Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Pediatr Cardiol ; 45(3): 471-482, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38265483

RESUMO

Patent ductus arteriosus stenting (PDAS) for ductal-dependent pulmonary blood flow (DDPBF) provides a new paradigm for managing neonates with single ventricles (SV). Currently, sparse data exist regarding outcomes for subsequent palliation. We describe our experience with inter-stage care and stage 2 (S2P) conversion with PDAS in comparison to a prior era of patients who received surgical aorto-pulmonary shunts (APS). Retrospective review of 18 consecutive DDPBF SV patients treated with PDAS between 2016 and 2021 was done and compared with 9 who underwent APS from 2010 to 2016. Patient outcomes and pulmonary artery (PA) growth were analyzed. S2P was completed in all 18 with PDAS with no cardiac arrests and one post-S2P mortality. In the 9 APS patients, there was one cardiac arrest requiring ECMO and one mortality inter-stage. Off cardiopulmonary bypass strategy was utilized in 10/18 in the PDAS and 1/9 in the APS group (p = 0.005) at S2P. Shorter ventilation time, earlier PO feeding, and shorter hospital stay were noted in the PDAS group (p = 0.01, p = 0.006, p = 0.03) (S2P). Median Nakata index increase inter-stage was not significant between the PDAS and APS at 94.1 mm2/m2 versus 71.7 mm2/m2 (p = 0.94). Median change in pulmonary artery symmetry (PAS) was - 0.02 and - 0.24, respectively, which was statistically significant (p = 0.008). Neurodevelopmental outcomes were better in the PDAS group compared to the APS group (p = 0.02). PDAS provides excellent PA growth, inter-stage survival, progression along multistage single-ventricle palliation, and potentially improved neurodevelopmental outcomes. Most patients can be transitioned through 2 stages of palliation without CPB.


Assuntos
Permeabilidade do Canal Arterial , Coração Univentricular , Recém-Nascido , Humanos , Lactente , Circulação Pulmonar , Resultado do Tratamento , Cuidados Paliativos , Artéria Pulmonar , Stents , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos
2.
Pediatr Cardiol ; 44(2): 381-387, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36383234

RESUMO

The most significant sequelae of Kawasaki disease (KD) are coronary artery aneurysms, which can lead to risk of future myocardial ischemia. Exercise stress echocardiography allows for non-invasive assessment of myocardial dysfunction. We reviewed our single center experience with exercise stress echocardiography in patients with previous history of KD with coronary aneurysms. We reviewed the records of 53 KD patients who underwent exercise stress echocardiography from 2000 to 2020. Abnormal stress echocardiograms were defined as those showing no increase in biventricular systolic function post-exercise or regional wall motion abnormalities. Computed tomography angiography and cardiac magnetic resonance imaging were reviewed for patients with abnormal stress echocardiograms. Clinical data were reviewed and correlated with stress echocardiogram results. Of the 53 patients, three (5.7%) had an abnormal exercise stress echocardiogram. All three patients were classified as AHA Risk Level 4 or 5 by coronary Z-score (internal dimension normalized for body surface area) and were confirmed to have coronary aneurysms, stenosis, or myocardial tissue perfusion defects on advanced cardiac imaging that could account for the results seen on stress echocardiogram. Exercise stress echocardiography detected signs of myocardial ischemia in a subset of high-risk patients with Kawasaki disease and coronary aneurysms and may be considered as a useful screening tool for this complex patient cohort.


Assuntos
Aneurisma Coronário , Doença da Artéria Coronariana , Síndrome de Linfonodos Mucocutâneos , Isquemia Miocárdica , Humanos , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/etiologia , Ecocardiografia sob Estresse , Síndrome de Linfonodos Mucocutâneos/complicações , Doença da Artéria Coronariana/complicações , Isquemia Miocárdica/complicações , Teste de Esforço , Angiografia Coronária
3.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
4.
J Interv Cardiol ; 2022: 7602793, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36447937

RESUMO

Background: Fontan-associated liver disease is a well-known sequela following the Fontan procedure for patients living with single-ventricle heart disease. Pulmonary vasodilators, such as phosphodiesterase type 5 inhibitors, have emerged as a potential therapeutic option for lowering central venous pressures by reducing pulmonary vascular resistance. Method: We performed a single-center retrospective review of Fontan patients who were placed on pulmonary vasodilator therapy with prehemodynamic and posthemodynamic, MR elastography, and histologic assessments. Results: A total of 125 patients with Fontan circulation underwent surveillance with cardiac catheterization during the review period. Fifty-three (42%) patients who did not have increased end-diastolic pressures at the time of cardiac catheterization were started on phosphodiesterase type 5 inhibitor therapy. Nine patients (17%) underwent posttherapy follow-up catheterization. The mean Fontan pressure decreased from 15.4 ± 3.3 mmHg to 13.3 ± 2.5 mmHg (p=0.026), after initiation of pulmonary vasodilatory therapy. There was no change in end-diastolic pressure, transpulmonary gradient, wedge pressure, pulmonary vascular resistance, cardiac index, or saturation. Eleven patients (21%) underwent pretherapy MR elastography testing with posttherapy follow-up MR elastography. We found no improvement in liver stiffness score following the application of pulmonary vasodilators. Three patients underwent pretherapy and posttherapy liver biopsies, with variable histological changes observed within the hepatic parenchyma. Conclusions: These data demonstrate indeterminate results for the selective use of pulmonary vasodilators but highlight the need for large prospective randomized control trials of pulmonary vasodilator therapies to fully assess the benefit of such therapies in Fontan-associated liver disease.


Assuntos
Cateterismo Cardíaco , Vasodilatadores , Humanos , Vasodilatadores/uso terapêutico , Estudos Prospectivos , Biópsia , Fígado
5.
J Cardiothorac Vasc Anesth ; 36(3): 707-712, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34175203

RESUMO

OBJECTIVE: To determine if patients with congenital heart disease are undergoing laparoscopic surgery requiring abdominal insufflation and to compare the outcomes of these procedures with those who underwent an open surgical approach. DESIGN, SETTING, PARTICIPANTS: This was a retrospective study using the National Inpatient Sample from 2006 to 2014. Individuals with congenital heart disease who underwent at least one of six selected surgical procedures (laparoscopic or open) were included in the study. Subgroup analysis was performed on patients with Fontan palliation. MEASUREMENTS AND MAIN RESULTS: The primary outcome was to determine the frequency with which congenital heart disease patients undergo laparoscopic surgery requiring abdominal insufflation compared with open surgery. Secondary outcomes included all-cause in-hospital mortality and in-hospital length of stay. Of the 5,527 patients included, nearly half underwent laparoscopic surgery (46.3%), and 128 (2.3%) had single-ventricle circulation. All-cause mortality was significantly higher for those who underwent open surgery compared with the laparoscopic approach (3.6% v 0.9%; odds ratio [OR], 4.0 [2.6-6.3]; p < 0.0001). Subgroup analysis of patients with Fontal palliation older than five years showed 30 (42%) underwent laparoscopic surgery and there was no mortality difference between the laparoscopic and open approaches (OR, 1.4 [0.2-21.3], p = 0.8). Length of stay was significantly shorter for patients undergoing laparoscopic compared with open surgery (median three days [interquartile range, two-five] v six days [three-13], p < 0.0001). CONCLUSIONS: Individuals with congenital heart disease are being offered laparoscopic surgery that requires abdominal insufflation. All-cause mortality and length of stay were higher for patients who underwent open surgical operations.


Assuntos
Cardiopatias Congênitas , Insuflação , Laparoscopia , Cardiopatias Congênitas/cirurgia , Mortalidade Hospitalar , Humanos , Tempo de Internação , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Pediatr Cardiol ; 43(8): 1716-1722, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35430709

RESUMO

We report our experience with transcatheter patent ductus arteriosus (PDA) closure in premature infants and compare patients grouped by the device used for closure: the Microvascular Plug, "MVP" (Medtronic, Minneapolis, MN); Micro Plug Set, "Micro Plug" (KA Medical, Minneapolis, MN); and Amplatzer Piccolo Occluder, "Piccolo" (Abbot, Santa Clara, CA). We also report trends in device selection over time. Studies examining outcomes according to device selection for PDA closure in premature infants are lacking. We performed a retrospective review of all percutaneous PDA closures in premature infants at a single center (June 2018-May 2021). Patients were grouped by initial device selected for PDA closure (intention to treat). Institutional Review Board approval was obtained. 58 premature infants [MVP (n = 25), Micro Plug (n = 25), and Piccolo (n = 8)] underwent successful transcatheter PDA closure (mean gestational age 27 weeks 2 days; mean weight at procedure 1.4 kg; mean age at procedure 28 days). Pre-procedural demographics, procedural data, and follow-up data were similar between groups. There were no significant procedural adverse events. Three devices (2 MVP, 0 Micro Plug, 1 Piccolo p = 0.27) embolized after the procedure. One other device was removed for concern for aortic obstruction. Device selection evolved with a clear trend toward the Micro Plug device over time. Demographic, procedural, and follow-up data were similar between the MVP, Micro Plug, and Piccolo groups. The Micro Plug did not require exchange for suboptimal fitting or embolize and became our preferred device in most cases.


Assuntos
Permeabilidade do Canal Arterial , Doenças do Prematuro , Dispositivo para Oclusão Septal , Recém-Nascido , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Recém-Nascido Prematuro , Estudos Retrospectivos
7.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743224

RESUMO

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Assuntos
Comunicação Interatrial , Exposição à Radiação , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Comunicação Interatrial/cirurgia , Humanos , Melhoria de Qualidade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
8.
Pediatr Cardiol ; 43(4): 894-902, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34894280

RESUMO

Guidelines for management of Melody transcatheter pulmonary valve (TPV) infective endocarditis (IE) are lacking. We aimed to identify factors associated with surgical valve removal versus antimicrobial therapy in Melody TPV IE. Multicenter retrospective analysis of all patients receiving Melody TPV from 10/2010 to 3/2019 was performed to identify cases of IE. Surgical explants versus non-surgical cases were compared. Of the 663 Melody TPV implants, there were 66 cases of IE in 59 patients (59/663, 8.8%). 39/66 (59%) were treated with IV antimicrobials and 27/66(41%) underwent valve explantation. 26/59 patients (44%) were treated medically without explantation or recurrence with average follow-up time of 3.5 years (range:1-9). 32% of Streptococcus cases, 53% of MSSA, and all MRSA cases were explanted. 2 of the 4 deaths had MSSA. CART analysis demonstrated two important parameters associated with explantation: a peak echo gradient ≥ 47 mmHg at IE diagnosis(OR 10.6, p < 0.001) and a peak echo gradient increase of > 24 mmHg compared to baseline (OR 6.7, p = 0.01). Rates of explantation varied by institution (27 to 64%). In our multicenter experience, 44% of patients with Melody IE were successfully medically treated without valve explantation or recurrence. The degree of valve stenosis at time of IE diagnosis was strongly associated with explantation. Rates of explantation varied significantly among the institutions.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
9.
J Physiol ; 599(1): 343-356, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33026102

RESUMO

KEY POINTS: The distribution of pulmonary perfusion is affected by gravity, vascular branching structure and active regulatory mechanisms, which may be disrupted by cardiopulmonary disease, but this is not well studied, particularly in rare conditions. We evaluated pulmonary perfusion in patients who had undergone Fontan procedure, patients with pulmonary arterial hypertension (PAH) and two groups of controls using a proton magnetic resonance imaging technique, arterial spin labelling to measure perfusion. Heterogeneity was assessed by the relative dispersion (SD/mean) and gravitational gradients. Gravitational gradients were similar between all groups, but heterogeneity was significantly increased in both patient groups compared to controls and persisted after removing contributions from large blood vessels and gravitational gradients. Patients with Fontan physiology and patients with PAH have increased pulmonary perfusion heterogeneity that is not explainable by differences in mean perfusion, gravitational gradients, or large vessel anatomy. This probably reflects vascular remodelling in PAH and possibly in Fontan physiology. ABSTRACT: Many factors affect the distribution of pulmonary perfusion, which may be disrupted by cardiopulmonary disease, but this is not well studied, particularly in rare conditions. An example is following the Fontan procedure, where pulmonary perfusion is passive, and heterogeneity may be increased because of the underlying pathophysiology leading to Fontan palliation, remodelling, or increased gravitational gradients from low flow. Another is pulmonary arterial hypertension (PAH), where gravitational gradients may be reduced secondary to high pressures, but remodelling may increase perfusion heterogeneity. We evaluated regional pulmonary perfusion in Fontan patients (n = 5), healthy young controls (Fontan control, n = 5), patients with PAH (n = 6) and healthy older controls (PAH control) using proton magnetic resonance imaging. Regional perfusion was measured using arterial spin labelling. Heterogeneity was assessed by the relative dispersion (SD/mean) and gravitational gradients. Mean perfusion was similar (Fontan = 2.50 ± 1.02 ml min-1  ml-1 ; Fontan control = 3.09 ± 0.58, PAH = 3.63 ± 1.95; PAH control = 3.98 ± 0.91, P = 0.26), and the slopes of gravitational gradients were not different (Fontan = -0.23 ± 0.09 ml min-1  ml-1  cm-1 ; Fontan control = -0.29 ± 0.23, PAH = -0.27 ± 0.09, PAH control = -0.25 ± 0.18, P = 0.91) between groups. Perfusion relative dispersion was greater in both Fontan and PAH than controls (Fontan = 1.46 ± 0.18; Fontan control = 0.99 ± 0.21, P = 0.005; PAH = 1.22 ± 0.27, PAH control = 0.91 ± 0.12, P = 0.02) but similar between patient groups (P = 0.13). These findings persisted after removing contributions from large blood vessels and gravitational gradients (all P < 0.05). We conclude that patients with Fontan physiology and PAH have increased pulmonary perfusion heterogeneity that is not explained by differences in mean perfusion, gravitational gradients, or large vessel anatomy. This probably reflects the effects of remodelling in PAH and possibly in Fontan physiology.


Assuntos
Técnica de Fontan , Hipertensão Arterial Pulmonar , Humanos , Pulmão , Perfusão , Circulação Pulmonar
10.
Cardiol Young ; 31(10): 1613-1618, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33641693

RESUMO

INTRODUCTION: Many newborns with pulmonary atresia/intact ventricular septum require intervention to establish pulmonary flow and sufficient cardiac output. The resulting haemodynamic changes are not well characterised and may have unintended consequences. METHODS: This is a 30-year (1988-2018) retrospective study of patients with pulmonary atresia intact ventricular septum. RESULTS: Eighty-nine patients were included, and median follow-up was 8 years. Fifty-five per cent had coronary sinusoids and 27% had right ventricular-dependent coronary circulation. Most patients were managed with surgical aortopulmonary or modified Blalock-Taussig shunt (73%), and 12 patients underwent balloon atrial septostomy before surgical intervention. The remaining patients (27%) underwent only transcatheter interventions; 7 required an atrial septostomy and 17 required ductal stentings. All-cause mortality was 10%, most deaths (89%) occurred before 18 months of age. Of these early deaths, 87% required a balloon atrial septostomy and 85% had right ventricular-dependent coronary sinusoids. Eighteen-month mortality was significantly higher for patients who required a balloon atrial septostomy compared to those who did not (36% versus 1.4% p < 0.0001). DISCUSSION: Patients with pulmonary atresia/intact ventricular septum who require balloon atrial septostomy in the newborn period have significantly higher 18-month mortality. Quantifying the mortality difference may help guide prognostication and expectation setting. Infants who had septostomy and a surgical shunt in the newborn period fared better than those who only underwent septostomy (even when accompanied by ductal stenting). For infants with right ventricular-dependent circulation, atrial septostomy should only be performed on an urgent or emergent basis and these patients should be considered for early surgical intervention and neonatal transplant.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Septo Interventricular , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Atresia Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia
11.
Catheter Cardiovasc Interv ; 96(7): 1439-1444, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32979038

RESUMO

OBJECTIVES: We intend to describe early experience using a new, commercially available Micro Plug Set for preterm neonate and infant transcatheter patent ductus arteriosus (PDA) occlusion. BACKGROUND: Transcatheter PDA occlusion in premature neonates and small infants is safe and effective. The procedure is early in its evolution. METHODS: Procedural and short-term outcomes of preterm neonates and infants undergoing transcatheter PDA occlusion with a new, commercially available device were reviewed. RESULTS: Eight preterm neonates and infants born at median 27 weeks gestation (23-36 weeks) underwent transcatheter PDA device closure with the Micro Plug Set. The device is short (2.5 mm) with a range of diameters (3, 4, 5, 6 mm) and delivered through a microcatheter. Procedures were performed at median 41 days of age (12-88 days) and at 1690 g (760-3,310 g). Transvenous PDA device occlusion was performed with fluoroscopic and echocardiography guidance. All procedures were successful with complete PDA occlusion. There were no procedural or short-term adverse events. CONCLUSIONS: Preterm neonate and infant transcatheter PDA device closure with a new, commercially available short and microcatheter delivered device (Micro Plug Set) was safe and effective in a small, early series of patients.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Peso ao Nascer , Cateterismo Cardíaco/efeitos adversos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Desenho de Equipamento , Idade Gestacional , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido , Recém-Nascido Prematuro , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 96(7): 1434-1438, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32926536

RESUMO

BACKGROUND: Patent ductus arteriosus (PDA) stenting is evolving as an alternative to surgical aorto-pulmonary shunts for infants with ductal-dependent pulmonary blood flow. Given anatomical proximity, the PDA can compress the ipsilateral bronchus. We report a case series of four patients with bronchial compression by a tortuous PDA who underwent PDA stenting. METHODS: Our four patients received PDA stents for ductal-dependent pulmonary blood flow despite preprocedure imaging evidence of bronchial compression. We reviewed the cross-sectional chest imaging to assess the degree of bronchial compression and the variables that affect it, namely PDA size, PDA tortuosity, and the anatomical relationship between the compressed bronchus and the PDA. RESULTS: Three out of the four patients had postprocedure imaging, and all showed relief of the previously seen bronchial compression. Post-PDA stenting patients had a smaller and straight PDA with significant lateralization away from the compressed bronchus. None of the four patients developed symptoms of bronchial compression poststenting. CONCLUSIONS: Our study suggests that pre-existing bronchial compression does not preclude PDA stenting. Stent placement in an engorged and tortuous PDA led to significant improvement in pre-existing bronchial compression. Improvement may be attributed to PDA shrinkage, straightening, and lateralization. Further studies are needed to confirm our findings.


Assuntos
Broncopatias/terapia , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Circulação Pulmonar , Stents , Broncopatias/diagnóstico por imagem , Broncopatias/etiologia , Broncopatias/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Constrição Patológica , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Humanos , Lactente , Recém-Nascido , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
13.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30506273

RESUMO

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Fluoroscopia/efeitos adversos , Cardiopatias Congênitas/cirurgia , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Adolescente , Criança , Pré-Escolar , Consenso , Humanos , Lactente , Estudos Prospectivos , Melhoria de Qualidade , Doses de Radiação , Medição de Risco/métodos , Fatores de Risco , Adulto Jovem
14.
J Card Surg ; 33(10): 653-657, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30199920

RESUMO

BACKGROUND: Dacron tube grafts have been used in the surgical management of cardiovascular disease since the 1970s. Complications at the site of the anastomosis have been well described. Non-anastomotic failure is far less common. We present a series of four patients who presented with complications of non-anastomotic failure of woven Dacron tube grafts. METHODS: A retrospective chart review of four patients who presented to our institution between March 2014 and March 2017 with clinical complications of a Dacron tube graft was conducted. RESULTS: All four patients underwent a staged surgical repair for an interrupted aortic arch between the years of 1988 and 2001. All four patients underwent revision of their original interposition graft (Gore-Tex, W.L. Gore & Associates, Flagstaff, AZ) with implantation of a Hemashield woven Dacron tube graft (Maquet, Rastatt, Germany). From 13 to 22 years postimplant of the Dacron tube graft, all patients presented with symptoms or clinical evidence of primary graft failure. Two patients underwent urgent surgical intervention and did not survive. One patient underwent attempted surgical intervention, which was aborted in the setting of profuse bleeding, and ultimately had an endovascular rescue of the tube graft with a Zenith Alpha endograft (Cook Medical, Bloomington, IN). One patient underwent elective endovascular intervention prior to onset of symptoms. CONCLUSION: Non-anastomotic failure of woven Dacron tube grafts can occur in the thoracic aorta in young adults and may be managed with endovascular techniques.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Polietilenotereftalatos/efeitos adversos , Falha de Prótese , Adolescente , Adulto , Evolução Fatal , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 90(4): 626-630, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471087

RESUMO

Despite few institutions stenting the ascending aorta, it has been discouraged because of the proximity of the aortic valve, the coronary artery orifices, and the aortic arch branches. We describe a small case series of patients having acquired stenosis of the ascending that was relieved successfully by stenting. © 2017 Wiley Periodicals, Inc.


Assuntos
Angioplastia com Balão/instrumentação , Aorta , Doenças da Aorta/terapia , Arteriopatias Oclusivas/terapia , Stents , Adulto , Aorta/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Criança , Angiografia por Tomografia Computadorizada , Constrição Patológica , Humanos , Masculino , Resultado do Tratamento , Adulto Jovem
16.
Catheter Cardiovasc Interv ; 90(6): 982-985, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28568976

RESUMO

The phenomenon of coronary steal is well known in the setting of HLHS (Hypoplastic Left Heart Syndrome) early after the Classical Norwood Operation. We report a rare case of an infant with HLHS [Severe Aortic Stenosis (AS), Mitral Stenosis (MS) and small Left Ventricle (LV)], who developed aortic regurgitation and presumed coronary steal late after the Sano Modification of the Norwood Procedure. Coronary steal developed secondary to progressive aortic and mitral regurgitation and resulted in poor right ventricular function and severe tricuspid regurgitation. We describe a novel interventional approach for obliteration of the LV cavity by using hydrogel coils. LV obliteration eliminated the presumed steal and resulted in improvement in ventricular function, tricuspid regurgitation and clinical course.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ventrículos do Coração/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos de Norwood/efeitos adversos , Complicações Pós-Operatórias , Dispositivo para Oclusão Septal , Angiografia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Lactente , Masculino , Reoperação
17.
Catheter Cardiovasc Interv ; 88(7): 1108-1112, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27527119

RESUMO

OBJECTIVES: To examine the factors contributing to arterial thrombosis after catheterization, particularly the use of long vs. short introducer sheaths, and propose a new protocol to address risks. BACKGROUND: Post-procedure arterial compromise is an important concern in pediatric cardiac catheterizations. For certain interventional procedures, the use of a long sheath is necessary, however, the incidence of complications when using such sheaths has not yet been studied. METHODS: This retrospective review includes patients <15 kg who underwent femoral artery catheterization at our institution from Feb 2006 to June 2014. The study examined 29 long sheath and 40 matched interventional short sheath cases. Data collected included age, weight, time to arterial access, total sheath duration, and arterial complications. The long sheath and short sheath groups, and confounding factors, were compared for complication rate. RESULTS: The incidence of arterial compromise was 38% (11/29) in the long sheath group compared to 15% (6/40) for short sheaths (P = 0.029). Arterial thrombosis was documented by ultrasound, CT, or angiography in 71% (12/17) patients. Time to arterial access and total sheath duration were not statistically significant factors. Weight was an independent risk factor, with infants <5 kg having a higher complication rate compared to infants >5 kg at 38.2% (13/34) and 11.4% (4/35), respectively (P = 0.004). Sheath length remained statistically significant after taking weight and age into account (P = 0.011). CONCLUSION: The use of a long sheath in infants <15 kg is a significant risk factor for arterial compromise compared to short sheaths. Lower patient weight is also a contributing factor to increased incidence of complication, particularly in those <5 kg. © 2016 Wiley Periodicals, Inc.


Assuntos
Arteriopatias Oclusivas/epidemiologia , Cateterismo Periférico/efeitos adversos , Artéria Femoral , Trombose/epidemiologia , Fatores Etários , Anticoagulantes/administração & dosagem , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/tratamento farmacológico , Peso Corporal , California/epidemiologia , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Pré-Escolar , Protocolos Clínicos , Angiografia por Tomografia Computadorizada , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Fibrinolíticos/administração & dosagem , Heparina/administração & dosagem , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Punções , Estudos Retrospectivos , Fatores de Risco , Terapia Trombolítica , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Fatores de Tempo , Ativador de Plasminogênio Tecidual/administração & dosagem , Ultrassonografia Doppler , Dispositivos de Acesso Vascular
18.
Pediatr Cardiol ; 37(8): 1436-1445, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27502109

RESUMO

The Congenital Cardiac Catheterization Project on Outcomes (C3PO) launched in 2007 as a multi-center collaborative to establish standardized and comparable metrics for pediatric cardiac catheterization procedures. The limitations of larger registries at the time led to the development of the next phase in 2013, C3PO-Quality Improvement (C3PO-QI), focusing on instituting QI initiatives within the field. The objective of this manuscript is to provide a detailed overview of C3PO-QI and report data on case characteristics and outcome metrics being explored. C3PO-QI was designed to cultivate institutional collaboration during implementation of its initiatives. A database and website were developed to support data entry and on-demand reporting. The registry prospectively captures pediatric cardiac catheterization data among 15 hospitals. The present study includes case demographic data (n) and quality metric reporting by case type, age, and radiation dose variables. This dataset includes 13,135 cases entered into the database between 1/1/2014 and 12/31/2015. Interventional cases make up the highest percentage by case mix distribution (48 %), and patients <1 years make up the highest percentage by age distribution (26 %). The ratio of diagnostic and interventional procedures performed changes by age group. Application of QI metric shows all procedure types surpassing metric goals. Large volume data collection, such as in C3PO-QI, allows for meaningful interpretation of data. C3PO-QI is uniquely poised to deliver fast-paced changes in the field. Although the project initiatives are specific to pediatric cardiac catheterization, the implementation of the project and utilization of real-time reporting is generalizable to other specialties and multi-center collaboratives.


Assuntos
Cateterismo Cardíaco , Criança , Bases de Dados Factuais , Cardiopatias Congênitas , Humanos , Melhoria de Qualidade , Sistema de Registros
20.
Catheter Cardiovasc Interv ; 85(5): 832-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25504498

RESUMO

OBJECTIVE: Bronchial compression as a result of pulmonary artery and aortic arch stenting may cause significant respiratory distress. We set out to limit airway narrowing by endovascular stenting, by using simultaneous flexible bronchoscopy and graduated balloon stent dilatation, or balloon angioplasty to determine maximum safe stent diameter. METHODS: Between August 2010 and August 2013, patients with suspected airway compression by adjacent vascular structures, underwent CT or a 3D rotational angiogram to evaluate the relationship between the airway and the blood vessels. If these studies showed close proximity of the stenosed vessel and the airway, simultaneous bronchoscopy and graduated stent re-dilation or graduated balloon angioplasty were performed. RESULTS: Five simultaneous bronchoscopy and interventional catheterization procedures were performed in four patients. Median age/weight was 33 (range 9-49) months and 14 (range 7.6-24) kg, respectively. Three had hypoplastic left heart syndrome, and one had coarctation of the aorta (CoA). All had confirmed or suspected left main stem bronchial compression. In three procedures, serial balloon dilatation of a previously placed stent in the CoA was performed and bronchoscopy was used to determine the safest largest diameter. In the other two procedures, balloon testing with simultaneous bronchoscopy was performed to determine the stent size that would limit compression of the adjacent airway. In all cases, simultaneous bronchoscopy allowed selection of an ideal caliber of the stent that optimized vessel diameter while minimizing compression of the adjacent airway. CONCLUSION: In cases at risk for airway compromise, flexible bronchoscopy is a useful tool to guide endovascular stenting. Maximum safe stent diameter can be determined without risking catastrophic airway compression.


Assuntos
Obstrução das Vias Respiratórias/prevenção & controle , Coartação Aórtica/complicações , Broncoscopia/métodos , Procedimentos Endovasculares/métodos , Síndrome do Coração Esquerdo Hipoplásico/complicações , Stents , Cirurgia Assistida por Computador/métodos , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/etiologia , Angiografia , Angioplastia com Balão/métodos , Coartação Aórtica/diagnóstico , Coartação Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Pré-Escolar , Feminino , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Imageamento Tridimensional , Lactente , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA