Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Neth Heart J ; 32(4): 160-166, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38015347

RESUMO

BACKGROUND: Untreated atrial fibrillation (AF) often results in increased morbidity and mortality. Opportunistic AF screening in persons aged ≥ 65 years is recommended to identify patients with AF in order to prevent AF-related complications. OBJECTIVE: The aim of this study was to assess the feasibility of screening persons for AF with the Kardia mobile electrocardiogram device (MED) and to determine the percentage of newly detected AF cases by selective population screening in the Netherlands. METHODS: Persons aged ≥ 65 years, without a medical history of AF, in nursing homes, at public events or visiting the general practitioner (GP) were approached to participate. A Kardia MED smartphone ECG (sECG) was recorded and the CHA2DS2-VASc score was calculated. An automated AF algorithm classified the sECGs as 'sinus rhythm', 'AF' or 'unclassified'. In the case of AF, participants were referred to their GP. All sECGs were assessed by blinded experts. RESULTS: A total of 2168 participants were screened for AF. According to the expert's interpretation, 2.5% had newly detected AF, of whom 76.4% never experienced palpitations and 89.1% had a CHA2DS2-VASc score ≥ 2. The algorithm result was unclassified in 12.2% of cases, of which 95.5% were interpretable by experts. With expert opinion as the gold standard and excluding unclassified sECGs, the Kardia MED's negative and positive predictive value for detecting AF was 99.8% and 60.0%, respectively. CONCLUSION: Screening for AF using the Kardia MED is feasible and results in 2.5% newly detected AF cases. Expert interpretation of algorithm outcomes AF and unclassified is recommended.

2.
Circulation ; 145(12): 906-915, 2022 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-35135308

RESUMO

BACKGROUND: We aimed to assess the prevalence of ischemic brain lesions detected by magnetic resonance imaging and their association with cognitive function 3 months after first-time ablation using continuous oral anticoagulation in patients with paroxysmal atrial fibrillation (AF). METHODS: We performed a prespecified analysis of the AXAFA-AFNET 5 trial (Anticoagulation Using the Direct Factor Xa Inhibitor Apixaban During Atrial Fibrillation Catheter Ablation: Comparison to Vitamin K Antagonist Therapy), which randomized 674 patients with AF 1:1 to uninterrupted apixaban or vitamin K antagonist therapy before first-time ablation. Brain magnetic resonance imaging using fluid-attenuated inversion recovery and high-resolution diffusion-weighted imaging was obtained within 3 to 48 hours after AF ablation in all eligible patients enrolled in 25 study centers in Europe and the United States. Patients underwent cognitive assessment 3 to 6 weeks before ablation and 3 months after ablation using the Montreal Cognitive Assessment (MoCA). RESULTS: In 84 (26.1%) of 321 patients with analyzable magnetic resonance imaging, high-resolution diffusion-weighted imaging detected at least 1 acute brain lesion, including 44 (27.2%) patients treated with apixaban and 40 (24.8%) patients treated with vitamin K antagonist (P=0.675). Median MoCA score was similar in patients with or without acute brain lesions at 3 months after ablation (28 [interquartile range (IQR), 26-29] versus 28 [IQR, 26-29]; P=0.948). Cerebral chronic white matter damage (defined as Wahlund score ≥4 points) detected by fluid-attenuated inversion recovery was present in 130 (40.5%) patients and associated with lower median MoCA scores before ablation (27 [IQR, 24-28] versus 27 [IQR, 25-29]; P=0.026) and 3 months after ablation (27 [IQR, 25-29] versus 28 [IQR, 26-29]; P=0.011). This association was no longer significant when adjusted for age and sex. Age was associated with lower MoCA scores before ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]) and 3 months after ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]). CONCLUSIONS: Chronic white matter damage as well as acute ischemic lesions detected by brain magnetic resonance imaging were found frequently after first-time ablation for paroxysmal AF using uninterrupted oral anticoagulation. Acute ischemic brain lesions detected by high-resolution diffusion-weighted imaging were not associated with cognitive function at 3 months after ablation. Lower MoCA scores before and after ablation were associated only with older age, highlighting the safety of AF ablation on uninterrupted oral anticoagulation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02227550.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Encéfalo/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Cognição , Humanos , Imageamento por Ressonância Magnética , Resultado do Tratamento , Vitamina K
3.
N Engl J Med ; 383(14): 1305-1316, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32865375

RESUMO

BACKGROUND: Despite improvements in the management of atrial fibrillation, patients with this condition remain at increased risk for cardiovascular complications. It is unclear whether early rhythm-control therapy can reduce this risk. METHODS: In this international, investigator-initiated, parallel-group, open, blinded-outcome-assessment trial, we randomly assigned patients who had early atrial fibrillation (diagnosed ≤1 year before enrollment) and cardiovascular conditions to receive either early rhythm control or usual care. Early rhythm control included treatment with antiarrhythmic drugs or atrial fibrillation ablation after randomization. Usual care limited rhythm control to the management of atrial fibrillation-related symptoms. The first primary outcome was a composite of death from cardiovascular causes, stroke, or hospitalization with worsening of heart failure or acute coronary syndrome; the second primary outcome was the number of nights spent in the hospital per year. The primary safety outcome was a composite of death, stroke, or serious adverse events related to rhythm-control therapy. Secondary outcomes, including symptoms and left ventricular function, were also evaluated. RESULTS: In 135 centers, 2789 patients with early atrial fibrillation (median time since diagnosis, 36 days) underwent randomization. The trial was stopped for efficacy at the third interim analysis after a median of 5.1 years of follow-up per patient. A first-primary-outcome event occurred in 249 of the patients assigned to early rhythm control (3.9 per 100 person-years) and in 316 patients assigned to usual care (5.0 per 100 person-years) (hazard ratio, 0.79; 96% confidence interval, 0.66 to 0.94; P = 0.005). The mean (±SD) number of nights spent in the hospital did not differ significantly between the groups (5.8±21.9 and 5.1±15.5 days per year, respectively; P = 0.23). The percentage of patients with a primary safety outcome event did not differ significantly between the groups; serious adverse events related to rhythm-control therapy occurred in 4.9% of the patients assigned to early rhythm control and 1.4% of the patients assigned to usual care. Symptoms and left ventricular function at 2 years did not differ significantly between the groups. CONCLUSIONS: Early rhythm-control therapy was associated with a lower risk of adverse cardiovascular outcomes than usual care among patients with early atrial fibrillation and cardiovascular conditions. (Funded by the German Ministry of Education and Research and others; EAST-AFNET 4 ISRCTN number, ISRCTN04708680; ClinicalTrials.gov number, NCT01288352; EudraCT number, 2010-021258-20.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Doenças Cardiovasculares/prevenção & controle , Ablação por Cateter , Síndrome Coronariana Aguda/epidemiologia , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/complicações , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Tempo de Internação , Masculino , Risco , Prevenção Secundária , Método Simples-Cego , Função Ventricular Esquerda/efeitos dos fármacos
4.
Eur Heart J ; 43(40): 4161-4173, 2022 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-35979843

RESUMO

AIMS: Permanent transseptal left bundle branch area pacing (LBBAP) is a promising new pacing method for both bradyarrhythmia and heart failure indications. However, data regarding safety, feasibility and capture type are limited to relatively small, usually single centre studies. In this large multicentre international collaboration, outcomes of LBBAP were evaluated. METHODS AND RESULTS: This is a registry-based observational study that included patients in whom LBBAP device implantation was attempted at 14 European centres, for any indication. The study comprised 2533 patients (mean age 73.9 years, female 57.6%, heart failure 27.5%). LBBAP lead implantation success rate for bradyarrhythmia and heart failure indications was 92.4% and 82.2%, respectively. The learning curve was steepest for the initial 110 cases and plateaued after 250 cases. Independent predictors of LBBAP lead implantation failure were heart failure, broad baseline QRS and left ventricular end-diastolic diameter. The predominant LBBAP capture type was left bundle fascicular capture (69.5%), followed by left ventricular septal capture (21.5%) and proximal left bundle branch capture (9%). Capture threshold (0.77 V) and sensing (10.6 mV) were stable during mean follow-up of 6.4 months. The complication rate was 11.7%. Complications specific to the ventricular transseptal route of the pacing lead occurred in 209 patients (8.3%). CONCLUSIONS: LBBAP is feasible as a primary pacing technique for both bradyarrhythmia and heart failure indications. Success rate in heart failure patients and safety need to be improved. For wider use of LBBAP, randomized trials are necessary to assess clinical outcomes.


Assuntos
Fascículo Atrioventricular , Insuficiência Cardíaca , Humanos , Feminino , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Bradicardia/terapia , Bradicardia/etiologia , Eletrocardiografia/métodos , Resultado do Tratamento
5.
Circulation ; 144(11): 845-858, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34328366

RESUMO

BACKGROUND: Even on optimal therapy, many patients with heart failure and atrial fibrillation experience cardiovascular complications. Additional treatments are needed to reduce these events, especially in patients with heart failure and preserved left ventricular ejection fraction. METHODS: This prespecified subanalysis of the randomized EAST-AFNET4 trial (Early Treatment of Atrial Fibrillation for Stroke Prevention Trial) assessed the effect of systematic, early rhythm control therapy (ERC; using antiarrhythmic drugs or catheter ablation) compared with usual care (allowing rhythm control therapy to improve symptoms) on the 2 primary outcomes of the trial and on selected secondary outcomes in patients with heart failure, defined as heart failure symptoms New York Heart Association II to III or left ventricular ejection fraction [LVEF] <50%. RESULTS: This analysis included 798 patients (300 [37.6%] female, median age 71.0 [64.0, 76.0] years, 785 with known LVEF). The majority of patients (n=442) had heart failure and preserved LVEF (LVEF≥50%; mean LVEF 61±6.3%), the others had heart failure with midrange ejection fraction (n=211; LVEF 40%-49%; mean LVEF 44 ± 2.9%) or heart failure with reduced ejection fraction (n=132; LVEF<40%; mean LVEF 31±5.5%). Over the 5.1-year median follow-up, the composite primary outcome of cardiovascular death, stroke, or hospitalization for worsening of heart failure or for acute coronary syndrome occurred less often in patients randomly assigned to ERC (94/396; 5.7 per 100 patient-years) compared with patients randomly assigned to usual care (130/402; 7.9 per 100 patient-years; hazard ratio, 0.74 [0.56-0.97]; P=0.03), not altered by heart failure status (interaction P value=0.63). The primary safety outcome (death, stroke, or serious adverse events related to rhythm control therapy) occurred in 71 of 396 (17.9%) patients with heart failure randomly assigned to ERC and in 87 of 402 (21.6%) patients with heart failure randomly assigned to usual care (hazard ratio, 0.85 [0.62-1.17]; P=0.33). LVEF improved in both groups (LVEF change at 2 years: ERC 5.3±11.6%, usual care 4.9±11.6%, P=0.43). ERC also improved the composite outcome of death or hospitalization for worsening of heart failure. CONCLUSIONS: Rhythm control therapy conveys clinical benefit when initiated within 1 year of diagnosing atrial fibrillation in patients with signs or symptoms of heart failure. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01288352. URL: http://www.controlled-trials.com; Unique identifier: ISRCTN04708680. URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2010-021258-20.


Assuntos
Fibrilação Atrial/terapia , Insuficiência Cardíaca/terapia , Prevenção Secundária , Disfunção Ventricular Esquerda/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Acidente Vascular Cerebral/terapia , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia
6.
Am Heart J ; 250: 45-56, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35537503

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) provides an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). In patients with a long-term or permanent contraindication for OAC randomized controlled trial (RCT) data is lacking. STUDY OBJECTIVES: To assess the efficacy and safety of LAAO in AF patients who are ineligible to use OAC. The co-primary efficacy endpoint is (1) time to first occurrence of stroke (ischemic, hemorrhagic, or undetermined) and (2) time to first occurrence of the composite of stroke, transient ischemic attack (TIA), and systemic embolism (SE). The primary safety endpoint is the 30-day rate of peri-procedural complications. STUDY DESIGN: This is a multicenter, investigator-initiated, open-label, blinded endpoint (PROBE), superiority-driven RCT. Patients with AF, a CHA2DS2-VASc score ≥2 for men and ≥3 for women and a long-term or permanent contraindication for OAC will be randomized in a 2:1 fashion to the device- or control arm. Patients in the device arm will undergo percutaneous LAAO and will receive post-procedural dual antiplatelet therapy (DAPT) per protocol, while those in the control arm will continue their current treatment consisting of no antithrombotic therapy or (D)APT as deemed appropriate by the primary responsible physician. In this endpoint-driven trial design, assuming a 50% lower stroke risk of LAAO compared to conservative treatment, 609 patients will be followed for a minimum of 1 and a maximum of 5 years. Cost-effectiveness and budget impact analyses will be performed to allow decision-making on reimbursement of LAAO for the target population in the Netherlands. SUMMARY: The COMPARE LAAO trial will investigate the clinical superiority in preventing thromboembolic events and cost-effectiveness of LAAO in AF patients with a high thromboembolic risk and a contraindication for OAC use. NCT TRIAL NUMBER: NCT04676880.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Anticoagulantes , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Masculino , Padrão de Cuidado , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35040534

RESUMO

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Paralisia/etiologia , Nervo Frênico , Veias Pulmonares/cirurgia , Resultado do Tratamento
8.
Europace ; 24(3): 384-389, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34414430

RESUMO

AIMS: We hypothesize that in patients with paroxysmal atrial fibrillation (AF), verapamil is associated with lower AF progression compared to beta blockers or no rate control. METHODS AND RESULTS: In this pre-specified post hoc analysis of the RACE 4 randomized trial, the effect of rate control medication on AF progression in paroxysmal AF was analysed. Patients using Vaughan-Williams Class I or III antiarrhythmic drugs were excluded. The primary outcome was a composite of first electrical cardioversion (ECV), chemical cardioversion (CCV), or atrial ablation. Event rates are displayed using Kaplan-Meier curves and multivariable Cox regression analyses are used to adjust for baseline differences. Out of 666 patients with paroxysmal AF, 47 used verapamil, 383 used beta blockers, and 236 did not use rate control drugs. The verapamil group was significantly younger than the beta blocker group and contained more men than the no rate control group. Over a mean follow-up of 37 months, the primary outcome occurred in 17% in the verapamil group, 33% in the beta blocker group, and 33% in the no rate control group (P = 0.038). After adjusting for baseline characteristics, patients using verapamil have a significantly lower chance of receiving ECV, CCV, or atrial ablation compared to patients using beta blockers [hazard ratio (HR) 0.40, 95% confidence interval (CI) 0.19-0.83] and no rate control (HR 0.64, 95% CI 0.44-0.93). CONCLUSION: In patients with newly diagnosed paroxysmal AF, verapamil was associated with less AF progression, as compared to beta blockers and no rate control.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Humanos , Masculino , Resultado do Tratamento
9.
Europace ; 24(4): 552-564, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34473249

RESUMO

AIMS: Treatment patterns were compared between randomized groups in EAST-AFNET 4 to assess whether differences in anticoagulation, therapy of concomitant diseases, or intensity of care can explain the clinical benefit achieved with early rhythm control in EAST-AFNET 4. METHODS AND RESULTS: Cardiovascular treatment patterns and number of visits were compared between randomized groups in EAST-AFNET 4. Oral anticoagulation was used in >90% of patients during follow-up without differences between randomized groups. There were no differences in treatment of concomitant conditions between groups. The type of rhythm control varied by country and centre. Over time, antiarrhythmic drugs were given to 1171/1395 (84%) patients in early therapy, and to 202/1394 (14%) in usual care. Atrial fibrillation (AF) ablation was performed in 340/1395 (24%) patients randomized to early therapy, and in 168/1394 (12%) patients randomized to usual care. 97% of rhythm control therapies were within class I and class III recommendations of AF guidelines. Patients randomized to early therapy transmitted 297 166 telemetric electrocardiograms (ECGs) to a core lab. In total, 97 978 abnormal ECGs were sent to study sites. The resulting difference between study visits was low (0.06 visits/patient/year), with slightly more visits in early therapy (usual care 0.39 visits/patient/year; early rhythm control 0.45 visits/patient/year, P < 0.001), mainly due to visits for symptomatic AF recurrences or recurrent AF on telemetric ECGs. CONCLUSION: The clinical benefit of early, systematic rhythm control therapy was achieved using variable treatment patterns of antiarrhythmic drugs and AF ablation, applied within guideline recommendations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Prevenção Secundária , Acidente Vascular Cerebral/terapia
10.
Pacing Clin Electrophysiol ; 45(1): 132-140, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34875112

RESUMO

AIMS: Goal of Transvenous Lead Extraction (TLE) is complete removal of all targeted leads, without complications. Despite counter traction manoeuvres, efficacy rates are often hampered by broken right ventricle lead (RV-lead) tips. Mechanically powered lead extraction (Evolution sheath) is effective, however safety of dissection up to the lead tip is unclear. Therefore, we examined the feasibility and safety of RV-lead extraction requiring dissection up to the myocardium. METHODS AND RESULTS: From 2009 to 2018, all TLE in the Isala Heart Centre (Zwolle, The Netherlands) requiring the hand-powered mechanical Evolution system to extract RV-leads (n = 185) were examined from a prospective registry. We assessed 4 groups: TLE with the first generation Evolution (n = 43) with (A1,n = 18) and without (A2,n = 25) adhesions up to the myocardium and TLE with the Novel R/L type (n = 142) of sheath with (B1, n = 59) and without (B2, n = 83) adhesions up to the myocardium. Complete success rate in Group B was significantly higher than group A (96.5 vs 76.7%, p = 0.0354). When comparing the patients with adhesions up to the myocardium, total complete success is higher in the R/L group (61.1% vs 90.5%, p = 0.0067). There were no deaths. Overall major complication rates were low (2/185; 1.1%) and there was no statistically significant difference in major and minor complications between the two groups. CONCLUSION: Extraction strategy with the bidirectional Evolution R/L sheath for right ventricular leads with adhesions up to the myocardium is safe and feasible.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Marca-Passo Artificial , Idoso , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Países Baixos , Falha de Prótese , Sistema de Registros
11.
Eur J Clin Invest ; 51(4): e13497, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33482016

RESUMO

AIM: Integration of endomyocardial biopsy (EMB) in the diagnostic workup of cardiac sarcoidosis (CS) is under-recognized in current clinical practice, since capturing focal granulomas is challenging. Our aim was to describe our experience with electro-anatomic mapping (EAM)-guided EMB and provide a comprehensive review of the literature. METHODS AND RESULTS: Five patients (age 49.4 ± 11.4) with suspected CS underwent EAM-guided EMB in Isala Heart Center (Zwolle, the Netherlands) between 2017 and 2019. In all patients, a 3D bipolar voltage map (<0.5-1.5 mV) and unipolar voltage map (LV < 8.3 mV, RV < 5.5 mV) was created using a high-density mapping catheter. The bioptome was connected to the mapping system to guide targeted EMB. Biopsy samples (2-9 samples) were taken from both LV and RV sites, guided by EAM and areas with abnormal electrograms, without complications. CS diagnosis was based on EMB in 2/5 patients. A granuloma was captured in one patient at the LV basal septum with normal bipolar and abnormal unipolar voltage. All patients with delayed enhancement on cardiac magnetic resonance, revealed fibrosis in the biopsy sample. In one patient with suspected isolated cardiac sarcoidosis, diagnosis could not be confirmed by histopathology analysis, while unipolar voltage mapping was abnormal and diastolic potentials were present. Literature search revealed 7 reports (18 patients) describing EAM-guided EMB in CS patients, with 100% of the EMB taken form the RV. CONCLUSION: Unipolar voltage mapping may be superior to target active inflamed tissue and should be evaluated in future research regarding EAM-guided EMB in CS.


Assuntos
Cardiomiopatias/patologia , Sarcoidose/patologia , Adulto , Biópsia , Técnicas de Imagem Cardíaca , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Biópsia Guiada por Imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sarcoidose/diagnóstico por imagem , Sarcoidose/fisiopatologia
12.
Europace ; 23(3): 464-468, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33200191

RESUMO

AIMS: We investigated the efficacy of linear multi-electrode irreversible electroporation (IRE) ablation in a porcine model. METHODS AND RESULTS: The study was performed in six pigs (weight 60-75 kg). After median sternotomy and opening of the pericardium, a pericardial cradle was formed and filled with blood. A linear seven polar 7-Fr electrode catheter with 2.5 mm electrodes and 2.5 mm inter-electrode spacing was placed in good contact with epicardial tissue. A single IRE application was delivered using 50 J at one site and 100 J at two other sites, in random sequence, using a standard monophasic defibrillator connected to all seven electrodes connected in parallel. The pericardium and thorax were closed and after 3 weeks survival animals were euthanized. A total of 82 histological sections from all 18 electroporation lesions were analysed. A total of seven 50 J and fourteen 100 J epicardial IRE applications were performed. Mean peak voltages at 50 and 100 J were 1079.2 V ± 81.1 and 1609.5 V ± 56.8, with a mean peak current of 15.4 A ± 2.3 and 20.2 A ± 1.7, respectively. Median depth of the 50 and 100 J lesions were 3.2 mm [interquartile range (IQR) 3.1-3.6] and 5.5 mm (IQR 4.6-6.6) (P < 0.001), respectively. Median lesion width of the 50 and 100 J lesions was 3.9 mm (IQR 3.7-4.8) and 5.4 mm (IQR 5.0-6.3), respectively (P < 0.001). Longitudinal sections showed continuous lesions for 100 J applications. CONCLUSION: Epicardial multi-electrode linear application of IRE pulses is effective in creating continuous deep lesions.


Assuntos
Ablação por Cateter , Eletroporação , Animais , Catéteres , Eletrodos , Pericárdio/cirurgia , Suínos
13.
Europace ; 23(12): 1931-1938, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34279627

RESUMO

AIMS: Pulmonary vein isolation (PVI) for atrial fibrillation (AF) has become increasingly safe and effective with the evolution of single-tip ablation catheters aided by contact force sensing (ST-CF) and single-shot devices such as the second-generation pulmonary vein ablation catheter (PVAC) Gold multi-electrode array. The multicentre randomized GOLD FORCE trial was conducted to evaluate non-inferiority of safety and efficacy of PVAC Gold PVI compared to ST-CF ablation for paroxysmal AF. METHODS AND RESULTS: The primary efficacy endpoint documented AF recurrence ≥30 s was assessed by time-to-first-event analysis after a 90-day blanking period using repeated 7-day Holters. Secondary endpoints include acute success and procedural characteristics. Safety endpoints included procedural complications, stroke/transient ischaemic attack (TIA), tamponade, bleeding, and access site complications. Two hundred and eight patients underwent randomization and PVI (103 assigned to PVAC Gold, 105 to ST-CF). Acute success rates were 95% and 97% for PVAC Gold and ST-CF, respectively. At 12 months, AF recurrence was observed in 46.6% of the PVAC Gold group and in 26.2% of the ST-CF group [absolute efficacy difference 20.4% (95% confidence interval, CI 7.5-33.2%), hazard ratio 2.05 (95% CI 1.28-3.29), P = 0.003]. PVAC Gold had significantly shorter procedure and ablation times. Complication rates were 5.7% and 4.9% for PVAC Gold and ST-CF, respectively (P = 0.782). CONCLUSION: In this multicentre randomized clinical trial, ablation with ST-CF and PVAC Gold ablation catheters non-inferiority for efficacy was not met. AF recurrence was significantly more frequent in the PVAC Gold group compared to single-tip contact force group. Both groups had similarly low rates of adverse events. PVAC Gold ablation had significantly shorter procedure and ablation times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 44(11): 1918-1924, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34523140

RESUMO

BACKGROUND: The subcutaneous cardioverter-defibrillator (S-ICD) continues to be preferentially used in relatively young patients, with less advanced heart disease. OBJECTIVE: We, therefore, studied the short and long-term efficacy and safety of the S-ICD in subgroups of patients, which are underreported at present. METHODS: A total of 218 patients between November 2010 and February 2019 undergoing S-ICD with a follow up of at least 6 months implantation were included in a prospective registry. Mean follow up was 38 months. RESULTS: The most common indication for S-ICD implantation was ischemic cardiomyopathy (n = 106, 49%). Complication rate needing invasive intervention was 9% (n = 21). Appropriate shock rate in patients with an S-ICD was 3.5%/year. A total of 30 inappropriate shocks (IAS) occurred in 19 patients (8.7%; 2.7%/year). The proportion of appropriate and inappropriate shock rates in patients with different cardiomyopathies shows remarkable variances. There were significant more IAS (3.6%/year vs. 1.7%/year, p = .048) in patients with non-ischemic cardiomyopathy versus patients with ischemic cardiomyopathy. Multivariate analysis identified, besides type of cardiomyopathy, atrial fibrillation (AF) as predictor for IAS. CONCLUSION: In this real-world prospective registry we analyzed S-ICD performance in the more traditional ICD patient. Patients with ischemic cardiomyopathy had significantly less inappropriate therapy compared to patients with non-ischemic cardiomyopathy and appear to be appropriate patients for this type of device.


Assuntos
Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Cardioversão Elétrica/instrumentação , Isquemia Miocárdica/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Segurança do Paciente , Sistema de Registros
15.
Pacing Clin Electrophysiol ; 44(1): 44-53, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33179782

RESUMO

BACKGROUND: Previous studies reported that hypo- and hyperthermia are associated with several atrial and ventricular electrocardiographical parameters, including corrected QT (QTc) interval. Enhanced characterization of variations in QTc interval and normothermic body temperature aids in better understanding the underlying mechanism behind drug induced QTc interval effects. The analysis' objective was to investigate associations between body temperature and electrocardiographical parameters in normothermic healthy volunteers. METHODS: Data from 3023 volunteers collected at our center were retrospectively analyzed. Subjects were considered healthy after review of collected data by a physician, including a normal tympanic body temperature (35.5-37.5°C) and in sinus rhythm. A linear multivariate model with body temperature as a continuous was performed. Another multivariate analysis was performed with only the QT subintervals as independent variables and body temperature as dependent variable. RESULTS: Mean age was 33.8 ± 17.5 years and mean body temperature was 36.6 ± 0.4°C. Body temperature was independently associated with age (standardized coefficient [SC] = -0.255, P < .001), female gender (SC = +0.209, P < .001), heart rate (SC = +0.231, P < .001), P-wave axis (SC = -0.051, P < .001), J-point elevation in lead V4 (SC = -0.121, P < .001), and QTcF duration (SC = -0.061, P = .002). In contrast, other atrial and atrioventricular (AV) nodal parameters were not independently associated with body temperature. QT subinterval analysis revealed that only QRS duration (SC = -0.121, P < .001) was independently associated with body temperature. CONCLUSION: Body temperature in normothermic healthy volunteers was associated with heart rate, P-wave axis, J-point amplitude in lead V4, and ventricular conductivity, the latter primarily through prolongation of the QRS duration.


Assuntos
Temperatura Corporal , Eletrocardiografia , Voluntários Saudáveis , Adulto , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Estudos Retrospectivos
16.
Blood Press ; 30(6): 376-385, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34647513

RESUMO

PURPOSE: Blood pressure (BP) reduction after renal sympathetic denervation (RDN) is highly variable. Renal nerve stimulation (RNS) can localize sympathetic nerves. The RNS trial aimed to investigate the medium-term BP-lowering effects of the use of RNS during RDN, and explore if RNS can check the completeness of the denervation. MATERIAL AND METHODS: Forty-four treatment-resistant hypertensive patients were included in the prospective, single-center RNS trial. The primary study endpoint was change in 24-h BP at 6- to 12-month follow-up after RDN. The secondary study endpoints were the acute procedural RNS-induced BP response before and after RDN; number of antihypertensive drugs at follow-up; and the correlation between the RNS-induced BP increase before versus after RDN (delta [Δ] RNS-induced BP). RESULTS: Before RDN, the RNS-induced systolic BP rise was 43(±21) mmHg, and decreased to 9(±12) mmHg after RDN (p < 0.001). Mean 24-h systolic/diastolic BP decreased from 147(±12)/82(±11) mmHg at baseline to 135(±11)/76(±10) mmHg (p < 0.001/<0.001) at follow-up (10 [6-12] months), with 1 antihypertensive drug less compared to baseline. The Δ RNS-induced BP and the 24-h BP decrease at follow-up were correlated for systolic (R = 0.44, p = 0.004) and diastolic (R = 0.48, p = 0.003) BP. Patients with ≤0 mmHg residual RNS-induced BP response after RDN had a significant lower mean 24-h systolic BP at follow-up compared to the patients with >0 mmHg residual RNS-induced BP response (126 ± 4 mmHg versus 135 ± 10 mmHg, p = 0.04). 83% of the patients with ≤0 mmHg residual RNS-induced BP response had normal 24-h BP at follow-up, compared to 33% in the patients with >0 mmHg residual RNS-induced BP response (p = 0.023). CONCLUSION: The use of RNS during RDN leads to clinically significant and sustained lowering of 24-h BP with fewer antihypertensive drugs at follow-up. RNS-induced BP changes were correlated with 24-h BP changes at follow-up. Moreover, patients with complete denervation had significant lower BP compared to the patients with incomplete denervation.


Assuntos
Hipertensão , Rim , Pressão Sanguínea , Humanos , Hipertensão/cirurgia , Rim/cirurgia , Estudos Prospectivos , Simpatectomia , Resultado do Tratamento
17.
Eur Heart J ; 41(30): 2836-2844, 2020 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-32112556

RESUMO

AIMS: To evaluate whether integrated care for atrial fibrillation (AF) can be safely orchestrated in primary care. METHODS AND RESULTS: The ALL-IN trial was a cluster randomized, open-label, pragmatic non-inferiority trial performed in primary care practices in the Netherlands. We randomized 26 practices: 15 to the integrated care intervention and 11 to usual care. The integrated care intervention consisted of (i) quarterly AF check-ups by trained nurses in primary care, also focusing on possibly interfering comorbidities, (ii) monitoring of anticoagulation therapy in primary care, and finally (iii) easy-access availability of consultations from cardiologists and anticoagulation clinics. The primary endpoint was all-cause mortality during 2 years of follow-up. In the intervention arm, 527 out of 941 eligible AF patients aged ≥65 years provided informed consent to undergo the intervention. These 527 patients were compared with 713 AF patients in the control arm receiving usual care. Median age was 77 (interquartile range 72-83) years. The all-cause mortality rate was 3.5 per 100 patient-years in the intervention arm vs. 6.7 per 100 patient-years in the control arm [adjusted hazard ratio (HR) 0.55; 95% confidence interval (CI) 0.37-0.82]. For non-cardiovascular mortality, the adjusted HR was 0.47 (95% CI 0.27-0.82). For other adverse events, no statistically significant differences were observed. CONCLUSION: In this cluster randomized trial, integrated care for elderly AF patients in primary care showed a 45% reduction in all-cause mortality when compared with usual care.


Assuntos
Fibrilação Atrial , Cardiologistas , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Comorbidade , Humanos , Países Baixos/epidemiologia , Atenção Primária à Saúde
18.
Eur Heart J ; 41(5): 634-641, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31544925

RESUMO

BACKGROUND: Nurse-led integrated care is expected to improve outcome of patients with atrial fibrillation compared with usual-care provided by a medical specialist. METHODS AND RESULTS: We randomized 1375 patients with atrial fibrillation (64 ± 10 years, 44% women, 57% had CHA2DS2-VASc ≥ 2) to receive nurse-led care or usual-care. Nurse-led care was provided by specialized nurses using a decision-support tool, in consultation with the cardiologist. The primary endpoint was a composite of cardiovascular death and cardiovascular hospital admissions. Of 671 nurse-led care patients, 543 (81%) received anticoagulation in full accordance with the guidelines against 559 of 683 (82%) usual-care patients. The cumulative adherence to guidelines-based recommendations was 61% under nurse-led care and 26% under usual-care. Over 37 months of follow-up, the primary endpoint occurred in 164 of 671 patients (9.7% per year) under nurse-led care and in 192 of 683 patients (11.6% per year) under usual-care [hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.69 to 1.04, P = 0.12]. There were 124 vs. 161 hospitalizations for arrhythmia events (7.0% and 9.4% per year), and 14 vs. 22 for heart failure (0.7% and 1.1% per year), respectively. Results were not consistent in a pre-specified subgroup analysis by centre experience, with a HR of 0.52 (95% CI 0.37-to 0.71) in four experienced centres and of 1.24 (95% CI 0.94-1.63) in four less experienced centres (P for interaction <0.001). CONCLUSION: Our trial failed to show that nurse-led care was superior to usual-care. The data suggest that nurse-led care by an experienced team could be clinically beneficial (ClinicalTrials.gov NCT01740037). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov (NCT01740037).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Acidente Vascular Cerebral , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Papel do Profissional de Enfermagem , Modelos de Riscos Proporcionais
19.
Europace ; 22(8): 1162-1172, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32642768

RESUMO

AIMS: Atrial fibrillation (AF) often starts as a paroxysmal self-terminating arrhythmia. Limited information is available on AF patterns and episode duration of paroxysmal AF. In paroxysmal AF patients, we longitudinally studied the temporal AF patterns, the association with clinical characteristics, and prevalence of AF progression. METHODS AND RESULTS: In this interim analysis of the Reappraisal of AF: Interaction Between HyperCoagulability, Electrical Remodelling, and Vascular Destabilisation in the Progression of AF (RACE V) registry, 202 patients with paroxysmal AF were followed with continuous rhythm monitoring (implantable loop recorder or pacemaker) for 6 months. Mean age was 64 ± 9 years, 42% were women. Atrial fibrillation history was 2.1 (0.5-4.4) years, CHA2DS2-VASc 1.9 ± 1.3, 101 (50%) had hypertension, 69 (34%) heart failure. One-third had no AF during follow-up. Patients with long episodes (>12 hours) were often men with more comorbidities (heart failure, coronary artery disease, higher left ventricular mass). Patients with higher AF burden (>2.5%) were older with more comorbidities (worse renal function, higher calcium score, thicker intima media thickness). In 179 (89%) patients, 1-year rhythm follow-up was available. On a quarterly basis, average daily AF burden increased from 3.2% to 3.8%, 5.2%, and 6.1%. Compared to the first 6 months, 111 (62%) patients remained stable during the second 6 months, 39 (22%) showed progression to longer AF episodes, 8 (3%) developed persistent AF, and 29 (16%) patients showed AF regression. CONCLUSIONS: In paroxysmal AF, temporal patterns differ suggesting that paroxysmal AF is not one entity. Atrial fibrillation burden is low and determined by number of comorbidities. Atrial fibrillation progression occurred in a substantial number. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov identifier NCT02726698.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Marca-Passo Artificial , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Espessura Intima-Media Carotídea , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
20.
Cardiology ; 145(2): 88-94, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31707389

RESUMO

INTRODUCTION: Recurrent ventricular tachycardia (VT) after percutaneous ablation is associated with a high morbidity and mortality. We assessed the feasibility of open chest extracorporeal circulation (ECC)-supported 3D multielectrode mapping and targeted VT substrate ablation in patients with previously failed percutaneous endocardial and epicardial VT ablations. METHODS: In patients with previously failed percutaneous endocardial and epicardial VT ablations and a high risk of hemodynamic collapse during the procedure, open chest ECC-supported mapping and ablation were performed in a hybrid EP lab setting. Electro-anatomic maps (3D) were acquired during sinus rhythm and VT using a multielectrode mapping catheter (HD grid; Abbott or Pentaray, Biosense Webster). Irrigated radiofrequency ablations of all inducible VT were performed with a contact force ablation catheter. RESULTS: Hybrid VT ablation was performed in 5 patients with structural heart disease (i.e., 3 with previous old myocardial infarction and 2 with nonischemic cardiomy-opathy) and recurrent VT. Acute procedural success was achieved in all patients. Four patients were successfully weaned off the ECC. In 1 patient with a severely reduced LVEF (16%), damage to the venous graft occurred after sternotomy and that patient died after 1 month. Four patients (80%) remained VT free after a median follow-up of 6 (IQR 4-10) months. CONCLUSION: In high-risk patients with previously failed percutaneous endocardial and epicardial VT ablations, open chest ECC-supported multielectrode epicardial mapping revealed a VT substrate in all of the patients, and targeted epicardial ablation abolished VT substrate in these patients.


Assuntos
Ablação por Cateter/métodos , Endocárdio/fisiopatologia , Mapeamento Epicárdico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Mapeamento Potencial de Superfície Corporal , Cardiomiopatia Dilatada/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Recidiva , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/patologia , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA