Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Anal Chem ; 91(11): 7336-7345, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31045344

RESUMO

Hydrogen-deuterium exchange mass spectrometry (HDX-MS) is an established, powerful tool for investigating protein-ligand interactions, protein folding, and protein dynamics. However, HDX-MS is still an emergent tool for quality control of biopharmaceuticals and for establishing dynamic similarity between a biosimilar and an innovator therapeutic. Because industry will conduct quality control and similarity measurements over a product lifetime and in multiple locations, an understanding of HDX-MS reproducibility is critical. To determine the reproducibility of continuous-labeling, bottom-up HDX-MS measurements, the present interlaboratory comparison project evaluated deuterium uptake data from the Fab fragment of NISTmAb reference material (PDB: 5K8A ) from 15 laboratories. Laboratories reported ∼89 800 centroid measurements for 430 proteolytic peptide sequences of the Fab fragment (∼78 900 centroids), giving ∼100% coverage, and ∼10 900 centroid measurements for 77 peptide sequences of the Fc fragment. Nearly half of peptide sequences are unique to the reporting laboratory, and only two sequences are reported by all laboratories. The majority of the laboratories (87%) exhibited centroid mass laboratory repeatability precisions of ⟨ sLab⟩ ≤ (0.15 ± 0.01) Da (1σx̅). All laboratories achieved ⟨sLab⟩ ≤ 0.4 Da. For immersions of protein at THDX = (3.6 to 25) °C and for D2O exchange times of tHDX = (30 s to 4 h) the reproducibility of back-exchange corrected, deuterium uptake measurements for the 15 laboratories is σreproducibility15 Laboratories( tHDX) = (9.0 ± 0.9) % (1σ). A nine laboratory cohort that immersed samples at THDX = 25 °C exhibited reproducibility of σreproducibility25C cohort( tHDX) = (6.5 ± 0.6) % for back-exchange corrected, deuterium uptake measurements.


Assuntos
Anticorpos Monoclonais/química , Espectrometria de Massa com Troca Hidrogênio-Deutério , Fragmentos Fab das Imunoglobulinas/análise
2.
Anal Chem ; 88(12): 6607-14, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27224086

RESUMO

Hydrogen/deuterium exchange coupled with mass spectrometry (HDX-MS) is an information-rich biophysical method for the characterization of protein dynamics. Successful applications of differential HDX-MS include the characterization of protein-ligand binding. A single differential HDX-MS data set (protein ± ligand) is often comprised of more than 40 individual HDX-MS experiments. To eliminate laborious manual processing of samples, and to minimize random and gross errors, automated systems for HDX-MS analysis have become routine in many laboratories. However, an automated system, while less prone to random errors introduced by human operators, may have systematic errors that go unnoticed without proper detection. Although the application of automated (and manual) HDX-MS has become common, there are only a handful of studies reporting the systematic evaluation of the performance of HDX-MS experiments, and no reports have been published describing a cross-site comparison of HDX-MS experiments. Here, we describe an automated HDX-MS platform that operates with a parallel, two-trap, two-column configuration that has been installed in two remote laboratories. To understand the performance of the system both within and between laboratories, we have designed and completed a test-retest repeatability study for differential HDX-MS experiments implemented at each of two laboratories, one in Florida and the other in Spain. This study provided sufficient data to do both within and between laboratory variability assessments. Initial results revealed a systematic run-order effect within one of the two systems. Therefore, the study was repeated, and this time the conclusion was that the experimental conditions were successfully replicated with minimal systematic error.


Assuntos
Medição da Troca de Deutério/métodos , Espectrometria de Massas/métodos , Análise de Variância , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Deutério/análise , Medição da Troca de Deutério/instrumentação , Hidrogênio/análise , Ligantes , Espectrometria de Massas/instrumentação , Peptídeos/análise , Proteínas/química , Receptores de Calcitriol/química , Reprodutibilidade dos Testes
4.
World J Gastroenterol ; 30(22): 2866-2880, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38947288

RESUMO

Coronavirus disease 2019 (COVID-19), caused by the highly pathogenic severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), primarily impacts the respiratory tract and can lead to severe outcomes such as acute respiratory distress syndrome, multiple organ failure, and death. Despite extensive studies on the pathogenicity of SARS-CoV-2, its impact on the hepatobiliary system remains unclear. While liver injury is commonly indicated by reduced albumin and elevated bilirubin and transaminase levels, the exact source of this damage is not fully understood. Proposed mechanisms for injury include direct cytotoxicity, collateral damage from inflammation, drug-induced liver injury, and ischemia/hypoxia. However, evidence often relies on blood tests with liver enzyme abnormalities. In this comprehensive review, we focused solely on the different histopathological manifestations of liver injury in COVID-19 patients, drawing from liver biopsies, complete autopsies, and in vitro liver analyses. We present evidence of the direct impact of SARS-CoV-2 on the liver, substantiated by in vitro observations of viral entry mechanisms and the actual presence of viral particles in liver samples resulting in a variety of cellular changes, including mitochondrial swelling, endoplasmic reticulum dilatation, and hepatocyte apoptosis. Additionally, we describe the diverse liver pathology observed during COVID-19 infection, encompassing necrosis, steatosis, cholestasis, and lobular inflammation. We also discuss the emergence of long-term complications, notably COVID-19-related secondary sclerosing cholangitis. Recognizing the histopathological liver changes occurring during COVID-19 infection is pivotal for improving patient recovery and guiding decision-making.


Assuntos
COVID-19 , Fígado , SARS-CoV-2 , Humanos , COVID-19/complicações , COVID-19/patologia , COVID-19/virologia , Fígado/patologia , Fígado/virologia , SARS-CoV-2/patogenicidade , Hepatopatias/patologia , Hepatopatias/virologia , Hepatopatias/etiologia , Hepatócitos/patologia , Hepatócitos/virologia
5.
NPJ Breast Cancer ; 8(1): 126, 2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36446794

RESUMO

Despite the biological and therapeutic relevance of CDK4/6 for the treatment of HR+, HER2- advanced breast cancer, the detailed mode of action of CDK4/6 inhibitors is not completely understood. Of particular interest, phosphorylation of CDK4 at T172 (pT172) is critical for generating the active conformation, yet no such crystal structure has been reported to date. We describe here the x-ray structure of active CDK4-cyclin D3 bound to the CDK4/6 inhibitor abemaciclib and discuss the key aspects of the catalytically-competent complex. Furthermore, the effect of CDK4/6 inhibitors on CDK4 T172 phosphorylation has not been explored, despite its role as a potential biomarker of CDK4/6 inhibitor response. We show mechanistically that CDK4/6i stabilize primed (pT172) CDK4-cyclin D complex and selectively displace p21 in responsive tumor cells. Stabilization of active CDK4-cyclin D1 complex can lead to pathway reactivation following alternate dosing regimen. Consequently, sustained binding of abemaciclib to CDK4 leads to potent cell cycle inhibition in breast cancer cell lines and prevents rebound activation of downstream signaling. Overall, our study provides key insights demonstrating that prolonged treatment with CDK4/6 inhibitors and composition of the CDK4/6-cyclin D complex are both critical determinants of abemaciclib efficacy, with implications for this class of anticancer therapy.

6.
ACS Chem Biol ; 16(3): 457-462, 2021 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-33656326

RESUMO

Lipoprotein lipase (LPL) is the key enzyme that hydrolyzes triglycerides from triglyceride-rich lipoproteins. Angiopoietin-like proteins (ANGPTL) 3, 4, and 8 are well-characterized protein inhibitors of LPL. ANGPTL8 forms a complex with ANGPTL3, and the complex is a potent endogenous inhibitor of LPL. However, the nature of the structural interaction between ANGPTL3/8 and LPL is unknown. To probe the conformational changes in LPL induced by ANGPTL3/8, we found that HDX-MS detected significantly altered deuteration in the lid region, ApoC2 binding site, and furin cleavage region of LPL in the presence of ANGPTL3/8. Supporting this HDX structural evidence, we found that ANGPTL3/8 inhibits LPL enzymatic activities and increases LPL cleavage. ANGPTL3/8-induced effects on LPL activity and LPL cleavage are much stronger than those of ANGPTL3 or ANGPTL8 alone. ANGPTL3/8-mediated LPL cleavage is blocked by both an ANGPTL3 antibody and a furin inhibitor. Knock-down of furin expression by siRNA significantly reduced ANGPT3/8-induced cleavage of LPL. Our data suggest ANGPTL3/8 promotes furin-mediated LPL cleavage.


Assuntos
Proteínas Semelhantes a Angiopoietina/química , Lipase Lipoproteica/antagonistas & inibidores , Lipase Lipoproteica/química , Proteólise/efeitos dos fármacos , Sítios de Ligação , Deutério/química , Furina/química , Furina/genética , Regulação da Expressão Gênica , Técnicas de Silenciamento de Genes , Humanos , Hidrólise , Marcação por Isótopo , Espectrometria de Massas , Modelos Moleculares , Ligação Proteica , Conformação Proteica , RNA Interferente Pequeno/metabolismo
7.
Protein Eng Des Sel ; 332020 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-33009572

RESUMO

Intrinsic low display level of polypeptides on phage is a fundamental and limiting hurdle in successful isolation of target-specific binders by phage display technology. To circumvent this challenge, we optimized the copy number of peptides displayed on the phage surface using type 33 phage vector. We randomized the first 67 amino acids of the wild type PIII to identify mutants that would result in its reduced expression. Consequently, the display level was improved by 30-fold due to higher incorporation of the synthetic PIII-peptide fusion protein on the phage surface. Utilization of this novel phage vector should provide a solid basis for the discovery of therapeutic peptides.


Assuntos
Bacteriófago M13/genética , Vetores Genéticos/genética , Biblioteca de Peptídeos , Proteínas Recombinantes de Fusão/genética , Proteínas Virais/genética , Humanos
8.
PLoS One ; 15(6): e0233961, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32479512

RESUMO

Hundreds of target specific peptides are routinely discovered by peptide display platforms. However, due to the high cost of peptide synthesis only a limited number of peptides are chemically made for further analysis. Here we describe an accurate and cost effective method to bin peptides on-phage based on binding region(s), without any requirement for peptide or protein synthesis. This approach, which integrates phage and yeast display platforms, requires display of target and its alanine variants on yeast. Flow cytometry was used to detect binding of peptides on-phage to the target on yeast. Once hits were identified, they were synthesized to confirm their binding region(s) by HDX (Hydrogen deuterium exchange) and crystallography. Moreover, we have successfully shown that this approach can be implemented as part of a panning process to deplete non-functional peptides. This technique can be applied to any target that can be successfully displayed on yeast; it narrows down the number of peptides requiring synthesis; and its utilization during selection results in enrichment of peptide population against defined binding regions on the target.


Assuntos
Técnicas de Visualização da Superfície Celular/métodos , Biblioteca de Peptídeos , Alanina/genética , Alanina/metabolismo , Bacteriófagos/genética , Bacteriófagos/metabolismo , Técnicas de Visualização da Superfície Celular/economia , Análise Custo-Benefício , Citometria de Fluxo/economia , Citometria de Fluxo/métodos , Subunidade p40 da Interleucina-12/genética , Subunidade p40 da Interleucina-12/metabolismo , Mutação , Ligação Proteica/genética , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Reprodutibilidade dos Testes , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo
9.
J Am Soc Mass Spectrom ; 30(12): 2580-2583, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31724102

RESUMO

Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a biophysical technique well suited to the characterization of protein dynamics and protein-ligand interactions. In order to accurately define the rate of exchange, HDX experiments require the repeated measure of deuterium incorporation into the target protein across a range of time points. Accordingly, the HDX-MS experiment is well suited to automation, and a number of automated systems for HDX-MS have been developed. The most widely utilized platforms all operate an integrated design, where robotic liquid handling is interfaced directly with a mass spectrometer. With integrated designs, the exchange samples are prepared and injected into the LC-MS following a "real-time" serial workflow. Here we describe a new HDX-MS platform that is comprised of two complementary pieces of automation that disconnect the sample preparation from the LC-MS analysis. For preparation, a plate-based automation system is used to prepare samples in parallel, followed by immediate freezing and storage. A second piece of automation has been constructed to perform the thawing and LC-MS analysis of frozen samples in a serial mode and has been optimized to maximize the duty cycle of the mass spectrometer. The decoupled configuration described here reduces experiment time, significantly improves capacity, and improves the flexibility of the platform when compared with a fully integrated system.


Assuntos
Espectrometria de Massa com Troca Hidrogênio-Deutério/métodos , Descoberta de Drogas/economia , Descoberta de Drogas/instrumentação , Descoberta de Drogas/métodos , Desenho de Equipamento , Análise de Injeção de Fluxo/economia , Análise de Injeção de Fluxo/instrumentação , Análise de Injeção de Fluxo/métodos , Humanos , Espectrometria de Massa com Troca Hidrogênio-Deutério/economia , Espectrometria de Massa com Troca Hidrogênio-Deutério/instrumentação , Ligantes , Proteínas/química
10.
Drug Discov Today ; 13(9-10): 417-23, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18468559

RESUMO

The broad coordinated implementation of common platform technologies, such as LC/MS, can be a key factor in attaining increased throughput, sensitivity and data quality for pharmaceutical discovery. These platform technologies are the key tools that Medicinal Analytical Chemists rely upon to address the ever-changing needs of a drug discovery team. Despite the recent advances in key areas of sensitivity and speed for LC/MS, additional progress to address these never-ending analytical problems can be anticipated. This review will highlight current status and future advances for the applications of LC/MS and related techniques to high-throughput drug discovery.


Assuntos
Desenho de Fármacos , Cromatografia Líquida , Espectrometria de Massas
11.
ACS Med Chem Lett ; 9(9): 912-916, 2018 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-30258540

RESUMO

Molecular characterization of the binding epitope of IL-23R and its cognate cytokine IL-23 is paramount to understand the role in autoimmune diseases and to support the discovery of new inhibitors of this protein-protein interaction. Our results revealed that HDX-MS was able to identify the binding epitope of IL-23R:IL-23, which opened the way to evaluate a peptide macrocycle described in the literature as disrupter of this autoimmune target. Thus, the characterization of the interactions of this chemotype by HDX-MS in combination with computational approaches was achieved. To our knowledge, this is the first reported structural evidence regarding the site where a small compound binds to IL-23R.

12.
PLoS One ; 13(1): e0190850, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29329326

RESUMO

To date, IL-17A antibodies remain the only therapeutic approach to correct the abnormal activation of the IL-17A/IL-17R signaling complex. Why is it that despite the remarkable success of IL-17 antibodies, there is no small molecule antagonist of IL-17A in the clinic? Here we offer a unique approach to address this question. In order to understand the interaction of IL-17A with its receptor, we combined peptide discovery using phage display with HDX, crystallography, and functional assays to map and characterize hot regions that contribute to most of the energetics of the IL-17A/IL-17R interaction. These functional maps are proposed to serve as a guide to aid in the development of small molecules that bind to IL-17A and block its interaction with IL-17RA.


Assuntos
Colífagos/metabolismo , Interleucina-17/metabolismo , Peptídeos/metabolismo , Receptores de Interleucina-17/metabolismo , Cristalografia por Raios X , Ensaio de Imunoadsorção Enzimática , Células HT29 , Humanos , Interleucina-17/química , Modelos Moleculares , Receptores de Interleucina-17/química , Ressonância de Plasmônio de Superfície
13.
J Phys Chem B ; 121(15): 3493-3501, 2017 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-27807976

RESUMO

Characterization of interactions between proteins and other molecules is crucial for understanding the mechanisms of action of biological systems and, thus, drug discovery. An increasingly useful approach to mapping these interactions is measurement of hydrogen/deuterium exchange (HDX) using mass spectrometry (HDX-MS), which measures the time-resolved deuterium incorporation of peptides obtained by enzymatic digestion of the protein. Comparison of exchange rates between apo- and ligand-bound conditions results in a mapping of the differential HDX (ΔHDX) of the ligand. Residue-level analysis of these data, however, must account for experimental error, sparseness, and ambiguity due to overlapping peptides. Here, we propose a Bayesian method consisting of a forward model, noise model, prior probabilities, and a Monte Carlo sampling scheme. This method exploits a residue-resolved exponential rate model of HDX-MS data obtained from all peptides simultaneously, and explicitly models experimental error. The result is the best possible estimate of ΔHDX magnitude and significance for each residue given the data. We demonstrate the method by revealing richer structural interpretation of ΔHDX data on two nuclear receptors: vitamin D-receptor (VDR) and retinoic acid receptor gamma (RORγ). The method is implemented in HDX Workbench and as a standalone module of the open source Integrative Modeling Platform.


Assuntos
Medição da Troca de Deutério , Espectrometria de Massas , Proteínas/química , Teorema de Bayes , Ligantes , Simulação de Dinâmica Molecular , Método de Monte Carlo
15.
Org Lett ; 8(21): 4967-70, 2006 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-17020348

RESUMO

[reaction: see text] (-)-(5S)-2-Imino-1-methylpyrrolidine-5-carboxylic acid (1), previously reported as the N-acetyl-beta-d-glucosaminidase inhibitor pyrostatin B, has been isolated from the organic extracts of the burrowing sponge Cliona tenuis. The structure of 1, including its absolute stereochemistry, was characterized from its spectral data and chemical transformations and confirmed by total synthesis. The synthesis of 1 reveals that the structure of pyrostatin B has been incorrectly assigned. Comparison of NMR spectral data strongly suggests that pyrostatins A and B are identical to 5-hydroxyectoine and ectoine, respectively.


Assuntos
Diamino Aminoácidos/química , Iminas/química , Iminas/síntese química , Poríferos/química , Pirrolidinas/química , Pirrolidinas/síntese química , Animais , Iminas/isolamento & purificação , Estrutura Molecular , Ressonância Magnética Nuclear Biomolecular , Pirrolidinas/isolamento & purificação , Estereoisomerismo
16.
J Med Chem ; 59(5): 2255-60, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26854023

RESUMO

Computational assessment of the IL-17A structure identified two distinct binding pockets, the ß-hairpin pocket and the α-helix pocket. The ß-hairpin pocket was hypothesized to be the site of binding for peptide macrocycles. Support for this hypothesis was obtained using HDX-MS which revealed protection to exchange only within the ß-hairpin pocket. This data represents the first direct structural evidence of a small molecule binding site on IL-17A that functions to disrupt the interaction with its receptor.


Assuntos
Medição da Troca de Deutério , Interleucina-17/antagonistas & inibidores , Compostos Macrocíclicos/farmacologia , Espectrometria de Massas , Peptídeos Cíclicos/farmacologia , Sítios de Ligação/efeitos dos fármacos , Relação Dose-Resposta a Droga , Humanos , Interleucina-17/metabolismo , Compostos Macrocíclicos/síntese química , Compostos Macrocíclicos/química , Modelos Moleculares , Conformação Molecular , Peptídeos Cíclicos/síntese química , Peptídeos Cíclicos/química , Relação Estrutura-Atividade
17.
Chem Biodivers ; 2(1): 123-30, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17191925

RESUMO

In the course of our screening efforts to discover small molecules as selective inhibitors of vacuolar-type H+-ATPase of Saccharomyces cerevisiae, we have identified eight active destruxins, 1-8, from the fungus Metarhizium anisopliae. The structures were elucidated by extensive 1D- and 2D-NMR spectroscopy, and MS spectrometry. One of these compounds, 8, a regioisomer of chlorohydrin destruxin E (7), is a new destruxin.


Assuntos
Depsipeptídeos/metabolismo , Depsipeptídeos/farmacologia , Saccharomyces cerevisiae/enzimologia , ATPases Vacuolares Próton-Translocadoras/antagonistas & inibidores , Animais , Galinhas , Relação Dose-Resposta a Droga , Fermentação , Concentração Inibidora 50 , Metarhizium/metabolismo , Estrutura Molecular , Osteoclastos , Fatores de Tempo , ATPases Vacuolares Próton-Translocadoras/metabolismo
18.
J Chromatogr A ; 987(1-2): 211-20, 2003 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-12613814

RESUMO

Ammonium hydrogencarbonate buffer has been found to be especially useful for high-pH HPLC analysis of samples from both combinatorial and medicinal chemistry sources. Satisfactory results were obtained by the standard diode array, evaporative light-scattering, and MS detection by using this buffer at a concentration of 10 mM. From a practical standpoint, ammonium hydrogencarbonate is an ideal buffer for chromatographers since it provides excellent chromatographic behaviour and reproducible separation. In addition to this, its volatility makes it an essential tool for rapid LC-MS product identification. Ammonium hydrogencarbonate was tested for a number of drug-like compounds analysed as mixtures, and data obtained were compared to those from the classical and MS-friendly buffers widely used by chromatographers: trifluoroacetic and formic acids. The results of this study revealed the suitability of this buffer for routine HPLC application in research laboratories.


Assuntos
Soluções Tampão , Carbonatos/química , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Espectrometria de Massas/métodos
19.
J Chromatogr A ; 1030(1-2): 43-51, 2004 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-15043252

RESUMO

Careful selection of both high-pH mobile phase as well as organic modifier, was performed in order to develop and optimize HPLC conditions for the separation of drug discovery compounds. High-pH mobile phases provide excellent chromatographic resolution and increased mass loading of basic compounds. The analytical methods so defined have been successfully transferred to preparative automated UV-directed purification, an important fact due to the increasing number of samples requiring purification. It should be noted that, the single prerequisite for this approach is an analytical LC-UV-MS run, therefore the system has the ability to collect only fractions likely to contain the target product. A cost-effective strategy for maximizing the purification of drug discovery compounds is proposed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio
20.
Drug Discov Today ; 17(7-8): 396-404, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22387356

RESUMO

Capillary electrophoresis (CE) is an analytical technique based on the separation of the analytes within a capillary owing to their different electrophoretic mobilities. It is widely used in pharmaceutical analyses owing to its versatility and high separation power. However, its penetration into the drug discovery scene has been relatively limited until recent years. Several factors have contributed to this low implementation, including the maturity of liquid chromatography, the scarcity of experienced CE practitioners, and certain limitations intrinsic to the technique. Recently, instrumental improvements and the growing demand for analytical information have lead to a continuously expanding range of routine electrophoretic applications throughout pharmaceutical discovery and development. In this article we review CE fundamentals, review well-established CE methodologies in drug discovery of small molecules and discuss trends that, in our opinion, might emerge in the coming years.


Assuntos
Descoberta de Drogas/métodos , Eletroforese Capilar/métodos , Preparações Farmacêuticas/química , Humanos , Preparações Farmacêuticas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA