Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 196(6): 1374-80, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606302

RESUMO

OBJECTIVE: The purpose of this study is to evaluate the effect of arterial input selection on perfusion CT parameters of head and neck tumors. MATERIALS AND METHODS: Perfusion calculations were done for 50 cases using deconvolution-based software. Peak enhancement values of the ipsilateral internal carotid artery (ICA) and external carotid artery (ECA) were recorded. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product were calculated using ipsilateral ECA, ipsilateral ICA, and contralateral ICA as input arteries. Values were compared using Wilcoxon's matched pair test and Pearson's correlation coefficients (r). RESULTS: A highly significant correlation was observed between peak enhancement values of the ICA and ECA (r = 0.97; p < 0.0001). A high correlation was observed between perfusion calculations obtained using ipsilateral ICA and ECA (BF, r = 0.98; BV, r = 0.92; MTT, r = 0.91; and permeability surface area product, r = 0.89), ipsilateral and contralateral ICA (BF, r = 0.97; BV, r = 0.95; MTT, r = 0.93; and permeability surface area product, r = 0.89), as well as left and right ICA (BF, r = 0.97; BV, r = 0.95; MTT, r = 0.94; and permeability surface area product, r = 0.88). All correlations were statistically significant (p < 0.0001). No significant differences were observed between perfusion calculations obtained using ipsilateral ICA versus ECA, ipsilateral versus contralateral ICA, or left versus right ICA (p > 0.05). CONCLUSION: Arterial input selection has no significant effect on perfusion CT calculation of head and neck cancer. For standardization and simplification of postprocessing, we recommend the use of the ICA instead of the ECA as the arterial input because of its better visualization, perpendicular course, and larger caliber, all of which decrease partial volume effects.


Assuntos
Artéria Carótida Externa/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Neoplasias de Cabeça e Pescoço/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA