Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Surg Endosc ; 38(3): 1180-1190, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38082007

RESUMO

BACKGROUND: Achalasia is a rare disorder of the esophagus characterized by motor dysfunction in the esophagus and relaxation failure of the lower esophageal sphincter (LES). Currently, surgical myotomy procedures are considered the standard of care. Robotic Heller's myotomy (RHM) with fundoplication has been gaining popularity due to documented advantages in the precision of myotomy as well as avoiding the potential reflux following per-oral endoscopic myotomy (POEM). To the best of our knowledge, RHM has thus far has been performed exclusively by the da Vinci surgical system. The new Hugo RAS™ system offers a unique modular design and an open console which offers better maneuverability and docking options. In this study, we present the first worldwide series of patients undergoing RHM using the new Hugo RAS™ platform. Our objective is to propose optimal operating configuration and setup to fully harness the advantages of the unique modular design of this system. METHODS: Ten consecutive achalasia patients underwent Robotic Heller's myotomy (RHM) with the Hugo RAS™ system. We prospectively collected patient data, including demographics, comorbidities, ASA class, Eckardt scores, pre-operative manometric data, and EndoFlip parameters. Additionally, we recorded the docking and total operative times. RESULTS: Between December 2022 and August 2023, 10 patients underwent RHM with the Hugo™ RAS system. Patients had a median age of 42.5 years, 60% were female, and mean BMI was 23.2. Fifty percent had achalasia type 2 and 50% type 1. The median pre-operative integrated relaxation pressure (IRP) was 24.9. Median docking time was 10 min and overall operative time was 129.5 min. All patients, except one with acute coronary syndrome, had an uneventful peri-operative course and were discharged on post-operative day 2. CONCLUSION: The Hugo™ RAS system is well designed for robotic Heller myotomy. The operative and clinical results are similar to the currently used robotic system; however, the modular design of the system has some differences. These translate to better docking angles and maneuverability as well as console surgeon's ergonomics. Further experience is needed to explore the advantages of the system's modular design and function.


Assuntos
Acalasia Esofágica , Miotomia de Heller , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Adulto , Masculino , Acalasia Esofágica/cirurgia , Resultado do Tratamento , Laparoscopia/métodos , Esfíncter Esofágico Inferior/cirurgia
2.
Minim Invasive Ther Allied Technol ; 32(6): 300-306, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37603037

RESUMO

INTRODUCTION: Robotic-assisted surgery has been a part of surgical procedures for more than two decades. Recently new robotic platforms with a different design entered the market. The modular design with independent arms enables increased flexibility of arm docking to increase the range of motion and instrument maneuverability. We herein present the first case series of robotic inguinal hernia repair using the Hugo RAS system (Medtronic, Minneapolis, MN, USA). MATERIAL AND METHODS: Thirteen inguinal hernia repairs were performed on ten patients. A description of the Hugo RAS system as well as the new concept of modular design is presented along with the description of the operation setup. RESULTS: Mean docking time was 9.5 min and mean console time was 50.3 min and 74.7 min for unilateral and bilateral inguinal hernia repair, respectively. No intraoperative or postoperative complications occurred. There was one conversion to laparoscopic surgery due to a technical issue with the robot. Conclusions: The modular design of independent arms seems to enhance maneuverability of the instruments and contribute to fewer arm collisions. Further clinical data and experience with this new surgical system are necessary to understand if this new design has advantages over the standard robotic platforms.


Assuntos
Hérnia Inguinal , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Hérnia Inguinal/cirurgia , Laparoscopia/métodos , Complicações Pós-Operatórias , Herniorrafia/métodos , Estudos Retrospectivos
3.
Minim Invasive Ther Allied Technol ; 31(4): 635-641, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33529074

RESUMO

BACKGROUND: Complete or partial fundoplication remains controversial for the surgical treatment of GERD. While partial fundoplication is considered less effective, it is associated with less post-operative dysphagia and gas bloating compared with complete fundoplication. AIM: To compare the mechanical efficiency of the three different types of fundoplication. MATERIAL AND METHOD: Two studies of the LES were performed on explanted stomachs: distensibility and failure point. Measurements were taken before and after fundoplication. RESULTS: There was no difference in distensibility between Nissen and Toupet fundoplication, however, the EGJ was more distensible following Dor fundoplication. According to failure point measurements, Nissen fundoplication was significantly more effective than Toupet, Toupet was significantly more effective than Dor (p = .016, p = .017, respectively). CONCLUSIONS: There were significant differences in distensibility between Dor and both Nissen and Toupet, however no statistical difference between Toupet and Nissen. There was a significant difference in effectiveness between all three types of fundoplication according to the failure point. These laboratory findings demonstrate that the mechanical orientation of Nissen and Toupet have similar functionality suggesting that Toupet is as good as Nissen. While in clinical studies Toupet has fewer post-operative complications these findings support the proponents of Toupet for GERD. Abbreviation: GERD: Gastroesophageal reflux disease.


Assuntos
Fundoplicatura , Refluxo Gastroesofágico , Fundoplicatura/efeitos adversos , Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Humanos , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
4.
Int J Obes (Lond) ; 45(9): 1925-1936, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33980995

RESUMO

BACKGROUND: The appropriate strategies to minimize skeletal deterioration following bariatric surgeries are inconclusive. This randomized controlled trial evaluated the effect of preoperative vitamin supplementation on bone mineral density (BMD) and biochemical parameters in females post-sleeve gastrectomy (SG). METHODS: Participants were randomized to a 2-month preoperative treatment with a multivitamin and vitamin D 4000 IU/d (intervention arm) or 1200 IU/d (control arm). Preoperative and 12-month postoperative follow-up evaluations included anthropometrics, biochemical parameters, and dual energy X-ray absorptiometry (DEXA). RESULTS: Sixty-two females (median age 29.7 years and median BMI 43.4 kg/m2) were recruited, 87% completed the 12-month follow-up. For the intervention and control arms, significant and similar reductions at 12-months post-surgery were observed in BMD of the hip (-6.8 ± 3.7% vs. -6.0 ± 3.6%; P = 0.646) and of the femoral neck (-7.1 ± 5.8% vs. -7.2 ± 5.5%; P = 0.973). For the intervention compared to the control arm, the 25 hydroxyvitamin D (25(OH)D) increment was greater after 2 months treatment, and vitamin D deficiency rates were lower at 3 and 6-months follow-up (P < 0.016). However, at 12-months postoperative, 25(OH)D values and vitamin D deficiency were comparable between the arms (P > 0.339). Predictors for BMD decline in the total hip were the percentage of excess weight-loss, age>50 years, and lower initial BMI (P ≤ 0.003). CONCLUSIONS: SG was associated with a significant decline in BMD of the hip and femoral neck in young and middle-aged women, and was unaffected by preoperative vitamin D supplementation. Females who are peri-menopausal or with greater postoperative weight-loss should be particularly followed for BMD decline.


Assuntos
Densidade Óssea/efeitos dos fármacos , Gastrectomia/efeitos adversos , Cuidados Pré-Operatórios/normas , Vitaminas/administração & dosagem , Adulto , Distribuição de Qui-Quadrado , Suplementos Nutricionais/normas , Suplementos Nutricionais/estatística & dados numéricos , Feminino , Gastrectomia/métodos , Gastrectomia/estatística & dados numéricos , Humanos , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/estatística & dados numéricos , Vitaminas/uso terapêutico
5.
J Cell Mol Med ; 24(12): 6622-6633, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32336016

RESUMO

The study of the human response to injury has been hampered by the inherent heterogeneity in the models and methods used. By studying a standard injury longitudinally, using individual patient-level analysis, we endeavoured to better describe its dynamics. We analysed clinical variables, clinical laboratory and plasma cytokines from 20 patients at five time points. Clustering analysis showed two prototype patterns of cytokine behaviour: a concordant type, where cytokines behave the same way for all patients (notably IL-0 and TNFα), and a variable type, where different patterns of expression are seen for different patients (notably IL-8, IL-6 and IL-1RA). Analysis of the cytokines at the individual patient-level showed a strong four-way correlation between IL-1RA, GCSF, MIP-1ß and MCP-1. As it holds for most patients and not just on average, this suggests that they form a network which may play a central role in the response to gastro-intestinal injuries in humans. In conclusion, the longitudinal analysis of cytokines in a standard model allowed the identification of their underlying patterns of expression. We propose that the two prototype patterns shown may reflect the mechanism that separates the common and individual aspects of the injury response.


Assuntos
Citocinas/metabolismo , Gastrectomia , Laparoscopia , Adolescente , Adulto , Pressão Sanguínea , Creatinina/metabolismo , Citocinas/sangue , Feminino , Humanos , Leucócitos/metabolismo , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Sístole , Sinais Vitais , Adulto Jovem
6.
Artigo em Inglês | MEDLINE | ID: mdl-32015045

RESUMO

Bariatric surgery is increasingly performed in morbidly obese HIV patients. Limited data exist regarding antiretroviral drug exposure after bariatric surgery. We report a case of a morbidly obese HIV patient who underwent sleeve gastrectomy. Abacavir, lamivudine, and dolutegravir therapeutic drug monitoring was performed at several time points pre- and postsurgery. Significantly increased levels were measured, particularly for abacavir, whose levels increased ∼12-fold. Several mechanistic explanations for these findings are discussed.


Assuntos
Antirretrovirais/farmacocinética , Antirretrovirais/uso terapêutico , Cirurgia Bariátrica , Gastrectomia , Obesidade Mórbida/cirurgia , Adulto , Antirretrovirais/sangue , Didesoxinucleosídeos/sangue , Didesoxinucleosídeos/farmacocinética , Didesoxinucleosídeos/uso terapêutico , Monitoramento de Medicamentos , Infecções por HIV/tratamento farmacológico , Compostos Heterocíclicos com 3 Anéis/sangue , Compostos Heterocíclicos com 3 Anéis/farmacocinética , Compostos Heterocíclicos com 3 Anéis/uso terapêutico , Humanos , Lamivudina/sangue , Lamivudina/farmacocinética , Lamivudina/uso terapêutico , Masculino , Oxazinas/sangue , Oxazinas/farmacocinética , Oxazinas/uso terapêutico , Piperazinas/sangue , Piperazinas/farmacocinética , Piperazinas/uso terapêutico , Piridonas/sangue , Piridonas/farmacocinética , Piridonas/uso terapêutico
7.
Harefuah ; 158(4): 222-226, 2019 Apr.
Artigo em Hebraico | MEDLINE | ID: mdl-31032552

RESUMO

INTRODUCTION: Esophageal achalasia is a rare condition, characterised by progressive dysphagia due to innervation of the esophageal muscles and non-relaxation of the lower esophageal sphincter. The standard of care of surgical treatment is laparoscopic Heller myotomy. POEM-Peroral endoscopic myotomy is a new approach offering incision-less and selective myotomy. AIMS: This study aims to describe our experience and outcomes using this new surgical technique. METHODS: We performed a retrospective study using prospectively maintained data of all achalasia patients treated by POEM in our department. Data collected included patient demographics, gender, age, BMI, data related to the disease course in addition to data related to the surgery itself as well as both short and long term post-operative follow-up. RESULTS: Over the course of five years we performed 86 POEM operations, demonstrating a decrease in the Eckardt score from a mean of 8.87 to a mean of 0.7 in the immediate postoperative. Mean operative time was 86 minutes, with mean hospitalization time of 4 days. Intraoperative complications included 2 mucosal injuries while post-operative complications included 4 incomplete mucosal closures, 5 recurrent dysphagia and 5 patients with reflux requiring medical therapy. CONCLUSIONS: In the last decade, POEM procedure is being performed worldwide and has been performed in our department for the past five years. Our results show a success rate of 94.2% with minor complications. In our institution, as in many institutions globally, POEM is the preferred method for treating achalasia.


Assuntos
Acalasia Esofágica , Miotomia , Acalasia Esofágica/cirurgia , Esfíncter Esofágico Inferior , Humanos , Estudos Retrospectivos , Resultado do Tratamento
8.
Minim Invasive Ther Allied Technol ; 27(6): 321-326, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29616866

RESUMO

Introduction: Recently, magnetic solutions have been proposed to minimize surgical invasiveness. These are comprised of deployable instruments containing magnets which are inserted into the abdominal cavity through a single access point. The manipulation of the internal elements occurs via magnets held on the external surface of the abdominal wall. This technology relies on the magnetic force between the magnets, which is inversely related to the abdominal wall thickness (AWT). The aim of this study was to establish the expected change in AWT from before and after initiation of pneumoperitoneum. Material and methods: Patients scheduled for laparoscopic procedures were assessed by ultrasound for AWT immediately before and during laparoscopy. Change of AWT during laparoscopy was calculated. Statistical analysis was performed using Student's t-test. Results: Thirty-two patients undergoing various laparoscopic procedures were included. Twenty patients were male (62.5%) and ten were morbidly obese (31%). Mean age was 51 years (range 18-76) and average BMI was 28.1 kg/m2 (range 19.0-41.0). AWT decreased on average by 15.6% once pneumoperitoneum was initiated in both obese and non-obese patients (p = .01). Conclusion: Our data suggest that following preoperative assessment of AWT with abdominal wall ultrasound, more patients than expected might be candidates for the use of trans-abdominal magnetic devices.


Assuntos
Parede Abdominal/diagnóstico por imagem , Laparoscopia/métodos , Obesidade Mórbida/complicações , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
9.
Surg Endosc ; 30(12): 5428-5433, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27126622

RESUMO

BACKGROUND: The beneficial effect of bariatric surgery (BS) in type 2 diabetes mellitus patients is well established. Conversely, little is known about the efficacy of BS in type 1 diabetes mellitus (T1DM) patients, despite the increasing prevalence of obesity in this population. METHODS: A retrospective review was carried out on a prospectively collected bariatric surgery registry of all patients undergoing BS at two university hospitals between 2010 and 2015. Patients with T1DM were identified, and detailed chart reviews were obtained. RESULTS: In this time period, we operated on thirteen patients with T1DM. Eight were female (61.5 %). Median age at time of surgery was 38 ± 8.3 (range 28-53) years. The procedures performed were laparoscopic sleeve gastrectomy (n = 10) and laparoscopic Roux-en-Y gastric bypass (n = 3). On median postoperative follow-up of 24 (range 2.5-51) months, mean body mass index significantly decreased from 39.9 ± 4.1 to 30.1 ± 3.9 kg/m2 (P < 0.0001) and insulin requirements were significantly reduced from 83.7 ± 40.4 to 45.7 ± 33.1 U/day (P < 0.01). However, there was no significant change in glycemic control assessed by HbA1C (P = 0.2). During the first months following surgery, three patients (21.4 %) experienced diabetic ketoacidosis, and four patients (28.6 %) reported more frequent episodes of hypoglycemia. CONCLUSIONS: Bariatric surgery in morbidly obese T1DM patients is an effective method for weight loss, leading to a remarkable improvement in insulin requirements. Larger prospective studies are still needed to confirm these findings, assess long-term effects of BS and better delineate its risk-to-benefit ratio in this growing population of morbidly obese patients with T1DM.


Assuntos
Cirurgia Bariátrica , Diabetes Mellitus Tipo 1/complicações , Obesidade Mórbida/cirurgia , Adulto , Cirurgia Bariátrica/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/complicações , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento , Redução de Peso
10.
Am J Physiol Endocrinol Metab ; 307(8): E644-52, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-25117408

RESUMO

The hepatoportal area is an important glucohomeostatic metabolic sensor, sensing hypoglycemia, hyperglycemia, and hormones such as glucagon-like peptide-1 (GLP-1). We have reported previously that activation of hepatoportal sensors by intraportal infusion of glucose and GLP-1 or by subcutaneous administration of GLP-1 receptor activator exenatide and of intraportal glucose improved glycemia independent of corresponding changes in pancreatic hormones. It is not clear whether this effect is mediated via the portal vein (PV) or by direct action on the liver itself. To test whether receptors in the PV mediate exenatide's beneficial effect on glucose tolerance, we performed 1) paired oral glucose tolerance tests (OGTT) with and without exenatide and 2) intravenous glucose tolerance tests before and after PV denervation in canines. Denervation of the portal vein affected oral glucose tolerance; post-denervation (POST-DEN) OGTT glucose and insulin AUC were 50% higher than before denervation (P = 0.01). However, portal denervation did not impair exenatide's effect to improve oral glucose tolerance (exenatide effect: 48 ± 12 mmol·l⁻¹·min before vs. 64 ± 26 mmol·l⁻¹·min after, P = 0.67). There were no changes in insulin sensitivity or secretion during IVGTTs. Portal vein sensing might play a role in controlling oral glucose tolerance during physiological conditions but not in pharmacological activation of GLP-1 receptors by exenatide.


Assuntos
Intolerância à Glucose/tratamento farmacológico , Intolerância à Glucose/fisiopatologia , Hiperglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Peptídeos/uso terapêutico , Veia Porta/fisiopatologia , Receptores de Glucagon/agonistas , Peçonhas/uso terapêutico , Animais , Biomarcadores/metabolismo , Glicemia/análise , Cruzamentos Genéticos , Denervação , Exenatida , Receptor do Peptídeo Semelhante ao Glucagon 1 , Técnica Clamp de Glucose , Intolerância à Glucose/sangue , Intolerância à Glucose/metabolismo , Teste de Tolerância a Glucose , Hiperglicemia/etiologia , Hiperinsulinismo/etiologia , Hiperinsulinismo/prevenção & controle , Hipoglicemiantes/administração & dosagem , Injeções Subcutâneas , Insulina/sangue , Insulina/metabolismo , Resistência à Insulina , Secreção de Insulina , Ilhotas Pancreáticas/efeitos dos fármacos , Ilhotas Pancreáticas/metabolismo , Masculino , Peptídeos/administração & dosagem , Veia Porta/efeitos dos fármacos , Veia Porta/enzimologia , Veia Porta/cirurgia , Receptores de Glucagon/metabolismo , Tirosina 3-Mono-Oxigenase/metabolismo , Peçonhas/administração & dosagem
12.
Surg Endosc ; 28(6): 1902-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24442684

RESUMO

BACKGROUND: In recent years, single-port laparoscopy (SPL) has become an attractive approach for performing surgical procedures. The pitfalls of this approach are technical and financial. Financial concerns are due to the increased cost of dedicated devices and prolonged operating room time. Our aim was to calculate the cost of SPL using a reusable port and instruments in order to evaluate the cost difference between this approach to SPL using the available disposable ports and standard laparoscopy. METHODS: We performed 22 laparoscopic procedures via the SPL approach using a reusable single-port access system and reusable laparoscopic instruments. These included 17 cholecystectomies and five other procedures. Operative time, postoperative length of stay (LOS) and complications were prospectively recorded and were compared with similar data from our SPL database. Student's t test was used for statistical analysis. RESULTS: SPL was successfully performed in all cases. Mean operative time for cholecystectomy was 72 min (range 40-116). Postoperative LOS was not changed from our standard protocols and was 1.1 days for cholecystectomy. The postoperative course was within normal limits for all patients and perioperative morbidity was recorded. Both operative time and length of hospital stay were shorter for the 17 patients who underwent cholecystectomy using a reusable port than for the matched previous 17 SPL cholecystectomies we performed (p < 0.001). Prices of disposable SPL instruments and multiport access devices as well as extraction bags from different manufacturers were used to calculate the cost difference. Operating with a reusable port ended up with an average cost savings of US$388 compared with using disposable ports, and US$240 compared with standard laparoscopy. CONCLUSION: Single-port laparoscopic surgery is a technically challenging and expensive surgical approach. Financial concerns among others have been advocated against this approach; however, we demonstrate herein that using a reusable port and instruments reduces operative time and overall operative costs, even beyond the cost of standard laparoscopy.


Assuntos
Reutilização de Equipamento/economia , Laparoscopia/instrumentação , Duração da Cirurgia , Idoso , Colecistectomia/instrumentação , Colecistectomia/métodos , Colecistectomia Laparoscópica/instrumentação , Colectomia/instrumentação , Análise Custo-Benefício , Desenho de Equipamento , Feminino , Cálculos Biliares/cirurgia , Gastrectomia/instrumentação , Gastrectomia/métodos , Humanos , Tempo de Internação/economia , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Esplenectomia/instrumentação
13.
Surg Innov ; 21(5): 464-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24368399

RESUMO

BACKGROUND: Laparoendoscopic single-site sleeve gastrectomy is gaining acceptance. However, totally natural orifice translumenal endoscopic surgery (NOTES) in morbidly obese patients is still controversial due to safety and technical issues. To this end, we have developed a technique for sleeve gastrectomy in which the surgical field view is achieved through transgastric approach and the operating channel will eventually be through the vagina to form a dual lumen totally NOTES procedure for sleeve gastrectomy. As a step toward this approach, we performed a single abdominal incision in order to simulate the transvaginal route. This study is another step toward combined transvaginal and transgastric totally NOTES sleeve gastrectomy. METHODS AND PROCEDURES: A combined NOTES and single trocar sleeve gastrectomy was performed on 8 porcine animal models. The endoscope was inserted through the gastric wall and served as the vision source for the procedure. A second endoscope was inserted via the transabdominal trocar together with the surgical instruments. RESULTS: Sleeve gastrectomy was performed on 8 porcine models. The operative time for the first procedure was 5 hours, but after determining the technique, the time was reduced by half. CONCLUSION: Combined NOTES and single trocar sleeve gastrectomy is feasible in a porcine model. We achieved an excellent view of the surgical field through the transgastric approach. We believe that in the near future, combining the transgastric visualization of the surgical field together with a transvaginal approach may enable performing a total NOTES sleeve gastrectomy procedure. This hypothesis will be studied in further animal experiments before implementation in humans.


Assuntos
Gastrectomia/métodos , Laparoscopia/métodos , Cirurgia Endoscópica por Orifício Natural/métodos , Animais , Estômago/cirurgia , Suínos
14.
Harefuah ; 153(1): 15-6, 65, 2014 Jan.
Artigo em Hebraico | MEDLINE | ID: mdl-24605400

RESUMO

Single Incision Laparoscopic Surgery (SILS) is gaining popularity as a modality in surgery which reduces the number and size of skin incisions. General surgeons and urologists were the first to implement this technique, however, recently gynecologists have also started performing SILS procedures. We present the case of a 70 year old female who underwent a combined SILS procedure which included cholecystectomy, bilateral oophorectomy and omentectomy. The procedure lasted 100 minutes and the patient was discharged home the day after the operation. No operative or post-operative complications were noted. In this case report we present the technical details and demonstrate the collaboration between different disciplines which enables performing this complex and demanding procedure.


Assuntos
Colecistectomia/métodos , Laparoscopia/métodos , Omento/cirurgia , Ovariectomia/métodos , Salpingectomia/métodos , Idoso , Comportamento Cooperativo , Feminino , Humanos , Omento/patologia , Duração da Cirurgia , Resultado do Tratamento
16.
Isr Med Assoc J ; 15(5): 210-5, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23841239

RESUMO

BACKGROUND: Renal artery injuries are rarely encountered in victims of blunt trauma. However, the rate of early diagnosis of such injuries is increasing due to increased awareness and the liberal use of contrast-enhanced CT. Sporadic case reports have shown the feasibility of endovascular management of blunt renal artery injury. However, no prospective trials or long-term follow-up studies have been reported. OBJECTIVES: To present our experience with endovascular management of blunt renal artery injury, and review the literature. METHODS: We conducted a retrospective study of 18 months at a level 1 trauma center. Search of our electronic database and trauma registry identified three patients with renal artery injury from blunt trauma who were successfully treated endovascularly. Data recorded included the mechanism of injury, time from injury and admission to revascularization, type of endovascular therapy, clinical and imaging outcome, and complications. RESULTS: Mean time from injury to endovascular revascularization was 193 minutes and mean time from admission to revascularization 154 minutes. Stent-assisted angioplasty was used in two cases, while angioplasty alone was performed in a 4 year old boy. A good immediate angiographic result was achieved in all patients. At a mean follow-up of 13 months the treated renal artery was patent in all patients on duplex ultrasound. The mean percentage renal perfusion of the treated kidney at last follow-up was 36% on DTPA renal scan. No early or late complications were encountered. CONCLUSIONS: Endovascular management for blunt renal artery dissection is safe and feasible if an early diagnosis is made. This approach may be expected to replace surgical revascularization in most cases.


Assuntos
Angioplastia/métodos , Procedimentos Endovasculares/métodos , Artéria Renal/cirurgia , Ferimentos não Penetrantes/cirurgia , Pré-Escolar , Diagnóstico Precoce , Estudos de Viabilidade , Seguimentos , Humanos , Masculino , Ácido Pentético , Artéria Renal/patologia , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento , Ferimentos não Penetrantes/patologia , Adulto Jovem
17.
Minim Invasive Ther Allied Technol ; 22(5): 288-90, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23374113

RESUMO

AIM: The iMESH Tacker™ (IMT) device is a device which simplifies laproscopic hernia repair by enabling an articulation of the device tip. The study compares the strength of mesh fixation between the IMT and another commercial tack (ACT) device - Absorbatack™ (Covidien, Corp, Mansfield, MA, USA). MATERIAL AND METHODS: Strips of mesh were installed on the abodminal wall of three pigs. Half of the meshes were fixated by IMT and half by ACT. Euthanasia was done immediately to the first pig, after14 days to the second and after 27 days to the third pig. The mesh strips were pulled while fixation force was measured. Statistical analysis was done using the two tailed t-test. All mesh strips were found to be fixated. Through detachment force test, the average force in the first pig was 17.1N ± 1.9 and 16.5N ± 8.3 (IMT and ACT respectively, n/s). The average force in the second pig was 18.8N ± 7.3 and 8.4N ± 4.1 (IMT and ACT respectively, p < 0.05). The average force in the third pig was 16.3N ± 5.3 and 10.9N ± 5.9 (IMT and ACT respectively, p < 0.05). CONCLUSION: The use of IMT is both feasible and easy to learn. The study showed that IMT creates average fixation force which is higher than ACT.


Assuntos
Herniorrafia/métodos , Laparoscopia/métodos , Dispositivos de Fixação Cirúrgica , Telas Cirúrgicas , Parede Abdominal , Animais , Desenho de Equipamento , Estudos de Viabilidade , Herniorrafia/instrumentação , Laparoscopia/instrumentação , Suínos
18.
J Gastrointest Surg ; 27(5): 878-886, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36720757

RESUMO

BACKGROUND: Peroral endoscopic myotomy (POEM) is rapidly becoming the procedure of choice for treating esophageal achalasia. In most centers, contrast-enhanced swallow studies (CESS) are routinely performed postoperatively to confirm mucosal integrity. The aim of this study was to determine the necessity of performing these studies routinely after POEM. METHODS: A retrospective review of a prospectively maintained database of patients who underwent POEM between December 2012 and November 2020 was performed. All patients underwent a CESS on the first postoperative day. Medical records including vital signs, complete blood count, and POD-1 CESS were evaluated. RESULTS: One hundred thirty-four consecutive patients were included in the study. Sixty-nine (51.49%) CESS showed abnormal findings; while most findings did not change the postoperative course, five (7.2%) demonstrated tunnel leaks, which did alter the overall management. Screening patients for fever, tachycardia, or leukocytosis on POD-1 had a 100% sensitivity and a 62% specificity for finding a clinically significant complication on CESS. CONCLUSIONS: The study findings suggest that performing routine contrast-enhanced swallow studies on all patients is not necessary following POEM, as leaks can be screened for by clinical or laboratory abnormalities. Herein, we propose an algorithm based on objective measurable findings for the selection of patients who should undergo CESS.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Acalasia Esofágica , Humanos , Acalasia Esofágica/cirurgia , Esfíncter Esofágico Inferior/cirurgia , Esofagoscopia , Cirurgia Endoscópica por Orifício Natural/métodos , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
19.
Surg Endosc ; 26(3): 681-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21993936

RESUMO

BACKGROUND: Laparoscopic Heller esophagomyotomy is the standard of care for achalasia treatment. This procedure, although effective, must be performed with the patient under general anesthesia and is associated with several serious potential complications. The authors aimed to develop a method of performing transesophageal endoscopic esophagomyotomy (TEEM) that would obviate the need for both general anesthesia and external incisions while offering lower intra- and postoperative complications. METHODS: The TEEM procedure was performed on eight pigs. For six of the pigs, the procedure aimed at survival. A mid-esophageal mucosal incision was performed using an endoscope, and a submucosal plane was developed. The lower esophageal sphincter (LES) muscle fibers were clearly visualized and divided. The mucosal incision was closed using fibrin sealant. After 2 weeks of survival, a gastrografin swallow study and necropsy were performed. RESULTS: The TEEM procedure was performed successfully in all eight porcine models. The myotomy included the LES fibers and extended 4 to 6 cm proximally to the esophagus. The proximal gastric muscle was divided up to 1 to 2 cm. No injuries to the abdominal or mediastinal structures occurred. One pig died on postoperative day 1 due to an unrecognized pneumothorax. Two pigs had ischemic ulcers at the myotomy site. The last three pigs had an uneventful recovery. The mucosal incision site healed completely in all the survived pigs, and except for the pig with mediastinal sepsis, all ate heartily and gained weight as expected. CONCLUSION: The TEEM procedure is technically feasible. Due to the morbidity encountered in the first three pigs, the reported technique was modified to include a slimmer endoscope, a shorter tunnel, and a partial-thickness myotomy. These changes together with an understanding of the pitfalls involved in this procedure led to successful results for the next three pigs. Nevertheless, the authors believe that TEEM is not yet ready for prime time. Perfection of the technique and development of dedicated instruments are mandatory before safe translation of this method to human patients.


Assuntos
Acalasia Esofágica/cirurgia , Esfíncter Esofágico Inferior/cirurgia , Esofagectomia/métodos , Esofagoscopia/métodos , Complicações Pós-Operatórias/prevenção & controle , Animais , Sus scrofa , Cicatrização/fisiologia
20.
JSLS ; 16(4): 588-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23484569

RESUMO

BACKGROUND AND OBJECTIVES: Laparoscopic partial nephrectomy (LPN) is a challenging surgery that requires precise tissue cutting and meticulous hemostasis under warm ischemia conditions. In this study, we tested the feasibility of performing LPN using CO2 laser energy transmitted through a specialized flexible mirror optical fiber. METHODS: General anesthesia and pneumoperitoneum were induced in 7 farm pigs. Various portions of a kidney, either a pole or a midportion of the kidney, were removed using a novel flexible fiber to transmit CO2 laser energy set at a power of 45W and energy per pulse of 100mJ. The collecting system was approximated with a suture or 2, but no hemostatic measures were taken besides applying a few pulses of the laser to bleeding points. The pigs were sacrificed 3 wk later. RESULTS: Average renal mass removed was 18% of the total kidney weight. All pigs tolerated surgery well. Sharp renal cutting was accomplished in a single continuous incision, with minimal tissue charring and minimal blood loss (<10cc) in all animals. Necropsy revealed no peritoneal or retroperitoneal abnormalities. Histologic examination of the cut surface showed a thin sector of up to 100 m of coagulation necrosis. CONCLUSIONS: We report on the first LPN done using a CO2 laser transmitted through a flexible fiber in an animal model. This novel application of the CO2 laser produced excellent parenchymal incision and hemostasis along with minimal damage to adjacent renal tissue, thus, potentially shortening ischemia time and kidney function loss. Further studies comparing this laser to standard technique are necessary to verify its usefulness for partial nephrectomy.


Assuntos
Nefropatias/cirurgia , Laparoscopia/métodos , Terapia a Laser/instrumentação , Lasers de Gás/uso terapêutico , Nefrectomia/métodos , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Maleabilidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA