 +/- 0.02 g/cm3, an acoustic attenuation coefficient of 0.66 +/- 0.08 dB/cm/MHz, a speed of sound of 1591 +/- 8.76 m/s, and an optical scattering coefficient of 1.80 +/- 0.23 mm(-1). Ultrasound and OCT images of the bladder wall phantom are presented. CONCLUSIONS: A material that mimics the mechanical, optical, and acoustic properties of healthy bladder wall has been developed. This tissue-mimicking bladder wall phantom was developed as a control tool to investigate the feasibility of using ARF-OCE to detect the mechanical and optical changes that may be indicative of the onset or development of cancer in the urinary bladder. By following the methods used in this article, phantoms matching the optical, acoustic, and mechanical properties of other biological tissues can also be constructed.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imagens de Fantasmas , Acústica , Elasticidade , Desenho de Equipamento , Humanos , Microesferas , Modelos Estatísticos , Óptica e Fotônica , Oscilometria , Poliestirenos/química , Pressão , Reprodutibilidade dos Testes , Software , Bexiga Urinária/patologia
2.
Med Phys ; 40(11): 111910, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24320443

RESUMO

PURPOSE: Optical/acoustic radiation imaging (OARI) is a novel imaging modality being developed to interrogate the optical and mechanical properties of soft tissues. OARI uses acoustic radiation force to generate displacement in soft tissue. Optical images before and after the application of the force are used to generate displacement maps that provide information about the mechanical properties of the tissue under interrogation. Since the images are optical images, they also represent the optical properties of the tissue as well. In this paper, the authors present the first imaging probe that uses acoustic radiation force in conjunction with optical coherence tomography (OCT) to provide information about the optical and mechanical properties of tissues to assist in the diagnosis and staging of epithelial cancers, and in particular bladder cancer. METHODS: The OARI prototype probe consisted of an OCT probe encased in a plastic sheath, a miniaturized transducer glued to a plastic holder, both of which were encased in a 10 cm stainless steel tube with an inner diameter of 10 mm. The transducer delivered an acoustic intensity of 18 W/cm(2) and the OCT probe had a spatial resolution of approximately 10-20 µm. The tube was filled with deionized water for acoustic coupling and covered by a low density polyethylene cap. The OARI probe was characterized and tested on bladder wall phantoms. The phantoms possessed Young's moduli ranging from 10.2 to 12 kPa, mass density of 1.05 g/cm(3), acoustic attenuation coefficient of 0.66 dB/cm MHz, speed of sound of 1591 m/s, and optical scattering coefficient of 1.80 mm(-1). Finite element model (FEM) theoretical simulations were performed to assess the performance of the OARI probe. RESULTS: The authors obtained displacements of 9.4, 8.7, and 3.4 µm for the 3%, 4%, and 5% bladder wall phantoms, respectively. This shows that the probe is capable of generating optical images, and also has the ability to generate and track displacements in tissue. This will provide information about the optical and mechanical properties of the tissue to assist in epithelial cancer detection. The corresponding theoretical FEM displacement was 5.8, 5.4, and 5.0 µm for the 3%, 4%, and 5% phantoms, respectively. Deviation between OARI displacement and FEM displacement is due to the resolution of the crosscorrelation algorithm used to track the displacement. To the authors' knowledge, this is the first probe that successfully combines OCT with a source of acoustic radiation force. CONCLUSIONS: The OARI probe has the ability to provide information about the mechanical and optical properties of phantoms and soft tissue. This could prove useful in early epithelial cancer detection. Because the probe is 10 mm in diameter, it is currently only useful for skin and oral applications. The probe would have to be reduced in size to make it applicable for cancer detection in other internal sites. Future work will focus on utilizing phase-sensitive optical coherence elastography to obtain the resulting OARI displacements, improving the resolution of the probe, and enable physicians to better evaluate the mechanical properties of soft tissues.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/diagnóstico , Acústica , Algoritmos , Calibragem , Progressão da Doença , Módulo de Elasticidade , Desenho de Equipamento , Humanos , Estadiamento de Neoplasias , Óptica e Fotônica , Imagens de Fantasmas , Radiografia , Reprodutibilidade dos Testes , Espalhamento de Radiação , Estresse Mecânico , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA